• Title/Summary/Keyword: local average

Search Result 1,899, Processing Time 0.034 seconds

Effects of different wind deflectors on wind loads for extra-large cooling towers

  • Ke, S.T.;Zhu, P.;Ge, Y.J.
    • Wind and Structures
    • /
    • v.28 no.5
    • /
    • pp.299-313
    • /
    • 2019
  • In order to examine the effects of different wind deflectors on the wind load distribution characteristics of extra-large cooling towers, a comparative study of the distribution characteristics of wind pressures on the surface of three large cooling towers with typical wind deflectors and one tower without wind deflector was conducted using wind tunnel tests. These characteristics include aerodynamic parameters such as mean wind pressures, fluctuating wind pressures, peak factors, correlation coefficients, extreme wind pressures, drag coefficients and vorticity distribution. Then distribution regularities of different wind deflectors on global and local wind pressure of extra-large cooling towers was extracted, and finally the fitting formula of extreme wind pressure of the cooling towers with different wind deflectors was provided. The results showed that the large eddy simulation (LES) method used in this article could be used to accurately simulate wind loads of such extra-large cooling towers. The three typical wind deflectors could effectively reduce the average wind pressure of the negative pressure extreme regions in the central part of the tower, and were also effective in reducing the root of the variance of the fluctuating wind pressure in the upper-middle part of the windward side of the tower, with the curved air deflector showing particularly. All the different wind deflectors effectively reduced the wind pressure extremes of the middle and lower regions of the windward side of the tower and of the negative pressure extremes region, with the best effect occurring in the curved wind deflector. After the wind deflectors were installed the drag coefficient values of each layer of the middle and lower parts of the tower were significantly higher than that without wind deflector, but the effect on the drag coefficients of layers above the throat was weak. The peak factors for the windward side, the side and leeward side of the extra-large cooling towers with different wind deflectors were set as 3.29, 3.41 and 3.50, respectively.

Comparison of Health Promotion Behaviors and Safety Consciousness of Elderly Women Living Alone in Rural Areas and Elderly Women in Group Homes (농촌 지역 재가여성 독거노인과 공동거주시설 여성노인의 건강증진행위와 안전의식 비교)

  • Seok, Min-Yuk;Kang, Young-Sil;Ha, Yeongmi
    • Journal of Korean Academy of Rural Health Nursing
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Purpose: This study was aimed to compare health promotion behaviors and safety consciousness for elderly women living alone in rural areas and elderly women in group homes, and then provide information for the development of safety awareness programs for elderly. Methods: The participants were 120 elderly women living alone in rural areas aged 65 or older and 120 elderly women living in group homes. The data collection was conducted during November 2020, and the collected data used the SPSS/WIN 25.0 program to verify frequency, percentage, average, standard deviation, and independent t test. Results: There were significant differences of health promotion behaviors between elderly women living alone and elderly women in group homes (t=15.77, p<.001). In addition, there were significant differences of safety consciousness between elderly women living alone and elderly women in group homes (t=21.42, p<.001). Conclusion: Since the safety consciousness and health promotion behaviors of the elderly in group homes are significantly higher than that of the elderly living alone, various programs should be developed to improve the safety consciousness and health promotion behaviors in the elderly living alone. Based on local government' acts, continuous support and attention is needed that elderly women in group homes can maintain a healthy life.

A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic

  • Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.143-149
    • /
    • 2018
  • The purpose of this study is to propose a management method to maintain the pleasant indoor air quality of the dental clinic by measuring and analyzing the indoor air quality of the dental clinic. The measurement was conducted in two rooms, a lobby where many residents stay in the reception room for waiting for medical treatment, and a VIP room where treatment activities are mainly performed. Measurement items are Temperature, Humidity, $CO_2$, CO, $NO_2$, $CH_2O$, VOC, $PM_{10}$ and measurement were taken on April 27, 2018. As a result of analyzing the temperature and humidity of the dental clinic, it was analyzed that the average indoor temperature was maintained at $25^{\circ}C$ and the humidity was kept at around 50%, maintaining proper indoor temperature and humidity environment. $CO_2$ was 855ppm in the VIP Room, which satisfied the maintenance standard. In the case of the lobby, it was analyzed to be 1,160ppm, which exceeded the maintenance standard and it is judged that the carbon dioxide generated by the respiration of the people staying in the lobby is the main reason. The mean concentration of formaldehyde in the VIP room was analyzed as $436{\mu}g/m^3$, exceeding the maintenance standard, and $2,100{\mu}g/m^3$ for the VOC exceeded the recommended standard. It was analyzed that the concentration was relatively higher due to the use of disinfectant and other drugs. The mean concentration of PM-10 in the lobby was analyzed as $65{\mu}g/m^3$ and it was analyzed that it satisfied the maintenance standard. To maintain a pleasant indoor air quality in a dental clinic it is necessary to minimize the effects of formaldehyde, VOC, $CO_2$ in the VIP rooms and lobby. For this purpose, the entire ventilation system and air purification system of the dental clinic should be installed. In case of the VIP room, local exhaust ventilation should be installed and workers should wear personal protective equipment.

Analyses of the Meteorological Characteristics over South Korea for Wind Power Applications Using KMAPP (고해상도 규모상세화 수치자료 산출체계를 이용한 남한의 풍력기상자원 특성 분석)

  • Yun, Jinah;Kim, Yeon-Hee;Choi, Hee-Wook
    • Atmosphere
    • /
    • v.31 no.1
    • /
    • pp.1-15
    • /
    • 2021
  • High-resolution wind resources maps (maps, here after) with spatial and temporal resolutions of 100 m and 3-hours, respectively, over South Korea have been produced and evaluated for the period from July 2016 to June 2017 using Korea Meteorological Administration (KMA) Post Processing (KMAPP). Evaluation of the 10 m- and 80 m-level wind speed in the new maps (KMAPP-Wind) and the 1.5 km-resolution KMA NWP model, Local Data Assimilation and Prediction System (LDAPS), shows that the new high-resolution maps improves of the LDAPS winds in estimating the 10m wind speed as the new data reduces the mean bias (MBE) and root-mean-square error (RMSE) by 33.3% and 14.3%, respectively. In particular, the result of evaluation of the wind at 80 m which is directly related with power turbine shows that the new maps has significantly smaller error compared to the LDAPS wind. Analyses of the new maps for the seasonal average, maximum wind speed, and the prevailing wind direction shows that the wind resources over South Korea are most abundant during winter, and that the prevailing wind direction is strongly affected by synoptic weather systems except over mountainous regions. Wind speed generally increases with altitude and the proximity to the coast. In conclusion, the evaluation results show that the new maps provides significantly more accurate wind speeds than the lower resolution NWP model output, especially over complex terrains, coastal areas, and the Jeju island where wind-energy resources are most abundant.

Estimating Location in Real-world of a Observer for Adaptive Parallax Barrier (적응적 패럴랙스 베리어를 위한 사용자 위치 추적 방법)

  • Kang, Seok-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1492-1499
    • /
    • 2019
  • This paper propose how to track the position of the observer to control the viewing zone using an adaptive parallax barrier. The pose is estimated using a Constrained Local Model based on the shape model and Landmark for robust eye-distance measurement in the face pose. Camera's correlation converts distance and horizontal location to centimeter. The pixel pitch of the adaptive parallax barrier is adjusted according to the position of the observer's eyes, and the barrier is moved to adjust the viewing area. This paper propose a method for tracking the observer in the range of 60cm to 490cm, and measure the error, measurable range, and fps according to the resolution of the camera image. As a result, the observer can be measured within the absolute error range of 3.1642cm on average, and it was able to measure about 278cm at 320×240, about 488cm at 640×480, and about 493cm at 1280×960 depending on the resolution of the image.

Opinions of dental hygienists on the advanced dental hygienist system (전문치과위생사제도에 대한 견해)

  • Lee, Sun-Mi;Kim, Chang-Hee;Sim, Seon-Ju;Kim, Hyeong-Mi;Lee, Keun-Yoo;Yoo, Myung-Sook;Won, YoungSoon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.21 no.4
    • /
    • pp.413-425
    • /
    • 2021
  • Objectives: This study aimed to provide basic data to lay the groundwork for the introduction of an advanced dental hygienist system by sampling dental hygienists' views about the system. Methods: A nationwide questionnaire survey was conducted targeting 857 dental hygienists working at dental hospitals and clinics, local health institutions, and educational institutions. The collected data were analyzed using frequency analysis, t-test, one-way analysis of variance (ANOVA) (Duncan as post-analysis), and crossover analysis. Results: The average interest level in the advanced dental hygienist system was 3.83±0.95 points. The necessity by field was confirmed to be the highest during dental hygiene for the elderly and persons with disabilities. The working experience necessary for becoming a specialized dental hygienist is 5.56±2.99 (years). The education period necessary for becoming a specialized dental hygienist is 77.30±77.61 (hours). The work authority level for an advanced dental hygienist was indicated to be 50 respondents (5.8%), who said they required direct guidance from a dentist, 313 respondents (48.2%) who said they needed indirect guidance from a dentist, 200 respondents (23.3%) who said OK when given an advanced dental hygienist's separate judgment, 194 respondents (22.6%), who said that the authority must be varied depending on the work. Conclusions: The interest and need of the advanced dental hygienist system were proven to be high and are expected to be applied to basic data for the introduction and settlement of the system.

Spatial and temporal dynamic of land-cover/land-use and carbon stocks in Eastern Cameroon: a case study of the teaching and research forest of the University of Dschang

  • Temgoua, Lucie Felicite;Solefack, Marie Caroline Momo;Voufo, Vianny Nguimdo;Belibi, Chretien Tagne;Tanougong, Armand
    • Forest Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.181-191
    • /
    • 2018
  • This study was carried out in the teaching and research forest of the University of Dschang in Belabo, with the aim of analysing land-cover and land-use changes as well as carbon stocks dynamic. The databases used are composed of three Landsat satellite images (5TM of 1984, 7ETM + of 2000 and 8OLI of 2016), enhanced by field missions. Satellite images were processed using ENVI and ArcGIS software. Interview, focus group discussion methods and participatory mapping were used to identify the activities carried out by the local population. An inventory design consisting of four transects was used to measure dendrometric parameters and to identify land-use types. An estimation of carbon stocks in aboveground and underground woody biomass was made using allometric models based on non-destructive method. Dynamic of land-cover showed that the average annual rate of deforestation is 0.48%. The main activities at the base of this change are agriculture, house built-up and logging. Seven types of land-use were identified; adult secondary forests (64.10%), young secondary forests (7.54%), wetlands (7.39%), fallows (3.63%), savannahs (9.59%), cocoa farms (4.28%) and mixed crop farms (3.47%). Adult secondary forests had the highest amount of carbon ($250.75\;t\;C\;ha^{-1}$). This value has decreased by more than 60% for mixed crop farms ($94.67\;t\;C\;ha^{-1}$), showing the impact of agricultural activities on both forest cover and carbon stocks. Agroforestry systems that allow conservation and introduction of woody species should be encouraged as part of a participatory management strategy of this forest.

Usefulness of full-thickness skin grafting from the infraclavicular area for facial reconstruction

  • Kang, Jae Kyoung;Lee, Jae Seong;Yun, Byung Min;Shin, Myoung Soo
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.6
    • /
    • pp.357-362
    • /
    • 2020
  • Background: Full-thickness skin grafts (FTSGs) have been widely used after facial skin cancer resection, for correcting defects that are too wide to be reconstructed using a local flap or if structural deformation is expected. The preauricular, posterior auricular, supraclavicular, conchal bowl, nasolabial fold, and upper eyelid skin areas are known as the main donor sites for facial FTSG. Herein, we aimed to describe the effectiveness of using infraclavicular skin as the donor site for specific cases. Methods: We performed FTSG using the infraclavicular skin as the donor site in older Asian adults following skin cancer resection. Outcomes were observed for > 6 months postoperatively. The Manchester Scar Scale was used for an objective evaluation of satisfaction following surgery and scarring. Results: We analyzed the data of 17 patients. During follow-up, the donor and recipient sites of all patients healed without complications. Upon evaluation, the average Manchester Scar Scale scores for the recipient and donor sites were 7.4 points and 5.7 points, respectively. Conclusion: In general, conventional donor sites, such as the preauricular, posterior auricular, and supraclavicular sites, are widely used for facial FTSG because they achieve good cosmetic results. However, the infraclavicular skin may be a useful donor for facial FTSG in cases where the duration of time spent under anesthesia must be minimized due to a patient's advanced age or underlying health conditions, or when the recipient site is relatively thick area, such as the nose, forehead, or cheek.

Effective criterion for evaluating registration accuracy (정합 정밀도 판단을 위한 효과적인 기준)

  • Lim, Sukhyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.5
    • /
    • pp.652-658
    • /
    • 2021
  • When acquiring a point cloud using a 3D scanner, a registration process of making the acquired data based on each local coordinate into one data with a unified world coordinate system is required. Its process is difficult to obtain a satisfactory result with only one execution, and it is repeated several times to increase the registration precision. The criterion for determining the registration accuracy is an important factor. The previous methods for determining the accuracy of registration have a limitation in that the judgment may be ambiguous in some cases, and different results may be produced each time depending on the characteristics of the point cloud. Therefore, to calculate the accuracy of registration more precisely, I propose a method using the average distance value of the point group for the entire points rather than the corresponding points used in the registration. When this method is used, it is possible to determine the registration accuracy more reliably than the conventional methods.

Factors Related to Smoking Recurrence within Six-months Smoking Cessation among Employees in Enterprises with Smaller than 300 Workers (300인 미만 사업장근로자의 6개월 이내 재흡연 관련요인)

  • Jin, Byung Jun;Kim, Chul-Woung;Lee, Seung Eun;Im, Hyo-Bin;Lee, Tae-Yong
    • Research in Community and Public Health Nursing
    • /
    • v.32 no.1
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: The purpose of this study is to identify factors associated with smoking relapse within six months after quit attempts among workers in small and medium-sized enterprises in South Korea. Methods: The analysis was conducted for a total of 194 people who attempted to quit smoking by applying for a smoking cessation support service at the Regional Tobacco Control Center. The data used in the study were extracted from the Smoking Cessation Service Integrated Information System. Kaplan-Meier estimator and Cox proportional hazards regression model were used to identify variables associated with smoking relapse within six months' time period. Results: Smoking relapse rate within six months was 66.0%, and variables associated with relapse included the cases such as carbon monoxide (CO) at the time of registration (HR: 2.15, 95% CI: 1.10~4.22 for CO ≥20 ppm or more vs.CO <10 ppm), the average number of cigarettes smoked per day (HR: 1.04, 95% CI: 1.00~1.07), and the number of counseling(HR: 0.60, 95% CI: 0.54~0.67). Conclusion: Smoking characteristics and counseling showed one of the strongest correlations with relapse within six months. This implies that it is necessary to understand the smoking characteristics and patterns of workers and to provide continuous smoking cessation counseling tailored to individual characteristics for effective smoking relapse prevention.