• 제목/요약/키워드: low humidity

검색결과 1,034건 처리시간 0.221초

하계 남성복의 온열쾌적감에 관한 연구 - 실내 환경조건을 중심으로 - (A Study on Thermal Comfort of Korea Men감s Wear in Summer - Based on Indoor Environment conditions -)

  • 정상열;고경태
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 1997년도 추계총회 및 학술발표회 논문집
    • /
    • pp.364-368
    • /
    • 1997
  • The purpose of this Study was to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate Variability(HRV), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at 50% R.H., 24C, and the difference of skin temperature was found at the calf area as air temperature changes. At low air temperature and low humidity, heart rate was decreased, but there was no change at brain wave, keeping a-wave.

  • PDF

상온저장 시설의 환경 제어 시스템 개발 (Development of an Environmental Control System for Agricultural Storage Facility)

  • 임종환;현명택
    • 한국식품저장유통학회지
    • /
    • 제4권2호
    • /
    • pp.101-113
    • /
    • 1997
  • Temperature, relative humidity and ventilation are closely related one another, and they are the main factors to be controlled for the environmental control system of a storage facility. Conventional environmental control systems do not consider the interrelationship between temperature, relative humidity and ventilation, which results in low performance and high energy consumption. To overcome the inefficiency of the conventional ones, it was developed an on-off control system based on the interrelationship between the factors. The usefulness of the system was illustrated with the results produced by a set of experiments in a real world.

  • PDF

DEVELOPMENT OF AN AUTOMATIC ENVIRONMENTAL CONTROL SYSTEM FOR LOW TEMPERATURE STORAGE HOUSE USING INTERNET

  • Chung, H.;Yun, H.S.;Lee, W.O.;Lee, K.H.;Cho, Y.K.;Park, W.K.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.676-683
    • /
    • 2000
  • For high quality storage of agricultural products, temperature, humidity and gas conditions in a storage house should be controlled properly. But most of the low temperature storage house is depending on temperature control. This study aimed to develop an automatic control system for low temperature storage house that can control storage conditions such as temperature, humidity and $CO_2$ gas concentration. The developed system alarms the user, by telephone or beeper, when abnormal condition has occurred. The farmer can also monitor the inside condition of warehouse in his residence, by Internet. From the results of the performance test, the temperature and relative humidity in the warehouse is controlled within the range of ${\pm}0.5^{circ}C$ and ${\pm}2%$, respectively.

  • PDF

초극소 저출생체중아의 고농도 가습환경 유지를 위한 근거중심 프로토콜 개발 (Development of evidence-based protocol to maintain high humidity of incubator in Extremely Low Birth Weight Infant)

  • 유미;최윤진;한리라;윤영미;배근하;이지은;박지선;박의
    • 중환자간호학회지
    • /
    • 제2권2호
    • /
    • pp.5-17
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate the current humidification state of incubator, the factors disturbing high humidification and to establish the evidence-based nursing protocol to maintain it. Methods: The subjects were 15 infants who were born with extremely low birth weight (ELBW) from May to October, 2007, and data were collected during the first 3 days and analyzed with SPSS WIN program. Results: The goal of humidity level in incubator was 95%, but mean humidity levels were 89.7%(1st day), 91.9%(2nd day), and 91.8%(3rd day)(p<0.001). The disturbing factors were opening frequency and duration of incubator door and window by caregivers. The handling of infants by nurses and doctors happened more frequently during the first day. Especially, nurses handled them more often than others, but the duration of opening during the invasive procedures by doctors was longer than others. The opening frequency had negative correlation with duration(r=-.779, p<.01). Conclusion: So the evidence-based protocol for maintaining high humidity in incubator for ELBW infants during the first 3 days and next 2 days was made. Furthermore we need to educate NICU nurses and doctors about minimal handling.

  • PDF

다공질 실리콘 양극산화막의 형성과 감습특성 (Formation and Humidity-Sensitive Characteristics of Anodically Oxidized porous Silicon Films)

  • 최복길;이동희;유지호;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1066-1068
    • /
    • 1995
  • The formation properties and oxidation mechanism of electrochemically oxidized porous silicon(OPS) films have been studied. To examine the humidity-sensitive properties of OPS films, surface-type and bulk-type humidity sensors were fabricated. The oxidized thickness of porous silicon layer(PSL) increases with the charge supplied during electrochemical oxidation and current density. The humidity sensor shows high sensitivity at high relative humidity in low temperature. The sensitivity and linearity can be improved by increasing a porosity of PSL.

  • PDF

여름철 냉방시 상대습도가 쾌적감에 미치는 영향(청년과 고령자의 비교를 중심으로) (Effects of relative humidity on comfort sensation by comparison between the young and the aged)

  • 김동규;금종수;최광환;박희욱;김종열;주익성
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.381-388
    • /
    • 1998
  • Hot and humid weather in summer generally brings about discomfort. Experiments on which relative humidity makes effects on the comfort sensation were performed to the young and the aged using sensation vote. From July to October 1996, seven college students and eleven aged people were exposed for 2 hours under six different conditions in the Pukyong National University test chamber so as to determine the effects of relative humidity on thermal and comfort sensations. Subjects were wearing same clothes, and the mean clo value was 0.5. The mean radiant temperature was equal to the air temperature and air velocity in the occupied zone around 0.lm/s. In the experiments, it was found that discomfort could be largely reduced when the humidity is controlled to low values in the settled high temperature.

  • PDF

기능성 골판지 포장재 KS규격표준화연구 (A Study on the KS standardization of functional corrugated fibreboard)

  • 이용무
    • 기술표준
    • /
    • 통권12호
    • /
    • pp.67-78
    • /
    • 2003
  • In order to keep a characteristic corrugated fibreboard of fruits and flowers, temperature and humidity change of corrugated fibreboard are analyzed. According to relative humidity rises at fixed temperature, bursting strength of corrugated fibreboard was fallen and double wall corrugated fibreboard appeared greatly the bursting strength decline rate than double faced corrugated fibreboard and edgewise compressive strength of paper more than humidity 80% in rapidly fall. A column crush test of paper became decrease in the high temperature and ordinary temperature strength did over humidity 70% rapidly fallen and strength decrease happened by low temperature 80% slowly fallen and later rapidly. According to ISO standard temperature humidity conditioning (23$\pm$2 , 50$\pm$2%) change, pulp composition difference as to the ring crush strength of a physical strength and generally compare to KS standard increased 5∼8% for the compressive strength, and wet strength reagent was increased 4% inside and out.

  • PDF

폴리이미드 박막과 스퍼터링 방법으로 증착한 상부금속 그레인이 용량형 습도센서의 전기적 특성에 미치는 영향 (Effects of the Electrical Characteristics of Capacitive Relative Humidity Sensor by Polyimide Film and Upper Electrode Grain by Sputtering Method)

  • 이진민
    • 한국전기전자재료학회논문지
    • /
    • 제24권3호
    • /
    • pp.224-228
    • /
    • 2011
  • This research, integratable capacitive relative humidity sensor was produced using polyimide on glass substrate. Also, at the time of upper electrode formation, upper electrode grain size was affected by giving changes to sputtering condition. Through this analyzing electrical characteristics affect from capacitive relative humidity sensor was possible. Capacitance of capacitive relative humidity sensor was 330 pF, linearity of 0.6%FS and it showed less than 3% of low hysterisis. Specially, hysterisis was affected more from interface than interstitial. Also was affected by the grain size which is one of the formation condition of upper electrode.

A spectroscopic study of the effect of humidity on the atmospheric pressure helium plasma jets

  • Han, Duksun
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1375-1380
    • /
    • 2018
  • Atmospheric-pressure plasma has a great potential in many applications due to its simplicity rather than low pressure plasmas. In material processing, biomedical applications, and many other applications, the input power, gas flow rate, and the geometry of electrode have been mainly considered and studied as important external parameters of atmospheric-pressure plasma control. Besides, since the atmospheric-pressure plasmas are typically generated in an open air, the relative humidity is difficult to control and can change day by day. Therefore, the relative humidity cannot be ignored for plasmas. Thus, in this work, the atmospheric-pressure plasma jet was characterized by changing relative humidity, and it was found that the increase in electron density and OH radicals are due to Penning ionization between helium metastable and water vapors at higher humidity condition.

확산 포집기로 공기중 혼합유기용제 포집시 온도와 상대습도가 포집효율에 미치는 영향 (Effects of temperature and relative humidity on the sampling efficiencies of mixed organic vapors measured by diffusion monitors)

  • 한진구;노영만;김현욱
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.200-211
    • /
    • 1995
  • This study was designed to evaluate the effects of temperature and humidity on the sampling efficiency of mixed organic vapors of l,2-DCE, benzene, and MIBK by 3 different types of diffusion monitors. Independent variables used for the study were temperatures ($25^{\circ}C$, $35^{\circ}C$), humidities (30%, 80%), and vapor concentrations (low, medium, and high). In addition, vapor concentrations measured by the traditional charcoal tube method were used as reference values and were compared with those of by diffusion monitors. The results were as follows: 1. The desorption efficiencies(DE) of 1,2-DCE and benzene from charcoal tubes and from diffusion monitors ranged from 98% to 105%. In contrast, the DEs of MIBK from charcoal tubes and diffusion monitors except DM1 ranged from 71% to 85%. The DE of MIBK from DM1 was 98%. 2. No statistically significant differences of 1,2-DCE concentrations and the sampling efficiencies regardless of temperatures and humidities studied between charcoal tube and 3 diffusion monitors were found. 3. At 80% humidity, increasing frequencies of 1,2-DCE breakthrough at higher temperature and higher vapor concentration measured by charcoal tubes were observed. 4. No statistically significant difference of benzene concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly lower at all experimental conditions except the $35^{\circ}C$ and 30% humidity condition. 5. No statistically significant difference of MIBK concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly higher at higher humidity conditions regardless of temperature. Although statistically not significant, sampling efficiency of MIBK showed positive correlation with humidity while negative correlation with concentration was observed. 6. For sampling 1,2-DCE and benzene, no significant variations of concentrations among three diffusion monitors regardless of temperature and humidity conditions were found. For MIBK sampling, however, wide variations with increasing humidity among diffusion monitors were obtained. In conclusion, this study suggests that diffusion monitors will be a reasonables substitute for the traditional charcoal tubes for sampling non-polar organic vapors at temperature and humidity conditions studied. For polar organic vapors, use of an alternative desorption solution other than CS2 is recommended because of its low desorption efficiency. In addition, since variable among diffusion monitors for polar organic vapors particularly at higher humidity conditions were observed, further study is recommended of the effects of humidity on the performance of diffusion monitors.

  • PDF