• Title/Summary/Keyword: local resonance

Search Result 287, Processing Time 0.028 seconds

Diagnosis of Morton's Neuroma Using MR Imaging scans (지간 신경종의 자기 공명 영상을 이용한 진단)

  • Hong, Ki-Do;Ha, Sung-Sik;Sim, Jae-Cheon;Kim, Jae-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.131-134
    • /
    • 2003
  • Most interdigital neuroma can be diagnosed clinically. But, diagnostic local injection method, sonography and magnetic resonance image(MRI) have been used as secondary tests for clinical confirmation or surgery. Recently, there have been active discussions on the method of interdigital neuroma diagnosis for which sonography or MRI is used. For finding out the location or the number of interdigital neuroma particularly in non-typical clinical manifestation or surgery, MRIs, which are exellent in tissue contrast, may be quite helpful. This case had an interdigital neuroma showing non-typical manifestation. MRIs were used for clinical diagnostic confirmation and finding out the location and the number of interdigital neuroma. Thus, the validity along with literary consideration is being reported.

  • PDF

Application of NMR to Magnet Study (자성 연구에 있어서의 핵자기공명의 쓸모)

  • Lee, Soon-Chil
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.2
    • /
    • pp.68-74
    • /
    • 2010
  • Nuclear Magnetic Resonance (NMR) is a very useful tool for magnet study because it provides information on local spin environment. The valence of magnetic ions, spin canting angle, orbital state can be measured by NMR and the information on the position of the ions and the change of domains and domain walls can be obtained. The principle of operation is discussed with corresponding application examples.

Considerations on the Factors Reducing the Sound Transmission Loss of the Honeycomb Panels (허니콤재의 투과손실 저하 인자에 대한 고찰)

  • Kim, Seock-Hyun;Lee, Hyun-Woo;Kim, Jung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2185-2190
    • /
    • 2008
  • In a high speed train, multi-layered panels for floor, side wall and roof are important sound insulating part. As these multi-layered panels require high bending strength vs. weight, corrugated steels or aluminium honeycomb panel are generally used. However, with some inevitable factors, these panels show lower sound insulation performance than that of the plate with the same weight. Transmission loss(TL) often severely decreases in a particular frequency range because of the decrease of the critical frequency, occurrence of local resonance modes and cavity resonance modes, which are not shown in a plate. In this study, frequency range and cause of the TL drop are investigated on the corrugated and honeycomb panels.

  • PDF

Recent advances of 17O NMR spectroscopy

  • Lin, Yuxi;Kim, Hak Nam;Lee, Young-Ho
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.23 no.2
    • /
    • pp.56-60
    • /
    • 2019
  • Study on the structure and dynamics of molecules at the atomic level is of great significance for understanding their function and stability as well as roles for various chemico-physical and biological processes. $^{17}O$ NMR spectroscopy has appeared as an elegant technique for investigating of the physicochemical and structural properties of oxygen-containing compounds such as metal organic frameworks and nanosized oxides. This method has drawn much attention as it provides unique insights into the properties of targets based on atomistic information of local oxygen environments which is otherwise difficult to obtain using other methods. In this mini review, we introduce and discuss the recent study and developments of $^{17}O$ NMR techniques which are tailored for the investigation on the structure and dynamics of water and inorganic materials.

Solvent-localized in-situ NMR Monitoring by Intermolecular Single-quantum Coherence Study

  • Cha, Jin Wook;Park, Sunghyouk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.24 no.4
    • /
    • pp.96-103
    • /
    • 2020
  • A new NMR method to monitor solvent-localized NMR signals in the two-phase liquid system is suggested. This method based on intermolecular single-quantum coherence (iSQC). Here, we exploited the feature of the local action of distant dipolar field (DDF) effect in order to filter out specific NMR signals dissolved in different solvents. This solvent specific iSQC spectroscopy was carried out on a model two-phase liquid system (D-glucose in water/palmitic acid in chloroform), and showed solvent-localized NMR signals. We believe our approaches might be useful in metabolic analysis such as two-phase liquid extraction scheme for labile chemical species.

Free vibration analysis of chiral double-walled carbon nanotube using non-local elasticity theory

  • Rakrak, Kaddour;Zidour, Mohamed;Heireche, Houari;Bousahla, Abdelmoumen Anis;Chemi, Awda
    • Advances in nano research
    • /
    • v.4 no.1
    • /
    • pp.31-44
    • /
    • 2016
  • This article is concerned with the free vibration problem for chiral double-walled carbon nanotube (DWCNTs) modelled using the non-local elasticity theory and Euler Bernoulli beam model. According to the governing equations of non-local Euler Bernoulli beam theory and the boundary conditions, the analytical solution is derived and two branches of transverse wave propagating are obtained. The numerical results obtained provide better representations of the vibration behaviour of double-walled carbon nanotube, where the aspect ratio of the (DWCNTs), the vibrational mode number, the small-scale coefficient and chirality of double-walled carbon nanotube on the frequency ratio (${\chi}^N$) of the (DWCNTs) are significant. In this work, the numerical results obtained can be used to predict and prevent the phenomenon of resonance for the forced vibration analyses of double -walled carbon nanotubes.

Comparative Evaluation of Mn(II) Framework Substitution in MnAPSO-34 and Mn-impregnated SAPO-34 Molecular Sieves Studied by Electron Spin Resonance and Electron Spin Echo Modulation Spectroscopy

  • Gernho Back;Kim, Yanghee;Cho, Young-Soo;Lee, Yong-Ill;Lee, Chul-Wee
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.6 no.1
    • /
    • pp.20-37
    • /
    • 2002
  • MnAPSO-34 and Mn-impregnated SAPO-34(Mn-SAPO-34) sample were prepared with various manganese contents and studied by electron spin resonance(ESR) and electron spin echo modulation(ESEM). Electron spin echo modulation analysis of 0.07mo1 % Mn(relative to p) in MnAPSO-34 with adsorbed D$_{2}$O shows two deuteriums at 0.26 nm and two at 0.36 nm from Mn. This suggests that two waters hydrate an MnO$_{4}$ configuration with a D-O bond orientation for the waters as expect for a negatively charged site at low manganese content (0.1 mol%), the ESR spectra of MnAPSO-34 and MnH-SAPO-34 exhibit the same parameters(g 2.01 and A 89 G), but the spectra obtained from MnAPSO-34 samples are better resolved. The decomposition temperature of as-synthesized MnAPSO-34 were in the range of 200-600 $^{\circ}C$ of the morpholine which is 12 $^{\circ}C$ higher than that in as-synthesized MnH-SAPO-34. Infrared spectra showed that the position of a band at 3450 $cm^{-1}$ / shifted about 15 $cm^{-1}$ / toward higher energy in MnAPSO-34 versus MnH-SAPO-34. The modulation depth of the two-pulse ESE of MnAPSO-34 with adsorbed D$_{2}$O is deeper than that of MnH-SAPO-34 with adsorbed D$_{2}$O. Three-pulse ESEM of MnAPSO-34 and MnH-SAPO-34 with adsorbed deuterium oxide shows that the local environments of manganese in the hydrated samples are different, suggesting that Mn(II) is framework substituted in MnAPSO-34 since it obviously occupies an extraframework position in MnH-SAPO-34.

  • PDF

Comparative Study of Functional Magnetic Resonance Imaging by Global Scaling Analysis (Global Scaling 분석방법에 따른 기능적 자기공명영상의 비교 연구)

  • Yoo, Dong-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.26-31
    • /
    • 2006
  • Purpose : To evaluate the effect of global scaling analysis on brain activation for sensory and motor functional MR imaging study. Materials and methods : Four normal subjects without abnormal neurological history were included. Arm extension-flexion movement was used for motor function and 1KHz pure tone stimulation was used for auditory function. Functional magnetic resonance imaging was performed at 3T MRI (GE, Milwaukee, USA) using BOLD-EPI technique and SPM2 was employed for data analysis. On data analysis, the brain activation images were obtained with and without global scaling by fixing other parameters such as motion correction and realignment. Results : The difference in brain activation between no scaling and global scaling was not large in case of right upper extremity movement (p<0.000001). For auditory test, brain activation with global scaling showed larger activation than that of without global scaling (p<0.05). Conclusion : A caution must be taken into account when analyzing functional imaging data with global scaling especially for functional study of small local BOLD signal change.

  • PDF

Compact MIMO Antenna with Wide-Band Isolation and Ground Mode Resonance for Smart Glasses (그라운드 모드의 공진을 이용한 광대역 격리도를 가지는 스마트 안경용 소형 MIMO 안테나)

  • Ryu, Jongin;Kim, Hyeongdong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.817-820
    • /
    • 2018
  • In this letter, a compact multiple-input multiple-output(MIMO) antenna design for a 2.4 GHz wireless local area network(WLAN) band is proposed for use in smart glasses. To miniaturize the MIMO antenna system, a ground plane is employed within the antenna and a T-shaped ground is proposed. To achieve wideband isolation, dual resonance is formed by the ground mode. One resonance is created by the T-shaped ground and the second resonance is created by adding a slot and a capacitor between the two feed lines. The measurements show that the reflection coefficient characteristic was less than -5.1 dB, whereas the isolation obtained was less than -20 dB. The diversity performance was evaluated using the measured two-dimensional radiation patterns, and the envelope correlation coefficient(ECC) values achieved in the target band(2.4~2.5 GHz) were less than 0.1.

Clinical Utility of Liver Stiffness Measurements on Magnetic Resonance Elastrography in Patients with Hepatocellular Carcinoma Treated with Radiofrequency Ablation

  • Kim, Ji Eun;Lee, Jeong Min;Lee, Dong Ho;Chang, Won;Yoon, Jeong Hee;Han, Joon Goo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.231-240
    • /
    • 2016
  • Purpose: To determine whether liver stiffness (LS) measured by magnetic resonance elastography (MRE) can predict the outcome of radiofrequency ablation (RFA) in hepatocellular carcinoma (HCC) patients. Materials and Methods: A total of 107 patients with Child-Pugh class A liver function who were treated with RFA for single HCC and who had undergone a gradient-echo MRE within 6 months before RFA were included. We evaluated the relationship between the LS values and the ablation volume, local tumor progression (LTP), and intrahepatic distant recurrence (IDR). We also constructed receiver operating characteristic (ROC) curves to examine the role of LS in predicting liver function deterioration, which was defined as an increase of Child-Pugh score by one point or more at 1 year after RFA. Results: There was no significant correlation between LS and ablation volume, and neither time to LTP nor IDR was associated with LS. Among the 66 patients who did not have recurrence 1 year after RFA, 5 patients (7.6%) developed liver function deterioration. A high LS value was significantly associated with development of liver function deterioration after RFA and the area under the ROC curve was 0.764 (95% CI 0.598-0.929, P = 0.003). Conclusion: LS measured by MRE could not predict ablation volume and tumor recurrence. However, high LS values were significantly associated with development of liver function deterioration.