• 제목/요약/키워드: loss of pipe material

검색결과 25건 처리시간 0.026초

흡음형 소음기를 사용한 세차기용 원심송풍기의 소음저감에 관한 연구 (Noise Reduction of a Blower for an Automatic Car Washer by Using Dissipative Silencers)

  • 김재영;이일재
    • 한국소음진동공학회논문집
    • /
    • 제21권8호
    • /
    • pp.726-732
    • /
    • 2011
  • Straight absorptive silencers have been designed to reduce the noise level of a centrifugal blower. Three-dimensional boundary element method is used for the design of absorptive silencers which consist of a perforated main pipe and a outer chamber filled with fibrous material. The experimental results show that the absorptive silencer reduces up to 8 dB(A) in the overall sound pressure level of the blower and up to 15 dB at the blade passing frequency. It is also found that the gap between the silencer and the impeller may substantially alter the acoustic performance of the silencers. The transmission loss predicted by the boundary element method follows overall trends of the measured insertion loss. The experiments also show that the impact of the silencers on the aerodynamic performance of the blower is minimum.

흡음재 물성치 변화에 따른 소음기 음향성능 연구 (A study on the acoustic performance of a silencer according to the change of properties of absorbing material)

  • 이용범;양해상
    • 한국음향학회지
    • /
    • 제40권4호
    • /
    • pp.278-289
    • /
    • 2021
  • 본 연구에서는 함정에서 발생하는 배관소음을 줄이기 위해 크기 대비 성능이 우수한 흡음형 소음기의 음향성능을 수치해석 방법을 이용하여 예측 및 분석하였다. 이를 위해 단일확장형 소음기의 음향성능을 실험 및 수치해석 방법을 이용하여 검증하였다. 음향성능은 자체 성능을 나타내는 지표인 투과손실을 이용하여 나타내었고, 실험은 배관 끝단 임피던스를 바꿔서 측정하는 two-load method를 통해 결과를 도출하였다. 수치해석은 범용 유한요소해석 프로그램을 사용하여 실시하였고, 흡음재 유동저항을 입력 매개변수로 하는 Delany-Bazley-Miki 모델을 적용하였다. 최종적으로, 단순확장형 및 흡음형 소음기 음향성능 각각에 대한 실험·모의 결과를 비교하여 결과의 일치성을 확인하였으며, 흡음재 물성치에 따라 4가지 경우로 분류하여 각각에 대한 시뮬레이션 결과를 예측 및 분석하였다.

상수관의 세척을 위한 회전식 스왑피그 공법 개발 (Development of a Rotation Swab Pig Method for Cleaning Water Pipes)

  • 이기철;김재호;김기성;박정준
    • 한국지반신소재학회논문집
    • /
    • 제23권2호
    • /
    • pp.63-75
    • /
    • 2024
  • 마시는 물은 인간의 기본적인 생활권 보장을 위한 필수적 요소로 깨끗한 물에 대한 품질은 항상 확보되어야 한다. 하지만 국내 수도시설을 집중 설치하였던 2000년 초반을 기점으로 현재 노후 상수도 시설이 증가하고 있으며, 색도 및 탁도와 같은 물의 변색, 이물질 누출 등의 사고가 빈번히 발생하고 있다. 실제로 모든 관의 교체는 불가능하기 때문에 2021년 제정된 상수관망시설 유지관리업무 세부기준에서는 상수관 세척을 의무화 하였으며, 다양한 세척 공법들을 통해 유지관리가 이루어지고 있는 실정이다. 상수관 세척 공법 중 스왑피그 공법은 관 내 이물질을 물리적으로 제거하는 방법으로 세척 효율이 가장 높은 것으로 평가 받고 있다. 하지만, 세척과정에서 스왑피그의 파손 및 변형에 따라 세척 효율은 변화하며, 분실의 가능성이 존재한다. 따라서 본 연구에서는 피그 자체의 재료를 변경하여, 압축력 및 관 내벽과의 밀착력을 향상시키고자 하며, 세척 효율 극대화를 위해 회전 블레이드를 삽입된 회전식 스왑피그를 개발하였다. 또한, 분실 가능성을 제거하고, 피그의 위치 파악을 위해 고강도 와이어 및 권취 장치를 추가적으로 개발하여, 투입구부터 토출구까지를 연결하였다. 각 세부 기술의 성능 검증 이후에는 30m 구간의 테스트베드에서 본 기술을 적용하였으며, 현장 적용성 평가와 더불어 공정 시간을 측정하여 기술의 성능을 검증하였다.

유체유동에 의한 복합재료 파이프의 안정성 해석 (Stability Analysis of Composite Material Pipes Conveying Fluid)

  • 최재운;송오섭
    • 한국소음진동공학회논문집
    • /
    • 제11권8호
    • /
    • pp.314-321
    • /
    • 2001
  • Static and oscillatory loss of stability of composite pipes conveying fluid is Investigated. The theory of than walled beams is applied and transverse shear. rotary inertia, primary and secondary warping effects are incorporated. The governing equations and the associated boundary conditions are derived through Hamilton's variational principle. The governing equations and the associated boundary conditions are transformed to an eigenvlaue problem which provides the Information about the dynamic characteristics of the system. Numerical analysis is performed by using extended Gelerkin method. Variation of critical velocity of fluid with fiber angles and mass patios of fluid to pipe Including fluid is investigated.

  • PDF

함정의 해수 배관소음 저감을 위한 흡음형 소음기 연구 (A Study on the Absorptive Silencer for Reducing Noise Propagate in Seawater Pipes on Ship)

  • 서영수;박경훈;전재진
    • 한국소음진동공학회논문집
    • /
    • 제23권8호
    • /
    • pp.770-776
    • /
    • 2013
  • Fluid-borne noise produced by seawater circulating pumps propagates through the seawater connected pipes and radiates from the hull opening of a ship. This noise causes the increases of underwater radiated noise and self noise of ship. To reduce the noise propagation through the seawater connected pipes, absorptive silencer must be needed. In this paper, theoretical model to analyze the transmission loss of absorptive silencer was presented and the design parameters of absorptive silencer were verified. Theoretical calculations were performed according to a thickness, a length, an internal pressure and mechanical properties of its absorptive material in order to analyze the characteristics of absorptive silencer. From the theoretical calculation results, the absorptive silencer was manufactured and transmission loss was measured in the test facilities. The results of theory and measurement are compared and discussed.

에너지 축열보드 열해석을 위한 컴퓨터 수치해석 (Computer Simulation for the Thermal Analysis of the Energy Storage Board)

  • 강용혁;엄태인;곽희열
    • 에너지공학
    • /
    • 제8권2호
    • /
    • pp.224-232
    • /
    • 1999
  • 캡슐형 잠열재를 이용한 열저장 시스템은 바닥 난방 및 건물 난방에서 매우 효과적인 시스템이다. 이러한 시스템 개발에 필수적인 요소가 열유동 매체가 순환하는 파이프 주변의 캡슐내 온도 분포와 열유동 매체의 유량 등이다. 그러므로 본 연구에서는 3차원 비정상 상태에서 Navier-Stokes 방정식, 난류모델을 비롯한 스칼라 보존 방정식을 적용하여 캡슐 블록의 온도 분포 및 파이프 내의 유동장 해석을 수행하였다. 또한 본 연구와 같이 계산 영역이 특별한 기하학적 현상을 형상(circle+square)인 문제 해결하는데 적용할 수 있는 새로운 격자 생성 기술(MBFGE/CCM)을 개발하였다. 격자계는 파이프에서 원형 격자를 이용하였고, 캡슐 블록에서 사각 격자를 이용하여 다중격자와 미세격자를 결합하여 사용하였다. 본 연구의 목적은 컴퓨터를 이용한 수치해석적 방법을 미세 캡슐을 이용한 축열보드에 적용하여 2종류의 열경계 상태에 대하여 속도와 온도분포를 계산하여 비교분석을 하는 것이다. 온도는 축열 보드의 한 쪽면은 대류면이고 다른 한쪽면은 단열면인 경우(Case 2)보다 양면 모두 단열인 경우(Case 1)일 때 더 높게 상승하였다. 온수 파이프 중심선인 Y=0 에 가까운 영역에서 Case 1과 Case 2사이에 축열 보드 내에서 온도 차이는 확연하게 나타났다. 향후 수치해석의 정확도를 높이고 축열 보드의 열전달 현상을 보다 정확히 계산하기 위해서는 위치 및 시간에 따른 정밀한 온도 측정값이 필요하고 특히 잠열재인 미세 캡슐이 상변화를 하므로 온도 변화에 따른 물질의 비열(C$_{p}$)과 열전달율(λ)을 고려한 방정식이 요구된다.

  • PDF

Three-dimensional numerical parametric study of tunneling effects on existing pipelines

  • Shi, Jiangwei;Wang, Jinpu;Ji, Xiaojia;Liu, Huaqiang;Lu, Hu
    • Geomechanics and Engineering
    • /
    • 제30권4호
    • /
    • pp.383-392
    • /
    • 2022
  • Although pipelines are composed of segmental tubes commonly connected by rubber gasket or push-in joints, current studies mainly simplified pipelines as continuous structures. Effects of joints on three-dimensional deformation mechanisms of existing pipelines due to tunnel excavation are not fully understood. By conducting three-dimensional numerical analyses, effects of pipeline burial depth, tunnel burial depth, volume loss, pipeline stiffness and joint stiffness on bending strain and joint rotation of existing pipelines are explored. By increasing pipeline burial depth or decreasing tunnel cover depth, tunneling-induced pipeline deformations are substantially increased. As tunnel volume loss varies from 0.5% to 3%, the maximum bending strains and joint rotation angles of discontinuous pipelines increase by 1.08 and 9.20 times, respectively. By increasing flexural stiffness of pipe segment, a dramatic increase in the maximum joint rotation angles is observed in discontinuous pipelines. Thus, the safety of existing discontinuous pipelines due to tunnel excavation is controlled by joint rotation rather than bending strain. By increasing joint stiffness ratio from 0.0 (i.e., completely flexible joints) to 1.0 (i.e., continuous pipelines), tunneling-induced maximum pipeline settlements decrease by 22.8%-34.7%. If a jointed pipeline is simplified as a continuous structure, tunneling-induced settlement is thus underestimated, but bending strain is grossly overestimated. Thus, joints should be directly simulated in the analysis of tunnel-soil-pipeline interaction.

공동주택 지역난방 수질기준 설정에 관한 연구 (A Development of the Guideline for the Heating Water Quality in Apartment Houses with District Heating System)

  • 김용기;이태원;우달식;오준;안창구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.493-498
    • /
    • 2008
  • Particles or deposit formed by corrosion of the pipe material bring about bad influences on the heating systems with inconvenience, energy loss and so on. In order to obtain the non-corrosive environments, the circulation hot water should properly be treated in several ways to satisfy one or more conditions of the followings: suitable pH-level, low hardness, low oxygen content, low conductivity, low level of chlorides and sulphur compounds and low level of solid particles. This experimental study was carried out to develope the new guidelines on the optimal water quality and directions for water quality management in heating systems. As results, it was recommended that the heating water be maintained pH-level not less than 8, hardness contents as $CaCO_3$ no more than 50 mg/L, turbidity no more than 10 NTU and T-Fe contents 1 mg/L below.

  • PDF

발전소 온배수를 적용한 대규모 시설원예단지용 난방시스템의 열원이송 배관 재질 및 거리에 따른 성능평가 (Effects of Pipe Network Composition and Length on Power Plant Waste Heat Utilization System Performance for Large-scale Horticulture Facilities)

  • 이금호;이재호;이광호
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권4호
    • /
    • pp.14-21
    • /
    • 2015
  • Korean government plans to establish large-scale horticulture facility complexes using reclaimed land in order to improve the national competitiveness of agriculture at the government level. One of the most significant problems arising from the establishment of those large-scale horticulture facilities is that these facilities still largely depend on a fossil fuel and they require 24 h a day heating during the winter season in order to provide the necessary breeding conditions for greenhouse crops. These facilities show large energy consumption due to the use of coverings with large heat transmission coefficients such as vinyl and glass during heating in the winter season. This study investigated the applicability of waste heat from power plant for large-scale horticulture facilities by evaluating the waste heat water temperature, heat loss and energy saving performance as a function of distance between power plant and greenhouse. As a result, utilizing power plant waste heat can reduce the energy consumption by around 85% compared to the conventional gas boiler, regardless of the distance between power plant and greenhouse.

정상유동에서 자가팽창성 그래프트 스텐트의 수력학적 특성 (Hydrodynamic Characteristics of Self-expandable Graft Stents in Steady Flow)

  • 이홍철;김철생;박복춘;박복춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2003
  • 본 실험연구에서는 정상유동상태에서 새롭게 설계된 자가팽창성 그래프트 스텐트의 수력학적 성능을 평가하고자 하였다. 코팅 재질이 다른 두 개의 그래프트 스텐트와 한 개의 타이티놀 금속스텐트가 실험에 사용되었으며, 유량이 가자 5, 10, 15 1/min에서 스텐트 전후에서의 압력변화 및 속도분포를 측정하였다. 스텐트 삽입에 의한 압력손실은 유량이 증가함에 지수적으로 증가하였다. 특히 15 1/min의 유량에서 다공성 PTFE 그래프트 스텐트와 TiNi 금속스텐트의 압력손실은 거의 동일하나 PU 그래프트 스텐트는 약 6배 이상의 현저한 증가를 보이고 있다. 스텐트 후류에서의 속도분포는 다공성 PTFE 그래프트 스텐트와 TiNi 금속스텐트는 유량에 관계없이 유사한 형태를 보여주고 있다. 그러나, PU 그래프트 스텐트에서는 특히 유량이 10 1/min 이상에서 속도분포가 비대칭적이고 관 중심에서의 상대적인 낮은 유속을 보여주고 있으며, 결과적으로 벽면전단응력 및 수직응력의 증가론 초래하고 있다. 이와같이 PU 그래프트 스텐트의 상대적으로 낮은 수력학적 성능은 스텐트가 보다 작은 관에 삽입되었을때 코팅재질의 낮은 유연성으로 인하여 스텐트의 표면에 주름이 발생하여 유동단면이 비대칭적으로 되고 벽면의 조도가 증가하며, 관벽과 스텐트와 틈새가 존재하여 제트류가 형성되기 때문으로 해석된다.