• 제목/요약/키워드: low temperature damage

검색결과 517건 처리시간 0.025초

미국삼(Panax quinquefolium)의 저온 저항성에 관한 연구 (Low Temperature Tolerance of Panax quinquefolium)

  • Lee, Jong-Chul;John, T.A.Proctor
    • Journal of Ginseng Research
    • /
    • 제20권2호
    • /
    • pp.179-183
    • /
    • 1996
  • One exotherm was detected in the intact ginseng seeds containing more than 35% water, but in seeds with 20% there was no exotherm. The shapes of exotherm were remarkably uniform without relation to water content above 35%. The temperature at the initiation of freezing varied from -3.5$^{\circ}C$ to -9.6$^{\circ}C$ with the different water content in the seeds, and the Initial temperature of freezing delayed with the decrease of water content. The resistance damage at low temperature appeared in order of maln body, rhizome, lateral root of 3-year-old yearling rhizome, and fine root of 3-year-old. Ginseng roots didn't receive any damage at -5$^{\circ}C$ for 24 hours. Otherwise they received serious damage below -1$0^{\circ}C$ even for 5 hours'exposure. Hence, alternative low temperature gave more severe damage compared to constant low temperature. This result suggests that the Possibility of receiving injury at low temperature was higher during the thawing season of the early spring than in the winter.

  • PDF

Aspects of spike damage by cold stress during young spike development period in wheat

  • Ahn, Seunghyun;Kim, Deawook;Lee, Hyeonseok;Jeong, Jaehyeok;Jeong, Hanyong;Hwang, Woonha;Choi, Kyungjin;Park, Hongkyu;Youn, Jongtag
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.199-199
    • /
    • 2017
  • This study investigated the aspects of damage due to low temperature treatment in order to establish the damage criterion according to low temperature invasion during regeneration period in wheat after regeneration period in the early spring. We cultivated wheat cultivar 'Geumgang' in Wagner pots and treated them with three types of low temperature, and the gradual temperature change program was set in a low temperature incubator for 12.5 h per day for 5 days during the night time when the length of young spikes was about 1 mm. All treatments except for the control were treated in 5 steps for each temperature. Treatment 1 was treated at the lowest temperature $-5^{\circ}C$ for 5 h, treatment 2 for 7 h at $-5^{\circ}C$, and treatment 3 for 9 h at $-5^{\circ}C$. The most common type of damage was partial infertility, and there were some discolored spikes. The damage rate of wheat spikes treated at $-5^{\circ}C$ for 9 h was the highest, while the damage rates of wheat sprouts treated at 5h and 7h were not different from each other. It was found that the damage of wheat spikes exposed to low temperatures for a long time was large. It is necessary to investigate the aspects of spike damage by duration days of low temperature.

  • PDF

복합적층재의 온도에 의한 저속충격특성 (Effect of Temperature on Low Velocity Impact Characteristics of Composite Laminates)

  • 한영욱;김후식;김재훈;이영신;조정미;박병준
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.93-96
    • /
    • 2002
  • Instrumented impact tests and compression-after-impact(CAI) tests have been used to evaluate the effect of temperature on the low-velocity impact characteristics of phenolic matrix composites reinforced with various woven glass fabric. Impact characteristics and damage area in laminates are evaluated by C-scan. It is shown that the extent of damage and residual compressive strength of the laminates vary with energy level and impact test temperature. The damage area increases with increasing impact energy and temperature. All these observations indicate reduced impact damage resistance and damage tolerance of the laminates at elevated temperature.

  • PDF

Damage Mechanism of Asphalt Concrete under Low Temperatures

  • Kim, Kwang-Woo;Yeon, Kyu-Seok;Park, Je-Seon
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.200-204
    • /
    • 1994
  • Low temperature associated damage mechanism is not well known for asphalt concrete. Many studies have related the thermal cracking of pavement in the roadway in cold region with overall shrinkage of the pavement surface under assumption of homogeneous material. This study, however, was intiated based on the assumption that thermal incompatibility of materials (heterogeneous) in asphalt concrete mixture would be the primary cause of the damages. Acoustic emission technique and microscopic obsevation were employed to evaluate damage mechanism of asphalt concrete due to low temperature. The first method showed the sufficient evidence that asphalt concrete could be damaged by lowered temperature only. The second method showed that the damage by temperature resulted in micro-cracks at the interface between asphalt matrix and aggregate particle. It was concluded that these damage mechanisms were the primary cause of major thermal cracking of asphalt pavement in cold region.

  • PDF

경량전철 복합 적층판의 환경변화에 대한 저속충격특성 (Low velocity impact characteristics on environmental variation of composite laminates used in the light rail transit)

  • 김후식;김재훈;이영신;박병준;조정미
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.86-91
    • /
    • 2002
  • Glass/phenolic composite laminates have been used in the field of non-flammable light rail transit and their applications have expanded more widely. Low velocity impact tests have been used to evalute the effect of temperature and acceleration aging on low velocity impact response of phenolic matrix composites reinforced with woven E-glass fabric. The damage of matrix cracking and delamination are suddenly reduced the compressive strength after impact. The damage area increases with increasing temperature and impact energy. UT C-scan is used to determine damage areas by impact loading. Therefore, all this observations indicate reduced impact damage resistance and damage tolerance of the laminates at elevated temperature.

  • PDF

Rapid S-N type life estimation for low cycle fatigue of high-strength steels at a low ambient temperature

  • Feng, Liuyang;Qian, Xudong
    • Steel and Composite Structures
    • /
    • 제33권6호
    • /
    • pp.777-792
    • /
    • 2019
  • This paper presents a new efficient approach to estimate the S-N type fatigue life assessment curve for S550 high strength steels under low-cycle actions at -60℃. The proposed approach combines a single set of monotonic tension test and one set of fatigue tests to determine the key material damage parameters in the continuum damage mechanics framework. The experimental program in this study examines both the material response under low-cycle actions. The microstructural mechanisms revealed by the Scanning Electron Microscopy (SEM) at the low temperature, furthermore, characterizes the effect due to different strain ratios and low temperature on the low-cycle fatigue life of S550 steels. Anchored on the experimental results, this study validates the S-N curve determined from the proposed approach. The S-N type curve determined from one set of fatigue tests and one set of monotonic tension tests estimates the fatigue life of all specimens under different strain ratios satisfactorily.

초기 저온의 온도변화가 초기동해 깊이에 미치는 영향 (The Effect of Changes in Early Low-Temperatures in Early-Frost Damage Depth)

  • 김태우;김민상;문병룡;이제현;김동규;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.207-208
    • /
    • 2017
  • The current study assumed a condition in which concrete curing was not completed correctly in the winter, in order to analyze the effect of changes in early low-temperatures in early-frost damage depth. As a result, lower external temperature early on after depositing the concrete greatly reduced the temperature in the upper parts of the concrete, and it delayed the time during which the concrete temperature restored. In addition, for early-frost damages, lower early temperature increased the expansion of frozen water, which in turn relaxes the concrete structures and increases the absorption rate, ultimately extending the depth of early-frost damage.

  • PDF

양생온도 -10℃에서 거푸집 재료 변화에 따른 콘크리트의 압축강도 특성 (Compressive Strength Properties of Concrete by the Form Material Change at 10 below Zero)

  • 최시현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.107-108
    • /
    • 2016
  • When the construction in a low temperature, the concrete performance is deteriorated by frost damage at early age. In this study, the form utilizing heating sheet and insulation is measured the performance to prevent frost damage at 10 below zero. It produced five types of the form and to measure the temperature history and compressive strength. At first, form attached heating sheet showed the highest temperature. But the form attached vacuum insulation showed the highest temperature ever since 12hours. In the case of compressive strength, the form attached heating sheet + isopink(polystyrene foam board) showed the highest compressive strength. It was followed by vacuum insulation. As a result, the form utilizing insulation and heating sheet helped to prevent frost damage.

  • PDF

초음파 주파수분석법에 의한 발전소 고온배관재료의 크리프손상 평가 (Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Ultrasonic Frequency Analysis Spectrum Method)

  • 정민화;이상국
    • 한국해양공학회지
    • /
    • 제13권2호통권32호
    • /
    • pp.90-98
    • /
    • 1999
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operationg conditions like high temperature and high pressure for an extended period time. Such material degradation lead to various component faliures causing serious accidents at the plant. Conventional measurement techniques such as replica method, electric resistance method, and hardness test method have such disadvantages as complex preparation and measurement procedures, too many control parameters, and therefore, low practicality and they were applied only to component surfaces with good accessibility. In this study, both artificial creep degradation test using life prediction formula and frequency analysis by ultrasonic tests for their preparing creep degraded specimens have been carried out for the purpose of nondestructive evaluation for creep damage which can occur in high-temperature pipelline of fossil power plant. As a result of ultrasonic tests for crept specimens, we confirmed that the high frequency side spectra decrease and central frequency components shift to low frequency bans, and bandwiths decrease as increasing creep damage in backwall echoes.

  • PDF

이상저온 발생 시점 확인을 위한 알고리즘 패턴 개발 (Development of Algorithm Patterns for Identifying the Time of Abnormal Low Temperature Generation)

  • 이정원;이충호
    • 산업융합연구
    • /
    • 제21권8호
    • /
    • pp.43-49
    • /
    • 2023
  • 2018년부터 기후변화에 따른 폭염과 한파에 의해 사회기반시설에 점증적으로 많은 피해를 미치고 있다. 최근 4년간 기후변화에 따른 영향 중에 냉해에 대한 피해가 매년 증가하여 특정 지역에 국한되었던 피해가 이제는 전국에 걸쳐서 나타나고 있으며, 이를 최소화하기 위한 각계각층의 전문가들에 의한 노력이 집중되고 있다. 그러나 불연속적으로 측정되는 데이터들 속에서 지역 특색을 반영하고자 하는 기존 연구들에서는 갑작스럽게 발생하는 이상 저온에 대한 실시간 관측 연구는 쉽지 않은 상황이다. 본 연구에서는 냉해 발생에 영향을 미치는 기상 데이터를 기준으로 냉해 피해가 발생하였던 시점의 기상 패턴을 탐색한 후 이상저온 발생 시점을 확인할 수 있는 알고리즘 패턴 개발을 하였다. 본 연구의 결과물은 과거의 데이터에 의존하지 않고 실시간으로 발생하는 데이터에 의한 이상저온이 발생한 시점을 시간 시점에서 확인할 수 있다는 점에서 지역적 기상 편차를 의식하지 않고 확인이 가능하다는 점에서, 이상저온 발생 시점 데이터를 확보할 수 있다는 점에서 관련 분야에 많은 도움이 될 것으로 기대할 수 있다.