• Title/Summary/Keyword: location assessment

Search Result 751, Processing Time 0.031 seconds

A structural health monitoring system based on multifractal detrended cross-correlation analysis

  • Lin, Tzu-Kang;Chien, Yi-Hsiu
    • Structural Engineering and Mechanics
    • /
    • v.63 no.6
    • /
    • pp.751-760
    • /
    • 2017
  • In recent years, multifractal-based analysis methods have been widely applied in engineering. Among these methods, multifractal detrended cross-correlation analysis (MFDXA), a branch of fractal analysis, has been successfully applied in the fields of finance and biomedicine. For its great potential in reflecting the subtle characteristic among signals, a structural health monitoring (SHM) system based on MFDXA is proposed. In this system, damage assessment is conducted by exploiting the concept of multifractal theory to quantify the complexity of the vibration signal measured from a structure. According to the proposed algorithm, the damage condition is first distinguished by multifractal detrended fluctuation analysis. Subsequently, the relationship between the q-order, q-order detrended covariance, and length of segment is further explored. The dissimilarity between damaged and undamaged cases is visualized on contour diagrams, and the damage location can thus be detected using signals measured from different floors. Moreover, a damage index is proposed to efficiently enhance the SHM process. A seven-story benchmark structure, located at the National Center for Research on Earthquake Engineering (NCREE), was employed for an experimental verification to demonstrate the performance of the proposed SHM algorithm. According to the results, the damage condition and orientation could be correctly identified using the MFDXA algorithm and the proposed damage index. Since only the ambient vibration signal is required along with a set of initial reference measurements, the proposed SHM system can provide a lower cost, efficient, and reliable monitoring process.

Prediction of the Combustion Performance in the Coal-fired Boiler using Response Surface Method (반응표면법을 이용한 석탄 화력 보일러 연소특성 예측)

  • Shin, Sung Woo;Kim, Sin Woo;Lee, Eui Ju
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.27-32
    • /
    • 2017
  • The experimental design methodology was applied in the real scale coal-fired boiler to predict the various combustion properties according to the operating conditions and to assess the coal plant safety. Response surface method (RSM) was introduced as a design of experiment, and the database for RSM was provided with the numerical simulation of the coal-fired boiler. The three independent variables, high heating value of coal (HHV), overall stoichiometry excess air ratio (OST), and burner-side stoichiometry excess air ratio (BST), were set to characterize the cross section averaged NOx concentration and temperature distribution. The maximum NOx concentration was predicted accurately and mainly controlled by BST in the boiler. The parabola function was assumed for the zone averaged peak temperature distribution, and the prediction was in a fairly good agreement with the experiments except downstream. Also, the location of the peak temperature was compared with that of maximum NOx, which implies that thermal NOx formation is the main mechanism in the coal-fired boiler. These results promise the wide use of statistical models for the fast prediction and safety assessment.

Dynamic characteristics assessment of reactor vessel internals with fluid-structure interaction

  • Je, Sang Yun;Chang, Yoon-Suk;Kang, Sung-Sik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1513-1523
    • /
    • 2017
  • Improvement of numerical analysis methods has been required to solve complicated phenomena that occur in nuclear facilities. Particularly, fluid-structure interaction (FSI) behavior should be resolved for accurate design and evaluation of complex reactor vessel internals (RVIs) submerged in coolant. In this study, the FSI effect on dynamic characteristics of RVIs in a typical 1,000 MWe nuclear power plant was investigated. Modal analyses of an integrated assembly were conducted by employing the fluid-structure (F-S) model as well as the traditional added-mass model. Subsequently, structural analyses were carried out using design response spectra combined with modal analysis data. Analysis results from the F-S model led to reductions of both frequency and Tresca stress compared to those values obtained using the added-mass model. Validation of the analysis method with the FSI model was also performed, from which the interface between the upper guide structure plate and the core shroud assembly lug was defined as the critical location of the typical RVIs, while all the relevant stress intensities satisfied the acceptance criteria.

The Sediment Transport Pattern from a Large Industrial Complex to an Enclosed Bay

  • Kwon, Young-Tack;Lee, Chan-Won
    • Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.69-72
    • /
    • 2008
  • The movement of sediments in the stream crossing a large industrial complex to the mouth of Masan Bay was monitored for eight years. Sediment samples were seasonally collected in the period of $1992{\sim}1997$ and $2001{\sim}2002$. The heavy metal content of sediment was found to be higher at dry season with the peak on February and significantly decreased at rainy season. Metals content in stream sediments were rapidly decreased by large precipitation events in rainy season because the contaminants in the upstream sediments were transported to the dredged area of Masan Bay where is a typical enclosed bay in Korea. The increasing and decreasing tendency of heavy metals in sediment was repeatedly observed for six consecutive years. The heavy metals assessment of stream sediment provide us the information about the pollutant source, transport pattern and control strategy along the industrial complex. It was strongly suggested that the transportable stream sediments of an industrial area should be controlled as one of the important strategies to restore and manage the enclosed bay. Combined wastewaters have been collected and treated in a publicly owned treatment works (POTW) after industrial wastewater treatment at each location of industries since 1994. A field study was conducted to investigate the pollutant removal efficiency and performance of contact oxidation system installed and operated in two locations in the stream. The stream sediment quality was improved since then, and as a consequence the habitat of the estuary has been restored.

Seawater Intrusion due to Ground Water Developments in Eastern and Central Cheju Watersheds (중-동 제주 수역의 지하수 개발로 인한 해수침투)

  • 박남식;이용두
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.1
    • /
    • pp.5-13
    • /
    • 1997
  • The Island of Cheju plans massive ground water development to meet predicted water demand. Effective management of ground water resources requires impact assessment study. Due to the nature of the island, effects of sea water must be considered. In this work, salt water intrusion, due to hypothetical ground water development in Eastern and Central Cheju Watersheds, is predicted using a sharp-interface model. The model considers simultaneously hydrodynamics of both freshwater and saltwater. The hypothetical ground water development was designed such that it follows closely the regional ground water development plan. The numerical model predicted that the saltwater wedge may intude over 1km depending on the location. This observation leaves doubt on impact assement studies based on freshwater-flow only modeling.

  • PDF

Assessment of Fracture Behaviors for CIP Anchors Fastened to Cracked and Uncracked Concretes

  • Yoon, Young-Soo;Kim, Ho-Seop;Kim, Sang-Yun
    • KCI Concrete Journal
    • /
    • v.13 no.2
    • /
    • pp.33-41
    • /
    • 2001
  • This paper presents the crack effect on CIP anchors and prediction of tensile capacity, as governed by concrete cone failure. Single anchors where located at center of concrete specimen. Three different types of cracks such as crack width of 0.2 mm and 0.5 mm, crack depth of 10 cm and 20cm , and crack location of center and off-center point were simulated. Static tensile load was applied to 7/8-in. CIP anchors of 10 cm and 20 cm embedment length in concrete with compressive strength of 280 kgf/$\textrm{cm}^2$. Tested pullout capacities were compared to the values determined using current design methods (such as ACI 349-97, ACI 349 revision and CEB-FIP which is based on CCD Method). The comparison of CCD Method and ACI revision showed almost the same values in uncracked concrete specimen. In cracked concrete, CCD Method predicted conservative values. Three-dimensional non-linear FEM modeling also has been performed to determine the stresses distribution and crack inclination.

  • PDF

Analysis of Wind Sector Division for Pohang Area - Part I : Coarse Division of Wind Sector for Pohang Area Using Meteorological Observation Data - (포항지역에 대한 바람권역 분석 -Part I : 기상관측자료를 토대로 분석한 성긴 바람권역 분석-)

  • Jung, Jong-Hyeon;Leem, Heon-Ho;Leem, Hwa-Woon;Chang, Hyuk-Sang;Shon, Byung-Hyun
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.385-396
    • /
    • 2008
  • The air quality data is important for understanding and analyzing a surrounding influence. In that light, it is positively necessary for a propriety assessment to determine a location of the air quality monitoring sites. In this study, the climate analysis about temperature and wind, using the meteorological data in the Pohang, is conducted to do that. In the next stage, we distinguished the wind by east-west or north-south component, which has less correlation than temperature, analyzed and divided the wind sector. As the result, the wind circumstance of the Pohang is divided into major 5 wind sector; that is the urban area, the northeast coastal area, the east ocean and the west mountainous area. We think that an analysis on detailed wind sector by utilizing the numerical simulation is needed.

A Study on a Installation Siting for GBAS Category-I Ground System Implementation in Gimpo Airport (GBAS Cat-I 지상시스템 시범공항 구축을 위한 설치후보지 검토)

  • Bae, Joong-Won;Jeong, Myeong-Sook;Choi, Chul Hee;Ko, Wan-Jin;Ko, Youri;Jun, Hyang-Sig
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.4
    • /
    • pp.21-30
    • /
    • 2012
  • This paper presents site survey processes and the results for installing GBAS Category-I ground system into Gimpo international airport. For siting assessment, many things should be taken into account in advance, such as installation requirement of GBAS components, future airport development plan and possible interference effects to existing facilities. Because overall performance of GBAS system can be affected by GPS signal reception environment, on-site survey should be performed carefully to measure actual GPS environmental performance and determine if any adverse multipath or RFI problems exist or not. In addtion, VDB antenna should be located to ensure line of sight for transmitting VHF signal to deliver GBAS message to aircraft. Based on the survey results, final location for GBAS system installation is selected near runway 32 in the Gimpo airport.

Assessment of Long-Term Effectiveness of Speed Monitoring Displays on Speed Variation (어린이보호구역에 과속경보시스템 적용에 따른 장기적 속도변화 평가)

  • Lee, Sang-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.3 s.75
    • /
    • pp.107-113
    • /
    • 2006
  • Speeding is one of major causes of frequent and severe traffic accidents in school zones. In this paper, the long-term effectiveness of speed monitoring displays (SMD) on speed variability was investigated through a field study in a school zone environment. The performance difference was discussed with several dependent variables including average speed, 85th percentile speed, and distribution of speed. Study results showed that the speed of vehicles began to reduce where the driver recognized the presence of an SMD, and about 12.4 percent (5.8km/h) of average speed was reduced at the SMD location. This speed reduction was observed throughout the day regardless of time of day. Statistical tests showed that the speed difference was statistically significant. In addition, analysis results of speed distribution showed that the number of speeding vehicle was greatly reduced after the SMD was installed, and 85th percentile speed also decreased from 54.3km1h to 45.0km/h. Therefore, it was concluded that the application of SMD produced a positive impact on the driver's behavior for a long period of times.

Comprehensive Evaluation of Water-Reservoir Measuring Equipment for Highway Safety Analysis (도로 노면 안전성 분석을 위한 물고임 측정장비 개발 및 현장 적용성 연구)

  • Lee, Jin Kak;Yun, Duk Geun;Joh, Young-Oh
    • International Journal of Highway Engineering
    • /
    • v.15 no.3
    • /
    • pp.127-135
    • /
    • 2013
  • PURPOSES : The purpose of this study is development of automatic equipment to measure the road water-reservoir which can be one of factors for road traffic safety inspection and its application to safety analysis. METHODS : The scopes of this study are the examination of the riskiness and location of road water-reservoir through literature review, development of appropriate sensor and automatic equipment to survey the road water-reservoir and evaluation of field application. RESULTS: The laser lighting and IR camera were selected to develop the equipment. It was found from the field calibration that there is a high correlation between rutting and road water-reservoir and road water-reservoir caused by rutting can be correctly calculated. About 20.2km of national highway were inspected for case study and field application. It was found from correlation of traffic incident that 2.08km of the latent length for water-reservoir which is related to 12 traffic incidents were analyzed. CONCLUSIONS : This technique can be utilized evaluation method for road condition such as road water-reservoir for conventional evaluation system such as road traffic safety assessment and safety analysis and it can be use to new evaluation system to apply various road condition and traffic condition.