• Title/Summary/Keyword: loading BOD

Search Result 237, Processing Time 0.028 seconds

Delivered Pollutant Loads of Point and Nonpoint Source on the Upper Watershed of Lake Paldang - Case Study of the Watershed of Namhan River and Gyeongan Stream (팔당호 상류유역의 점·비점오염원 유달부하 특성 - 남한강·경안천 수계를 대상으로)

  • Park, Ji Hyoung;Kong, Dong Soo;Min, Kyung Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.750-757
    • /
    • 2008
  • This study is conducted to characterize and evaluate delivered pollutant loads of point and nonpoint source on the upper watershed of lake paldang. The study area consists of 12 watersheds in Namhan-river and Kyungahcheon, which are approximately 80% of total area of Namhan-river and Kyungahcheon. Based on daily delivered loads from watersheds, 61% of $BOD_5$, 81% of T-N and 70% of T-P were from nonpoint sources, suggesting that delivered loads of nonpoint pollutants be crucial to water quality. On the other hand, 78% of $BOD_5$, 92% of T-N and 87% of T-P as delivered load were from nonpoint sources in an upper watershed of Namhan-river, while 48% of $BOD_5$, 70% of T-N and 57% of T-P as delivered load were from nonpoint sources in a lower watershed of Namhan-river, suggesting higher dependency of point sources than upper watershed of Namhan-river. In the characteristic of delivered loading pollutants from point and nonpoint pollution sources, delivered load of nonpoint pollutants differed significantly by seasonal flow, and as though discharged load of point pollutants were yearly uniform, delivered load of point pollutants was found to be flow-dependent because its delivery ratio was changed.

Analysis of Water Qulity changes & Characterization at the Watershed in Han River Basin for Target indicator in TMDLs (수질오염총량관리 대상물질 확대를 위한 한강수계 하천수질 경향 및 수질특성 분석)

  • Choi, Ok Youn;Kim, Hong Tae;Seo, Hee Seung;Han, Ihn Sup
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.15-33
    • /
    • 2017
  • Based on the existing pollutant emissin standards which are armed at the pollutant concentration of each pollution source, government formulated and implemented new management system of total water pollutant emission. By virtue of this new management system, pollution loading amount of individual watershed could be controlled, which achieved the requirement of water quality management such as TP and BOD. In initiate stage of it's implement, BOD was selected as object of water quality management, While it's necessary to consider the continuity of water quality data and established pollutant management laws and policy. During the ongoing management, TP management was added into the system while simply BOD management was not enough. However, the frequency of algae bloom in Han-river showed a trend of same, even though TP was treated as additional control target. Therefore, this paper will analyze different water quality parameters and characteristic of water quality, so that this study can be provide as reference for watershed management of water quality, by which the applicable management period and target pollutant can be selected in the future.

Evaluation of Water Quality Characteristics in Gul-po Stream using Flow-Loading Equation and Correlation Analysis (유량-부하량 관계식과 상관관계 분석을 이용한 굴포천의 수질특성 평가)

  • Jang, Ji Yun;Kim, Dae Woong;Choi, Ye Ji;Jang, Dong Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.452-452
    • /
    • 2021
  • 하천 및 호소수역에 대한 수질오염원이 지속적으로 증가하는 경우에는 일반적인 농도규제 방식으로는 수질개선에 한계가 나타난다. 이를 해결하기 위해 목표 수질 한도 내에서 유역 배출원의 오염물질총량 관리를 목적으로 하는 수질오염총량관리제 개념이 도입되어 단위유역 지자체별 배출부하량을 관리하고 있지만, 지역의 오염원 배출 특성을 고려하지 않은 저감계획은 오히려 유역 내 새로운 오염원으로 전락하여 수질 개선 효과가 나타나지 않을 수 있다. 따라서 효율적인 총량 관리를 위해서는 수계 내 오염원 파악이 필수적이다. 본 연구에서는 수질오염총량제 대상 하천인 굴포천의 수질 오염원 분석을 위해 2016년, 2017년 굴포천 유역 토지이용 자료를 활용하여 수질항목과의 상관성을 파악하고 2016년부터 2020년까지 최근 5년 동안 총량측정망을 통해 측정된 유량 및 수질 자료를 이용해 상류, 중류, 하류 각각의 유량-부하량 관계식을 도출하여 지점별 수질 오염원 특성을 분석하였다. 상관분석 결과, 강우 시 밭과 BOD, SS, T-P는 양의 상관성을 보였고, T-N은 강우, 비 강우 시 관계없이 밭, 논에서 높은 양의 상관성을 보였다. 유량-부하량 관계식 도출 결과, 상류의 경우 BOD, COD, T-P, TOC, SS는 유량이 증가함에 따라 농도가 감소하는 특성을 나타내었는데 이는 2019년 4월 이후 오존처리 재이용수 방류에 따른 유량 증가의 영향이라고 사료 된다. 반면 T-N은 유량이 증가함에 따라 농도가 증가하는 특성을 나타내었는데 이는 오존처리 재이용수의 T-N 농도가 하천의 T-N 농도 보다 높아 발생한 것으로 보인다. 중류와 하류의 경우 BOD, COD, T-P, TOC, SS는 유량이 증가함에 따라 농도가 증가하는 특성을 나타내어 강우 시 비점오염원의 영향이 있는 것으로 보인다. 특히, 하류의 경우 유량이 증가함에 따라 수질 농도가 급격히 증가하여 중류에 비해 비점오염원 영향이 더 큰 것으로 나타났다.

  • PDF

Determination of EMC and Unit Loading of Rainfall Runoff from Forestry-Crops Field (산림과 밭 지역 강우 유출수의 EMC 및 원단위 산정)

  • Won, Chul-hee;Choi, Yong-hun;Seo, Ji-yeon;Kim, Ki-cheol;Shin, Min-hwan;Choi, Joong-dae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.615-623
    • /
    • 2009
  • The research of the determination of event mean concentration (EMC) was focussed combined sewer overflows and highway runoff in korea. But those of non-urban areas are few. In this study, EMC and unit loading on land use types in Nogok watershed were estimated by runoff loading of non-point source (NPS) on non-urban area. Two monitoring sites were equipped with an automatic velocity meter, flow meter, and water sampler. Monitoring was conducted at two monitering site during the rainy season. The results show that the EMC ranges in forest land use are 1.3~2.6 mg/L for BOD, 2.0~16.1 mg/L for SS, 0.1~2.1 mg/L for TN, and 0.12~0.49 mg/L for TP. The unit loading of NPS in this study was difficult to compare directly with that used conventionally because of the difference of field investigation. In near future, it needs to conduct more systematic and long-term research about NPS within the watershed. The results of this research can be used to estimate the total pollution load management system (TPLMS) program in korea.

Unit Mass Estimation and Analysis from Fiber Dyeing and Finishing Facility Nearby Nakdong River Basin (낙동강수계에서 섬유염색 및 가공 업체에 대한 공정별 원단위산정 및 분석)

  • Gu, Jung-Eun;Nah, Dong-Hoon;Lee, Seung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.765-774
    • /
    • 2009
  • Fiber Dyeing and Finishing facility has been recognized as an important pollution source due to its consumption of large volumes of water and chemicals. Unit mass discharge for the conventional water quality parameters such as flowrate, SS, $BOD_5,\;COD_{Mn},\;COD_{Cr}$, TN, TP were estimated. To represent the respective industries, three companies were carefully selected based on its manufacturing goods, flowrate and location at various unit operations and processes. More than 90% of decrease in unit mass estimation between influent and effluent of BOD was observed. But the values themselves were similar to those of Fiber Manufacturing facility due to the high loadings of organic matter. Biodegradability of influent was almost three times higher than that of effluent. Unit mass discharge estimations of unit process (estimated in this study) based on space, products and raw material were similar to those of composite process (estimated by National Institute of Environmental Research), while big difference was observed in the other factors. Unit mass discharge factors calculated in this study can be used as the reference for the estimation of water pollution loading costs in Nakdong river basin. For the effective water pollution control and management, it is essential to characterize the various types of water quality parameters from the effluents of individual industrial wastewater treatment plants.

Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water (신양천 하천수정화 연못시스템의 처리수준 및 연못반응)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.6
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.

Effect of Sampling Frequency for the Storm Runoff on BOD, T-P Loads Estimation of the Mixed Landuse Watershed (강우-유출 채수간격이 복합지목 유역의 BOD, T-P 부하량 산정에 미치는 영향)

  • Park, Hyunkyu;Beom, Jina;Choi, Dongho;Jung, Jaewoon;Jeung, Minhyuk;Kim, Youngsuk;Choi, Yujin;Jo, Youngjun;Yoon, Kwangsik
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.314-321
    • /
    • 2018
  • In order to quantify nonpoint source pollution, it was proposed to sample at regular intervals of 1 hour for the first 24 hours of storm runoff process by National Institute of Environmental Research for the mixed landuse watershed. However, high frequency sampling requires intensive laboratory analysis and labor costs. In order to investigate the effect of longer sampling interval on the load estimation compared to the 1 hour sampling method, analysis was conducted using monitoring data from rural subwatershed, urban subwatershed, and outlet of the Pungyeongjeongcheon watershed. Statistical analysis revealed that mean of load estimation was not significantly different up to 4 hour sampling frequency. However, 3 hour sampling interval was found to be appropriate for the BOD and TP when it is judged that 10% or less of the difference in loading amount between the 1 hour and other sampling interval is reasonable. The results of this study can be used to conduct an effective monitoring system.

Forecasting of changes in the water quality in Sapgyo-Lake in accordance with implementation of Total Water Pollutant Load Management System (수질오염총량관리제 시행에 따른 삽교호의 수질변화 예측)

  • Kim, Hongsu;Cho, Byunguk;Park, Sanghyun;Lee, Mukyu;Kim, Changgi;Choi, Jeongho
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.3
    • /
    • pp.209-223
    • /
    • 2019
  • Broadly speaking, in order to analyze the water quality improvement effects of the implementation of the Total Water Pollutant Management System in the Sapgy-Lake waterways, a reference was made to the [Plans for implementation of the Total Maximum Daily Load(TMDL)] in 3 cities (Cheonan, Asan, Dangjin). The results of the investigation into the plans to reduce the pollutant load show in that region show that there are plans to reduce pollution for a total of 16 reduction facilities. As for the result of the computation of the reduction in the load, these measurements were computed at the Gokgyo-stream basin and Namwon-stream basin, with BOD and T-P at the Gokgyo-stream basin reduced by 13.9 % and 13.3 %, respectively, while BOD and T-P at the Namwon-stream were reduced by 3.7 % and 3.3 %, respectively. In this way, thus using the results of the water quality forecast of Sapgyo-Lake in measures for the improvement of water quality (in accordance with the implementation of the TMDL), and using the QUAL-MEV model and EFDC model, it is noted that BOD will be improved by 26.4 % from 6.1 mg/L to 4.5 mg/L 0.0 %, T-P by 36.7 % from 0.168 mg/L to 0.107 mg/L and TOC by 26.4 % from 7.7 mg/L to 5.6 mg/L. However, it is forecasted that the targeted standards for the medium influence area will not be achieved. Evidently, Gokgyo-stream and Namwon-stream have been implementing the Total Water Pollutant Management System for the BOD items since January 1, 2019, but the Sapgyo-stream and Muhan-stream were excluded from being designated as subject regions. As such, it is noted now that it is necessary to implement the TMDL for the entire Sapgyo-Lake water systems including Sapgyo-stream and Muhan-stream in order to improve the water quality of Sapgyo-Lake, and likewise the T-P should be designated as the substance subjected to management in addition to BOD.

EFFECT OF SUYEONG RIVER WATER ON THE WATER POLLUTION OF SUYEONG BAY (수영강의 수질오탁과 그것이 광안리 해수욕장에 미치는 영향에 대하여)

  • WON Jong-Hun;LEE Bae-Jeong;SIM Mu-Gyoung;PARK Heon-Serk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.267-276
    • /
    • 1979
  • This research was conducted to evaluate tile effects of polluted Suyeong River water on the water quality of Kwangan-Ri bathing beach. The quantity of pollutant loading of Suyeong River was determined in January 1979, and the directions of tidal currents and the chemical constituents of the Suyeong Bay water were observed in May 1979. The results are as follows: The quantity of total pollutant loading which was discharged into Suyeong Bay is: BOD 75.2ton/day; COD 96.9ton/day; SS 20.5ton/day; ammonia-nitrogen 12.4ton/day; nitrate-nitrogen 430kg/day; nitrite-nitrogen 85.1kg/day; phosphate-phosphorus 594kg/day and total heavy metals 3.01ton/day. Considering the tidal current, the polluted waters of Suyeong River flow off the Kwangan-Ri beach during tile ebb tides, and flow into the Kwangan Ri beach during the flood tides. Consequently, the water quality of Kangan-Ri bathing beach is not suitable for bathing.

  • PDF

A Study on the Improvement of Treatment Efficiency for Nitrogen and Phosphorus by Improved Sewage Treatment Process in Constructed Wetland by Natural Purification Method (자연정화공법에 의한 인공습지 하수처리장에서 하수처리 공정개선에 따른 질소 및 인의 처리효율 향상 방안)

  • Seo, Dong-Cheol;Park, Woo-Young;Lim, Jong-Sir;Park, Chan-Hoon;Lee, Hong-Jae;Kim, Hong-Chul;Lee, Sang-Won;Lee, Do-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • To effectively treat the domestic sewage that was produced on a small-scale in farming and fishing village in order to encourage an ecologically friendly environment, a small-scale sewage treatment apparatus using natural purification methods that consisted of an aerobic and an anaerobic plots were constructed. The efficiency of sewage treatment according to the sewage loading was investigated to obtain the optimum sewage loading in small-scale sewage treatment apparatus. Removal rate of pollutants according to the sewage loading were in the order of $150\;Lm^{-2}day^{-1}{\fallingdotseq}300\;Lm^{-2}day^{-1}>600\;Lm^{-2}day^{-1}$. Therefore, the optimum sewage loading was 300 L m-2 day-1. Under the optimum sewage loading, removal rate of BOD, $COD_{Mn}$, turbidity, T-N and T-P were 99, 94, 99, 49 and 89%, respectively. However, to satisfy the water quality standard in effluent in small-sclae sewage treatment apparatus for domestic sewage treatment, the low removal efficiency of T-N and T-P must be improved. So to improve the removal rate of T-N and T-P, the efficiency of sewage treatment according to the improved sewage treatment process such as, re-treatment at aerobic plot, anaerobic condition of aerobic plot, changing the filter media sizes and the depths in anaerobic plot, and also addition of oyster shells to filter media at anaerobic plot were investigated. In case of 150 cm depth in anaerobic plot with filter medium A (effectivity particle size 1.50 mm) and addition of oyster shells to filter media at anaerobic plot, removal rate of T-N and T-P in both plots were increased by 10 and 3%, and 14 and 7% in comparison with 100 cm depth in anaerobic plot with filter medium B(effectivity particle size 0.95 mm), respectively. The optimum improved sewage treatment process in small-scale sewage treatment apparatus were 150 cm depth in anaerobic plot with filter medium A and addition of oyster shells to filter media at anaerobic plot.