• Title/Summary/Keyword: lock-in-frequency

Search Result 244, Processing Time 0.02 seconds

A Highly Expandable Forwarded-Clock Receiver with Ultra-Slim Data Lane using Skew Calibration by Multi-Phase Edge Monitoring

  • Yoo, Byoung-Joo;Song, Ho-Young;Chi, Han-Kyu;Bae, Woo-Rham;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.4
    • /
    • pp.433-448
    • /
    • 2012
  • A source-synchronous receiver based on a delay-locked loop is presented. It employs a shared global calibration control between channels, yet achieves channel expandability for high aggregate I/O bandwidth. The global calibration control accomplishes skew calibration, equalizer adaptation, and phase lock of all the channels in a calibration period, resulting in the reduced hardware overhead and area of each data lane. In addition, the weight-adjusted dual-interpolating delay cell, which is used in the multiphase DLL, guarantees sufficient phase linearity without using dummy delay cells, while offering a high-frequency operation. The proposed receiver is designed in the 90-nm CMOS technology, and achieves error-free eye openings of more than 0.5 UI across 9-28 inch Nelco4000-6 microstrips at 4-7 Gb/s and more than 0.42 UI at data rates of up to 9 Gb/s. The data lane occupies only $0.152mm^2$ and consumes 69.8 mW, while the rest of the receiver occupies $0.297mm^2$ and consumes 56.0 mW at the 7- Gb/s data-rate and supply voltage of 1.35 V.

A Study of User Perception on Features Used in Behavior-Based Authentication (행위 기반 인증을 위한 사용자 중심의 인증 요소 분석 연구)

  • Lee, Youngjoo;Ku, Yeeun;Kwon, Taekyoung
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.1
    • /
    • pp.127-137
    • /
    • 2019
  • The growth in smartphone service has given rise to an increase in frequency and importance of authentication. Existing smartphone authentication mechanisms such as passwords, pattern lock and fingerprint recognition require a high level of awareness and authenticate users temporarily with a point-of-entry techniques. To overcome these disadvantages, there have been active researches in behavior-based authentication. However, previous studies focused on enhancing the accuracy of the authentication. Since authentication is directly used by people, it is necessary to reflect actual users' perception. This paper proposes user perception on behavior-based authentication with feature analysis. We conduct user survey to empirically understand user perception regarding behavioral authentication with selected authentication features. Then, we analyze acceptance of the behavioral authentication to provide continuous authentication with minimal awareness while using the device.

Double Demodulation of a Ring Laser Dither Signal for Reducing the Dynamic Error of an Inertial Navigation System (관성항법장치의 동적오차 개선을 위한 링레이저 각진동 신호의 이중 복조방법)

  • Shim, Kyu-Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.1
    • /
    • pp.82-89
    • /
    • 2014
  • This paper discusses the methods for reducing the sampling time quantization errors of the body dither type ring laser gyroscope. A ring laser gyroscope has the angle quantization error which is generated by the frequency counting method of the laser beat signal and sampling time quantization error which is generated by the demodulation method for eliminating the body dithering in which the sampling periods are fitted to the dither periods. Generally, because the dither periods are longer than the calculation periods of the inertial navigation system, vehicle navigation errors are produced by long time attitude update missing during the vehicle move with a high dynamical motion. In this paper, the double demodulation method is proposed for reducing the sampling time quantization error and its effects under the dynamic situation are confirmed by simulation.

Nondestructive Characterization for Remanent Life of Advanced Ferritic Steel by Reversible Permeability (가역투자율에 의한 첨단 페라이트강의 잔여수명에 대한 비파괴평가)

  • Hong, Seung-Pyo;Ryu, Kwon-Sang;Kim, Chung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.181-186
    • /
    • 2013
  • We present nondestructive characterization for remanent life of advanced ferritic steels, next-gen energy facility materials by reversible permeability. The reversible permeability is based on the theory that the value of reversible permeability is the same differential of the hysteresis loop. The measurement principle is based on the foundation of harmonics voltage induced in a sensing coil using a lock-in amplifier tuned to the frequency of the exciting one. The peak interval of reversible permeability(PIRP), Vickers hardness, and tensile strength(TS) of the aged samples decreased with aging time. We could estimate the remanent life of advanced ferritic steel by using the relationship between the peak interval of reversible permeability and Larson-Miller parameter(LMP), non-destructively.

Design of Video Encoder activating with variable clocks of CCDs for CCTV applications (CCTV용 CCD를 위한 가변 clock으로 동작되는 비디오 인코더의 설계)

  • Kim, Joo-Hyun;Ha, Joo-Young;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.1
    • /
    • pp.80-87
    • /
    • 2006
  • SONY corporation preoccupies $80\%$ of a market of the CCD used in a CCTV system. The CCD of SONY have high duality which can not follow the progress of capability. But there are some problems which differ the clock frequency used in CCD from the frequency used in common video encoder. To get the result by using common video encoder, the system needs a scaler that could adjust image size and PLL that synchronizes CCD's with encoder's clock So, this paper proposes the video encoder that is activated at equal clock used in CCD without scaler and PLL. The encoder converts ITU-R BT.601 4:2:2 or ITU-R BT.656 inputs from various video sources into NTSC or PAL signals in CVBS. Due to variable clock, property of filters used in the encoder is automatically changed by clock and filters adopt multiplier-free structures to reduce hardware complexity. The hardware bit width of programmable digital filters for luminance and chrominance signals, along with other operating blocks, are carefully determined to produce hish-quality digital video signals of ${\pm}1$ LSB error or less. The proposed encoder is experimentally demonstrated by using the Altera Stratix EP1S80B953C6ES device.

A Study on the Precise End-Point Detection in Titration by Using the Phase Angle Measurements (위상각 측정에 의한 적정의 정확한 종말점 검출법에 관한 연구)

  • Park, Byung-Bin;Shin, Ho-Sang;Lee, Han-Hyoung
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.290-298
    • /
    • 1999
  • A study on the application of impedance phase angle for redox titration, acid-base titration, chelate titration and precipitation titration has been carried out. A constant alternating current was passed between two platinum electrodes. One of them was a polarizable micro-electrode of $0.1cm^2$ or $0.026cm^2$ surface area and the other a non-polarizable large electrode of $1cm^2$ surface area dipped in the solution to be titrated. The impedance and the phase angle of the titration cell were measured with lock-in amplifier to obtain well behaved titration curve respectively. In titration of oxalic acid vs. potassium permanganate, the end-point was obtained successfully from the phase angle titration curve. In this experiment, the concentration of 0.0005 M to 0.05 M, the current of $50{\mu}A$ and the frequency of near 50 Hz were used. In titration of phosphoric acid vs. sodium hydroxide, the first end-point was obtained successfully on the optimum experimental condition of 0.001 M concentration, $50{\mu}A$ current and 25~97 Hz frequency. However, the end-point in titration of cupric sulfate vs. disodium-EDTA couldn't be obtained clearly. The end-point was obtained with the out-of-phase impedance curve on the experimental condition of 0.01 M concentration, $100{\mu}A$ current, 5~35 Hz frequency range. In titration of sodium chloride vs. silver nitrate, the end-point was obtained successfully on the experimental condition of 0.1 M concentration, $100{\mu}A$ current and 5~47 Hz frequency range. This study showed that the impedance phase angle was applicable for the detection of the end-points in redox titration curve, acid-base titration curve, chelate titration curve and precipitation titration curve.

  • PDF

A Study on the Sounds and Vibrations of the Temporomandibular Joint using Electrovibratography (전자 진동술을 이용한 악관절의 잡음과 진동에 관한 연구)

  • Seok-Man Kang;Kyung-Soo Han;Min Shin
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.141-158
    • /
    • 1995
  • This study was performed to invetigate the relationship between clinical manifestations related to temporomandibular joint sounds and temporomandibular joint vibrations that occurred synchronously with sounds. There have been reported in many articles that joint sounds indicate internal joint pathology. Therefore, it is necessary to evaluate type and patterns of joint sounds, and radiographic changes of temporomandibular joint(TMJ) in order to diagnose and deal with the Temporomandibular Disorders(TMD). For this study 142 patients with TMDs were collected and they were examined by routine diagnostic procedure for TMDs. The author classified TMJ sounds clinically into 3 types : click, popping, and crepitus. Transcranial and panoramic radiographs were taken for observein bony changes of TMJ, and for observing vibrations of TMJ Sonopak of Biopak system was used. The obtained results were as follows : 1. Female subjects with crepitus were older than those with click or popping and their mean ages were about 45 years old. But in male subjects, there was no age difference. 2. For all subjects, mean value of maximal mouth opening were above 40mm, which are lower limit of normal vertical opening. But in subjects with L-type opening deviation, mouth opening capacity were about 36mm of range. 3. Symptom duration stated when patient presented first were slightly longer in subjects with crepitus but there were no statistical differences. And there were also no radiographic differences among 3 types of joint sounds in regard to symptom duration. 4. In subjects wih click, it might have been interpreted that 12% had closed lock, 12% had degenerative joint disease, and about 17% of he subjects had normal joints by Sonopak. 5. There were no significant relationships between subjective loudness of joint sounds and magnitude of joint vibrations. 6. The highest value of Integral and peak amplitude were observed in popping sounds and though it was not significant, value of peak frequency was highest in crepitus. 7. Amount of mandibular positional change were differed between click and crepitus on frontal plane, between click, crepitus and popping on horizontal plane in rotational movement, respectively. However, there no difference among them in translational movements.

  • PDF

Current 2-Block Haircut Styles and Preferences in Men (남성의 투블럭 커트 스타일 이용실태 및 선호도)

  • Sim, Eun-Hong;Lim, Sun-Nye
    • Journal of Industrial Convergence
    • /
    • v.18 no.4
    • /
    • pp.111-123
    • /
    • 2020
  • This study analyzed current use of 2-block haircut styles and preferences for accurate understanding of the haircut and enhancement of its efficiency. For this, a questionnaire survey was performed against 441 men in their 20~40s living in Jeollanam-do from June 27 to July 6, 2019. A total of 430 copies were used for final analysis. The collected data were analyzed by frequency analysis and cross-tabulation analysis, using SPSS 21.0, and the results found the followings: When asked about the factors affecting their choice of the haircut, 58.4% (20~40s in age) responded, 'my own decision'. Second, 61.2% said that they were interested in a 2-block haircut, and 54.7% responded that they had the haircut before. Among them, 92.3% said that they were satisfied with the trendy undercut. The above results confirm that men's appearance management is now essential, considering changes in social environments. People envision their hairstyle and visit a hair salon based on their own will, not after recommendation from their acquaintances. Many customers prefer a 2-block haircut because they believe it looks good on them. In addition, they choose the easy-to-care undercut to have a clean and neat image. It is anticipated that the study results would make a contribution to suggesting basic academic data and enhancing sales in a 2-lock haircut which is expected to remain popular. Therefore, it proposes in-depth studies on new 2-block haircut styles for women.

A PN-code Acquisition method Using Array Antenna Systems for CDMA2000 1x (CDMA2000 1x용 배열 안테나 시스템에서 PN 동기 획득 방법)

  • Jo, Hee-Nam;Yun, Yu-Suk;Choi, Seung-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.8 s.338
    • /
    • pp.33-40
    • /
    • 2005
  • This paper presents a structure of the searcher using a diversity in array antenna systems operating in the cdma2000 1x signal environments. The new technique exploits the fact that the In-phase and quadrature components of interferers can respectively be viewed as an independent gaussian noise at each antnna element in most practical cdma signal environments. The proposed PN acquisition scheme is a singles-dwell PN acquisition system consisting of two stages, that is, the searching stage and the verification stage. The searching stage independently correlates the receiver multiple signals with PN generator of each antenna element for obtaining the synchronous energy at the entire region. Then, the searching results of each antenna element are non-coherently combinind. The verification stage compares the searching energy with the optimal threshold, which is predesigned in the lock detector, and decides whether the acquisition is successful or fail. In this paper, we analyzed the effect of tile diversity order to determine the mean acquisition time. In general, it is known that the mean acquisition time significantly decrease as the number of antenna elements increases. But, as the diversity order goes up, the enhancement of the performance is saturated. Therefore, to decrease the mean acquisition time of the searcher, we must design the optimal array antenna systems by considering the operating SNR range of the receiver, the probability of detection $P_D$ and that of false alarm $P_{FA}$ . The Performance of the proposed PN acquisition scheme is analyzed in frequency selective Rayleigh fading channels. In this paper, the effect of the number of antenna elements on PN acquisition scheme is shown according to the probability of detection $P_D$ and that of false alarm $P_{FA}$.

Degradation Evaluation of Mechanical Properties for 12Cr Ferrite Heat Resisting Steel by Reversible Permeability (가역투자율에 의한 12Cr 페라이트 내열강의 역학적 물성의 열화평가)

  • Ryu, Kwon-Sang;Kim, Min-Gi;Nahm, Seung-Hoon;Kim, Chung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.464-470
    • /
    • 2010
  • The integrity of the industrial equipment in use under high temperature and high pressure must be assessed by regularly measuring the degraded mechanical properties during service time. In order to nondestructively monitor the degraded mechanical properties of industrial equipment, a measuring method of the reversible permeability(RP) using surface type probe is presented. The method for measuring the RP is based on that RP is the differential value of hysteresis loop. The RP is exactly the foundation hatmonics induced in a detecting coil measured by lock-in amplifier tuned to a frequency of the alternating perturbing magnetic field. The peak of RP is measured around the coercive force. Steel material used in this work was 12Cr ferritic heat resisting steel. The eleven kinds of samples aged during different times under same temperature ($700^{\circ}C$) were prepared. Peak interval of reversible permeability(PIRP), Vickers hardness, and tensile strength measured for the aged samples decreased abruptly for short aging time (below 500 h), but the change became small at a long aging time. Vickers hardness and tensile strength linearly decreased as RIRP decreased, so the degraded mechanical properties of 12Cr ferritic heat resisting steel could be nondestructively evaluated by measuring RIRP.