• Title/Summary/Keyword: low velocity

Search Result 2,854, Processing Time 0.027 seconds

Development of Collision Tester for Performance Evaluation of Safety Fence in Baseball Stadiums (야구장 안전펜스 성능평가를 위한 충돌시험기 개발)

  • Han, Eui Don;Jang, Woong Ki;Kho, Sun Tak;Kwak, Ho Taek;Seo, Young Ho;Kim, Byeong Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.957-962
    • /
    • 2013
  • This paper presents a performance testing device for safety fences of domestic professional baseball stadiums. Safety fences of professional stadiums have been fabricated and installed without adhering to any safety regulations, safety fences demonstrate critically low safety performances and many outfielders are severely injured every season. In this study, we designed and fabricated a performance testing device for safety fences and investigated its validity and reproducibility. A HIC (head injury criterion) was used for the statistical analysis of colliding data. We found that the optimal expulsion pressure and eliminated the accelerometer by replacing it with a velocity sensor using an estimation of the correlation between the momentum data obtained from velocity sensor and the impulse data from the accelerometer.

Active-passive control of flexible sturctures using piezoelectric sensor/actuator (압전형 센서/액추에이터를 이용한 진동구조물의 능동-수동제어)

  • 고병식
    • Journal of KSNVE
    • /
    • v.5 no.3
    • /
    • pp.313-325
    • /
    • 1995
  • Two active/passive vibration dampers were designed to control a cantilever beam first mode of vibration. The active element was a piezoelectric polymer, polyvinlidene fluoride (PVDF). The passive damping was provided by the application of a viscoelastic layer on the surface of the steel beam. Two substantially different damper configurations were designed and tested. One damper consisted of a piezoelectric actuator bonded to one face of the beam, with a viscoelastic layer applied to the other surface of the beam. The second one was composed of a layer viscoeastic layer with one surface bonded to the beam, and with other being constrained by nine piezoelectric actuators connected in parallel. A control law based on the sign of the angular velocity of the cantilever beam was implemented to control the beam first mode of vibration. The piezoelectric sensor output was digitally differentiated to obtain the transverse linear velocity, and its sign was used in the control algorith. Two dampers provided the system a damping increase of a factor of four for the first damper and three for the second damper. Both dampers were found to work well at low levels of vibration, suggesting that they can be used effectively to prevent resonant vibrations in flexible structure from initiating and building up.

  • PDF

A Study on the Ignition Characteristics at Constant Volume Combustion Chamber of LPG (LPG 정적연소실내 점화특성에 관한 연구)

  • 박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.75-82
    • /
    • 2004
  • The allowable exhaust standard has been intensified as a part of the countermeasure to decrease air pollution in the world. As the cars with an alternative fuel starts to get into the spotlight, the cars with low emission has been introduced and exhaust gas regulation forced in this country. These days, LPG vehicles, which infrastructure of fuel was already built up, and CNG vehicles are recognized for alternative fuel cars in this country. In this study, the constant volume combustion chamber was manufactured and used for experiments to obtain the ignition characteristics of LPG fuel and the optimal ignition energy. The experiment measured the combustion characteristics, in regard to the change of combustion variable, and the change of ignition energy. During the combustion of fuel, the maximum temperature inside the combustion chamber is higher when the initial pressure is higher. The burning velocity also seems to have the same characteristic as the temperature. However, the heat flux did not change much with the theoretical correct mixture but the various initial temperature of the combustion chamber. The heat flux got faster and ignition energy bigger as the dwell time of the ignition system expanded. When the dwell time get longer, the ignition energy also increased then fixed. The ignition energy increased as the initial pressure inside the combustion chamber higher. The heat flux got faster as the dwell time expanded.

Features of the flow over a finite length square prism on a wall at various incidence angles

  • Sohankar, A.;Esfeh, M. Kazemi;Pourjafari, H.;Alam, Md. Mahbub;Wang, Longjun
    • Wind and Structures
    • /
    • v.26 no.5
    • /
    • pp.317-329
    • /
    • 2018
  • Wake characteristics of the flow over a finite square prism at different incidence angles were experimentally investigated using an open-loop wind tunnel. A finite square prism with a width D = 15 mm and a height H = 7D was vertically mounted on a horizontal flat plate. The Reynolds number was varied from $6.5{\times}10^3$ to $28.5{\times}10^3$ and the incidence angle ${\alpha}$ was changed from $0^{\circ}$ to $45^{\circ}$. The ratio of boundary layer thickness to the prism height was about ${\delta}/H=7%$. The time-averaged velocity, turbulence intensity and the vortex shedding frequency were obtained through a single-component hotwire probe. Power spectrum of the streamwise velocity fluctuations revealed that the tip and base vortices shed at the same frequency as that ofspanwise vortices. Furthermore, the results showed that the critical incidence angle corresponding to the maximum Strouhal number and minimum wake width occurs at ${\alpha}_{cr}=15^{\circ}$ which is equal to that reported for an infinite prism. There is a reduction in the size of the wake region along the height of the prism when moving away from the ground plane towards the free end.

The Search for Binaries in Post-Asymptotic Giant Branch Stars: Do Binary Companions Shape the Nebulae?

  • Hrivnak, Bruce J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Binary companions are often invoked to explain the axial and point symmetry seen in the majority of planetary nebulae and proto-planetary nebulae (PPNs). To explore this hypothesis, we have undertaken a long-term (20 year) study of light and velocity variations in PPNs. From the photometric study of 24 PPNs, we find that all vary in brightness, and from a subset of 12 carbon-rich PPNs of F-G spectral type we find periods of 35-155 days, with the cooler having the longer periods. The variations are seen to be due to pulsation; no photometric evidence for binarity is seen. A radial velocity study of a sub-sample of seven of the brightest of these shows that they all vary with the pulsation periods. Only one shows evidence of a longer-term variation that we tentatively identify as being due to a binary companion. We conclude that the present evidence for the binary nature of these PPNs is meager and that any undetected companions of these PPNs must be of low mass (< 0.25 $M_{\odot}$) or long period (> 30 years).

A Experimental Study on the Observation of Free-Surface Flow around Ship's Bow (선수부 주위의 자곡표면류의 유동관측에 관한 실험적 고찰)

  • 박명규;김동률
    • Journal of the Korean Institute of Navigation
    • /
    • v.17 no.1
    • /
    • pp.37-48
    • /
    • 1993
  • When the vessel is running at the very low Froude numbers, the free-surface is difficult to be disturbed, wave-making is negligible, and the double -model velocity potential gives a very good approximation for calculating the velocity distribution just outside the boundary layer. If the speed of incident flow is gradually increased, the most perceptible change is the rise of the flow surface at stem. With further increase in speed, the nature of the flow at the bow changes completely, The flow ahead of the bow becomes more distrubed, the rise at the stem to stagnation height disappear, and the first wave crest, of less than the stagnation height, appears a small distance downstream from the stem. The present study is concerned with a small region of this flow, mainly in the bow region. The present investigation is primarily an experimental study of the flow in the bow region of s ship model, and it is undertaken in order to investigated systematically, the effect of bow geometry on this flow. The long-range objective is to use these results to guide the development of a mathematical model for predicting the flow about a ship's bow.

  • PDF

A Study on Heat Transfer Characteristics in Flow Boiling of Pure Refrigerants and Their Mixtures in Horizontal Tube (수평 전열관내 유동비등하는 순수냉매와 혼합냉매의 열전달 특성에 관한 연구)

  • 임태우;한규일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.144-151
    • /
    • 2003
  • An experimental study was carried out in a uniformly heated horizontal tube to examine heat transfer characteristics of pure refrigerants, R134a and R123, and their mixtures during flow boiling. The flow pattern was also observed through tubular sight glasses with an internal diameter of 10 mm located at the inlet and outlet of the test section. Tests were run at a pressure of 0.6 MPa and in the heat flux ranges of 5~100 kW/$m^2$, vapor Quality 0~100 percent and mass velocity of 150-600 kg/$m^2$s. The observed flow patterns were compared to the flow pattern map of Kattan et al., which predicted well the present data over the entire range of mass velocity employed in this study. Heat transfer coefficients of the mixture were less than the interpolated values between pure fluids both in the low quality region where the nucleate boiling is dominant and in the high quality region where the convective evaporation is dominant.

The Kinematic Analysis of Peters Motion on Parallel bars (평행봉 피터스 동작의 운동학적 분석)

  • Yoon, Hee-Joong;Yoon, Chang-Sun;Kim, Tae-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.2
    • /
    • pp.15-26
    • /
    • 2004
  • The purpose of this study was to investigate the kinematic variables of peters motion in parallel bars. The subjects were 3 male national gymnasts. For this study, kinematic data were collected using video camera. Coordinate data were low-pass filtered using a fourth-order Butterworth with cutoff frequency of 6Hz. Each valuables analyzed was used to compare kinematic features between the subjects. The conclusions were as follows; 1. For a stable regrasp motion, the subjects appeared to increase horizontal and vertical displacement during the DS phase because it induce a vertical elastic of body and reaction of bar for the US phase. 2. For a stable hand standing motion of the regrasp, the subjects appeared to maintain the fast vertical and horizontal velocity during the DS phase, but in contrary during the US and Air phase the vertical and horizontal velocity appeared to do decrease. 3. When the arm lean angle and the trunk lean angle maintain a big angle during the DS phase, the subjects appeared to do a stable performance to release in a high position.

The Remodelling of Hydraulic Structure in a Distribution Channel for Improving the Equality of the Flow Distribution (II): Optimization through Wet Tests (수리구조 개선을 통한 분배수로 균등분배 성능 향상에 관한 연구(II): Pilot plant 실험을 통한 최적화)

  • Park, No-Suk;Kim, Seong-Su;Hwang, Jun-Sick;Im, Jae-Rim;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.581-587
    • /
    • 2007
  • In order to suggest the methodology for improving the equality of flow distribution in a distribution channel, wet tests were carried out for pilot plant which was scaled down to 1/8 of full scale distribution channel being operated in domestic K_water treatment plant. The correlation between various hydraulic variables and their effects on the equality of flow distribution was evaluated through wet tests using pilot plant. From the results of wet tests, the longitudinal baffle with orifices was installed in the distribution channel, the equality of flow distribution was improved on the condition that the Froude number in pilot plant was similar with that in the full scale channel. Also, the opening ratio of the orifices on the longitudinal baffled did not have influence on the performance of the equality of flow distribution when the average flow velocity and Froud number were relatively low (Froude number ${\fallingdotseq} 0.01$). In the other hand, the performance of the equality of flow distribution was improved with increasing the opening ration of on the longitudinal baffle under conditions of relatively high average flow velocity and high Froud number(${\gtrsim}0.1$)

Performance Improvement of an INS by using a Magnetometer with Pedestrian Dynamic Constraints

  • Woyano, Feyissa;Park, Aangjoon;Lee, Soyeon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • This paper proposes to improve the performance of a strap down inertial navigation system using a foot-mounted low-cost inertial measurement unit/magnetometer by configuring an attitude and heading reference system. To track position accurately and for attitude estimations, considering different dynamic constraints, magnetic measurement and a zero velocity update technique is used. A conventional strap down method based on integrating angular rate to determine attitude will inevitably induce long-term drift, while magnetometers are subject to short-term orientation errors. To eliminate this accumulative error, and thus, use the navigation system for a long-duration mission, a hybrid configuration by integrating a miniature micro electromechanical system (MEMS)-based attitude and heading detector with the conventional navigation system is proposed in this paper. The attitude and heading detector is composed of three-axis MEMS accelerometers and three-axis MEMS magnetometers. With an absolute algorithm based on gravity and Earth's magnetic field, rather than an integral algorithm, the attitude detector can obtain an absolute attitude and heading estimation without drift errors, so it can be used to adjust the attitude and orientation of the strap down system. Finally, we verify (by both formula analysis and from test results) that the accumulative errors are effectively eliminated via this hybrid scheme.