• 제목/요약/키워드: loading offset

검색결과 61건 처리시간 0.027초

Response of a finite beam on a tensionless Pasternak foundation under symmetric and asymmetric loading

  • Coskun, Irfan;Engin, Hasan;Ozmutlu, Aydin
    • Structural Engineering and Mechanics
    • /
    • 제30권1호
    • /
    • pp.21-36
    • /
    • 2008
  • The static response of a finite beam resting on a tensionless Pasternak foundation and subjected to a concentrated vertical load is assessed in this study. The concentrated vertical load may be applied at the center of the beam, or it may be offset from the center. The tensionless character of the foundation results in the creation of lift-off regions between the beam and the foundation. An analytical/ numerical solution is obtained from the governing equations of the contact and lift-off regions to determine the extent of the contact region. Although there is no nonlinear term in the equations, the problem shows a nonlinear character since the contact region is not known in advance. Due to that nonlinearity, the essentials of the problem (the coordinates of the lift-off points) are calculated numerically using the Newton-Raphson technique. The numerical results are presented in figures to illustrate the behaviours of the free-free and pinned-pinned beams under symmetric or asymmetric loading. The figures illustrate the effects of the shear foundation parameter and the symmetric and asymmetric loading options on the variation of the contact lengths and the displacement of the beam.

임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석 (Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load)

  • 장종석;정용태;정재헌
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE PLATFORM SWITCHING

  • Kim Yang-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.727-735
    • /
    • 2005
  • Statement of problem. Platform switching in implant prosthesis has been used for esthetic and biological purpose. But there are few reports for this concept. Purpose. The purpose of this study is evaluation of platform switching in wide implant by three dimensional finite element analysis. Materials and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for Osstem implant system. Three-dimensional finite element models were developed for (1) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with wide cemented abutment, titanium alloy abutment screw, and prosthesis (2) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with regular cemented abutment, titanium alloy abutment screw and prosthesis(platform switching) was made for finite element analysis. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized to 650N, and round and flat type prostheses were loaded to 200 N. Four loading offset point (0, 2, 4, 6 mm from the center of the implants) were evaluated. Models were processed by the software programs HyperMesh and ANSA. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView were used for post processing. Results. The results from experiment were as follows; 1. von Mises stress value is increased in order of bone, abutment, implant and abutment screw. 2. von Mises stress of abutment screw is lower when platform switching. 3. von Mises stress of implant is lower when platform switching until loading offset 4 mm. 4. von Mises stress of abutment is similar between each other. 5. von Mises stress of bone is slightly higher when platform switching. Conclusion. The von Mises stress pattern of implant components is favor when platform switch ing but slightly higher in bone stress distribution than use of wide abutment. The research about stress distribution is essential for investigation of the cortical bone loss.

FWD 처짐량 기반 도로 공동 및 함몰 위험도 평가 기초 연구 (Preliminary Evaluation of Subsurface Cavity and Road Cave-in Potentials Based on FWD Deflections)

  • 김태우;윤진성;이창민;백종은;최연우
    • 한국도로학회논문집
    • /
    • 제19권5호
    • /
    • pp.59-68
    • /
    • 2017
  • PURPOSES : The objective of this study is to evaluate the potential risk level of road cave-ins due to subsurface cavities based on the deflection basin measured with falling weight deflectometer (FWD) tests. METHODS: Ground penetrating radar (GPR) tests were conducted to detect road cavities. Then FWD tests were conducted on 13 pavement test sections with and without a cavity. FWD deflections and a deflection ratio was used to evaluate the effect of geometry of the cavity and pavement for road cave-in potentials. RESULTS : FWD deflection of cavity sections measured at 60 cm or a closer offset distance to a loading center were 50% greater than more robust sections. The average deflection ratio of the cavity sections to robust sections were 1.78 for high risk level cavities, 1.51 for medium risk level cavities, and 1.16 for low risk level cavities. The relative remaining service life of pavement with a cavity evaluated with an surface curvature index (SCI) was 8.1% for the high level, 21.8% for the medium level, and 89.8% compared to pavement without a cavity. CONCLUSIONS : FWD tests can be applied to detect a subsurface cavity by comparing FWD deflections with and without a cavity measured at 60 cm or a closer offset distance to loading center. In addition, the relative remaining service life of cavity sections based on the SCI can used to evaluate road cave-in potentials.

화강풍화토에서 Scale Effect를 고려한 기초의 지지력 및 침하량 산정에 관한 연구 (A Research for Computation of Bearing Capacity and Settlement of Foundation Considering Scale Effect in Weathered-granite Layer)

  • 박용부;정형식
    • 한국지반공학회논문집
    • /
    • 제20권1호
    • /
    • pp.131-139
    • /
    • 2004
  • 지내력기초 설계와 시공을 위해 실시하는 평판재하시험 결과로부터 실제 기초지반의 지지력 및 침하량을 산정할때 scale effect를 고려해야 하는데 국내에는 scale effect 적용기준이나 관련 시험자료가 없다. 그래서, 화강풍화토 지반에서 재하판 크기별 지지력 및 침하량의 상관관계를 파악하기 위해 모형토조 및 현장 평판재하시험을 실시하였다. 토조시험은 토조내에 지층을 형성한후 함수비 조건, 다짐횟수, 습윤 단위중량, 및 재하판 직경(D15, 25cm)별로 모형토조$(2,000\times 2,000\times 1,000mm)$에서 실시하였다. 현장 재하시험은 재하판 직경$(D15, 25, 30, 40, 75\times 75, 140\times 210cm)$별로 실시하였다. 재하시험 결과분석과 수치해석을 통해 토사 및 암반지반에서 지내력 기초설계시 Scale effect를 계산하기 위한 지지력 및 침하량 산정식을 제시하였다.

국내산 낙엽송집성재의 지압특성 (Bearing Properties of Domestic Larix Glulam)

  • 김건호;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권4호
    • /
    • pp.93-101
    • /
    • 2008
  • 하중방향(섬유평행방향, 섬유직각방향)과 접합구(볼트, 드리프트 핀) 적층면방향(평행, 수직)에 따른 국내산 낙엽송집성재의 지압강도시험을 실시하였다. 지압시편은 5 ply의 집성재를 사용하였고, 접합구의 직경은 12, 16, 20 mm를 사용하였다. 시험결과는 다음과 같다. 1) 볼트와 드리프트 핀의 각 직경에 따른 평균최대지압강도는 섬유평행하중방향의 경우 비슷한 경향을 보였으며, 섬유평행하중방향의 평균최대지압강도가 섬유직교방향보다 1.50~2.31배 높게 나타났다. 평균지압강도의 경우 섬유평행하중방향시편은 직경 16 mm에서 20 mm로 증가할 때 20% 감소하였으며, 섬유직교방향은 뚜렷한 경향이 없었다. 2) 평균지압초기강성의 경우 섬유평행하중방향은 직경 16 mm일 때 가장 크게 나타났다. 드리프트 핀 접합부의 전단강도실험 시 초기강성과 평균지압초기강성은 직경이 증가할수록 비슷한 경향을 보였다. 3) 지압강도시험 시 섬유평행방향시편의 파괴형상은 직경이 작을수록 할렬파단을 보였다. 섬유직교방향의 시편은 대부분이 섬유평행방향으로 할렬파단이 일어났으며 볼트가 드리프트 핀 시편보다 더 많이 나타났다. 4) 지압강도예측식을 통해 구한 예측지압강도와 실제 5% 유사항복지압강도를 비교하였을 경우 섬유평행방향은 KBCS, NDS의 예측지압강도와 비슷하게 나타났으나, 섬유직교방향은 NDS에서 제안한 예측식이 잘 적용되는 것을 알 수 있었다.

환원황화합물의 분석과 검량기준의 선택에 따른 오차발생의 특성 (Selection of Calibration Approaches and Their Impact on the Quantification of Unknown Samples: Case Study on Reduced Sulfur Gases)

  • 조효재;홍원필;김기현
    • 한국대기환경학회지
    • /
    • 제27권2호
    • /
    • pp.133-141
    • /
    • 2011
  • In this study, different calibration approaches for reduced sulfur compounds (RSCs) were investigated by using thermal desorption coupled with gas chromatography (GC) and pulsed flame photometric detection (PFPD). To evaluate the effects of calibration procedures, gaseous standards of 4 RSCs ($H_2S$, $CH_3SH$, DMS, and DMDS) prepared at 10 ppm level were analyzed at 7 loading injection volumes (40, 60, 80, 100, 160, 240, and 320 ${\mu}L$). The results were then compared with calibration curves made with the Z (zero offset) and N (non-zero offset) method. The concentrations of unknown samples were then quantified by using R (ratio) method in which the slope values are compared between standards and samples. Secondly, in A (average) method, results obtained from a multi-point analysis of unknown samples were also averaged to extract representative values for each sample. Results of both experiments showed that analytical error of low molecular weight components (such as $H_2S$ and $CH_3SH$) was greatly expanded with the Z method. In conclusion, the combined application of N-A method was the more realistic approach to reduce biases in the quantification of RSCs.

압축과 전단 하중을 받는 인공 암석 절리의 수리적 거동에 관한 실험적 연구 (An Experimental Study for the Hydraulic Behavior of Artificial Rock Joint under Compression and Shear Loading)

  • 이희석;박연주;유광호;이희근
    • 터널과지하공간
    • /
    • 제10권1호
    • /
    • pp.45-58
    • /
    • 2000
  • 다양한 하중 조건하의 암석 절리에 대한 수리적 거동을 규명하기 위해서 수리전단 시험이 가능한 주기 전단시험 시스템을 설계, 제작하였다. 실험실에서 인공 절리 시료에 대한 압축,전단 조건하의 수리 시험을 실시하였다. 시험 전의 시료에 대한 3차원 간극 측정을 통해 절리의 간극 분포 특성을 규명하였다. 수직응력에 따른 투수계수 변화는 기존 수리 모델과 잘 일치하였다. 전단 하중하의 수리적 거동은 초기에는 팽창 특성을 따랐으며, 팽창의 증가에 따라 투수계수가 커겼다. 전단이 진행됨에 따라 유동률은 충전물 생성과 간극의 엇갈림으로 인해 다소 일정해졌다. 주기전단 하의 수리 거동 역시 돌출부 손상과 충전물 생성의 영향을 받았다. 또한 압축과 전단 하중하의 수리 간극과 역학 간극의 관계가 조사, 비교되었다.

  • PDF

기판 집적형 도파관(SIW)과 Complementary Split Ring Resonator(CSRR)로 구현한 저위상 잡음 발진기 설계 (Low-Phase Noise Oscillator Using Substrate Integrated Waveguide and Complementary Split Ring Resonator)

  • 박우영;임성준
    • 한국전자파학회논문지
    • /
    • 제23권4호
    • /
    • pp.468-474
    • /
    • 2012
  • 본 논문은 기판 직접형 도파관(SIW)에 complementary split ring resonator(CSRR)이 탑재된 저위상 잡음 발진기를 제안한다. SIW 캐비티의 unloaded Q-factor는 CSRR을 삽입하여 높아졌고, 그 값은 1960을 나타내고 있다. 높은 Q-factor를 나타내는 SIW 캐비티 공진기에 대한 이론적인 분석과 설계 과정이 제시되어 있으며, 설계된 회로가 11.3 dBm의 출력 파워와 1-MHz 오프셋에서 -127.9 dBc/Hz의 위상 잡음을 갖는 9.3 GHz의 신호를 발생시킴을 실험적으로 보여주고 있다.

임플랜트 상부구조의 재료가 반복하중 후 나사풀림에 미치는 영향 (AN INFLUENCE OF ABUTMENT MATERIALS ON A SCREW-LOOSENING AFTER CYCLIC LOADING)

  • 이태식;한중석;양재호;이재봉;김성훈
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.240-249
    • /
    • 2007
  • Statement of problem: A phenomenon of screw-loosening in implant abutment is frequently occurred in a single and multiple implant restoration. Purpose: This study was performed to evaluate an effect of abutment material on screw-loosening before and after a cyclic loading. In a single-tooth implant, different materials of abutment, Type III Gold alloy and Zirconium composite$(ZrO_2/Al_2O_3)$ were used. Material and method: The Gold alloy(Type III) and Zirconium composite$(ZrO_2/Al_2O_3)$ were used to make a superstructure of implant, the one of types of UCLA, Each group was constituted of 5 sample with a 30-degree offset angulated loading platform. The external hexagonal fixture was rigidly hel d in a special holding zig to ensure solid fixation without rotation during the tightening and a cyclic loading. A Titanium-alloy screw was used to connect and controlled to be tighten in 20Ncm torque by a digital torque gauge. A 20 times of consecutive closing/opening cycle were performed to evaluate the immediate torque loss. In 5 sample of each material group, an initial opening torque was recorded during 3 closing/opening cycle, then 2Hz, 200N, 1,000,000 cyclic loadings were performed, then a opening torque was evaluated. Result & Conclusion: 1. In this limited study, titanium alloy screw tightened in 20Ncm, a cold-welding phenomen on was not observed during the 20 times of closing/opening cycle(p=0.11, p=0.18). 2. In titanium alloy abutment screw, repeated opening and closing of the screw caused to progressive decrease of opening torque(p=0.014). 3. The difference in preload of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant(p=0.78). 4. The difference in torque loss of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant after 2Hz,200N, 1,000,000 cyclic loading(p=0.92). 5. In titanium alloy abutment screw tightened by 20Ncm, the screw loosening was not significant on each group after 2Hz, 200Ncm, 1,000,000 cyclic loading(p=0.59).