DOI QR코드

DOI QR Code

Noise Reduction of a Blower for an Automatic Car Washer by Using Dissipative Silencers

흡음형 소음기를 사용한 세차기용 원심송풍기의 소음저감에 관한 연구

  • 김재영 (전북대학교 기계공학과, 한국지엠) ;
  • 이일재 (전북대학교 기계공학과)
  • Received : 2011.05.24
  • Accepted : 2011.07.19
  • Published : 2011.08.20

Abstract

Straight absorptive silencers have been designed to reduce the noise level of a centrifugal blower. Three-dimensional boundary element method is used for the design of absorptive silencers which consist of a perforated main pipe and a outer chamber filled with fibrous material. The experimental results show that the absorptive silencer reduces up to 8 dB(A) in the overall sound pressure level of the blower and up to 15 dB at the blade passing frequency. It is also found that the gap between the silencer and the impeller may substantially alter the acoustic performance of the silencers. The transmission loss predicted by the boundary element method follows overall trends of the measured insertion loss. The experiments also show that the impact of the silencers on the aerodynamic performance of the blower is minimum.

Keywords

References

  1. Cory, W. T. W., 2005, Fans & Ventilation: A Practical Guide, Elsevier in Association with Roles & Associates Ltd.
  2. Ver, I. L. and Beranek, L. L., 2006, Noise and Vibration Control Engineering Principles and Applications, John Wiley and Sons, Inc.
  3. Neise, W., 1976, Noise Reduction in Centrifugal Fans : A Literature Survey, Journal of Sound and Vibration, Vol. 45, No. 3, pp. 375-403. https://doi.org/10.1016/0022-460X(76)90394-1
  4. Embleton, T. F. W., 1963, Experimental Study of Noise Reduction in Centrifugal Blowers, The Journal of the Acoustical Society of America, Vol. 35, No. 5, pp. 700-705. https://doi.org/10.1121/1.1918591
  5. Suzuki, S. and Ugai, Y., 1977, Study on High Specific Speed Airfoil Fans, The Japan Society of Mechanical Engineers, Vol. 20, No. 143, pp. 575-583. https://doi.org/10.1299/jsme1958.20.575
  6. Kim, Y. C. and Lee, S. H., 1997, Experimental Study for Reduction of Blade Passing Frequency Noise Level of Multi-blade Fan, The Society of Air-Conditioning and Refrigerating Engineers of Korea, pp. 574-579.
  7. Fiagbedzi, Y. A., 1952, Reduction of Blade Passage Tone by Angle Modulation, Journal of Sound and Vibration, Vol. 82, No. 1, pp. 119-129.
  8. Kim, H. J., Jung, K. H., Lee, C. J. and Lee, S., 2000, Experimental Study of Trailing Edge Shape of Forward Curved Blade upon Radiated Noise, Korean Fluid Machinery Association, pp. 137-142.
  9. Koopmann, G. H., Fox, D. J. and Neise, W., 1988, Active Source Cancellation of the Blade Tone Fundamental and Harmonics in Centrifugal Fan, Journal of Sound and Vibration, Vol. 126, No. 2, pp. 209-220. https://doi.org/10.1016/0022-460X(88)90236-2
  10. Neise, W. and Koopmann, G. H., 1980, Reduction of Centrifugal Fan Noise by Use of Resonators, Journal of Sound and Vibration, Vol. 73, No. 2, pp. 297-308. https://doi.org/10.1016/0022-460X(80)90697-5
  11. Yoon, J. W., Jeong, G. C. and Kwon, Y. P., 1995, Fan Noise Reduction by a Helmholtz Resonator, The Society of Air-Conditioning and Refrigerating Engineers of Korea, pp. 233-237.
  12. Lee, J. K., Kim, W. B. and Lee, H. K., 2003, Vibration and Noise Reduction of the High Speed Centrifugal Chiller, Inter-noise 2003, pp. 1406-1413.
  13. Lunan, J., 1974, The Use of a Scale Model in the Design of a Silencer for the Pure Tone of a Fan, Applied Acoustics, Vol. 7, No. 2, pp. 147-157. https://doi.org/10.1016/0003-682X(74)90030-9
  14. Kim, Y. W. and Kim, B. S., 2005, An Experimental Study on the Performance Improvement of Industrial Blower Silencer, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 15, No. 9, pp. 1060-1069. https://doi.org/10.5050/KSNVN.2005.15.9.1060
  15. Delany, M. E. and Bazley, E. N., 1970, Acoustical Properties of Fibrous Absorbent Materials, Applied Acoustics, Vol. 3, pp. 105-116. https://doi.org/10.1016/0003-682X(70)90031-9
  16. Lee, I. J., Selamet, A. and Huff, N. T., 2006, Acoustic Impedance of Perforations in Contact with Fibrous Material, The Journal of the Acoustical Society of America, Vol. 119, pp. 2785-2797. https://doi.org/10.1121/1.2188354
  17. Sullivan, J. W. and Crocker, M. J., 1978, Analysis of Concentric-tube Resonators Having Unpartitioned Cavities, The Journal of the Acoustical Society of America, Vol. 64, pp. 207-215. https://doi.org/10.1121/1.381963
  18. Kim, J.-B., Choi, W.-S., Koo, H.-M. and Lee, J.-K., 2004, Noise Reduction of Turbo Fans for Air-conditioner Indoor Units, Proceedings of the KSNVE Annual Spring Conference, pp. 93-96.