• Title/Summary/Keyword: long period structure

Search Result 474, Processing Time 0.024 seconds

Equivalent Damping Ratio Based on Earthquake Characteristics of a SDOF Structure with an MR Damper (지진특성에 따른 MR감쇠기가 설치된 단자유도 구조물의 등가감쇠비)

  • Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.1
    • /
    • pp.87-93
    • /
    • 2008
  • Seismic control performance of MR dampers, which have severe nonlinearity, varies with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with the MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with the MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. Frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed. Finally. response reduction factors for equivalent linear systems are proposed in order to improve accuracy in the prediction of the actual nonlinear response.

The Impact of the RMB Exchange Rate Expectations on Foreign Direct Investment in China

  • Yuantao FANG;Renhong WU;Md. Alamgir HOSSAIN
    • The Journal of Economics, Marketing and Management
    • /
    • v.12 no.3
    • /
    • pp.1-12
    • /
    • 2024
  • Purpose: As a major economy attracting foreign investment, China is currently facing significant international economic pressure due to the appreciation of the RMB. Additionally, China is at a critical period of socio-economic development, where foreign direct investment (FDI) plays an indispensable role in stabilizing economic growth, adjusting industrial structure, and promoting economic transformation. Research design, data and methodology: This paper focuses on the relationship between RMB exchange rate expectations and FDI. It examines the magnitude of their relationship through empirical research using cointegration tests, Granger causality tests, and BVAR (Bayesian Vector Autoregression) analysis. Results: The comprehensive study of the empirical results in this paper concludes that there is a long-term cointegrated relationship between China's RMB exchange rate expectations and foreign direct investment, indicating that their relationship is stable in the long run. It is also found that RMB exchange rate expectations have a significantly positive impact in the short term, but this impact is not significant in the long term. Conclusions: The paper also considers the possibility of establishing a China-EU Free Trade Area in the future and offers policy recommendations regarding RMB exchange rate expectations and foreign direct investment.

Molecular Distribution depending on the Cooling-off Condition in a Solution-Processed 6,13-Bis(triisopropylsilylethynyl)-Pentacene Thin-Film Transistor

  • Park, Jae-Hoon;Bae, Jin-Hyuk
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.402-407
    • /
    • 2014
  • Herein, we describe the effect of the cooling-off condition of a solution-processed 6,13-bis(triisopropylsilylethynyl)-pentacene (TIPS-pentacene) film on its molecular distribution and the resultant electrical properties. Since the solvent in a TIPS-pentacene droplet gradually evaporates from the rim to the center exhibiting a radial form of solute, for a quenched case, domains of the TIPS-pentacene film are aboriginally spread showing original features of radial shape due to suppressed molecular rearrangement during the momentary cooling period. For the slowly cooled case, however, TIPS-pentacene molecules are randomly rearranged during the long cooling period. As a result, in the lopsided electrodes structure proposed in this work, the charge transport generates more effectively under the case for radial distribution induced by the quenching technique. It was found that the molecular redistribution during the cooling-period plays an important role on the magnitude of the mobility in a solution-processed organic transistor. This work provides at least a scientific basis between the molecular distribution and electrical properties in solution-processed organic devices.

Decadal Changes in the Relationship between Arctic Oscillation and Surface Air Temperature over Korea (북극진동과 한반도 지표기온 관계의 장기변동성)

  • Jun, Ye-Jun;Song, Kanghyun;Son, Seok-Woo
    • Atmosphere
    • /
    • v.31 no.1
    • /
    • pp.61-71
    • /
    • 2021
  • The relationship between the Arctic Oscillation (AO) and surface air temperature (SAT) over Korea is re-examined using the long-term observation and reanalysis datasets for the period of December 1958 to February 2020. Over the entire period, Korean SAT is positively correlated with the AO index with a statistically significant correlation coefficient, greater than 0.4, only in the boreal winter. It is found that this correlation is not static but changes on the decadal time scale. While the 15-year moving correlations are as high as 0.6 in 1980s and 1990s, they are smaller than 0.3 in the other decades. It is revealed that this decadal variation is partly due to the AO structure change over the North Pacific. In the period of 1980s-1990s, the AO-related sea level pressure fluctuation is strong and well defined over the western North Pacific and the related temperature advection effectively changes the winter SAT over Korea. In the other periods, the AO-related circulation anomaly is either weak or mostly confined within the central North Pacific. This result suggests that Korean SAT-AO index relationship, which becomes insignificant in recent decades is highly dependent on mean flow change in the North Pacific.

A Study on Gyeolseong-Eupseong of the Joseon Dynasty Period (조선시대 결성읍성(結城邑城) 연구)

  • Kim, Hoe-Jung;Lee, Jeong-Soo
    • Journal of architectural history
    • /
    • v.19 no.6
    • /
    • pp.7-22
    • /
    • 2010
  • This study includes a review of the relevant literature and data on the Gyeolseong Eupseong, a coastal castle town of the Joseon Period. During the process of building the Gyeolseong Eupseong, Eupchi(administrative office) was transferred to several different locations for the following reasons:. first, to strengthen defensive capabilities by utilizing the locational advantages of the Seokdang Mountain Fortress, second, to secure sufficient space for holding the castle and have access to water in times of emergencies, third, to strengthen coastal defence by utilizing geographical advantages. Most of the Gyeolseong Eupseong was damaged during the Japanese colonial period. At present, there remain only part of the castle's facilities and some facilities that were restored later in modern times; 4 building sites have been identified. Remaining and destructed buildings can be identified through old maps(the local maps of 1872) and Zirizi and Eupzi(geography books). Also identified were 2 castle gate sites where a 1,500m-long stone castle wall and an ongseong(a crescent-shaped defensive structure), 5 chiseongs, and a most were constructed. The Gyeolseong area is assumed to have been a strategic foothold to defend the west coast from the days before the Three Kingdom Period. However it is very difficult to find any records created before the Joseon Period. Therefore, the time of the restoration of the Eupchi should be determined based on records created in the late Joseon Period. Finally, excavation work needs to be done to identify the locations of the castle's facilities.

Application of Equivalent Beam Element for Practical Vibration Analysis of Stadium Structure (스타디움 구조물의 실용적인 진동해석을 위한 등가보요소의 적용)

  • Kim, Gee-Cheol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.91-99
    • /
    • 2004
  • In general, stadium structure with long span has low inherent natural frequency. In the stadium structure, structural behavior similar to resonance can be occurred easily by spectator rhythmical movements of which exciting period is small comparatively. It is required to investigate the safety and the serviceability of stadium structure. Therefore, there exists a necessity for accurate vibration analysis. Accurate analysis of stadium structure subjected to dynamic load is required for economical construction and safe design of stadium structure. Stadium structure should be modeled by refined mesh for accurate vibration analysis. As the mesh of stadium structure is refined, the number of divided elements increases in numerical analysis. The number of node is increased and numerous computer memories or computational time are required. So it is very difficult to analyze refine model of stadium structures by using the commercial programs. It is possible to efficient vibration analysis of stadium structure by finite element modeling method using equivalent beam element proposed in this paper, because the number of nodes is decreased remarkably.

Design Shear Force Reduction Factor of Upper Structure in Seismic Base-isolated System Considering Response Acceleration Decrement Effect (면진구조의 응답가속도 감소효과를 고려한 상부구조의 설계전단력 저감계수)

  • Chen, Hao;Oh, Sang-Hoon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.165-170
    • /
    • 2019
  • The structural damage caused by earthquake to the upper structure of seismic base-isolated system can be suppressed effectively because it is designed to concentrate the input energy on the seismic isolation floor. Further, the response acceleration of seismic base-isolated system can be greatly reduced compared to the seismic structure because of the long period, which means that the design shear force of the seismic base-isolated system can be reduced appropriately. However, when the design shear force is determined to be reduced, the design stiffness will decrease, and the response acceleration will increase oppositely. Therefore, for finding the extent to which the design shear force of the upper structure can be reduced, this paper considered the seismic base-isolated structure as the analytical model and proposed the design shear force reduction factor of the base-isolated structure through the dynamic response analysis, while considering the decrement effect of response acceleration. The research result shows that the response acceleration of the isolated the upper structure can be reduced by 50%~70% of the seismic structure under the same design conditions, and the design shear force can be reduced by up to 40%. By increasing the design stiffness over to 1.8 times of the original design value, the design shear force can be reduced to the same extent as the response acceleration can be reduced compared to the seismic structure.

Effect of the factor developing the Heat of Hydration on Durability Design in the Subway Concrete Structure (수화열 발생인자가 지하철 콘크리트 구조물의 내구설계에 미치는 영향)

  • Lim Young-Su;Kim Eun Kyum;Sung Ki Han
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1131-1137
    • /
    • 2004
  • With the recent continuous expansion of subways, newly created subways tend to have lower locations and wider sections. Furthermore. since box structures and evacuating tunnels are classified into a category of mass-concrete. the thermal-stress, emitted from the inside. causes cracks to structures from the inception of constructing. In this paper, thermal-stress analysis and durability evaluation of box structure were carried out to investigate relationship between durability and parameter causing the heat of hydration. Through the examination, this paper tries to find out satisfactory solutions to regulated thermal crack and ensure the required duration period. The results of this paper showed that to control thermal crack and guarantee the required duration period it was more effective to use low-heat-portland cement and moderateheat-portland cement. As cement volume due to reduction of water-cement ratio increased, the possibility of thermal cracks occurrence increased but results of durability evaluation was different depending on evaluation method. The results showed that the appropriate water-cement ratio to control the heat of hydration and satisfy the required durability was $45\∼55\%$. And it was showed that during placement of concrete blocks ambient temperature affect the heat of hydration. thermal crack and long-term durability largely and when concrete was placed at low temperature to control thermal crack. it need to try to guarantee the required duration period. Henceforth, by studying not only internal and external conditions, such as the relative humidity and the unit weight. but also methods, to evaluate durability, in accordance with domestic situations, more reasonable design of durability should be achieved.

  • PDF

Dynamic Behavior Evaluation of Pile-Supported Slab Track System by Centrifuge Model Test (원심모형 실험을 통한 궤도지지말뚝구조의 동적 거동 평가)

  • Yoo, Mintaek;Lee, Myungjae;Baek, Mincheol;Choo, Yun-Wook;Lee, Il-Wha
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.2
    • /
    • pp.5-17
    • /
    • 2019
  • Dynamic centrifuge model test was conducted to evaluate the dynamic stability of the pile-supported slab track method during dynamic railway loading and earthquake loading. The centrifuge tests were carried out for various condition of embankment height and soft ground depth. Based on test results, we found that the bending moment was increased with embankment height and decreased with soft ground depth. In addition, it was confirmed that the pile-supported slab track system could have dynamic stability for short-period seismic loading. However, in case of long-period seismic loading, such as Hachinohe earthquake, the observed maximum bending moment reached to pile cracking moment at the return period of 2,400 year earthquake. The criterion of ratio between embankment height and soft ground depth was suggested for dynamic stability of pile-supported slab track system.

Evaluation of Loss of Prestress Force of Tensile Anchor by Long Term Measurement (장기계측을 통한 인장형 앵커의 인장력 손실 평가)

  • Lee, Bongjik;Lee, Jongkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.10
    • /
    • pp.15-22
    • /
    • 2015
  • In this study, to evaluate the long-term behavior characteristics and the loss of prestress force, the long-term measurement of the tensile anchors in the actual construction was performed and the results were analyzed comparing with the existing estimation. As the reinforcement member used for the purpose of slope stability or uplift-resisting of the permanent structure, etc, the permanent anchor should maintain the functions during the performance period of the structure differently from the temporary anchor. However, as the time passes by, since the relaxation and the creep of the anchor occur constantly, the management for the loss of tensile force is essential to perform the functions stably. So far, the loss of the tensile force has been estimated according to the reduction of the prestress using elasticity theory and using the relaxation value according to the type of tension member and the test using the long-term measurement is limited. Therefore, in this study, the site condition and the ground were investigated for the tensile anchor in the actual construction and the long-term measurement results more than 500 days was analyzed by installing the loadcell, inclinometer and the groundwater level gauge. In addition, the long-term behavior characteristics were evaluated by comparing the disposition of the measured earth retaining wall and the tension force loss of the anchor with the existing interpretation results. In the evaluation results, the most of the tension force loss occurs within 90 days and the loss was measured less than the estimated values.