• Title/Summary/Keyword: low light intensity

Search Result 409, Processing Time 0.032 seconds

Change of photosynthetic efficiency and yield by low light intensity on ripening stage in japonica rice (등숙기의 차광 처리에 의한 광합성능 및 쌀 수량 변화)

  • Lee, Min Hee;Kang, Shin-Gu;Sang, Wan-Gyu;Ku, Bon-Il;Kim, Young-Doo;Park, Hong-Kyu;Lee, Jeom-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.4
    • /
    • pp.327-334
    • /
    • 2014
  • Light intensity is one of the most important requirements for plant growth, affecting growth, development, survival, and crop productivity. Sunlight is the main energy source on Earth which is energy used by photosynthesis to convert light energy to chemical energy. In this study, the light use efficiency and photosynthetic characteristics of high-quality rice cultivars were evaluated after shading on ripening stage. For the study, we treated of three levels of shade (0, 50 and 70%) on rice at ripening stage and two levels of nitrogen (9 and 18 kg/10a) used three high yielding rice cultivars, such as Boramchan, Hopum, and Honong. The shade was given for the respective plots from heading up to harvesting. We were performed to determine growth survey, SPAD and chlorophyll fluorescence every 10 days interval after shading on ripening stage. At harvest stage, grain yield and yield components were determined. Results of analysis of the results representing the maximum photosynthetic efficiency of PSII, Fv/Fm, and SPAD were decreased by depending on the time at full sunlight. But shade treatments were not changed and a significant difference among cultivars did not appear. Compared with the full sunlight, shade treatments significantly delayed ripening rate and decreased rice quality of cultivated rice. Therefore, rice yield, can be reduced in proportion to the shading density is apparent, the rate of decrease was not observed difference between varieties, when protected from light 70%, and decreased to less than 50%. The adverse effects of low light intensity on the yield and yield components were not able to significantly minimize by the nitrogen level.

A Compact Optical System using LED and CMOS Image Sensor for Liver Function Analysis (LED와 CMOS 이미지 센서 기반 간 기능 분석용 소형 광학장치)

  • Kim, Chul;Lim, Chang-Jin;Nam, Myung-Hyun;Kim, Dong-Sik;Seo, Sung-Kyu;Pak, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.270-275
    • /
    • 2012
  • This paper presents a portable and compact optical device which can conveniently be used to perform a functional analysis of human liver function. The proposed system employed red/green LEDs, as a light source, and CMOS image sensor, which is commonly used in cellular phones. With this system, several blood serum samples have been evaluated for liver functional analysis by measuring light absorption level through the blood serum samples depending on aspartate aminotransferase (AST), alanine aminotransferase (ALT), and total bilirubin concentration. The light absorption through the blood serum samples containing AST, ALT, or total bilirubin can provide their concentrations. The green light absorption is more sensitive to the concentration of AST or ALT, and the red light absorption is more sensitive to the total bilirubuin concentration. Additional calibration steps were performed by using a MATLAB program in order to eliminate the light scattering effects from the extraneous particles existing in each blood serum sample. From the blind test, three standard light intensity curves through each enzyme have been obtained and the enzyme concentration values have been compared to those obtained from a commercially available biochemistry analyzer (Toshiba 200 FR). The average percent difference in the obtained concentrations from two systems for AST, ALT, and total bilirubin concentration came out to be 7.79%, 7.98%. and 7.56%, respectively, with the adjusted coefficient of determination (R2) higher than 0.98. This system can possibly lead to a low-cost and simple system that can be used as a point-of-care (POC) system in a condition without advanced equipments.

MICROLEAKAGE IN RESIN COMPOSITE POLYMERIZED WITH VARIOUS LIGHT CURING UNITS (수종의 광중합기에 의한 복합레진 중합시 미세누출에 관한 연구)

  • Park, Sung-Jin;Kim, Dae-Eup;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.604-610
    • /
    • 2005
  • This study was to evaluate the effects of several light curing units on the microleakage of composite resin restorations in primary teeth. The types of curing units were traditional low intensity halogen light(Optilux 360), plasma arc light(Filpo) low heat plasma arc light(Aurys) and high intensity LED(Freelight 2). After preparing cavities on sound primary teeth, cavities were filled with composite resin(Z100) using the same resin bond agent(Scotchbond Multi-Purpose) and were cured with each curing light system. After storing each specimen in sterile water for 24 hours, thermal circulation was done 1,000 times followed by pigmentation using 2% methylene blue solution. Each specimen was sliced and the degree of pigmentation was graded. When microleakage is graded, the average of Aurys was 0.95 which was the lowest and Freelight 2(1.05), Filpo(1.25), Optilux 360(1.30) followed. But values were not shown statistically significant difference (P>0.05). The results suggest that the newly developed curing units which has advantage in children by decreasing discomfort and procedure time can increase the microleakage of the composite resin.

  • PDF

Miniature Biochip Fluorescence Detection System with Spatial Separation of Fluorescence from Excitation Light (형광과 여기광을 공간적으로 분리하는 바이오칩용 소형 형광측정시스템)

  • Kim Ho-seong;Choi Jea-ho;Park Ju-han;Lee Kook-nyung;Kim Yong-Kweon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.8
    • /
    • pp.378-383
    • /
    • 2005
  • We report the development of miniature fluorescence detection systems that employ miniature prism, mirrors and low coat CCD camera to detect the fluorescence emitted from 40 fluorescently-labeled protein patterns without scanner. This kind of miniature fluorescence detection system can be used in point of care. We introduce two systems, one uses prism+mirror block and the other uses prism and two mirrors. A large NA microscope eyepiece and low cost CCD camera are used. We fabricated protein chip containing multi-pattern BSA labeled with Cy5, using MEMS technology and modified the surface chemically to clean and to immobilize proteins. The measurements show that the combination of prism and mirrors can homogenize elliptical excitation light over the sample with higher optical efficiency, and increase the separation between excitation and fluorescence light at the CCD to give higher signal intensity and higher signal to noise ratio. The measurements also show that protein concentrations ranging from 10 ng/ml to 1000 ng/ml can be assayed with very small error. We believe that the proposed fluorescence detection system can be refined to build a commercially valuable hand-held or miniature detection device.

Optimize OTDOA-based Positioning Accuracy by Utilizing Multiple Linear Regression Model under NB-IoT Technology (NB-IoT 기술에서 Multiple Linear Regression Model을 활용하여 OTDOA 기반 포지셔닝 정확도 최적화)

  • Pan, Yichen;Kim, Jaesoo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.07a
    • /
    • pp.139-142
    • /
    • 2020
  • NB-IoT(Narrow Band Internet of Things) is an emerging LPWAN(Low Power Wide Area Network) radio technology. NB-IoT has many advantages like low power, low cost, and high coverage. However low bandwidth and low sampling rates also lead to poor positioning accuracy. This paper proposed a solution to optimize positioning accuracy under the OTDOA(Observed Time Difference of Arrival) approach by utilizing MLR(Multiple Linear Regression) models. Through the MLR model to predict the influence degree of weather(temperature, humidity, light intensity and air pressure) on the arrival time of signal transmission to improve the measurement accuracy. The improvement of measurement accuracy can greatly improve IoT applications based on NB-IoT.

  • PDF

Beam deflection using photorefractive volume grating in Ce-SBN:60 crystal (Ce-SBN:60결정에서 광굴절 부피격자를 이용한 광편향)

  • Ahn, Jun-Won;Kim, Nam;Lee, Kwon-Yeon;Kim, Hye-young;Won, Yong-Hyup
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.315-319
    • /
    • 1997
  • In photorefractive crystals, light deflection is achieved by dynamic photorefractive volume grating, which is induced by the interference of two writing beams. In this paper, we implemented and analyzed the light deflector using Ce-SBN:60 crystals, which is doped with CeO$_2$ and photorefractive effect is induced by low intensity. And we measured maximum coupling coefficient, effective charge density, diffraction efficiency as the intensity ratio and response time.

  • PDF

Effect of Heat-treatment Atmosphere on Photoluminescence of Eu-doped Li-Al-O System (열처리 분위기가 Eu 이온이 첨가된 Li-Al-O계 형광체 특성에 미치는 영향)

  • Kim, Jeong Seog;Cheon, Chae Il;Chae, Ki-Woong
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.1
    • /
    • pp.25-31
    • /
    • 2014
  • New green phosphor is synthesized by reducing $LiAlO_2:xEu^{3+}$ phosphors in a low pressure $H_2$ atmosphere. The $LiAlO_2:xEu^{3+}$ prepared by a solid state reaction method is reported as red phosphor. The effect of the reduction treatment on the $LiAlO_2:xEu^{3+}$ on the crystalline phase change and photoluminescence (PL) property are characterized. The reduced phosphor had a broad green light spectrum centered at 524 nm. The PL intensity of the reduced phosphor increased to a maximum at the reduction temperature of $1100^{\circ}C$. The PL intensity decreased with a further increase in the reduction temperature. The crystalline phase constituting the reduced phosphor varied with the temperature. A new crystalline phase $Li_2Al_4O_7$ was observed at $1100^{\circ}C$. The origin of the green-light emission is discussed in relation to the crystalline phase change.

Malaysian Vehicle License Plate Recognition in Low Illumination Images (저 조도 영상에서의 말레이시아 차량 번호판 인식)

  • Kim, Jin-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.10
    • /
    • pp.19-26
    • /
    • 2013
  • In the Malaysian license plates, alphabets and numerals which are made by plastic, are adhered to a frame as embossing style and occasionally characters in horizontal, vertical directions are aligned with narrow space. So the extraction of character stroke information can be hard in the vehicle images of low illumination intensity. In this paper, Malaysian license plate recognition algorithm for low illumination intensity image is proposed. DoG filtering based character stroke generation method is introduced to derive exact connected components of strokes in the vehicle image of low illumination intensity. After localization of plate by connected component analysis, characters are segmented and recognized. Algorithm is experimented for the 6,046 vehicle images captured in Kuala Lumpur by IR camera without using any special light during day and night. The experimental results show that recognition accuracy of plates is 96.1%.

LED Headlight, Safety and Application in Oral Surgery (구강 수술에 사용가능한 LED 헤드라이트의 안전성 및 실용성)

  • Yoo, Young-Sam;Heo, Geon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.2
    • /
    • pp.187-192
    • /
    • 2010
  • Background and Objectives : LED(Light emitting diode) is recently introduced as a energy-saving light source in many area including agriculture and environment. In medical field it is known as bright and safe light source in surgical lighting including headlight. This study is aimed to test effectiveness and cost-saving of mountain-climbing headlight in comparison with xenon headlight. Materials and Methods : Internet market-available mountain-climbing headlight was compared with medical xenon headlight regarding heat generation after 30 minutes' usage, intensity of illumination and possible burn to the perioral skin. To get temperature data, 5 cases of tonsillectomy were done with the aid of LED headlight, while another 5 tonsillectomies were done using xenon headlight. Results : The temperatures of all light sources were below 45 degrees Celcius until finish of the surgery without burn or complications. No differences in operation time with both headlights. The maximal intensities of illumination were 24000 Lux for xenon, 20000 Lux for LED. Conclusion : Mountain-climbing headlight could be safe and helpful light source with low cost in simple oral surgery.

Spatio-temporal variabilities of nutrients and chlorophyll, and the trophic state index deviations on the relation of nutrients-chlorophyll-light availability

  • Calderon, Martha S.;An, Kwang-Guk
    • Journal of Ecology and Environment
    • /
    • v.39 no.1
    • /
    • pp.31-42
    • /
    • 2016
  • The object of this study was to determine long-term temporal and spatial patterns of nutrients (nitrogen and phosphorus), suspended solids, and chlorophyll (Chl) in Chungju Reservoir, based on the dataset of 1992 - 2013, and then to develop the empirical models of nutrient-Chl for predicting the eutrophication of the reservoir. Concentrations of total nitrogen (TN) and total phosphorus (TP) were largely affected by an intensity of Asian monsoon and the longitudinal structure of riverine (Rz), transition (Tz), and lacustrine zone (Lz). This system was nitrogen-rich system and phosphorus contents in the water were relatively low, implying a P-limiting system. Regression analysis for empirical model, however, showed that Chl had a weak linear relation with TP or TN, and this was mainly associated with turbid, and nutrient-rich inflows in the system. The weak relation was associated with non-algal light attenuation coefficients (Kna), which is inversely related water residence time. Thus, values of Chl had negative functional relation (R2 = 0.25, p < 0.001) with nonalgal light attenuation. Thus, the low chlorophyll at a given TP indicated a light-limiting for phytoplankton growth and total suspended solids (TSS) was highly correlated (R2 = 0.94, p < 0.001) with non-algal light attenuation. The relations of Trophic State Index (TSI) indicated that phosphorus limitation was weak [TSI (Chl) - TSI (TP) < 0; TSI (SD) - TSI (Chl) > 0] and the effects of zooplankton grazing were also minor [TSI (Chl) - TSI (TP) > 0; TSI (SD) - TSI (Chl) > 0].