• Title/Summary/Keyword: locking plate

Search Result 163, Processing Time 0.027 seconds

Comparison Study of Different Approach (Deltoid Splitting Approach and Delto-pectoral Interval Approach) for Proximal Humeral Fractures (근위 상완골 골절의 수술적 치료에서 삼각근 분할 도달법과 삼각 대흉간 도달법의 임상적, 방사선학적 추시 결과 비교)

  • Kim, Seung-Hee;Dan, Jinmyoung;Kim, Byoung-Kook;Lee, Yun-Seok;Kim, Hyoeng-Jung;Ryu, Keun-Jeong;Lee, Jin-Hyun;Kim, Jae-Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2013
  • Purpose: A comparison of the radiographic and the clinical outcomes between two different surgical approaches-Deltoid splitting and Delto-pectoral interval-on the proximal humerus fractures treated by locking compressive plate (LCP), is done. Materials and Methods: Medical records and pre- and postoperative radiographs were reviewed retrospectively for 75 adult patients who underwent surgical fixations with locking compressive plates from May 2005 to December 2011. Patients were divided into two groups according to the surgical methods. Differences in the neck-shaft angle between immediate postoperative period and final follow-up were compared between the two groups. Differences in constant score and Korean shoulder score (KSS) between affected arms and contralateral arms at final follow-up were also compared. Results: The differences in the neck-shaft angle between immediate postoperative period and at final follow-up was 12.04 degrees on average in Deltoid splitting approach and 10.20 degrees in Delto-pectoral interval approach, which was not statistically significant. Differences in constant score/KSS between the affected arm and the contralateral arm were 13.78/22.74 points in deltoid-splitting approach on average and 19.41/31.13 points in Delto-pectoral interval approach, showing that deltoid-splitting approach is significantly superior. Conclusion: Deltoid-splitting approach showed better functional outcomes in the fracture reduction and internal fixation using LCP for the treatment of unstable proximal humerus fractures.

The Volar Plating of Fracture of the Coronoid Process - Report of Two Cases - (구상돌기 골절에서 내측 접근법을 통한 전방 금속판 고정술 - 2예 보고 -)

  • Jung, Gu-Hee;Cho, Chul-Hyun;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.260-265
    • /
    • 2010
  • Purpose: To report the clinical results of two cases of coronoid process fractures that were treated with volar plating through a medial approach. Materials and Methods: Two fractures of the coronoid process that needed to be fixed were managed with open reduction and internal fixation through a medial approach using 2.4 mm locking compression plates (Compact Hand set$^{(R)}$, Synthes, Switzerland). The patients were followed up for 14 months and 17 months and were evaluated using the Mayo Elbow Performance Score (MEPS). Results: The MEPS was 95 for Case 1 and 100 for Case 2. Active elbow joint motions were $5^{\circ}-120^{\circ}$ (Case 1) and $0^{\circ}-130^{\circ}$ (Case 2). Supination and pronation fully recovered. Conclusion: Satisfactory results can be obtained in cases of coronoid process fractures because volar plating through a medial approach allows sound fixation and early mobilization of the elbow joint.

Conversion to Internal Fixation after Temporary External Fixation for Femoral Shaft Fractures in Polytrauma Patients (다발성 외상 환자의 대퇴골 간부 골절에서 임시 외고정술 후 내고정술로의 전환)

  • Choo, Suk-Kyu;Kang, Kyung-Woon;Kim, Young-Woo;Oh, Hyoung-Keun
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.151-157
    • /
    • 2014
  • Purpose: We report the surgical outcomes for femoral shaft fractures in polytrauma patients who were temporarily treated with external fixation and subsequently converted to internal fixation. Methods: From August 2008 to April 2012, we enrolled 13 patients with multiple traumas due to high-energy injuries and concurrent femoral shaft fractures in which temporary external fixation was carried out. The mean age was 39 years, with a range from 18 to 55 years. Ten were men and 3 were women. According to the AO/OTA classification of fractures, type A was found in 5 patients, type B in 6, and type C in 2, with open fractures being found in 6 patients and femoral artery rupture occurring in 2. For internal fixation, intramedullary nailing was performed in 7 patients, and minimally-invasive fixation of locking compression plates was used in 6. Results: Of the 7 patients converted to intramedullary nailing, 1 experienced delayed union. Of the 6 patients treated with minimally-invasive plate fixation, delayed union occurred in 5, and an auto-bone graft was performed within, on average, 8 months (range: 5~10 months), leading to bone union in all cases in the final follow-up. None of the patients experienced infections or complications involving other organs after having been converted to internal fixation. During the mean follow-up of 19 months, patients achieved satisfactory functional outcomes. Conclusion: In polytrauma patients with a femoral shaft fracture who have been treated with temporary external fixation and who may need internal fixation due to the occurrence of delayed union, an appropriate internal fixation method needs to be selected based on the patient's physical status, and the fracture type.

Clinical and Radiological Outcome after Surgical Treatment in Displaced Clavicular Midshaft Fracture

  • Gwak, Heui-Chul;Kim, Jung-Han
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.2
    • /
    • pp.73-77
    • /
    • 2016
  • Background: The first purpose of this study is to compare the clinical and radiological outcomes of surgical treatment for displaced midshaft clavicle fracture (Robinson type 2B1 vs. 2B2) with 3.5-mm low profile clavicular locking compression plate. The second purpose is to evaluate the difference of the results depending on the presence of accompanying injuries. Methods: Forty-nine patients who underwent an operation for the fractures were reviewed retrospectively. Fracture patterns were classified according to group 2B1 and 2B2 using Robinson's classification. For radiological outcome, time to union after operation was evaluated and for clinical outcome, American Shoulder and Elbow Society (ASES) score, University of California in Los Angeles (UCLA) score, visual analogue scale (VAS), and range of motion (ROM) were evaluated from preoperative period to last follow-up period. Results: The mean time for union was not significantly different in the 2B1 group and 2B2 group (p=0.062). No statistically significant difference in ASES score, UCLA score, and VAS was observed between 2B1 and 2B2 (p=0.619, p=0.896, p=0.856, respectively). In ROM, significant higher mean forward flexion and abduction was observed in 2B2 (p=0.025, p=0.017, respectively) and there was no difference in external rotation and external rotation at shoulder $90^{\circ}$ abduction position (p=0.130, p=0.180, respectively). There was no significant difference in clinical outcomes according to the accompanying injuries. Conclusions: There was no difference in clinical and radiological outcome between Robinson 2B1 and 2B2 type fracture after the operation. Accompanying injuries may not affect the clinical result of displaced midshaft clavicle fractures.

Ultimate Strength Analysis of Stiffened Shell Structures Considering Effects of Residual Stresses (잔류응력을 고려한 보강된 쉘 구조의 극한강도 해석)

  • 김문영;최명수;장승필
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.2
    • /
    • pp.197-208
    • /
    • 2000
  • Choi et al./sup 1)/ presented the total Lagrangian formulation based upon the degenerated shell element. Geometrically correct formulation is developed by updating the direction of normal vectors and taking into account the second order rotation terms in the incremental displacement field. Assumed strain concept is adopted in order to overcome the shear locking phenomena and to eliminate the spurious zero energy mode. In this paper, for the ultimate strength analysis of stiffened shell structures considering effects of residual stresses, the return mapping algorithm based on the consistent elasto-plastic tangent modulus is applied to anisotropic shell structures. In addition, the load/displacement incremental scheme is adopted for non-linear F.E. analysis. Based on such methodology, the computer program is developed and numerical examples to demonstrate the accuracy and the effectiveness of the proposed shell element are presented and compared with the results in literatures.

  • PDF

Application of Umbilical System for Launch Vehicle (우주 발사체 엄빌리칼 시스템의 현황 및 적용사례)

  • Kim, Dae Rae;Lim, Chankyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.21-25
    • /
    • 2017
  • The umbilical system used for launch vehicle is to connect all ground supply lines (Pneumatic, hydraulic and electrical) to launch vehicle and disconnect those at few second before launch vehicle lift-off (or simultaneously with launch vehicle lift-off). During launch preparation stage, all umbilical shall be securely connected and also at separation stage, separation of all umbilical line shall be guaranteed. Therefore finding an appropriate connection force is a key factor on development of umbilical system. According to these design requirement, various kind of umbilical system has been developed from early stage of space development till today. In this paper, various kind of umbilical system developed so far is introduced according to its feature and operational concept. Also, umbilical system used for KSLV-II is introduced

  • PDF

Strut Support with Tricortical Iliac Allografts in Unstable Proximal Humerus Fractures: Surgical Indication and New Definition of Poor Medial Column Support

  • Lee, Seung-Jin;Hyun, Yoon-Suk;Baek, Seung-Ha
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • Background: The execution of fibular allograft augmentation in unstable proximal humerus fractures (PHFs) was technically demanding. In this study, the authors evaluated the clinical and radiographic outcomes after tricortical iliac allograft (TIA) augmentation in PHFs. Methods: We retrospectively assessed 38 PHF patients treated with locking-plate fixation and TIA augmentation. Insertion of a TIA was indicated when an unstable PHF showed a large cavitary defect and poor medial column support after open reduction, regardless of the presence of medial cortical comminution in preoperative images. Radiographic imaging parameters (humeral head height, HHH; humeral neck-shaft angle, HNSA; head mediolateral offset, HMLO; and status of the union), Constant score, and range of motion were evaluated. Patients were grouped according to whether the medial column support after open reduction was poor or not (groups A and B, respectively); clinical outcomes were compared for all parameters. Results: All fractures healed radiologically (average duration to complete union, 5.8 months). At final evaluation, the average Constant score was 73 points and the mean active forward flexion was $148^{\circ}$. Based on the Paavolainen assessment method, 33 patients had good results and 5 patients showed fair results. The mean loss of reduction was 1.32 mm in HHH and 5.02% in HMLO. None of the parameters evaluated showed a statistically significant difference between the two groups (poor and not poor medial column support). Conclusions: In unstable PHFs, TIA augmentation can provide good clinical and radiological results when there are poor medial column support and a large cavitary defect after open reduction.

Development and feasibility test of sit-to-stand transfer assistive device

  • Ha, SinHo;Jeong, SeYeon;Hong, SoungKyun;Choi, Wonjae;Lee, Kwangkook;Park, Donghwan;Son, SangJun;Shin, HyeonHui;Lee, GyuChang
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.1
    • /
    • pp.41-46
    • /
    • 2022
  • Background: The purpose of this study was to develop a sit-to-stand transfer assistive device, and to conduct a feasibility test. Design: A technical note. Methods and results: In this study, we developed a sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. The sit-to-stand transfer assistive device allows the user to transfer the weight from a sitting position to a standing position while shifting the weight forward by grabbing and pulling a support stand. Ten healthy adults participated in the feasibility test of the device. Each participant used the developed sit-to-stand transfer assistive device and investigated supplementation through a brief interview. As a result of the feasibility test, the opinion was that the device could assist the sit-to-stand transfer to some extent. There were opinions that it needed a function to adjust the height of the knee protective plate in the sitting position according to the user's physical characteristics. Because of the inconvenience of operating the lock device for fixing the position and adjusting inclination, there was an opinion that the improvement for a locking device is needed. There were opinions that it would be better to reduce the size of the device due to its inconvenience of portability. Conclusion: In this study, we developed the sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. In addition, it is considered that the upgrade of the device is necessary for the future since there are supplementary opinions on some points.

A modified method of augmented distal clavicle fracture osteosynthesis with a Fibertape coracoclavicular cerclage

  • Wu, ChengHan;Teo, Timothy Wei Wen;Wee, Andy Teck Huat;Toon, Dong Hao
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.230-235
    • /
    • 2022
  • Background: Unstable distal clavicles experience high non-union rates, prompting surgeons to recommend surgery for more predictable outcomes. There is a lack of consensus on the optimal method of surgical fixation, with an array of techniques described in the literature. We describe an alternative method of fixation involving the use of a distal clavicular anatomical locking plate with Fibertape cerclage augmentation in our series of patients. Methods: Nine patients (8 males and 1 female), with a mean age of 36 years, who sustained unstable fracture of the distal clavicle in our institution were treated with our described technique. Postoperative range of motion, functional and pain scores, and time to radiographic union were measured over a mean follow-up period of 10 months. Incidences of postoperative complications were also recorded. Results: At the last patient consult, the mean visual analog scale score was 0.88±0.35, with a mean Disabilities of the Arm, Shoulder, and Hand (DASH) score of 1.46±0.87 and American Shoulder and Elbow Surgeons (ASES) score of 94.1±3.57. The mean range of motion achieved was forward flexion at 173°±10.6°, abduction at 173°±10.6°, and external rotation at 74.4°±10.5°. All patients achieved internal rotation at a vertebral height of at least L2 with radiographical union at a mean of 10 weeks. No removal of implants was required. Conclusions: Our described technique of augmented fixation of the distal clavicle is effective, produces good clinical outcomes, and has minimal complications.

3.5 mm T-shaped LCP (Locking Compression Plate) Fixation for Unstable Distal Clavicular Fractures (3.5 mm T형 잠김 금속판을 이용한 원위 쇄골 골절의 치료 결과)

  • Lee, Churl-Woo;Kim, Hee-Chun;Roh, Jae-Young;Park, Young-Su
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • Purpose: To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures. Materials and Methods: From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system. Results: The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case. Conclusion: 3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.