• Title/Summary/Keyword: loss modulus (E")

Search Result 54, Processing Time 0.029 seconds

Activated Physical Properties at Air-Polymer Interface

  • Kajiyama, Tisato
    • Macromolecular Research
    • /
    • v.15 no.2
    • /
    • pp.109-113
    • /
    • 2007
  • The surface molecular motion of monodisperse polystyrene (PS) films was examined using scanning vis-coelasticity microscopy (SVM) in conjunction with lateral force microscopy (LFM). The dynamic storage modulus, E', and loss tangent, $tan\delta$, at a PS film surface with number-average molecular weights, $M_n$, smaller than 30 k were found to be smaller and larger than those for the bulk sample, even at room temperature, meaning that the PS surface is in a glass-rubber transition or fully rubbery sate at this temperature when the $M_n$ is small. In order to quantitatively elucidate the dynamics of the molecular motion at the PS surface, SVM and LFM measurements were performed at various temperatures. The glass transition temperature, $T_g$, at the surface was found to be markedly lower than the bulk $T_g$, and this discrepancy between the surface and bulk became larger with decreasing $M_n$. Such an intensive activation of the thermal molecular motion at the PS surfaces can be explained in terms of an excess free volume in the vicinity of the film surface induced by the preferential segregation of the chain end groups.

Creep Strain of Containment Concrete Structure (원자로 격납건물 콘크리트의 크리이프 변형 특성)

  • 방기성;정원섭;조명석;송영철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.95-100
    • /
    • 1996
  • Creep, drying shrinkage, modulus of elasiticity and Poisson's ratio of concrete are influenced by a number of factors such as mix type, member thickness, curing condition and loading cases. Particularly, creep and shrinkage in concrete have yet to be studied due to its complicated time-dependent properties. In this study, the concrete creep tests were carried out at varous ages of loading-7, 28, 90, 180 and 365 days in order to investigate and quantify its long-term properties. The test procedures and analysis of the test results were also described herein. The results of this study will enable A/E to calculate effective prestressing forces considering time-dependent prestressing loss and evaluate the structural integrity of the prestressing system using the representative values derived from this property test.

  • PDF

Fine Structural Change of PET Film Treated with Hydrazine Hydrate in Methanol (Hydrazine/Methanol 처리에 의한 PET Film의 미세구조의 변화)

  • Sung, Woo-Kyung;Cho, Hyun-Hok;Kim, Kyung-Hwan
    • Textile Coloration and Finishing
    • /
    • v.2 no.2
    • /
    • pp.1-6
    • /
    • 1990
  • In order to investigate the fine structural changes of poly (ethylene terephthalate) film by hydrazinolysis, PET was treated with hydrazine hydrate in methanol at $30^{\circ}C$ for various times. Initially apparent crystallite size and degree of orientation are increased and then, gradually decreased with hydrazinolysis. According to thermoluminescence measurement, trap site decreased by dissolution and then gradually increased with growth of defect in structure. Maximum peak temperature of tan and dynamic loss modulus E" upon hydrazinolysis shifted to the lower temperature in the progress of hydrazinolysis.ysis.

  • PDF

Rheological Properties of Gastrodiae Rhizoma Concentrates by Extraction Solvents (추출용매에 따른 천마 농축액의 리올로지 특성)

  • Lee, Boo-Yong;Lee, Ok-Hwan;Kim, Kyung-Im
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.188-194
    • /
    • 2003
  • 천마식품가공시 기초자료로 활용될 수 있는 천마 추출농축액의 리올로지 특성을 조사하였다. 천마의 열수 및 50% 에탄올 추출물운 각각 5, 10, 15, 및 20 Brix와 10, 20, 30, 40 및 50 Brix로 농축하여 제조하였다. 열수 및 50% 에탄올 농축액의 정상유동특성과 동적점탄성을 조사하였다. Power law model로 구한 n에 의하면 모든 열수 농축액들은 전형적인 의가소성$(n=0.484{\sim}0.802)$유체의 흐름특성을 보였고, 50% 에탄올 농축액들은 뉴튼유체$(n=0.875{\sim}1.078)$에 가까운 흐름특성을 나타내었다. 열수 및 50% 에탄올 농축액의 ${\eta}_{app}$는 온도가 증가함에 따라 감소하는 경향을 나타내었다. Herschel-Bulkley model에 의한 열수 및 50% 에탄올 농축액의 C는 각각 $0.030{\sim}1.255$ Pa와 $0.007{\sim}0.065$ Pa이었다. ${\eta}_{app}$에 대한 온도 및 농도의 영향은 arrhenius식으로 해석하였다. 열수 및 50% 에탄올 농축액의 $E_a$는 농도가 증가함에 따라 각각 $3.340{\sim}4.620{\times}10^3\;J/mol{\cdot}kg$$1.6289{\sim}18.6699{\times}10^3\;J/mol{\cdot}kg$의 범위로 나타났다. 진동수(angular frequency, ${\omega}$)가 증가할수록 저장탄성률(storage modulus, G#)과 손실탄성률(loss modulus, G@)은 일반적으로 증가하는 경향을 나타냈다. 50% 에탄올 농축액의 경우 모든 진동수에서 G#이 G@보다 높게 나타나 전형적인 저분자용액의 흐름특성을 보였다. 그러나 열수농축액의 경우 G@이 G#보다 높았고 0.5 rad/sec에서 교차점을 형성하였으며 전형적인 고분자 용액의 흐름특성을 나타내었다.

Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels

  • Lim, Jaekwan;Won, Jong Yun;Ahn, Chi Bum;Kim, Jieon;Kim, Hee Jung;Jung, Jae Seung
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.81-87
    • /
    • 2021
  • Background: Artificial grafts such as polyethylene terephthalate (Dacron) and expanded polytetrafluoroethylene (ePTFE) are used for various cardiovascular surgical procedures. The compliance properties of prosthetic grafts could affect hemodynamic energy, which can be measured using the energy-equivalent pressure (EEP) and surplus hemodynamic energy (SHE). We investigated changes in the hemodynamic energy of prosthetic grafts. Methods: In a simulation test, the changes in EEP for these grafts were estimated using COMSOL MULTIPHYSICS. The Young modulus, Poisson ratio, and density were used to analyze the grafts' material properties, and pre- and post-graft EEP values were obtained by computing the product of the pressure and velocity. In an in vivo study, Dacron and ePTFE grafts were anastomosed in an end-to-side fashion on the descending thoracic aorta of swine. The pulsatile pump flow was fixed at 2 L/min. Real-time flow and pressure were measured at the distal part of each graft, while clamping the other graft and the descending thoracic aorta. EEP and SHE were calculated and compared. Results: In the simulation test, the mean arterial pressure decreased by 39% for all simulations. EEP decreased by 42% for both grafts, and by around 55% for the native blood vessels after grafting. The in vivo test showed no significant difference between both grafts in terms of EEP and SHE. Conclusion: The post-graft hemodynamic energy was not different between the Dacron and ePTFE grafts. Artificial grafts are less compliant than native blood vessels; however, they can deliver pulsatile blood flow and hemodynamic energy without any significant energy loss.

Time-dependent properties of lightweight concrete using sedimentary lightweight aggregate and its application in prestressed concrete beams

  • Chen, How-Ji;Tsai, Wen-Po;Tang, Chao-Wei;Liu, Te-Hung
    • Structural Engineering and Mechanics
    • /
    • v.39 no.6
    • /
    • pp.833-847
    • /
    • 2011
  • We have developed a lightweight aggregate (LWA) concrete made by expanding fine sediments dredged from the Shihmen Reservoir (Taiwan) with high heat. In this study, the performance of the concrete and of prestressed concrete beams made of the sedimentary LWA were tested and compared with those made of normal-weight concrete (NC). The test results show that the lightweight concrete (LWAC) exhibited comparable time-dependent properties (i.e., compressive strength, elastic modulus, drying shrinkage, and creep) as compared with the NC samples. In addition, the LWAC beams exhibited a smaller percentage of prestress loss compared with the NC beams. Moreover, on average, the LWAC beams could resist loading up to 96% of that of the NC beams, and the experimental strengths were greater than the nominal strengths calculated by the ACI Code method. This investigation thus established that sedimentary LWA can be recommended for structural concrete applications.

Thermo-dynamic Characteristics Of High Temperature Nitinol Shape Memory Alloy (고온용 Nitinol 형상기억합금의 열적/동역학적 특성평가)

  • Cha S.Y.;Park S.E.;Cho C.R.;Park J.K.;Jeong S.Y.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.441-445
    • /
    • 2005
  • In the resent years, as the research and the development of micro and precision machinery become active, the interest of micro actuators using SMA(Shape Memory Alloy) has been increased. But, no detailed researches between the thermo-dynamic property in Nitinol alloy have been done yet. In this study, the thermal property of high temperature Nitinol shape memory alloy were evaluated using differential scanning calorimeter(DSC). The structure property was investigated using X-ray diffraction(XRD). A dynamic mechanical analyzer(DMA) with three point bending mode was used to study storage and loss modulus of shape memory alloy according to the thirteen frequencies in the temperature range between 30 and $200^{\circ}C$. The effects of the temperature heating/cooling rate, the frequency on the damping capacity have been systematically investigated. Such a frequency and temperature changes also influenced significantly to the damping behavior of the shape memory alloy. It was also found that Nitinol exhibited high damping capacity during phase transformation.

  • PDF

Fabrication and Performance Evaluation of Carbon Fiber/Graphene Nano-Platelets Composites for Wear Resistance Application (GNP 첨가 탄소복합재료의 제조 및 마모 특성 평가)

  • Park, Seung-Bhin;Park, Jin-Chul;Cho, Chang-Woo;Song, Jung-Il
    • Korean Journal of Materials Research
    • /
    • v.25 no.10
    • /
    • pp.531-536
    • /
    • 2015
  • GNPs have several excellent mechanical properties including high strength, a good young's modulus, thermal conductivity, corrosion resistance, electronic shielding, etc. In this study, CF/GNP/Epoxy composites were manufactured using GNP weight ratios of 0.15 wt%, 0.3 wt%, 0.5 wt%, 0.7 wt% and 1 wt%. The composites were manufactured with a mechanical method (3-roll-mill). Tensile, impact and wear tests were performed according to ASTM standards D3039, D256 and D3181, respectively. The results show that the CF/GNP0.3wt%/Epoxy composites have good mechanical properties, e.g., tensile strength and impact and wear resistance. In this study, both carbon fabric and GNPs were used as reinforcements in the composites. The mechanical properties increased and weight loss decreased as the GNP content in the resin films was increased.

High Power Characteristics of $Pb(Y_{2/3}W_{1/3})O_3-Pb(Zr,Ti)O_3$Ceramics ($Pb(Y_{2/3}W_{1/3})O_3-Pb(Zr,Ti)O_3$계 세라믹스의 고출력 특성)

  • ;Kenji Uchino
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.5
    • /
    • pp.394-399
    • /
    • 1998
  • High power characteristics with vibration velocity were studied in $Pb(Y_{2/3}W_{1/3})O_3-Pb(Zr,Ti)O_3$(PYW-PZT) ceramics by using the constant current method. Young s modulus $Y_0^E$ and mechanical quality factor $Q_m$ are a function of the square of effective vibration velocity \upsilon_0$. The nonlinear proportional constants of the above functions indicate the degree of stability under the vibration level change. The stability of PYW-PZT ceramics estimated by these constants coincides with the results obtained through the heat generation. It was found that $Q_m$ was markedly decreased with increasing the vibration velocity, accompanying a lot of heat generation. The vibration hysteresis and dielectric loss according to the vibration velocity was reduced by doping $Fe_2O_3$to the ceramics. On the contrary, these losses was increased by doping $Nb_2O_5$.

  • PDF

Preparation and Characteristics of the Blends of Polyimide and Polybenzoxazole Having Imide Ring (주사슬에 이미드고리를 갖는 Polybenzoxazole과 Polyimide의 블렌드 제조 및 특성)

  • Wee, Doo-Young;Han, Jin-Woo;Choi, Jae-Kon
    • Polymer(Korea)
    • /
    • v.37 no.4
    • /
    • pp.420-430
    • /
    • 2013
  • Polymer blends were prepared by solution blending poly(amic acid) (PAA) and poly(o-hydroxy amide) (PHA) having imide groups in the main chain. The polymers and their blends were characterized by using FTIR, FT NMR, DSC, TGA, SEM, XRD, UTM, and LOI. The solubility study revealed that the blends were readily soluble in aprotic solvents such as DMF, DMAc, DMSO, and NMP. The maximum weight loss of the blends occurred in the range of $578-645^{\circ}C$, and the maximum weight loss temperature increased with increasing the PHA content. The PBO/PI blends showed relatively high char yields (i.e. 56-69 wt%). The LOI values of the blends were in the range of 24.5-28.1% and increased with increasing the PHA content. The initial modulus and tensile strength of the blends increased by 57 to 121% and by 67 to 107%, respectively, compared to the values of PAA. Especially the initial modulus and tensile strength of the PHA/PAA=2/8(wt/wt) showed the highest values of 4.87 GPa and 108 MPa, respectively. The PHA domains of $0.03-0.1{\mu}m$ in their size were more or less uniformly dispersed. The interfacial adhesion between PAA and PHA was found to be good.