• 제목/요약/키워드: load bearing test

검색결과 798건 처리시간 0.024초

산정방법에 따른 단말뚝의 지지력 비교연구 (A Comparative Study on Bearing Capacity of Single Pile Based on Calculation Method)

  • 이영대;심재현
    • 한국농공학회지
    • /
    • 제39권2호
    • /
    • pp.124-133
    • /
    • 1997
  • Pile load test is good for estimating pile bearing capacity, but using this method is limited by time and cost required. Dynamic and static method is more convenient and economical, but confidence of estimated value by dynamic and static method are lower than that of pile load test. After being compared pile bearing capacity data obtained from pile load test with those of other two methods, the results from this study were summarised as follows. For allowable bearing capacity values greater than 175t per pile, bearing capacity acquired from static method was higher than that acquired from pile load test, whereas bearing capacity acquired from pile load test was higher than that acquired from static method for values under 175 per pile. It was that variance of bearing capacity was large when bearing capacity obtained by dynamic method was higher than 250t. Also bearing capacity based on dynamic method was higher than that based on pile load test. Allowable bearing capacity get from dynamic method suggested that carefull precautions are necessary in application for allowable bearing capacity values higher than 2S0ton per pile.

  • PDF

PHC 매입말뚝의 동재하시험과 정재하시험의 지지력 비교·분석 연구 (A Comparative Study on the Bearing Capacity of Dynamic Load Test and Static Load Test of PHC Bored Pile)

  • 박종배
    • 한국지반환경공학회 논문집
    • /
    • 제18권9호
    • /
    • pp.19-31
    • /
    • 2017
  • 미국 사례의 경우 항타말뚝과 현장타설말뚝은 동재하시험과 정재하시험 지지력 상관관계 분석에서 좋은 상관관계를 나타내었다. 하지만, 국내에서는 해외에서 많이 사용하지 않는 매입말뚝으로 주로 시공을 하고 있으며, 매입말뚝의 동재하시험 신뢰성에 대해 의문이 많아 동재하시험의 신뢰도를 확인하고자 하였다. 본 연구에서는 LH 현장(천안, 인천, 의정부)에서 PHC 매입말뚝에 대하여 재하시험을 실시하였으며, 동재하시험(EOID 7회, Restrike 7회)과 정재하시험(7회) 지지력을 비교 분석하였다. 그 결과 재항타동재하지지력 및 정재하지지력 평균 값 비교 시 정재하지지력 평균 값이 약 27% 높게 나타났다(신뢰도 : 0.73, 변동계수 : 0.3). 재항타지지력(Davisson 판정 값) 및 정재하지지력(Davisson 판정 값) 평균 값 비교 시 정재하지지력(Davisson 판정 값) 평균 값이 약 27% 높게 나타났다(신뢰도 : 0.73, 변동계수 : 0.2). 동재하시험과 정재하시험의 차이를 줄이고자 본 연구에서는 수정동재하지지력(EOID의 극한선단지지력+Restrike의 극한주면마찰력)을 제시하였으며, 수정동재하지지력과 정재하지지력을 비교했을 때는 그 차이가 9%로 줄어들었다(신뢰도 : 0.91, 변동계수 : 0.2). 또한 변동계수가 0.2로 줄어들어 일관성이 증가한 것으로 나타났다.

Testing of Load Capacity of a Foil Thrust Bearing

  • Kim, Choong Hyun;Park, Jisu
    • Tribology and Lubricants
    • /
    • 제34권6호
    • /
    • pp.300-306
    • /
    • 2018
  • In this study, the performance of foil thrust bearings was investigated by performing bearing take-off and load capacity tests, using an in-house designed and manufactured vertical bearing test rig. The mean take-off rotational speed and maximum load capacity of the bearing specimen were ~18,000 rpm and ~80 kPa, respectively. The vertical bearing test rig was observed to yield higher coefficients of friction and frictional torques than a horizontal bearing test rig under identical test conditions. This was a result of its structural characteristics, in that the bearing specimen is placed atop the thrust runner, which keeps it from being separated from the runner after the bearing take-off. In addition, bearing take-off was observed at a higher runner rotational speed as this structure keeps air from flowing between the top foil and runner surfaces, which requires a higher runner speed. The parallel alignment between the bearing specimen and runner surfaces can be maintained within a certain range more easily in a vertical test rig than in a horizontal test rig. Because of these advantages, Korean Industrial Standard, KS B 2060, recommends a vertical bearing test rig as the standard test device for foil thrust bearings.

Large-scale pilot test study on bearing capacity of sea-crossing bridge main pier pile foundations

  • Zhang, Xuefeng;Li, Qingning;Ma, Ye;Zhang, Xiaojiang;Yang, Shizhao
    • Geomechanics and Engineering
    • /
    • 제7권2호
    • /
    • pp.201-212
    • /
    • 2014
  • Due to the sea-crossing bridge span is generally large and main pier pile foundations are located in deep water and carry large vertical load, sea-crossing bridge main pier pile foundations bearing mechanism and load deformation characteristics are still vague. Authors studied the vertical bearing properties of sea-crossing bridge main pier pile foundations through pilot load tests. Large tonnage load test of Qingdao Bay Bridge main pier pile program is designed by using per-stressed technique to optimize the design of anchor pile reaction beam system. Test results show that the design is feasible and effective. This method can directly test bearing capacity of main pier pile foundations, and analysis bearing behaviors from test results of sensors which embedded in the pile. Through test study the vertical bearing properties of main pier pile foundation and compared with the generally short pile, author summarized the main pier pile foundations vertical bearing capacity and the main problem of design and construction which need to pay attention, and provide a reliable basis and experience for sea-crossing bridge main pier pile foundations design and construction.

선단지지된 항타개단강관말뚝의 축하중전이거동 (Axial Load Transfer Behavior for Driven Open-ended End bearing Steel Pipe Pile)

  • 임태경;정성민;정창규;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.589-596
    • /
    • 2002
  • In this study, static pile load tests with load transfer measurement were accomplished in the field. Yield pile capacity (or ultimate pile capacity) determined by load-settlement-time relationship was determined and axial load transfer behavior was analyzed. In the test for the four test piles were behaved as end bearing pile but ratios of skin friction to total pile capacity were 27%∼33%.

  • PDF

고속 터보기계용 공기 포일 저널 베어링의 신뢰성에 관한 연구 (A Study on the Reliability of an Air Foil Journal Bearing for High Speed Turbomachinery)

  • 이용복;김태호;김창호;이남수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.199-206
    • /
    • 2002
  • This paper describes a reliability characteristics of an air foil journal bearing for high speed turbomachinery at room temperature. To verify the reliability of air foil journal bearing, lift-off characteristics, load carrying capacity, and 10,000 cycle start-stop test were performed with motor driven test rig. Lift-off test shows the relationship between the rotating speed of the shaft and the frictional torque with bearing surface. About load carrying capacity, the tested air foil journal bearing produced a load capacity of 500N at an operating speed of 15,000rpm, which is compared with results of numerical analysis and empirical coefficients. Finally, The trends in change of start torque, stop torque, and bearing temperature were shown during 10,000 cycle start-stop test of an air foil journal bearing. from the results of this work, an air foil bearing will be done well, as a supported bearing for high speed turbo-compressor.

  • PDF

고속 터보기계용 공기 포일 저널 베어링의 신뢰성에 관한 연구 (A Study on the Reliability of an Air Foil Journal Bearing for High Speed Turbomachinery)

  • 김태호;이용복;김창호;이남수
    • 한국유체기계학회 논문집
    • /
    • 제6권2호
    • /
    • pp.7-14
    • /
    • 2003
  • This paper describes reliability characteristics of an air foil journal bearing for high-speed turbomachinery at a room temperature. To verify the reliability of air foil journal bearing, lift-off characteristics, load carrying capacity, and 10,000 cycle start-stop test were performed with a motor-driven test rig. A lift-off test shows the relationship between the rotating speed of the shaft and the frictional torque with bearing surface. About a load-carrying capacity, the tested air foil journal bearing produced a load capacity of 500N at an operating speed of 15,000rpm, which is compared with results of numerical analysis and empirical coefficients. Finally, the trends in change of start torque, stop torque, and bearing temperature were shown during a 10,000-cycle start-stop test of an air foil journal bearing. We found that an air foil bearing performs well, as a supported bearing for the high-speed turbocompressor.

자갈층에 근입된 대구경 현장타설말뚝의 지지능력 확인을 위한 양방향 재하시험 적용사례 (A Case Study on Application of Bi-directional Pile Load Test for verifing the Bearing Capacity of a Large-diameter Drilled Shaft Pile)

  • 이민희;정성민;김상일;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.506-513
    • /
    • 2006
  • In this study, multi-level hi-direction pile load tests for drilled shaft pile socketed into the gravel were performed. The lower and upper hi-direction load test assemblies were located on tip of pile and 15m above the tip of pile. Based on the results of pile load test, it was analyzed bearing capacity of gravel, skin firction of upper soils and skin friction of lower soils. It was confirmed that drilled shaft socketed into the gravel had enough bearing capacity.

  • PDF

교량안전진단주기와 구조적 안전도의 상관관계 (The Relationship between Testing Period and Structural Safety on toad Bearing Test of Bridges)

  • 방명석
    • 한국안전학회지
    • /
    • 제17권3호
    • /
    • pp.102-106
    • /
    • 2002
  • The Act on Safety Management of Social Assets was established on 1995 and revised on 1999 to relieve maintenance cost of managing offices. The provision for load bearing test before opening was deleted and the number of load bearing test after opening was reduced in the Revised Act on 1999. The effect of revision is the main concern in this study. 176 technical reports on load bearing test of long span bridges are analyzed. The results show that various structural defects are inherent in recent bridges constructed since 1995. So the preservation of provisions deleted in original act is needed up to now.

CPR 말뚝의 인발재하시험을 통한 주면마찰력 평가 (Evaluation of Skin Friction Using Tensile Load Testing of CPR Piles)

  • 고진석;김정한;노정두;강성승
    • 지질공학
    • /
    • 제30권1호
    • /
    • pp.59-69
    • /
    • 2020
  • CPR 시험말뚝에 대해 인발재하시험을 실시하고, 하중-변위 곡선과 하중-침하량 곡선을 분석한 후 항복하중과 허용지지력을 산정하여 주면마찰력을 평가하였다. 하중-변위 곡선으로부터 분석된 CPR 시험말뚝의 결과에 의하면, CPR 시험말뚝의 직경이 큰 경우의 항복하중과 허용지지력이 작은 경우보다 약 1.4배 이상 크게 나타났다. 하중-침하량 곡선으로 부터 분석된 결과에 의하면, CPR 시험말뚝의 직경 D500의 허용지지력이 D400보다 약 1.2~2.1배 큰 것으로 나타났다. 하지만, Fuller 분석에 의해 산정된 허용지지력은 P-S 곡선과 log P - log S 곡선에 의해 산정된 허용지지력과 큰 차이를 보여, Fuller 분석에 의한 허용지지력 산정은 적절하지 않은 것으로 판단되었다.