• 제목/요약/키워드: local temperature distribution

검색결과 328건 처리시간 0.025초

GIS 기법을 이용한 대기온도 변화 분포 분석 (Analysis of Air Temperature Change Distribution that Using GIS technique)

  • 정규용;강인준;김수겸;주홍식
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.395-397
    • /
    • 2010
  • AWS that exist in Pusan is watching local meteorological phenomena established in place that the weather observatory does not exist by real time, and is used usefully to early input data of numerical weather forecasting model. I wished to display downtown of Pusan and air temperature change of peripheral area using this AWS data. Analyzed volatility using AWS observation data for 5 years to recognize air temperature change of Pusan area through data about temperature among them. Drew air temperature distribution chart by season of recapitulative Pusan area applying IDW linear interpolation with this.

  • PDF

LIF 및 CLSM을 결합한 미소 간극 내 유체의 단면 온도 분포 측정 기법 (Measurement of Cross-sectional Temperature Distribution in Micro-scale Gap Fluid Using LIF Technique in Combination with CLSM)

  • 정동운;이상용
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.834-841
    • /
    • 2006
  • In the present wort the Laser-induced Fluorescence (LIF) technique and Confocal Laser Scanning Microscopy (CLSM) have been combined to measure the temperature distribution across a micro-scale liquid layer as a direct and non-invasive method. Only the fluorescent light emitted from a very thin volume around a focal plane can be selectively detected, and it enables us to measure the liquid temperatures even at the close vicinity of the walls. As an experimental verification, a test section consists of two flat plates (for heating and cooling, respectively) separated by about 240 microns was made, and the methanol mixed with a temperature-sensitive dye, Rhodamine B, was filled in the gap between them. The measured temperature distribution across the gap showed good linearity, which is a typical characteristic of conduction heat transfer through a thin liquid layer. In result, the CLSM-LIF technique proposed in the present study was found to be a promising method to measure the local temperatures in the liquid flow field in microfluidic devices.

입자온도 분포를 고려한 탄소입자와 산소에서의 이상폭발현상에 관한 연구 (On the two phase detonation in carbon laden oxygen : taking into account of inner particle temperature distribution)

  • 승성표;백승욱
    • 대한기계학회논문집
    • /
    • 제12권5호
    • /
    • pp.1104-1112
    • /
    • 1988
  • 본 연구에서는 고체연소미립자로써 탄소입자와 산화제로써 순수 산소를 사용 하였으며, 매우 높은 대류 열 전달 상태에서 탄소입자 표면의 대류 열저항과 고체 내 부의 전도 열 저항에 의하여 발생하는 탄소입자 내부의 온도구배를 고려하여 탄소입자 와 순수 산소의 혼합물에 있어서 이상 폭발현상을 수치적으로 연구하였다.

GRID/GIS 및 RS 자료를 이용한 에너지 평형 모형으로부터의 국지적 지표 온도 산출 (Estimation of Local Surface Temperature from EBM with the Use of GRID/GIS and Remote Sensed data)

  • 신선희;하경자;김재환;오현미;조명희
    • 대한원격탐사학회지
    • /
    • 제20권2호
    • /
    • pp.103-116
    • /
    • 2004
  • 지표 온도를 산출하는 중규모 대기 모형은 일반적으로 태양 복사의 직달 일사량에 대하여 경사진 지형의 효과를 고려하지 않는다. 이는 실제 태양 복사량의 국지적 차이를 나타내지 못하며, 그 결과 국지적인 지표 온도에서의 큰 오차를 가져온다. 따라서 지형의 기하학적 특성뿐만 아니라 지표의 식생 특성을 고려함으로써, 정확한 국지적 지표 온도를 나타내고자 하였다. 본 연구의 목적은 GIS의 그리드 모형을 적용한 에너지 균형 모형(EBM)을 사용하여 진단적으로 지역적 지표 온도를 산출하는 것이다. 본 연구에서, 한반도 남부 지역의 지형적 비균질성은 그리드 내의 지형 방위각과 경사각의 함수인 조도각의 항으로써 흡수된 지표 일사량 계산에 고려되었다. 또한 지표 온도 변화에 주요한 변수가 되는 지표의 식생 특성이 NDVI의 항으로 사용하였다. 지표의 경사진 지형의 효과와 식생 특성이 고려된 지표 온도의 상세한 지역적 분포가 연구 결과로써 제시되었다. 이러한 지역적 지표 온도 분포는 저층 대기에서 지형에 의한 지역 순환을 형성할 수 있으며, 실제 자연에서의 지역 순환을 더욱 잘 설명할 수 있을 것이다.

열교환기 휜에서의 서리층 두께와 서리층 표면온도의 실험 상관식 (Empirical Correlations of Frost Thickness and Frost Surface Temperature on Heat Exchanger Fin)

  • 김경민;김정수;김장현;이관수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.798-803
    • /
    • 2009
  • In this study, dimensionless correlations of frost properties (i.e. the thickness and surface temperature of frost) on heat exchanger fin with nonuniform temperature distribution are proposed from frosting experiments. We analyzed the local fin temperature distribution, frost thickness and frost surface temperature on a 2D fin; in the airflow direction and the direction perpendicular to airflow. As a result, the frost growth on the fin had a close relation with fin heat conduction. The dimensionless correlations for the average frost properties were expressed as a function of dimensionless temperature, humidity ratio, Reynolds number, and Fourier number. These correlations agreed well with experimental data with the error less than 14%.

  • PDF

내화피복 종류에 따른 각형 CFT기둥의 온도분포에 관한 실험적 연구 (An Experimental Study on the Temperature Distribution of Square CFT Columns According to the Types of Fire Protection)

  • 김해수;이치형
    • 한국강구조학회 논문집
    • /
    • 제22권6호
    • /
    • pp.523-532
    • /
    • 2010
  • 콘크리트가 충전된 각형강관기둥(이하, 각형 CFT기둥)은 높은 내화성능과 하중저항능력을 보유하고 있지만, CFT기둥의 외부에 내화피복을 함으로써 기둥의 내화성능을 향상시킬 필요가 있다. 본 연구는 내화 피복된 각형 CFT기둥의 온도분포에 대한 실험결과이다. 실험을 위하여 특수 제작된 전기로를 이용하여 축소모형 시험체의 재하가열실험을 수행하였다. 축하중을 받는 내화 피복된 각형 CFT기둥의 온도 분포 특성을 파악하기 위하여 내화피복의 종류와 두께, 강관의 두께 및 가열시간 등을 변수로 설정하였다. 실험결과 전기로의 온도에 따른 시험체별 온도분포와 콘크리트와 강재의 온도분포 특성을 파악하였다. 또한 시험체의 온도변화에 따른 축변위와 국부좌굴 등의 거동을 파악하였다.

수평평활관내의 비공비 혼합냉매의 응축에 대한 예측모델 (A Prediction Model for Condensation of Zeotropic Refrigerant Mixtures Inside a Horizontal Smooth Tube)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.262-270
    • /
    • 2001
  • This paper deals with a prediction method for the condensation of ternary refrigerant mixture inside a horizontal smooth tube. Based on some reliable assumptions, the governing equations for the local heat and mass transfer characteristics are derived, and the prediction for the condensation of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a, including R407C, is carried out. The local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, mass flux etc. are obtained for a constant wall temperature and a constant wall heat flux conditions, and the effects of the composition of HFC32/HFC125/HFC134a on heat transfer characteristics are examined. The prediction result is also compared with experimental data for condensation of ternary refrigerant mixtures. The predicted wall temperature distribution has a similar trend with experimental data but the predicted local heat transfer coefficients are 20-30% higher than the experimental data.

  • PDF

Forced Convection Boiling Heat Transfer from a Horizontal Cylinder to Subcooled Water

  • Lee, Sung-Hong;Lee, Euk-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.79-90
    • /
    • 1999
  • This investigation presents the experimental results of forced convection boiling heat transfer around a circular, electrically heated horizontal cylinder to subcooled water in cross flow. In these experiments, the following primary variables were included: heat flux, flow velocity, pressure and degree of subcooling at inlet. Local surface temperatures were measured at nine peripheral positions. Local surface temperature distributions are classified into four categories depending on the supplied heat flux. The effects of the boiling curve depending on the fluid velocity, degree of subcooling at inlet and pressure are presented.

  • PDF

An Experimental Study on Swirling Flow with Heat Transfer in the Horizontal Circular Annuli

  • Chang Tae-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.260-274
    • /
    • 2005
  • An experimental investigation was performed to study the characteristics of turbulent swirling flow in the cylindrical annuli. The swirl angle measurements were performed by flow visualization technique using smoke and dye liquid. By using the particle image velocimetry method. this study has found the time-mean velocity distribution and turbulent intensity with swirl for Re=20,000. 30.000. 50.000. and 70,000 along longitudinal sections. The results appear to be physically reasonable. Other experimental study was performed to investigate heat transfer characteristics of turbulent swirling air flow in axisymmetric annuli. The static pressure. the local air flow temperature, and the wall temperature with decaying swirl were measured by using thermocouples and the friction factor and the local Nusselt number were calculated for Re=30,000. 50,000 and 70000. The local Nusselt number was compared with that obtained from the Dittus-Boelter equation with swirl and without swirl, respectively. The results showed that the swirl enhances the heat transfer at the inlet and the outlet of the test tube.

한방기기(韓方機器)로 측정(測定)한 생리신호(生理信號)의 오행(五行) 생극제화규율적(生剋制化規律的) 해석(解析) (Analysis of the Physiological Signal Measured by Oriental Medicine Instruments in the View of the Rule of Promoting and Counteracting Relation of the Five Evolutive Phases)

  • 장경선;최정화;진천식;나창수;소철호
    • 한국한의학연구원논문집
    • /
    • 제2권1호
    • /
    • pp.84-103
    • /
    • 1996
  • The physiological signals measured by Oriental Medicine instruments have been analyzed quantitatively in the view of the rule of promoting and counteracting relation of five evolutive phases theory. We tried to reduce the physiological signals measured by EAV(Elec-tro-Acupuncture according to Voll) and IR thermography to the representation of five evelutive phases. The EAV index and local skin temperature on acupuncture points of each phases measured and normalized so that the total value of five phases became unity. We assumed that the normalized EAV index and local skin temperature mean the deficiency or excess of Qi for each phases. The state of Qi distribution for each phases were approximately agree with the diagnostic pattern of O. M. doctor. Taking account of the Qi distribution state of·or the five evolutive phases, we performed a proper needle insertion on acupuncture points to induce the distinct change of Qi for each phases. We compared the measured results with the predictions of Qi variation by the rule of pro- moting and counteracting relation over the five evolutive phases. For all cases, the variation of Qi in the own phase on which a needle insertion was performed were exactly same to the theoretical prediction and partial agreement was shown for the other four phases. The same analysis was carried to the results of skin temperature measurements at accupoints. We found that the local skin temperature at accupoints of each phases shelved a finite change by the needle insertion and the behavior- of its change were strongly correlated to the rule of promoting and counteracting relation of five evolutive phases.

  • PDF