• Title/Summary/Keyword: load balance control

Search Result 150, Processing Time 0.026 seconds

User Bandwidth Demand Centric Soft-Association Control in Wi-Fi Networks

  • Sun, Guolin;Adolphe, Sebakara Samuel Rene;Zhang, Hangming;Liu, Guisong;Jiang, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.2
    • /
    • pp.709-730
    • /
    • 2017
  • To address the challenge of unprecedented growth in mobile data traffic, ultra-dense network deployment is a cost efficient solution to offload the traffic over some small cells. The overlapped coverage areas of small cells create more than one candidate access points for one mobile user. Signal strength based user association in IEEE 802.11 results in a significantly unbalanced load distribution among access points. However, the effective bandwidth demand of each user actually differs vastly due to their different preferences for mobile applications. In this paper, we formulate a set of non-linear integer programming models for joint user association control and user demand guarantee problem. In this model, we are trying to maximize the system capacity and guarantee the effective bandwidth demand for each user by soft-association control with a software defined network controller. With the fact of NP-hard complexity of non-linear integer programming solver, we propose a Kernighan Lin Algorithm based graph-partitioning method for a large-scale network. Finally, we evaluated the performance of the proposed algorithm for the edge users with heterogeneous bandwidth demands and mobility scenarios. Simulation results show that the proposed adaptive soft-association control can achieve a better performance than the other two and improves the individual quality of user experience with a little price on system throughput.

A 48V-400V Non-isolated Bidirectional Soft-switching DC-DC Converter for Residential ESS (PPS 제어기법을 적용한 48V-400V 비절연 양방향 DC-DC컨버터)

  • Jeong, Hyeon-Ju;Kwon, Min-Ho;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.190-198
    • /
    • 2018
  • This paper proposes a nonisolated, bidirectional, soft-switching DC - DC converter with PWM plus phase shift (PPS) control. The proposed converter has an input-parallel/output-series configuration and can achieve the interleaving effect and high voltage gains, resulting in decreased voltage ratings in all related devices. The proposed converter can operate under zero-voltage switching (ZVS) conditions for all switches in continuous conduction mode. The power flow of the proposed converter can be controlled by changing the phase shift angle, and the duty is controlled to balance the voltage of four high voltage side capacitors. The PPS control device of the proposed converter is simple in structure and presents symmetrical switching patterns under a bidirectional power flow. The PPS control also ensures ZVS during charging and discharging at all loads and equalizes the voltage ratings of the output capacitors and switches. To verify the validity of the proposed converter, an experimental investigation of a 2 kW prototype is performed in both charging and discharging modes under different load conditions and a bidirectional power flow.

A Novel Control Scheme for T-Type Three-Level SSG Converters Using Adaptive PR Controller with a Variable Frequency Resonant PLL

  • Lin, Zhenjun;Huang, Shenghua;Wan, Shanming
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1176-1189
    • /
    • 2016
  • In this paper, a novel quasi-direct power control (Q-DPC) scheme based on a resonant frequency adaptive proportional-resonant (PR) current controller with a variable frequency resonant phase locked loop (RPLL) is proposed, which can achieve a fast power response with a unity power factor. It can also adapt to variations of the generator frequency in T-type Three-level shaft synchronous generator (SSG) converters. The PR controller under the static α-β frame is designed to track ac signals and to avert the strong cross coupling under the rotating d-q frame. The fundamental frequency can be precisely acquired by a RPLL from the generator terminal voltage which is distorted by harmonics. Thus, the resonant frequency of the PR controller can be confirmed exactly with optimized performance. Based on an instantaneous power balance, the load power feed-forward is added to the power command to improve the anti-disturbance performance of the dc-link. Simulations based on MATLAB/Simulink and experimental results obtained from a 75kW prototype validate the correctness and effectiveness of the proposed control scheme.

High Step-Down Multiple-Output LED Driver with the Current Auto-Balance Characteristic

  • Luo, Quanming;Zhu, Binxin;Lu, Weiguo;Zhou, Luowei
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.519-527
    • /
    • 2012
  • A high step-down multiple-output LED driver is proposed in this paper. Firstly, the derivation of the driver with dual-output is presented and its operation principle and steady state performance are analyzed in detail. Secondly, a high step-down N-channel LED driver is proposed and its current auto-balance characteristic and step-down ratio are analyzed. Finally, an experimental prototype is built and the experimental results are given. The theoretical analysis and experimental results show that the proposed driver has the following virtues: First, if load balancing is achieved, the voltage gain is 1/N that of a Buck driver, where N is the number of channels. Second, each output automatically has an equal output current, without requiring more current close-loop control circuits than a Buck driver. Last, the voltage stresses of the switches and diodes are lower than those of a Buck driver, meaning that lower voltage switches and diodes can be used, and a higher efficiency can be expected.

Operation Results of the SOFC System Using 2 Sub-Module Stacks (2 모듈 스택을 이용한 SOFC 시스템 운전결과)

  • Lee, Tae-Hee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.5
    • /
    • pp.405-411
    • /
    • 2010
  • A 5kW class SOFC cogeneration system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a stack, a fuel reformer, a catalytic combustor, and heat exchangers. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. A 5kW stack was designed to integrate 2 sub-modules. In this paper, the 5kW class SOFC system was operated using 2 short stacks connected in parallel to test the sub-module and the system. A short stack had 15 cells with $15{\times}15 cm^2$ area. When a natural gas was used, the total power was about 1.38 kW at 120A. Because the sub-modules were connected in parallel and current was loaded using a DC load, voltages of sub-modules were same and the currents were distributed according to the resistance of sub-modules. The voltage of the first stack was 11.46 V at 61A and the voltage of the second stack was 11.49V at 59A.

A Study on Fuzzy Control Simulator of Naturally Circulated Boiler (자연 순환식보일러의 퍼지제어 모사기 개발에 관한 연구)

  • Kim, Kwang-Sun;Kim, Sam-Un
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.543-554
    • /
    • 2000
  • The engineering equations, which have been used in many engineering companies, were employed for the dynamic modelling part in order to develop the naturally circulated boiler simulator. The fuzzy algorithm, which is similar to the algorithm of making decision by the human being, was developed for the boiler simulator controller and its simulated variables were compared with those of classical PID simulations to verify the stability and the effectiveness of fuzzy controller. The simulator is for the naturally circulated boiler and the main components are the furnace, the drum, the super heater, and the economizer. The combustion and thermal radiation dominant equations were used within the furnace and the mass conservation and the energy rate balance equations were employed for the drum part. The heat transfer rates were calculated using the logarithmic mean temperature differences both for the super heater and for the economizer. The simulations are very useful to understand the boiler operations and the engineering design of the main components. The main program was developed under the PC window condition by linking the fuzzy controller to the main boiler program using the Visual C++ language. The various operational conditions such as the abrupt changes of load, the changes of water supply pipes and the diameter of drum were simulated.

An investigation into the thermo-elasto-hydrodynamic effect of notched mechanical seals

  • Meng, Xiangkai;Qiu, Yujie;Ma, Yi;Peng, Xudong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2173-2187
    • /
    • 2022
  • A 3D thermo-elasto-hydrodynamic model is developed to analyze the sealing performance of a notched mechanical seal applied in the reactor coolant pump. In the model, the generalized Reynolds equation, the energy equation coupled with notch heat balance equation, the heat conduction equations, and the deformation equations of the sealing rings are iteratively solved by the finite element method. The film pressure and temperature distribution are obtained, and the deformation of the sealing rings is revealed to study the mechanism of the notched mechanical seals. A parameterized study is conducted to analyze the sealing performance under different operating conditions. As a comparison, the sealing performance of non-notched seals is also studied. The results show that the hydrostatic effect is dominant in the load-carrying capacity of the fluid film due to the radial mechanical and thermal deformations. The notch can cool the fluid film and influence the thermal deformation of seal rings. The sealing performance is sensitive to the pressure difference, ambient temperature, and rotational speed. It is suggested to set the notches on the softer sealing rings to acquire the greater hydrodynamic effect. Compared with the non-notched, the notched end face holds a better lubrication performance, especially under lower rotational speed.

Research on How to Set 3rd Phase Target Water Quality on the Boundary between Metropolitan Cities/Dos Specified in Nakdong River Basin (낙동강수계 3단계 광역시·도 경계지점 목표수질 설정 방법 연구)

  • Hwang, Ha Sun;Park, Ji Hyung;Kim, Yong Seok;Rhew, Doug Hee;Choi, Yu Jin;Lee, Sung Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.70-77
    • /
    • 2017
  • Total Pollution Load Control (TPLC) is a system for managing the discharge load assigned by satisfying the Target Water Quality (TWQ) in Standard Flow Conditions (SFC). TWQ for a between Metropolitan Cities/Dos Specified (Cites/Dos TWQ) is very important to be the basis of each Unit Watershed TWQ. The purpose of this study was to establish a rational and scientific 'Calculation Metohd of Cites/Dos TWQ'. A methodology for the 3rd phase 'Cites/Dos TWQ' was proposed in this study based on review of the past phase (1rd and 2rd) 'Cites/Dos TWQ' in nakdong river. And utilized water quality model to estimate 3rd phase 'Cites/Dos TWQ' The allocation method of individual discharge sources are important for estimating 'Cites/Dos TWQ' In this case, the key point of the method of calculating the total allowable individual sources is the balance of the equity and the efficiency between individual sources of reduced pollutants. Thus, water quality shall be determined with regard to the current emission levels, the reduction capacity and the technical possibilities of individual sources. We estimate 3rd phase 'Cites/Dos TWQ' according to the 'Calculation Method of Cites/Dos TWQ'.

Effect of Various Fruit-loads on Yield, Fruit Quality and Growth of 'Seolhyang' Strawberry (착과 정도가 '설향' 딸기의 수량, 과실 품질 및 생육에 미치는 영향)

  • Lee, Sang Woo;Hwang, Gap Choon;Yun, Jae Gill;Hong, Jeum Kyu;Park, Soo Jeong
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.205-211
    • /
    • 2014
  • This study aimed to examine the effect of different fruit-loads on fruit yield, quality, and plant growth of 'Seolhyang' strawberry. Fruit loads were adjusted from the first to the fourth flower cluster so that the number of fruits became 20, 25, and 30, and non-flower thinning of some was made. The more the number of fruits per plant was, the greater the total yield obtained, but marketable yield decreased and non-marketable yield increased. Compared to the treatment whose fruit load was adjusted, the control with non-flower thinning had more fruit yield in the first and second flower clusters but tended to have less fruit yield in the third and fourth flower clusters. The lower the fruit load was, the more soluble solids content of fruits increased. The lower the fruit load of a flower cluster was, the faster its harvest time reached. Harvest of fruit load of 20 was faster by 10 days in the second and fourth flower clusters relative to the control. On November 24, 2012, flowering thinning of the first flower cluster was made. On March 7, 2013, fruit dry weight of the second flower cluster was most heavy in the control. Dry weight of roots decreased in the control and the fruit load of 30 compared to November 24. On April 9, fruit dry weight of the third flower cluster did not have significant difference according to fruit load, however the more the fruit load was, the smaller dry weight of leaf, root, and crown became, which were vegetative organs. On May 12, the more the fruit load, the smaller leaf area and dry weight of vegetative organs and differences from varying fruit-loads became considerable in later period of growth. Appropriate fruit load of 'Seolhyang' strawberry were from 20 to 25. Maintaining balance between vegetative and fruit growth by adjusting fruit load is very important for stable fruit production.

Opposition Based Differential Evolution Algorithm for Dynamic Economic Emission Load Dispatch (EELD) with Emission Constraints and Valve Point Effects

  • Thenmalar, K.;Ramesh, S.;Thiruvenkadam, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1508-1517
    • /
    • 2015
  • Optimal Power dispatch is the short-term decision of the optimal output of a number of power generation facilities, to meet the system demand, with the objective of Power dispatching at the lowest possible cost, subject to transmission lines power loss and operational constraints. The operational constraint includes power balance constraint, generator limit constraint, and emission dispatch constraint and valve point effects. In this paper, Opposition based Differential Evolution Algorithm (ODEA) has been proposed to handle the objective function and the operational constraints simultaneously. Furthermore, the valve point loading effects and transmission lines power loss are also considered for the efficient and effective Power dispatch. The ODEA has unique features such as self tuning of its control parameters, self acceleration and migration for searching. As a result, it requires very minimum executions compared with other searching strategies. The effectiveness of the algorithm has been validated through four standard test cases and compared with previous studies. The proposed method out performs the previous methods.