• Title/Summary/Keyword: loading performance

Search Result 2,637, Processing Time 0.26 seconds

Analysis of Performance Tests and Friction Characteristics of a Friction Type Isolator Considering Train Load Conditions (열차 하중조건을 고려한 마찰형 방진장치 성능시험 및 마찰특성 분석)

  • Koh, Yong-Sung;Lee, Chan-Young;Ji, Yong-Soo;Kim, Jae-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.694-702
    • /
    • 2017
  • In the case of an elevated railway station, structure borne noise and vibration due to structural limitations allow the load and vibration from railway vehicles to be directly transmitted to the station structure, resulting in an increase in the number of civil complaints from customers and staff of the station. The floating slab track system, which is well known as one of the solutions for reducing the noise and vibration from elevated railway stations, usually contains rubber mounts or rubber pads under the railway slab which act as a damper. These types of device have the disadvantage that is difficult to predetermine the exact stiffness and damping ratio under the nonlinear loads resulting from train services. In this study, an isolator with a friction type of wedge is introduced, which can be applied to floating slab track systems and to be designed with precisely the required stiffness. Furthermore, a comparative analysis of the stiffness between the designed and experimental values is carried out, while the damping ratio, which is closely related to the friction wedge blocks, is deduced according to the train load condition. The performance tests of the isolator were conducted in accordance with the DIN 45673-7 standard which includes both static and dynamic load tests. The load conditions for the performance tests are designed to conform to the DIN standard related to the weight of the train and rail track, in order to perform vertical and horizontal load tests, so as to ensure the secure structural safety of the railway. Also, by checking the change aspect of the friction coefficients of the friction elements according to the loading rate, the vibration reduction performance of the friction type isolator with variable loading rate conditions is examined.

Seismic damage evaluation of steel reinforced recycled concrete filled circular steel tube composite columns

  • Hui, Ma;Xiyang, Liu;Yunchong, Chen;Yanli, Zhao
    • Earthquakes and Structures
    • /
    • v.23 no.5
    • /
    • pp.445-462
    • /
    • 2022
  • To investigate and evaluate the seismic damage behaviors of steel reinforced recycled concrete (SRRC) filled circular steel tube composite columns, in this study, the cyclic loading tests of 11 composite columns was carried out by using the load-displacement joint control method. The seismic damage process, hysteretic curves and performance indexes of composite columns were observed and obtained. The effects of replacement rates of recycled coarse aggregate (RCA), diameter thickness ratio, axial compression ratio, profile steel ratio and section form of profile steel on the seismic damage behaviors of composite columns were also analyzed in detail. The results show that the failure model of columns is a typical bending failure under the combined action of horizontal loads and vertical loads, and the columns have good energy dissipation capacity and ductility. In addition, the replacement rates of RCA have a certain adverse effect on the seismic bearing capacity, energy consumption and ductility of columns. The seismic damage characteristics of composite columns are revealed according to the failure modes and hysteretic curves. A modified Park-Ang seismic damage model based on the maximum displacement and cumulative energy consumption was proposed, which can consider the adverse effect of RAC on the seismic damage of columns. On this basis, the performance levels of composite columns are divided into five categories, The interlayer displacement angle and damage index are used as the damage quantitative indicators of composite columns, and the displacement angle limits of composite columns at different performance levels under 80% assurance rate are calculated as 1/105, 1/85, 1/65, 1/28, and 1/25 respectively. On this basis, the damage index limits corresponding to each performance level are calculated as 0.045, 0.1, 0.48, 0.8, and 1.0 respectively. Finally, the corresponding relations among the performance levels, damage degrees, interlayer displacement angles and damage indexes of composite columns are established. The conclusions can provide reference for the seismic design of SRRC filled circular steel tube composite columns, it fills the vacancy in the research on seismic damage of steel reinforced recycled concrete (SRRC) filled circular steel tube composite columns.

A Design and Performance Evaluation of Semi-active MR Damper for the Smart Control of Construction Structures (건설구조물의 스마트 제어를 위한 준능동 MR 감쇠기의 설계 및 성능평가)

  • Heo, Gwang-Hee;Jeon, Joon-Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.165-171
    • /
    • 2009
  • This research developed two semi-active MR dampers whose gaps in the orifice area were different from each other, and evaluated their damping performance by loading tests. The Damping performance of MR dampers characteristically depends on various factors like their material and mechanical ones, but most importantly on the size of gap in the orifice area. For this research, we designed the orifice gaps of two dampers as each 1.0mm and 2.0mm, both with the 80mm outer diameter of the orifice. We also designed two loading test sets with different input currents, and acquired different control ability from them. The acquired test results were analyzed and evaluated with their maximum and minimum damping force and also their dynamic range from the force-displacement hysteresis loops and the force-input current relationship curve. This research clearly proved how the damping performance of control devices depends on the gap effect, and also presented a possibility that the two dampers developed in this research could be used for the smart control of construction structures by effectively adapting the input current and the number of coil turns.

Bending analysis of nano-Fe2O3 reinforced concrete slabs exposed to temperature fields and supported by viscoelastic foundation

  • Zouaoui R. Harrat;Mohammed Chatbi;Baghdad Krour;Sofiane Amziane;Mohamed Bachir Bouiadjra;Marijana Hadzima-Nyarko;Dorin Radu;Ercan Isik
    • Advances in concrete construction
    • /
    • v.17 no.2
    • /
    • pp.111-126
    • /
    • 2024
  • During the clinkering stages of cement production, the chemical composition of fine raw materials such as limestone and clay, which include iron oxide (Fe2O3), silicon dioxide (SiO2) and aluminum oxide (Al2O3), significantly influences the quality of the final product. Specifically, the chemical interaction of Fe2O3 with CaO, SiO2 and Al2O3 during clinkerisation plays a key role in determining the chemical reactivity and overall quality of the final cement, shaping the properties of the concrete produced. As an extension, this study aims to investigate the physical effects of incorporating nanosized Fe2O3 particles as fillers in concrete matrices, and their impact on concrete structures, namely slabs. To accurately model the reinforced concrete (RC) slabs, a refined trigonometric shear deformation theory (RTSDT) is used. Additionally, the stochastic Eshelby's homogenization approach is employed to determine the thermoelastic properties of nano-Fe2O3 infused concrete slabs. To ensure comprehensive coverage in the study, the RC slabs undergo various mechanical loads and are exposed to temperature fields to assess their thermo-mechanical performance. Furthermore, the slabs are assumed to rest on a three-parameter viscoelastic foundation, comprising the Winkler elastic springs, Pasternak shear layer and a damping parameter. The equilibrium governing equations of the system are derived using the principle of virtual work and subsequently solved using Navier's technique. The findings indicate that while ferric oxide nanoparticles enhance the mechanical properties of concrete against mechanical loading, they have less favorable effects on its performance against thermal exposure. However, the viscoelastic foundation contributes to mitigating these effects, improving the concrete's overall performance in both scenarios. These results highlight the trade-offs between mechanical and thermal performance when using Fe2O3 nanoparticles in concrete and underscore the importance of optimizing nanoparticle content and loading conditions to improve the structural performance of concrete structures.

The effects of construction practices on the seismic performance of RC frames with masonry infills

  • Lagaros, Nikos D.;Geraki, Martha A.
    • Structural Engineering and Mechanics
    • /
    • v.28 no.1
    • /
    • pp.69-88
    • /
    • 2008
  • A number of construction practices, implemented during the design process of a reinforced concrete (RC) structural system, may have significant consequences on the behaviour of the structural system in the case of earthquake loading. Although a number of provisions are imposed by the contemporary Greek national design codes for the seismic design of RC structures, in order to reduce the consequences, the influence of the construction practices on the seismic behaviour of the structural system remains significant. The objective of this work is to perform a comparative study in order to examine the influence of three, often encountered, construction practices namely weak ground storey, short and floating columns and two combinations on the seismic performance of the structural system with respect to the structural capacity and the maximum interstorey drifts in three earthquake hazard levels.

Experimental investigation of low-velocity impact characteristics of steel-concrete-steel sandwich beams

  • Sohel, K.M.A.;Richard Liew, J.Y.;Alwis, W.A.M.;Paramasivam, P.
    • Steel and Composite Structures
    • /
    • v.3 no.4
    • /
    • pp.289-306
    • /
    • 2003
  • A series of tests was conducted to study the behaviour of steel-composite sandwich beams under low velocity hard impact. Damage characteristic and performance of sandwich beams with different spacing of shear connector were evaluated under impact loading. Thin steel plates were used as top and bottom skins of the sandwich beams and plain concrete was used as the core material. Shear connectors were provided by welding of angle sections on steel plates. The sandwich beams were impacted at their midpoint by a hemi-spherical nose shaped projectile dropped from various heights. Strains on steel plates were measured to study the effects of impact velocity or impact momentum on the performance of sandwich beams. Spacing of shear connectors is found to have significant effects on the impact response of the beams.

Reliability of metal films on flexible polymer substrate during cyclic bending deformations

  • Kim, Byeong-Jun;Jeong, Seong-Hun;Kim, Do-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.244.1-244.1
    • /
    • 2016
  • Recently, the technology for flexible electronics such as flexible smart phone, foldable displays, and bendable battery is under active development. With approaching the real commercialization of flexible electronics, the electrical and mechanical reliability of flexible electronics have become significantly important because they will be used under various mechanical deformations such as bending, twisting, stretching, and so on. These mechanical deformations result in performance degradation of electronic devices due to several mechanical problems such as cracking, delamination, and fatigue. Therefore, the understanding of relationship between mechanical loading and electrical performance is one of the most critical issues in flexible electronics for expecting the lifetime of products. Here, we have investigated the effect of monotonic tensile and cyclic deformations on metal interconnect to provide a guideline for improving the reliability of flexible interconnect.

  • PDF

A novel hybrid testing approach for piping systems of industrial plants

  • Bursi, Oreste S.;Abbiati, Giuseppe;Reza, Md S.
    • Smart Structures and Systems
    • /
    • v.14 no.6
    • /
    • pp.1005-1030
    • /
    • 2014
  • The need for assessing dynamic response of typical industrial piping systems subjected to seismic loading motivated the authors to apply model reduction techniques to experimental dynamic substructuring. Initially, a better insight into the dynamic response of the emulated system was provided by means of the principal component analysis. The clear understanding of reduction basis requirements paved the way for the implementation of a number of model reduction techniques aimed at extending the applicability range of the hybrid testing technique beyond its traditional scope. Therefore, several hybrid simulations were performed on a typical full-scale industrial piping system endowed with a number of critical components, like elbows, Tee joints and bolted flange joints, ranging from operational to collapse limit states. Then, the favourable performance of the L-Stable Real-Time compatible time integrator and an effective delay compensation method were also checked throughout the testing campaign. Finally, several aspects of the piping performance were commented and conclusions drawn.

FLAP DEELECTION OPTIMZATION FOR TRANSONIC CRUISE PERFORMANCE IMPROVEMENT OF SUPERSONIC TRANSPORT WING

  • Kim Hyoung-Jin;Obayashi Shigeru;Nakahashi Kazuhiro
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.32-38
    • /
    • 2000
  • Wing flap deflection angles of a supersonic transport are optimized to improve transonic cruise performance. For this end, a numerical optimization method is adopted using a three-dimensional unstructured Euler code and a discrete adjoint code. Deflection angles of ten flaps; five for leading edge and five fur railing edge, are employed as design variables. The elliptic equation method is adopted for the interior grid modification during the design process. Interior grid sensitivities are neglected for efficiency. Also tested is the validity of the approximate gradient evaluation method for the present design problem and found that it is applicable for loading edge flap design in cases of no shock waves on the wing surface. The BFGS method is used to minimize the drag with constraints on the lift and upper surface Mach numbers. Two design examples are conducted; one is leading edge flap design, and the other is simultaneous design of leading edge and trailing edge flaps. The latter gave a smaller drag than the former by about two counts.

  • PDF

A Study on The Feliability Predication Model of Gyroscope (자이로의 신뢰성 예측모델에 관한 연구)

  • 백순흠;문홍기;김호룡
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.475-481
    • /
    • 1993
  • The objective of this study is to develope the reliability prediction model for Float Rated Integrating Gyroscope( :FRIG) at maximum loading. The equation of motion for FRIG is firstly derived to set up the reliability prediction model. To analysis reliability or all parts of the gyro is not easy due to their complicated structure. Therefore the failure parts are chosen by Failure Mode Effective Analysis (:FMEA). F.E.M is utilized to calculate loads for the selseced rotating assembly and pivot / jewel. The technical reliability is calculated by applying reliability design theory with these results and the performance reliability is sought through distribution estimation with error test data. The bulk reliability of gyroscope is sought by applying the two results. The present prediction results are compared with the accumulation time in good agreement.

  • PDF