• 제목/요약/키워드: lock-in-frequency

검색결과 244건 처리시간 0.023초

치과위생사의 방사선 촬영업무의 확대에 대한 문헌적 고찰 (A literature review on expansion of dental hygienists' radiography operations)

  • 최영숙;김진경;장종화;박용덕
    • 한국치위생학회지
    • /
    • 제9권2호
    • /
    • pp.111-124
    • /
    • 2009
  • This study analyzes through the review of literature and laws the exposure time, clinical frequency, and radiation exposure of intraoral and extraoral radiography as well as of panoramic radiography performed by dental hygienists in dental clinics, compares the dental radiology curriculums of radiological science and dental hygiene departments, and proposes the expansion of dental hygienists' radiography operations. The radiology curriculums were compared between the radiological science and dental hygiene departments of colleges. For new analysis by radiography for dental diagnosis, the exposure time, radiation absorbed dose, effective dose, and number of days of natural radiation were compared by the type of oral radiation films and radiographical techniques proposed by domestic and international studies. The exposure time of panoramic radiography is 15 seconds and it takes about two minutes for completion, whereas the exposure time of the standard radiography is 0.2~0.8 seconds and it takes 10 times longer for completion of the radiography of full mouth than the panoramic radiography. The standard radiography can cause distortions of radiation at severely curved parts of dental arch and palatopharyngeal reflex. However, panoramic radiography can be performed even for lock jaw patients, causes less inconvenience to patients and is much simpler than the standard radiography. The percentage of dental clinics where radiography is performed by dental hygienists was 92.0%, and the percentage of standard film radiography by dental hygienists was 98% whereas the percentage of panoramic radiography by dental hygienists was 92%. For the absorbed dose which is an indicator of radiation exposure, the When the effective dose which is an indicator of the danger of radiation exposure was converted to the number of days of natural radiation, it was 3.3 days for panoramic radiography, but 13.9 days for the full mouth standard radiography by bisecting angle technique which was 4.2 times longer than the panoramic radiography. There were two colleges that had a dental radiology course with two credits in the departments of radiological science. The credits for dental radiology courses in the department of dental hygiene ranged varied by college, ranging from 3 to 8; on average, the theory course was 2.2 credits and the practice course was 2.02 credits. To summarize the above results, the percentage of dental clinics where panoramic radiography is performed by dental hygienists under the guidance of dentists is high. Panoramic radiography has become an essential facility for dental clinics. It is faster than standard film radiography and less dangerous due to low radiation exposure. Panoramic radiography is a simple mechanical job that does not require training of oral radiography by radiotechnologist. Because panoramic radiography is one of major operations which must be performed at all times in dental clinics, it must be designated as intraoral technique rather than extraoral technique, or legalized for inclusion in the scope of operations of dental hygienists.

  • PDF

가역투자율 측정에 의한 터빈로터강의 비파괴적 잔여수명 평가 (Nondestructive Evaluation of Remanent Life of Turbine Rotor Steel by Measuring Reversible Magnetic Permeability)

  • 유권상;남승훈;김용일
    • 비파괴검사학회지
    • /
    • 제23권4호
    • /
    • pp.315-321
    • /
    • 2003
  • 고온, 고압에서 운용되고 있는 설비의 안전성을 평가하기 위해서는 사용시간 동안 열화된 물성을 정기적으로 점검하여 설비의 잔여수명을 평가해야 한다. 본 연구에서는 교류 섭동 자기장을 인가하여 구한 가역투자율 값을 이용하여 1Cr-1Mo-0.25V 강의 잔여수명을 평가하기 위한 자기적 방법을 제시하고자 한다. 이 방법은 자기이력곡선의 미분값인 가역투자율이 보자력에서 첨두 값을 갖는 특성을 이용하였으며, 측정원리는 교류 섭동 자기장의 주파수에 동조된 록-인 증폭기를 사용하여 탐지코일에 유도된 제 1 고조파의 전압을 측정하는 것이다. 가역투자율의 첨두값 간격 (peak interval of reversible magnetic permeability: PIRMP)과 비커스 경도는 열화가 진행됨에 따라 감소하였다 따라서 비커스 경도와 PIRMP상관관계에 의해 연화곡선을 구할 수 있고, 이 연화곡선에 의해 터빈로터 강의 잔여수명을 평가할 수 있다.

잡음 내성이 향상된 300W 공진형 하프-브리지 컨버터용 고전압 구동 IC 설계 (Design of the Noise Margin Improved High Voltage Gate Driver IC for 300W Resonant Half-Bridge Converter)

  • 송기남;박현일;이용안;김형우;김기현;서길수;한석붕
    • 대한전자공학회논문지SD
    • /
    • 제45권10호
    • /
    • pp.7-14
    • /
    • 2008
  • 본 논문에서는 $1.0{\mu}m$ BCD 650V 공정을 이용하여 향상된 잡음 내성과 높은 전류 구동 능력을 갖는 고전압 구동 IC를 설계하였다. 설계된 고전압 구동 IC는 500kHz의 고속 동작이 가능하고, 입력 전압의 범위가 최대 650V이다. 설계된 IC에 내장된 상단 레벨 쉬프터는 잡음 보호회로와 슈미트 트리거를 포함하고 있으며 최대 50V/ns의 높은 dv/dt 잡음 내성을 가지고 있다. 또한 설계된 숏-펄스 생성회로가 있는 상단 레벨 쉬프터의 전력 소모는 기존 회로 대비 40% 이상 감소하였다. 이외에도 상 하단 파워 스위치의 동시 도통을 방지하는 보호회로와 구동부의 전원 전압을 감지하는 UVLO(Under Voltage Lock-Out) 회로를 내장하여 시스템의 안정도를 향상시켰다. 설계된 고전압 구동 IC의 특성 검증에는 Cadence사의 spectre 및 PSpice를 이용하였다.

커패시터 멀티플라이어를 갖는 CCM/DCM 이중모드 DC-DC 벅 컨버터의 설계 (Design of a CCM/DCM dual mode DC-DC Buck Converter with Capacitor Multiplier)

  • 최진웅;송한정
    • 한국산학기술학회논문지
    • /
    • 제17권9호
    • /
    • pp.21-26
    • /
    • 2016
  • 본 논문에서는 휴대 전자기기의 내부 전원단을 위한, CCM/DCM 기능의 이중모드 감압형 DC-DC 벅 컨버터를 제안한다. 제안하는 변환기는 1 MHz의 주파수에서 동작하며, 파워단과 제어블럭으로 이루어진다. 파워단은 Power MOS 트랜지스터, 인덕터, 커패시터, 제어 루프용 피드백 저항으로 구성된다. 제어부는 펄스폭 변조기 (PWM), 오차증폭기, 램프 파 발생기, 오실레이터 등으로 이루진다. 또한 본 논문에서 보상단의 큰 외부 커패시터는, 집적회로의 면적축소를 위하여 CMOS 회로로 구성되는 멀티플라이어 등가 커패시터로 대체하였다. 또한,. 본 논문에서, 보상단의 외부 커패시터는 집적회로의 면적을 줄이기 위하여 곱셈기 기반 CMOS 등가회로로 대체하였다. 또한 제안하는 회로는 칩을 보호하기 위하여 출력 과전압, 입력부족 차단 보호회로 및 과열 차단 보호회로를 내장하였다. 제안하는 회로는 $0.18{\mu}m$ CMOS 공정을 사용하여, 케이던스의 스펙트라 회로설계 프로그램을 이용하여 설계 및 검증을 하였다. SPICE 모의 실험 결과, 설계된 이중모드 DC-DC 벅 변환기는 94.8 %의 피크효율, 3.29 mV의 리플전압, 2.7 ~ 3.3 V의 전압 조건에서 1.8 V의 출력전압을 보였다.