• Title/Summary/Keyword: load impedance control

Search Result 105, Processing Time 0.028 seconds

The Effect of the Load Resistance on Dispersion Characteristics of Metal-Fiber Composites (금속섬유 복합재료의 부하저항에 따른 분산특성)

  • Seo, Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.3
    • /
    • pp.75-81
    • /
    • 2012
  • In this paper, an efficient means to estimate the dispersion characteristics of active FSS (or ESS) is presented. We numerically investigate the effective permittivity and the transmission coefficient of 2D metal-fiber composites using linear-lumped impedance loading. We modify the GEC method which is applied to 2D fiber composite material with arbitrary fiber orientation. We show that by varying the impedance value it is possible to control the resonance frequency of the array as well as the bandwidth.

Digital Load Sharing Method for Converter parallel Operation (컨버터 병렬운전을 위한 디지털 부하분담 기법)

  • Yoo, Kwang-Min;Kim, Won-Yong;Park, Seung-Hee;Lee, Dong-Hoo;Kim, Yun-Sung;Jeong, Yu-Seok;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.150-157
    • /
    • 2012
  • This paper presents CAN-based parallel-operation and load-sharing techniques for the communication server power supply. With the load information obtained through CAN communication, each modules performs its current control independently and the power unbalance caused by impedance differences of converter modules can be reduced. In conventional method, slave modules are controlled by master module. On the other hand, the proposed load share algorithm uses the Multi-Master method. Therefore, accurate load sharing can be accomplished by the reference structure of each module's average current. Each converter has two stages and it is separated into PFC, which is responsible for harmonic regulation, and LLC resonant converter, which controls output voltage. To verified the performance of the proposed method, two 2KW prototypes has been implemented and experimented.

Programmable Smart Charger Compatible to Various Load Conditions (다양한 부하조건에 호환 가능한 프로그래머블 스마트 충전기)

  • Jo, Kang-Ta;Keum, Moon-Hwan;Han, Sang-Kyoo;Oh, Dong-Sung;Sakong, Suk-Chin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.357-363
    • /
    • 2014
  • A programmable smart charger compatible to various load conditions is proposed in this paper. Since the proposed smart charger is compatible to various mobile devices having different rated voltage and power, it is convenient for carrying and easy to standardize many kinds of battery chargers. Moreover, since it uses the input impedance and built-in PMIC (Power management IC) of the load system to recognize the connection state and specifications of load system, hardware changes of load system is not only hardly necessary but it also features no addition communication cable and easy implementation. To confirm the validity of the proposed charger, the theoretical analysis and experiment results from a prototype compatible to three load conditions 5V/1A, 5V/2A and 12V/1A are provided.

Dynamic Characterizations of a Piezoelectric Microactuator in Hard Disk Drive (HDD용 압전형 마이크로엑츄에이터의 동특성 규명)

  • Kim, Cheol-Soon;Kim, Kyu-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.232-236
    • /
    • 2000
  • To provide model parameters for servo control system design, dynamic characteristics of a piezoelectric microactuator for hard disk drive(HDD) were investigated. At first frequency response characteristics was measured and a second order model was proposed. Here the amplitude dependent dynamic characteristics such as low frequency gain and damping ratio were studied. In addition, the load current and equivalent impedance of the piezoelectric actuator were measured by varying excitation voltage and frequency. At last, the super-harmonic resonance of the piezoelectric actuator was discussed.

  • PDF

A Novel Half-Bridge Resonant Inverter With Load Free-wheeling Modes (부하 환류모드를 갖는 새로운 하프 브리지 공진형 인버터)

  • Yeon Jae-Eul;Cho Kyu-Min;Kim Hee-Jun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.3 s.303
    • /
    • pp.71-80
    • /
    • 2005
  • This paper proposes a new circuit topology of the half-bridge resonant inverter and presents its digital control scheme. As the proposed half-bridge inverter can be operated in the load-freewheeling modes, pulse width modulation (PWM) control method can be used for the output power control. The proposed half-bridge inverter can keep unity output displacement factor under the load-impedance varying conditions, if a new PWM control scheme based on the resonant frequency tracking algorithm is adopted. In this paper, the operation principle, electrical characteristics and detailed digital control scheme of the proposed half-bridge resonant inverter and loss analysis comparing with a conventional half bridge inverter is described. The experimental results of the proto-type experimental setup to verify the validity of the proposed half-bridge resonant inverter are presented and discussed.

$H_\infty$ control of contact position and force of a manipulator

  • Lee, Sangmoo;Yae, Harold
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.440-445
    • /
    • 1994
  • An application of H$_{\infty}$ synthesis to contact control of a manipulator is suggested. Based on computed torque linearization of a manipulator, a target dynamics for contact motion control is defined and used as a reference model. The target dynamics relates position and force errors through free motion impedance and force error compensators. The H$_{\infty}$ control synthesis is adopted to find an optimum the compensator for position tied force control in various directions of the end-effector. The optimization is performed on the augmented criteria, which trades off the sensitivity function of the errors and the input load at the joints. A design example of the compensator is provided that meets the design specifications.s.

  • PDF

A Study on the Control of Solenoid Valve for Heating by using Power Line Communication (PLC) (전력선 통신을 이용한 난방용 솔레노이드밸브 제어에 관한 연구)

  • 신관우;김용태;이윤섭
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.8
    • /
    • pp.647-650
    • /
    • 2003
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance, and selective possibility of frequency property. We designed the boiler temperature control system unit by using the PLC modem. We can avoid unnecessary heating of separate temperature control unit, and save the cost accordingly control stability of the proposed system is proven through the experiment.

The Control of Parallel Operation for Static UPSs (Static UPS 병렬운전 제어)

  • Kim, D.U.;Kim, Y.P.;Shin, H.J.;Baek, B.S.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2048-2050
    • /
    • 1998
  • An uninterruptible power supply(UPS) with parallel operation is used to increase the power capacity of the system or to secure higher reliability at critical loads. In the parallel operating system composed of the multiple UPSs, load-sharing, i.e. current balance control between them is key technique. Because of its low impedance and quick response characteristics, inverter output current changes very rapidly and thereby easily researches an overload condition. The difference between total load current divided by number of operating inverters and its own current is detected as unbalanced current. Then frequency and voltage are controlled to minimize the active component and the reactive component. A good performance of the proposed load-sharing technique is verified by experiments in the parallel operating system with two 40kVA UPSs.

  • PDF

General Digital Fuzzy Logic Controller Design For Resonant Inverter (공진형 인버터를 위한 범용 퍼지 논리 제어기 설계)

  • 김태언;김남수;임영도
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.60-65
    • /
    • 2004
  • Induction heating system is time varying system around curie point. So, it has many troubles which are system shut down and change the load impedance. In this paper has been designed the parallel resonant inverter which controlling the constant power and tracking the load resonant frequency with PLL is possible, in order to minimize switching losses and solve it's many troubles. The current full-bridge type parallel resonant inverter of an induction heating system was composed of IGBT in switching device. For regulating the output power of an induction heating system, the Fuzzy logic controller is used. The Fuzzy controller makes the control signal for a stable power regulating control and when reference is changed, it is superior to adaptability. It has been evaluated a stable behavior for a noise with switching and a load disturbance.

  • PDF

Wireless Parallel Operation of a Three-phase Modular UPS Inverter using Resistive Droop Control (저항성 수하 제어를 적용한 3상 모듈형 UPS 인버터의 비통신선 방식 병렬 운전)

  • Kim, Seon-Tae;Ji, Jun-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1672-1681
    • /
    • 2016
  • This paper proposes a wireless parallel operation method of three-phase modular UPS inverter using resistive droop control. Furthermore, it applies a virtual resistor to droop control so that the output impedance of UPS inverter gets closer to resistive. It makes resistive droop control effective. The simulation using PSIM was performed in order to verify the validity of proposed algorithm. After consisting two-parallel system with three-phase modular UPS inverter, the experiment according to resistive load was conducted. It demonstrated the performance of current sharing and power sharing.