• Title/Summary/Keyword: location detection

Search Result 1,591, Processing Time 0.025 seconds

The Development of Integration Electronic Block System for Maintenance Efficiency on Railway Wayside Signalling System (철도 선로변 신호설비 유지보수 효율화를 위한 집중형 전자폐색제어장치 개발)

  • Baek, Jong-Hyen;Jo, Hyun-Jeong;Kim, Yong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4171-4176
    • /
    • 2012
  • The conventional block systems for railway signaling currently in operation in Korea have not been electrified or integrated and therefore there have been difficulties in terms of construction and maintenance. Two independent systems have been installed for ABS and LEU of ATP system (for speeded-up lines), although they deal with the same signaling information at the same location in order to control the trains. In these conventional ABS and LEU, a number of duplicate modules are installed in each device including lamp detection units and power supply units and it results increased manufacturing costs and maintenance efforts. This paper deals with the prototype development of integrated electronic block system with CPU-based digital control methods in order to overcome the limitations of the conventional ABS. The suggested system is the integration of the conventional ABS with LEU of ATP and it is also applicable for the non-ATP sections as well.

UHF Sensor Location Optimization for Partial Discharge Signals Detection Method (UHF 센서 위치 최적화로 부분방전 신호 검출 방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.409-413
    • /
    • 2014
  • GIS partial discharge that occurred in the UHF band signal is effectively detected by the method to IEC60270 5pc the apparent minimum discharge can be detected over the GIS arrangement of the sensor interior and exterior of the UHF in accordance with the optimized position signal by considering the damping ratio is selected so that the signals can be obtained to be mounted. 362kV, 800kV GIS is installed on the internal and external sensors are UHF band signal attenuation is set by measuring the reference value, but the operation, 170kV case 362kV, 800kV on the basis of the measurement data and to be installed and operated. When 170kV per 1Bay by installing the built-in sensor 1 for detecting a partial discharge signal, But, GIS signal attenuation is large in the case of an internal partial discharge signal is not detected in some cases. Where the attenuation is great UHF signal of the sensor by increasing the quantity of partial discharge signals were acquired to allow relocation. The greater the spacing between the sensor and the sensor is applied simplifies the installation and reduces the cost in terms of maintenance of appropriate optimal position is calculated to detect the partial discharge signal is needed. Thus 170kV GIS signal power attenuation of a partial discharge by measuring the UHF sensor, and by relocating the proper position is calculated in accordance with the sensor signal decay rate and minimize the error of omission in detecting a partial discharge signal was optimized.

Partial Discharge Position Tracking Method using a GIS Partial Discharge Signal and Arrival Time Difference (GIS 부분방전 신호와 도착 시간차 분석을 통한 PD발생 위치 추적)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1297-1301
    • /
    • 2013
  • This paper analyzes of PD occurrence position through an analysis of the arrival time difference between the GIS partial discharge signal. Because of GIS (Gas Insulated Switchgear) is a facility very important power equipment and as part of the equipment that make up the power system, the stabilization of the power industry, which accounted for 88.5% share of GIS substation in the form of a substation is an important equipment for power supply. In the situation where we are gradually expanding the need for preventive diagnosis in order to improve the efficiency of equipment management and failure prevention for Preventive diagnosis. In this paper as a method for extracting pre-defect of failure of GIS Apply the average value method of calculating the 5 times each using a pulse of the first time of the second pulse (${\Delta}t$) with an oscilloscope generation position PD(Partial Discharge). the results of GIS internal inspection, the partial discharge of the actual the position of the partial discharge was confirmed with an accuracy of about 82% of positions. Arrival time difference in the most effective manner if the partial discharge of GIS internal occurs by applying the averaging method and TOA(Time of arrival) method, the partial discharge occurs you through the measurement and analysis of PD signal occurs was confirmed in the experiment are presented and diagnostic methods location tracking.

Implementation of a bio-inspired two-mode structural health monitoring system

  • Lin, Tzu-Kang;Yu, Li-Chen;Ku, Chang-Hung;Chang, Kuo-Chun;Kiremidjian, Anne
    • Smart Structures and Systems
    • /
    • v.8 no.1
    • /
    • pp.119-137
    • /
    • 2011
  • A bio-inspired two-mode structural health monitoring (SHM) system based on the Na$\ddot{i}$ve Bayes (NB) classification method is discussed in this paper. To implement the molecular biology based Deoxyribonucleic acid (DNA) array concept in structural health monitoring, which has been demonstrated to be superior in disease detection, two types of array expression data have been proposed for the development of the SHM algorithm. For the micro-vibration mode, a two-tier auto-regression with exogenous (AR-ARX) process is used to extract the expression array from the recorded structural time history while an ARX process is applied for the analysis of the earthquake mode. The health condition of the structure is then determined using the NB classification method. In addition, the union concept in probability is used to improve the accuracy of the system. To verify the performance and reliability of the SHM algorithm, a downscaled eight-storey steel building located at the shaking table of the National Center for Research on Earthquake Engineering (NCREE) was used as the benchmark structure. The structural response from different damage levels and locations was collected and incorporated in the database to aid the structural health monitoring process. Preliminary verification has demonstrated that the structure health condition can be precisely detected by the proposed algorithm. To implement the developed SHM system in a practical application, a SHM prototype consisting of the input sensing module, the transmission module, and the SHM platform was developed. The vibration data were first measured by the deployed sensor, and subsequently the SHM mode corresponding to the desired excitation is chosen automatically to quickly evaluate the health condition of the structure. Test results from the ambient vibration and shaking table test showed that the condition and location of the benchmark structure damage can be successfully detected by the proposed SHM prototype system, and the information is instantaneously transmitted to a remote server to facilitate real-time monitoring. Implementing the bio-inspired two-mode SHM practically has been successfully demonstrated.

Simulation of PZT monitoring of reinforced concrete beams retrofitted with CFRP

  • Providakis, C.P.;Triantafillou, T.C.;Karabalis, D.;Papanicolaou, A.;Stefanaki, K.;Tsantilis, A.;Tzoura, E.
    • Smart Structures and Systems
    • /
    • v.14 no.5
    • /
    • pp.811-830
    • /
    • 2014
  • A numerical study has been carried out to simulate an innovative monitoring procedure to detect and localize damage in reinforced concrete beams retrofitted with carbon fiber reinforced polymer (CFRP) unidirectional laminates. The main novelty of the present simulation is its ability to conduct the electromechanical admittance monitoring technique by considerably compressing the amount of data required for damage detection and localization. A FEM simulation of electromechanical admittance-based sensing technique was employed by applying lead zirconate titanate (PZT) transducers to acquire impedance spectrum signatures. Response surface methodology (RSM) is finally adopted as a tool for solving inverse problems to estimate the location and size of damaged areas from the relationship between damage and electromechanical admittance changes computed at PZT transducer surfaces. This statistical metamodel technique allows polynomial models to be produced without requiring complicated modeling or numerous data sets after the generation of damage, leading to considerably lower cost of creating diagnostic database. Finally, a numerical example is carried out regarding a steel-reinforced concrete (RC) beam model monotonically loaded up to its failure which is also retrofitted by a CFRP laminate to verify the validity of the present metamodeling monitoring technique. The load-carrying capacity of concrete is predicted in the present paper by utilizing an Ottosen-type failure surface in order to better take into account the passive confinement behavior of retrofitted concrete material under the application of FRP laminate.

Tag Mis-recognition Detection using RFID Tag Sensitivity in Logistics System (물류 시스템에서 RFID 태그 수신감도를 이용한 태그 오인식 검출)

  • Kim, Youngmin;Kang, Euisun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.9-17
    • /
    • 2015
  • One of RFID features is that each RFID tag has a unique identifying code. Logistic System utilizes RFID tag as location tracing, understanding stock or etc. On the other hand, there is a problem of overall lower recognition rate by getting the information of non-mobility tags with no need for reading. To solve this problem, we trace and analyze variation of moving and moveless RFID tag sensitivity by the hour. In analyzed data, we verify that tag sensitivity of mobile RFID is gradually increase while non-mobility tag has same intensity value. In order to detect mobile tag, we generate a function using Matlab with analyzed data and separate moving tags from non-mobility tags by software. As a result, we can confirm that non-mobility tags are detected by software and recognition rate of RFID tag is improved by separating moveless tag.

A Real-time Audio Surveillance System Detecting and Localizing Dangerous Sounds for PTZ Camera Surveillance (PTZ 카메라 감시를 위한 실시간 위험 소리 검출 및 음원 방향 추정 소리 감시 시스템)

  • Nguyen, Viet Quoc;Kang, HoSeok;Chung, Sun-Tae;Cho, Seongwon
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.11
    • /
    • pp.1272-1280
    • /
    • 2013
  • In this paper, we propose an audio surveillance system which can detect and localize dangerous sounds in real-time. The location information about dangerous sounds can render a PTZ camera to be directed so as to catch a snapshot image about the dangerous sound source area and send it to clients instantly. The proposed audio surveillance system firstly detects foreground sounds based on adaptive Gaussian mixture background sound model, and classifies it into one of pre-trained classes of foreground dangerous sounds. For detected dangerous sounds, a sound source localization algorithm based on Dual delay-line algorithm is applied to localize the sound sources. Finally, the proposed system renders a PTZ camera to be oriented towards the dangerous sound source region, and take a snapshot against over the sound source region. Experiment results show that the proposed system can detect foreground dangerous sounds stably and classifies the detected foreground dangerous sounds into correct classes with a precision of 79% while the sound source localization can estimate orientation of the sound source with acceptably small error.

Clinicopathologic Characteristics of Male Breast Cancer: A Report of 21 Cases in Radiotherapy Center of Hamedan, Iran

  • Sedighi, Abdolazim;Hamed, Ehsan Akbari;Mohammadian, Kamal;Behnood, Sepideh;Kalaghchi, Bita
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7381-7383
    • /
    • 2013
  • Background: Male breast cancer accounts for less than 1% of all cancer in men and only around 1% of all diagnosed breast cancer. Despite a significant raise in the last 25 years, it still remains a rare disease. Materials and Methods: We conducted a retrospective study from 2004-2011 with 21 male breast cancer patients. We aimed to analyze the epidemiologic data (age, personal and family history), tumor characteristics (size, histological type, location, TNM stage, receptors), surgery, adjuvant chemotherapy and radiation therapy, hormonal therapy and survival (relapse, follow up, death) who reffered to our center with breast cancer. Results: The median age was $49.2{\pm}14.2$ years (range 30-83 years). A family history of breast cancer was noted in four cases. The main clinical complaint was a retroareolar mass in 85.7%of patients (n=18). Histologically, 85.7% (n=18)were invasive ductal carcinoma and 4.7% (n=1) had ductal carcinoma in situ and 9.4% (n=2) had mixed histology including invasive medullary and ductal carcinoma. Hormonal therapy was delivered to 16 cases (76.1%) due to ER or PR positivity. During median follow up of 30 months (3-84 month), distant metastases were evident in 4 cases (19%). During the follow-up period, only one patient died due to metastatic disease. The mean time to recurrence detection was 30 months. Conclusions: The percentage of cases of male breast cancer is very low compared to breast cancer in females, explaining why very few investigations have been conducted in Iran. Limited coverage in the literature make gender-specific findings difficult so future research of this entity involving multi-institutional cooperation and longer follow up is essential to provide new insights about the biological and clinical factors of this rare cancer.

Capture of Foot Motion for Real-time Virtual Wearing by Stereo Cameras (스테레오 카메라로부터 실시간 가상 착용을 위한 발동작 검출)

  • Jung, Da-Un;Yun, Yong-In;Choi, Jong-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.11
    • /
    • pp.1575-1591
    • /
    • 2008
  • In this paper, we propose a new method detecting foot motion capture in order to overlap in realtime foot's 3D virtual model from stereo cameras. In order to overlap foot's virtual model at the same position of the foot, a process of the foot's joint detection to regularly track the foot's joint motion is necessary, and accurate register both foot's virtual model and user's foot in complicated motion is most important problem in this technology. In this paper, we propose a dynamic registration using two types of marker groups. A plane information of the ground handles the relationship between foot's virtual model and user's foot and obtains foot's pose and location. Foot's rotation is predicted by two attached marker groups according to instep of center framework. Consequently, we had implemented our proposed system and estimated the accuracy of the proposed method using various experiments.

  • PDF

Fragile Watermarking for Image Authentication and Detecting Image Modification (영상 인증과 변형 검출을 위한 Fragile 워터마킹)

  • Woo, Chan-Il;Jeon, Se-Gil
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.459-465
    • /
    • 2009
  • Digital watermarking is a technique to insert a visually imperceptible information into an image so that the information can be extracted for the purposes of ownership verification or authentication. And watermarking techniques can be classified as either fragile or robust. Robust watermarks are useful for copyright and ownership assertion purposes. They cannot be easily removed and should resist common image manipulation procedures such as rotation, scaling, cropping, etc. On the other hand, fragile watermarks are easily corrupted by any image processing procedure, it can detect any change to an image as well as localizing the areas that have been changed. In this paper, we propose a fragile watermarking algorithm using a special hierarchical structure for integrity verification of image and detection of manipulated location. In the proposed method, the image to be watermarked is divided into blocks in a multi-level hierarchy and calculating block digital signatures in this hierarchy. The proposed method thwarts the cut-and-paste attack and the experimental results to demonstrate the effectiveness of the proposed method.

  • PDF