• Title/Summary/Keyword: location analysis

Search Result 7,138, Processing Time 0.032 seconds

A Study on Structural Analysis of Reinforced Longitudinal Rib in Orthotropic Steel Deck Bridge (보강된 세로리브에 의한 강바닥판교의 응력변화 연구)

  • Kong, Byung-Seung;Kim, Min-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.468-475
    • /
    • 2007
  • The Steel deck a structural analysis in head plate form change the objective bridge which it sells it accomplished a detailed structural analysis from the research which it sees and Bulk-head plate it accomplished. The length rib where the fatigue crack which is considerable generally occurs, width rib connection department and the length rib side, the width rib side it compares principal stress in the object and it does to sleep. It applied the grudge element model which it describes consequently after words and a load and a boundary condition and it executed it compared a static test and principal stress. It grasped the stress conduct of the The Steel deck petal which it follows in hand weaving rib affix location and the affix location to sleep in order to analyze a same location Bulk-head the head and comparison considered. From the detailed section which is reinforced with the stress investigation result hand weaving rib of the location which is weak in structural analysis result fatigue crack of form star reinforcement details basic form and Bulk-head the form which is reinforced with the head plate compared to principal stress investigation hour it is judged at the section which separates most.

  • PDF

FEM acoustic modal analysis due to location of acoustic baffles to avoid acoustic resonance in the tube bank of boiler for power plant (보일러 튜브군의 음향공진 회피를 위한 음향배플의 위치에 따른 FEM 음향모드해석)

  • Ahn, Sung-Jong;Ju, Young-Ho;Kim, Cheol-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.150-154
    • /
    • 2012
  • A flow induced mechanical vibration and acoustic resonance should be considered at design stage because they are mainly occurred in the tube bank of boiler. Acoustic resonance is occurred when the vortex shedding frequency of tube bank coincides with the acoustic natural frequency of the cavity. Effective solution to avoid acoustic resonance is installing acoustic baffles in the tube banks parallelly inside of the flow cavity. Thus, location and number of acoustic baffles should be exactly calculated to eliminate the acoustic resonance. This paper presents case study of acoustic resonance due to inappropriate number and location of acoustic baffles. Measured frequency and mode in the study is verified by FEM acoustic modal analysis. The number and location of acoustic baffles to avoid acoustic resonance are calculated by using FEM acoustic modal analysis.

  • PDF

The Effect of Economic and Infrastructure Factors on the Formation of Electric Vehicle Supply Chain and Optimal Location Selection: Korea-US FDI

  • Young-Kyou Ha
    • Journal of Korea Trade
    • /
    • v.27 no.5
    • /
    • pp.23-40
    • /
    • 2023
  • Purpose - This study aims to present the changes and directions in the automotive supply chain in the face of changes in the global supply chain caused by external factors and the integration of industries resulting from internal factors. Assuming FDI in the Korean automotive industry in the US, this study analyzed the influential factors over the long term and derived the optimal location. Design/methodology - For this analysis, the characteristics and current status of the automotive industry are presented. Additionally, the study emphasizes the necessity and direction of change. The factors influencing Korea-US FDI in the automotive industry and the electric vehicle industry were analyzed through panel analysis. The optimal location from the perspective of distribution costs was selected using linear programming under the assumption that local demand will be replaced by local production in the future. Findings - This study found that the electric vehicle supply chain will change with the characteristics of the electric and electronic industries rather than with the traditional automotive industry. Additionally, in deriving the optimal location, the study emphasized the proximity to the consumption market. Originality/value - The analysis method and conclusions of this study not only present the influential factors and direction of FDI in the automotive industry but also can be applied to other industries. Moreover, the study provides practical and policy implications for industries and governments considering FDI in the US.

A Study on Comparison with the Methods of Ordered Categorical Data of Analysis (순서 범주형 자료해석법의 비교 연구)

  • 김홍준;송서일
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.44
    • /
    • pp.207-215
    • /
    • 1997
  • This paper deals with a comparison between Taguchi's accumulation analysis method and Nair test on the ordered categorical data from an industrial experiment for quality improvement. a result of Taguchi's accumulation analysis method is shown to have reasonable power for detecting location effects, while Nair test identifies the location and dispersion effects separately, Accordingly, Taguchi's accumulation analysis needs to develop methods for detecting dispersion effects as well as location effects. In addition this paper rewmmends models for analyzing ordered categorical data, for examples, the cumulative legit model, mean response model etc Successively simple, reasonable methods should be introduced more likely to be used by the practitioners.

  • PDF

A Study on the Analysis of Export Structure in Jeollabuk-do for the Activation of Saemangeum New Port (새만금신항 활성화를 위한 전라북도 수출구조 분석에 관한 연구)

  • Min-Ju Song
    • Korea Trade Review
    • /
    • v.47 no.4
    • /
    • pp.293-309
    • /
    • 2022
  • The purpose of this paper is to analyze the import and export volume of Jeollabuk-do to establish a plan to activiation Saemangeum New Port. To this end, this study utilized the HHI(Herfindahl-Hirschman Index), LQ(Location Quotient) analysis using the annual data set from the Korea Trade Statistics Promotion Institution between 2015 to 2020. As a result, it has been confirmed that the degree of export volume concentration (HHI (Herfindahl-Hirschman Index)) in Jeollabuk-do has been increasing over the past 5 years. According to results of LQ(Location Quotient) analysis, Brazil had the highest index in the case of exporting countries, and Meat, edible meat offal (HS 2) had the highest index in the case of export items. This paper is meaningful in analyzing the export structure using import and export volumes and proposing a plan to improve the competitiveness of Saemangeum New Port.

An Exploratory Study on Donor Location Strategies in Data Fusion

  • Kim, Jonathan S.;Cho, Sung-Bin
    • Management Science and Financial Engineering
    • /
    • v.14 no.2
    • /
    • pp.1-12
    • /
    • 2008
  • This study explores several donor location strategies and discusses experiment results, which contributes to the saving of time and effort required in designing data fusion processes. In particular, three concepts are introduced. The Mahalanobis distance is applied to locate the nearest neighbors more effectively; which incorporates the covariance structure of attributes. The ideal point helps reduce the dimensionality problem that arises in conjoint-type experiments. The correspondence analysis is used to derive the coordinates from non-metric attributes. The Monte Carlo simulation results show that the proposed donor location strategies provide better fusion performance, compared to the currently-in-use methods.

Thermoacoustic Analysis Considering Flame Location in a Gas Turbine Combustor (가스터빈 연소기에서 화염의 위치를 고려한 열음향 해석)

  • Kim, Daesik;Kim, Sa Ryang;Kim, Kyu Tae
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • Authors' previous works on thermoacoustic(TA) model development showed good results in predicting combustion instability characteristics in a gas turbine combustor. However, they also suggested there were some limitations in growth rate estimation, which might be related with over-simplification of flame structure. As a first trial for improving the model accuracy, the current paper introduces the modified TA model considering the actual flame location in the combustor. The combustor is divided into the unburned and the burned area before and after the flame location, and then acoustic equations are re-organized. The modified TA model results show a better accuracy in predicting the growth rate of instabilities comparing with the previous results. However, obtained results still overestimate the conditions where the combustor goes unstable. Further researches considering heat release distribution through flames are required.

THE APPLICATION OF GIS FOR EFFECTIVE DISTRIBUTION OF THE EMERGENCY MEDICAL SERVICE AREA

  • Yang Byung-Yun;Hwang Chul-Sue
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.61-64
    • /
    • 2005
  • The purpose of this paper is to take a closer look at an area having shorted emergence facilities and to determine optional candidate sites instead of vulnerable area by using GIS spatial analysis. Newly determined new candidate is performed by concerning spatial efficiency and spatial equity for a public service. It was determined through using the analyzing of the physical accessibility measure, the Location-Allocation, sort of classic model in spatial statistics and general network analysis. The area of this research has been used in administrative boundary of Young-Dong in Gangneung including 13 emergency, medical hospitals, 46 fire-stations and sub-fire stations. In general terms, what all this show is that the way we are approached for geographical view from using GIS spatial analyzing technique of determined location and allocation problem by the social, economical, political factor and simple administrative discrimination at the meantime. At the same time, with problem occurred in the space it is possible to make an Effective proposal or means, policy, decision for new candidate location-allocation suggesting optimum model.

  • PDF

Fault Location Estimation for High Impedance Fault using Wavelet Transform (Wavelet 변환을 이용한 고저항 지락사고 고장점 추정)

  • Kim, Hyun;Kim, Chul-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.369-373
    • /
    • 2000
  • High impedance fault(HIF) is defined as a fault that the general overcurrent relay can not detect or interrupt. Especially when HIF occurs in residential areas, energized high voltage conductor results in fire hazard, equipment damage or personal threat. This paper proposes a fault location estimation algorithm for high impedance fault using wavelet transform. The algorithm is based on the wavelet analysis of the fault voltage and current signals. The performance of the proposed algorithm is tested on a typical 154kV korean transmission line system under various fault conditions. From the tests presented in this paper it can be concluded that a fault location estimation algorithm using wavelet transform can precisely calculate the fault point for HIF.

  • PDF

Application of the Determination Method of Monitoring Location in Real Water Distribution System (실제 상수관망에 대한 모니터링 지점선정방법의 적용)

  • Park, Yong-Gyun;Jung, Sung-Gyun;Kwon, Hyuk-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.6
    • /
    • pp.617-623
    • /
    • 2015
  • In this study, determination methods of monitoring location in water distribution system were suggested and applied to real test bed. Small block of Gwangtan water distribution system is consisted of 582 pipes, 564 junctions, 1 reservoir, and 1 pump station. Small block of Ho Chi Minh water distribution system is consisted of 162 pipes, 148 junctions, and 1 reservoir. Two small block water distribution systems were analyzed by pressure contribution analysis method to determine the optimum monitoring locations. The pressure change was estimated at each junctions by the additional demand at a junction. From the results, the optimum monitoring location can be determined by rank of pressure contribution index at each junctions due to demand change at a junction.