• 제목/요약/키워드: load-deflection

검색결과 1,345건 처리시간 0.026초

경량형강 시설물의 비선형 구조해석 모델개발(II) -반강결 뼈대구조물의 해석에 대하여- (Development of the Nonlinear Structural Analysis Model for the Light-Weight Framed Structures (II))

  • 김한중;이정재
    • 한국농공학회지
    • /
    • 제40권1호
    • /
    • pp.78-87
    • /
    • 1998
  • In this study, semi-rigid light-weight framed structures analysis model (SERIFS) was developed by advancing the LEIFS model. This model enables us to analyze simultaneous effects of large deflection and semi-rigid connection by computing unbalanced load occurring in the process of repeated loading through equalization of bending moments and torsion. This model is also able to handle the effect of the semi-rigid connection and large deflection by modifying the elastic stiffness matrix using moment-rotation behavior of connection. Moment-rotation behavior of the semi-rigid connection was adopted from the experimental results of load-vertical displacement of frame element In conclusion, this model achieves to analyze the nonlinear and large deflection behavior on the semi-rigid and light-weight steel frame connection.

  • PDF

온도상승에 따른 Steel-beam의 응력 및 처짐 해석 (Stress and Deflection Analysis of Steel Beams at Elevated Temperature)

  • 장명웅;강문명;강성덕
    • 한국공간구조학회논문집
    • /
    • 제3권1호
    • /
    • pp.57-68
    • /
    • 2003
  • This paper have performed to investigate the influence of certain parameters, including the boundary condition types, load ratios of the steel beams, and span/depth ratios of the beams itself on the structural behaviour of the steel beams at elevated temperatures. This paper is analysed the stress and vertical deflection at mid-span of the steel beams at elevated temperatures and also predicted 'failure' temperatures of the steel beams at elevated temperatures. Fire analysis used here is analysed by software VULCAN. Design examples are given to describe the structural behaviour of the steel beams at elevated temperatures.

  • PDF

Dynamic analysis of concrete column reinforced with Sio2 nanoparticles subjected to blast load

  • Azmi, Masoud;Kolahchi, Reza;Bidgoli, Mahmood Rabani
    • Advances in concrete construction
    • /
    • 제7권1호
    • /
    • pp.51-63
    • /
    • 2019
  • The project focuses on the dynamic analysis of concrete beams reinforced with silica-nanoparticles under blast loading. The structure is located at two boundary conditions. The equivalent composite properties are determined using Mori-Tanak model. The structure is simulated with sinusoidal shear deformation theory. Employing nonlinear strains-displacements, stress-strain, the energy equations of beam were obtained and using Hamilton's principal, the governing equations were derived. Using differential quadrature methods (DQM) and Newmark method, the dynamic deflection of the structure is obtained. The influences of volume percent and agglomeration of silica nanoparticles, geometrical parameters of beam, boundary condition and blast load on the dynamic deflection were investigated. Results showed that with increasing volume percent of silica nanoparticles, the dynamic deflection decreases.

강섬유 혼입 폴리머 시멘트 고강도 콘크리트 보의 전단거동 (Shear Behavior of Polymer Cement High Strength Concrete Beams Mixed with Steel Fiber)

  • 곽계환;박종건;곽경헌
    • 한국농공학회지
    • /
    • 제44권1호
    • /
    • pp.93-102
    • /
    • 2002
  • Steel fiber and polymer are used widely for reinforcement material of RC structures because of its excellences of the durability, serviceability as well as mechanical properties. The purpose of this study is to investigate the shear behavior of polymer cement high strength concrete beams mixed with steel fiber. The compressive strength of concrete was based on the 100$\times$200 mm cylinder specimens. The compressive strength of concrete are 320$kgf/cm^2$, 436 $kgf/cm^2$ and 520 $kgf/cm^2$ in the 28 days. The static test was carried out to measure the ultimate load, the initial load of flexural and diagonal cracking, crack patterns and fracture modes. Also, load-strain and load-deflection examined. During the test cracks were sketched against the load values according to the growth of crack. result are as follows; (1) The failure modes of the specimens are increased in rigidity and durability with mixing steel fiber and polymer. (2) The load of initial crack was similar a theory of shear-crack strength. (3) The deflection and strain at failure load of Polymer-steel fiber high strength concrete beams were increased, improving the brittleness of the high strength concrete.

폴리머-강섬유를 혼입한 고강도 콘크리트 보의 보수·보강 (Repair and Rehabilitation of Polymer-Steel Fibrous High Strength Concrete Beams)

  • 곽계환;김원태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.135-143
    • /
    • 2002
  • This study is to investigate its use by applying stainless steel wire mash reinforcement method of construction, which is newly developed, on the high strength concrete beam mixed with polymer-steel fiber. In this test, it is investigated and observed such as follows: the ultimate load, the initial flexure crack load, the initial diagonal tension crack load, the relation between load and deflection, load-strain relation, and also crack growth and fracture aspect by increasing load. The results of this test are; first, the stainless steel wire showed some useful reinforcement effects in multiplying the steel's resisting force of moment to the tensile force of beam or slab: second, the promoting strength and internal force was made in the process of the integration at the same reaction by using the penetrating polymer-mortar with an excellent durability and physical property. On the basis of this results, because such instances in applying stainless steel wire Mash reinforcement method of construction have been few so far, through the experimental investigation such as this test over and over again, the efficient and useful method must be developed for the practice.

ON POSITIVENESS AND CONTRACTIVENESS OF THE INTEGRAL OPERATOR ARISING FROM THE BEAM DEFLECTION PROBLEM ON ELASTIC FOUNDATION

  • CHOI, SUNG WOO
    • 대한수학회보
    • /
    • 제52권4호
    • /
    • pp.1225-1240
    • /
    • 2015
  • We provide a complete proof that there are no eigenvalues of the integral operator ${\mathcal{K}}_l$ outside the interval (0, 1/k). ${\mathcal{K}}_l$ arises naturally from the deflection problem of a beam with length 2l resting horizontally on an elastic foundation with spring constant k, while some vertical load is applied to the beam.

강섬유 보강 콘크리트의 휨파괴 인성지수의 결정에 관한 비교 연구 (A Comparative Study on Flexural Toughness of Steel Fiber Reinforced Concrete)

  • 구봉근;정경섭;김태봉;박종인
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1991년도 봄 학술발표회 논문집
    • /
    • pp.69-74
    • /
    • 1991
  • This paper reviewed various methods of evaluating the toughness of fiber reinforced concrete materials by means of toughness indices and discussed the use of various multiples of first-crack deflection or first-crack secant compliance to define toughness indices. And a new method what is called effective toughness used to evaluate the toughness of steel fiber reinforced concrete. The proposed method determinded from the area below the load-deflection curve until deflection at the loading point becoms 1/150 of the span devided by the ligament area.

  • PDF

니켈-티타늄 와이어의 열처리에 따른 부하-변위 특성 변화 (Effects of heat treatment on the load-deflection properties of nickel-titanium wire)

  • 장수호;김광원;임성훈
    • 대한치과교정학회지
    • /
    • 제36권5호
    • /
    • pp.349-359
    • /
    • 2006
  • 니켈-티타늄 합금은 높은 spring-back성질, 초탄성 효과, 형상기억 효과 등의 장점을 가지고 있으나 성형이 어렵다는 단점을 가지고 있다. 본 연구에서는 니켈-티타늄 와이어의 굴곡을 위한 열처리 시에 나타나는 부하-변위 곡선의 변화 및 상전이 온도 변화와 같은 물성 변화 양상을 조사하고자 하였다. 수종의 니켈-티타늄 와이어를 열처리를 시행하지 않은 군, 전기저항 열처리 장치를 이용하여 와이어 단면적에 따라 제조회사에서 권장하는 전류를 기초로 하여 $00.016"\;{\times}\;00.022"$ (5 A, 7 sec), $0.018"\;{\times}\;0.025"$ (6 A, 7 sec) 그리고 $0.0215"\;{\times}\;0.028"$ (7 A, 8 sec) 와이어를 열처리만 시행한 실험군, 열처리를 시행하여 굴곡을 부여한 실험군 그리고 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군으로 분류하여 3점 굴곡 실험과 시차주사열량측정을 하여 다음과 같은 결과를 얻었다. $0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ 그리고 $0.0215"\;{\times}\;0.028"$ 니켈-티타늄 와이어에서 굴곡을 부여하지 않고 열처리만 시행한 실험군이 열처리를 시행하지 않은 대조군에 비해 부하-변위 곡선이 상방 이동되어 초탄성 현상에 의한 평탄역(loading and unloading plateau)의 힘이 더 증가되었다. $0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ 그리고 $0.0215"\;{\times}\;0.028"$ 와이어에서 열처리만 시행한 실험군이 열처리를 시행하지 않은 군보다 더 낮은 austenite finish ($A_f$) 온도를 보였다. $0.018"\;{\times}\;0.025"$$0.0215"0.028"$ 와이어에서 열처리를 시행하여 굴곡을 부여한 실험군은 열처리만 시행한 실험군과 열처리를 시행하지 않은 대조군에 비해 부하-변위 곡선이 상방 이동되었으며, 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군에서 가장 높은 부하-변위 곡선을 나타냈다. $0.018"\;{\times}\;0.025"$ 그리고 $0.0215"\;{\times}\;0.028"$ 와이어에서 $A_f$ 온도는 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군에서 가장 낮게 관찰되었고 열처리를 시행하여 굴곡을 부여한 실험군, 열처리만 시행한 실험군 그리고 열처리를 시행하지 않은 대조군 순으로 높게 관찰되었다. 이상의 결과를 종합할 때, 임상에서 니켈-티타늄 합금 와이어에 굴곡을 부여하기 위해 열처리하는 경우 초탄성 특성은 유지될 수 있으나, 부하-변위 곡선의 상방 증가가 나타나므로, 와이어에 의한 교정력이 증가될 수 있음에 유의하여야 한다.

외압(外壓)을 받는 축대칭(軸對稱) Shell의 한계하중(限界荷重)에 관한 연구(硏究) (Ultimate Load Analysis of Axisymmetric Shells of Revolution Subjected to External Pressure)

  • 김재복;김창렬
    • 대한조선학회지
    • /
    • 제20권4호
    • /
    • pp.1-8
    • /
    • 1983
  • This paper describes the application of the finite element method to the large deflection elastic plastic analysis and ultimate load calculation of axisymmetric shell of revolution with initial imperfection subjected to external pressure. The nonlinear equilibrium equations are linearized by the successive incremental method and are solved by the combination of load increment and iteration scheme with considering plastic deformation theory. To get the more realistic effect of large deflection, corrected coordinats and directions of applied load ar every load increment steps are used. The effects of the plasticity, initial imperfection and the shape of shells on the ultimate load of clamped circular cap under external pressure are investigated. Consequently, the following conclusions are obtained; (1) At same geometric parameter $\lambda$, each shape of clamped circular caps yield same elastic ultimate loads in both cases, i.e. with and without initial imperfections, whereas, in the case of elastic-plastic state the shell becomes thicker, the ultimate loads are getting smaller. (2) The effects of initial imperfection to ultimate load are most significant in the elastic case and are more senstive in the elastic-plastic state with the thinner shells.

  • PDF

Fire performance curves for unprotected HSS steel columns

  • Shahria Alam, M.;Muntasir Billah, A.H.M.;Quayyum, Shahriar;Ashraf, Mahmud;Rafi, A.N.M.;Rteil, Ahmad
    • Steel and Composite Structures
    • /
    • 제15권6호
    • /
    • pp.705-724
    • /
    • 2013
  • The behaviour of steel column at elevated temperature is significantly different than that at ambient temperature due to its changes in the mechanical properties with temperature. Reported literature suggests that steel column may become vulnerable when exposed to fire condition, since its strength and capacity decrease rapidly with temperature. The present study aims at investigating the lateral load resistance of non-insulated steel columns under fire exposure through finite element analysis. The studied parameters include moment-rotation behaviour, lateral load-deflection behaviour, stiffness and ductility of columns at different axial load levels. It was observed that when the temperature of the column was increased, there was a significant reduction in the lateral load and moment capacity of the non-insulated steel columns. Moreover, it was noted that the stiffness and ductility of steel columns decreased sharply with the increase in temperature, especially for temperatures above $400^{\circ}C$. In addition, the lateral load capacity and the moment capacity of columns were plotted against fire exposure time, which revealed that in fire conditions, the non-insulated steel columns experience substantial reduction in lateral load resistance within 15 minutes of fire exposure.