• 제목/요약/키워드: louver

검색결과 134건 처리시간 0.028초

외피 친환경 성능평가 II: 광선반, RetroLux (Performance Assessment of Building Envelopes II: LightShlef, RetroLux)

  • 김덕우;박철수
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.83-90
    • /
    • 2009
  • As a series of 'Performance Assessment of Building Envelopes I: Double Skin Facade', three types (interior, exterior, mixed (int.&ext.)) of lightshelves and RetroLux were examined in terms of $CO_2$ emissions. It is shown that the exterior lightshelf could achieve the most energy savings (9.6-38.7%) in general office buildings due to blocking solar radiation before entering the indoor space. However, the interior lightshelf is the worst (1.4-5.2%) among three of them. The RetroLux has two components: (1) sun-reflector (first louver component), (2) light shelf for improving daylight induction (second louver component). Due to these two components, solar radiation from windows is filtered depending on seasonal variation (solar altitude). Therefore, the RetroLux can reduce 18.0-27.9% of annual energy consumption (both cooling and heating), and $552-3,290Won/m^2{\cdot}yr$ of operation cost is saved.

  • PDF

자동차 에어컨용 평행류 응축기의 성능평가 (Performance Evaluation of a Parallel Flow Condenser for Automotive Air Conditioners)

  • 장혁재;강병하
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.247-253
    • /
    • 2003
  • The new shape of louver-fin has been applied to a parallel flow condenser to enhance air-side heat transfer rate lot an automotive air-conditioner R- l34a is employed as a refrigerant inside the flat tube of the condenser, This problem is of particular interest in reducing the geometric size of the automotive air conditioner The effect of air flow rate on pressure drop as well as heat transfer in air side are studied in detail. Comparison of the performance is also made with that of a conventional parallel flow condenser, which is available in the market. The results obtained indicate that the total pressure drop through the pre sent condenser is not changed, while the heat transfer rate is increased by 24% at high veto city of air flow, compared with those of the conventional condenser. The parallel flow condenser with a new shape of louver-fin could be reduced in size by 20% for the equivalent condenser capacity, compared with the conventional parallel flow condenser.

경사지게 설치된 평행류형 알루미늄 열교환기의 공기측 전열 성능 (Air-side Performance of Aluminum Heat Exchangers at Different Inclination Angles)

  • 김도영;조진표;김내현;박내현;황준현
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.181-188
    • /
    • 2008
  • The effect of inclination angle on the heat transfer and pressure drop characteristics of the brazed aluminum heat exchangers is experimentally investigated. Three samples having different fin pitches(1.25, 1.5 and 2.0 mm) were tested. Results show that heat transfer coefficient is not affected by the inclination angle. However, the friction factor increases as the inclination angle increases with negligible difference between the forward and backward inclination. Both the heat transfer coefficient and the friction factor are the smallest at $F_p=1.5mm$, followed by $F_p=2.0mm$ and 1.25mm. Possible explanation is provided considering the louver layout. Comparison with existing correlations is also made.

다양한 막냉각 홀 형상에 대한 막냉각 효율의 수치해석 (NUMERICAL STUDY ON FILM-COOLING EFFECTIVENESS FOR VARIOUS FILM-COOLING HOLE SCHEMES)

  • 김선민;이기돈;김광용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.104-111
    • /
    • 2011
  • To protect the turbine blade, many cooling techniques has developed. With all other things, film-cooling has been widely used as the important alternative. In the present work, numerical analysis has been performed to investigate and to compare the film-cooling performance of various film-cooling hole schemes such as cylindrical, crescent, louver, and dumbbell holes. To analyze the turbulent flow and the film-cooling mechanism, three-dimensional Reynolds-averaged Navier-Stokes analysis has been performed with shear stress transport turbulence model. The validation of numerical results has been assessed in comparison with experimental data. The characteristics of fluid flow and the film-cooling performance for each shaped hole have been investigated and evaluated in terms of centerline, laterally averaged and spatially averaged film-cooling effectivenesses. The dumbbell shaped hole shows better film-cooling effectiveness than other shaped holes. And the louver and cylindrical shaped hole shows lower one, and concentrated flow on centerline only.

  • PDF

저 착상 휜과 두 대 압축기 사이클을 이용한 히트펌프 난방성능 개선에 관한 연구 (The Experimental Study on Performance Improvement under frost conditions of the Heat Pump with Corrugate Shaped Fin and Two Compressors)

  • 황윤제;조은준;정백영;이감규
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.201-208
    • /
    • 2005
  • This study presents the experimental study on improvement of frost/defrost performance in an heat pump system with newly developed fin and multiple compressors. As multiple compressors system, the variable and single speed compressor combinations has been introduced and compared with single speed 1-compressor system in a view point of improvement of frost/defrost performance. Also, newly developed corrugate shaped fin has been compared with conventional louver shaped fin. The frost/defrost performance is defined and some parameters are compared to discuss the effect of each combination. From this experimental study, it is known that if the variable and single speed compressor combination system equipped with corrugate shaped fin, the system performance has greatly improved not only for heating capacity, but also for frost performance.

경사각이 PF 열교환기의 열전달 및 압력 손실에 미치는 영향 (Effect of Inclination Angle on the Heat Transfer and Pressure Drop Characteristics of Parallel Flow Heat Exchanger)

  • 김도영;함정호;김내현;박내현;황준현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.222-228
    • /
    • 2007
  • The effect of inclination angle on the heat transfer and pressure drop characteristics of brazed aluminum heat exchangers is experimentally investigated. Three samples having different fin pitches (1.25, 1.5 and 2.0 mm) were tested. Results show that heat transfer coefficient is not affected by the inclination angle. However, the friction factor increases as the inclination angle increases with negligible difference between the forward and backward inclination. Both the heat transfer coefficient and the friction factor are the smallest at $P_f$=1.5mm, followed by $P_f$=2.0mm and 1.25mm. Possible explanation is provided considering the louver layout. Comparison with existing correlations is also mad.

  • PDF

다수의 냉각탑이 설치된 옥상에서 냉각탑별 재유입률 예측 (Prediction of Reentering Ratio of Individual Cooling Towers Scattered on a Building Roof)

  • 이태구;문선애;유호선;이재헌
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.923-932
    • /
    • 2006
  • In this paper, reentering ratio and cooling capacity of individual cooling towers arrayed on a building roof were studied by a numerical method. The number of 16 cooling towers were divided into 4 banks. It was considered the summer prevailing wind characteristics as west wind and south wind of 5 m/s. It was also considered the roofwall types as the curtainwall and the louverwall that had the outdoor air intake louver in the curtainwall. In this case, the louver was suggested as the solution that could prevent reentering phenomenon due to recirculation and interference of the discharge air. In the case of the curtainwall, the averaged reentering ratio are predicted 13.3% and 24.4% for the west and south wind of 5 m/s, respectively. In the case of the louverwall, the averaged reentering ratio are predicted 2.5% and 9.7% for the west and south wind of 5 m/s, respectively. Therefore, the louverwall is a appropriate solution for reducing the reentering phenomenon.

SiO2/SiON 다층박막 적용 투명보안필름의 광특성 연구 (Optical Characteristics of Transparent Privacy Film with SiO2/SiON Multi-Layer)

  • 성형석;권진구;채희일;한현성;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.287-295
    • /
    • 2019
  • Privacy films are typically manufactured by combining black resin and transparent louver-shaped patterns. The use of black resin results in excellent light-shielding. However, black resin can reduce the transmittance of privacy films at the front viewing angle. In this study, we applied $SiO_2/SiON$ multi-layer thin films on a privacy film to maintain transmittance at the front viewing angle and improve light-shielding at the side viewing angle. We determined the optimum combination of thicknesses of the $SiO_2/SiON$ multi-layer stacks to increase the overall transmittance; the light shielding could be maximized at the side viewing angle.

자동차용 에어컨의 마이크로채널 응축기의 수치적 모델 개발 (Numerical Model Development of a Microchannel Condenser for Mobile Air-Conditioning Systems)

  • 쉐흐리야 이샤크;나비드 울라;최준호;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.430-436
    • /
    • 2022
  • This paper presents the numerical model development of a microchannel heat exchanger in mobile air-conditioning and heat pump applications. The model has been developed based on the effectiveness-NTU method using a segment-by-segment modeling approach. State-of-art correlations are used for refrigerant- and air-side heat transfer coefficients and pressure drops. The calculated heat condenser capacities are in good agreement with experimental data, with an average difference of 1.86%. The current model can be used for microchannel condenser simulations under various operating conditions. It is anticipated to improve productivity in designing and optimizing microchannel heat exchangers with folded louver fin geometry.

철도용 터널형 방음벽 개발연구: 설계 방향 (Noise Protection Roof: Partial Opening Effect for Noise Reduction)

  • 김태민;김정태
    • 한국철도학회논문집
    • /
    • 제18권6호
    • /
    • pp.522-532
    • /
    • 2015
  • 본 연구에서는 철도 교량 위를 주행하는 철도 소음에 의한 고층 공동주택 거주민들의 철도 소음 피해를 최소화할 뿐 아니라, 방음시설에 미치는 풍하중 및 자중을 동시에 감소시키는 방안으로 터널형 방음벽의 벽면부 개방을 검토하였다. 광음향기법, 전산 유체 역학 및 구조 역학을 이용하여 방음 효과, 유동 효과 및 구조 경량화가 고려된 터널형 방음벽 설계 및 효과를 예측하였다. 해석결과, 벽면부를 부분 개방하여 경량화 및 풍하중 감소 효과를 얻을 수 있었으며, 방음시설의 풍하중은 최대 30% 감소되었다. 부분 개방으로 인해 철도소음의 피해가 특정 높이에서 증가하기 때문에 이를 보완하기 위하여 개방된 부분에 소음기 형태의 음향 루우버 설치를 검토하였다. 음향 루우버의 경우 기존 방음재료의 차음성능과 유사한 성능이 존재하도록 개공율에 따른 유동 해석과 차음성능 해석을 수행하였다. 개공율 30~40% 개방 시, 차음성능 10dB를 만족하며 풍하중이 약 25% 저감되는 것으로 분석되었다. 결과적으로 터널형 방음벽의 벽면부 개방과 음향 루우버 설치는 경량화 및 풍하중에는 긍정적인 효과를 보여주며, 부분 개방과 함께 적절한 방음 재료와 방음설계가 동시에 적용될 경우, 거주민들이 요구하는 5-10dB 수준의 소음저감 효과가 나타나는 것으로 분석되었다.