Three-Phase Reference Current Generator Employing with Kalman Filter for Shunt Active Power Filter

  • Hasim, Ahmad Shukri Abu;Ibrahim, Zulkifilie;Talib, Md. Hairul Nizam;Dardin, Syed Mohd. Fairuz Syed Mohd.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.151-160
    • /
    • 2017
  • This paper presents a new technique of reference current generator based on Kalman filter (KF) estimator for three-phase shunt active power filter (APF). The stationary reference frame (d-q algorithm) is used to transform the load currents into DC component. The harmonics of load currents are extracted and the three-phase reference currents are generated using KF estimator. The work is simulated using Matlab/Simulink platform. To validate the simulation results, an experimental test-rig have been perform using real-time control dSPACE DS1104. In addition, hysteresis current control was used to generate the switching signal for the correction of the harmonics in the system. The non-linear load were constructed with three-phase rectifier which connected in series with inductor and parallel with resistor and capacitor. The results shows that the new technique of shunt APF embedded with KF is proven to eliminate the harmonics created by the non-linear load with some improvement on the total harmonics distortion (THD).

A Study on the load Flow Calculation for preserving off Diagonal Element in Jacobian Matrix (Jacobian 행렬의 비 대각 요소를 보존시킬 수 있는 조류계산에 관한 연구)

  • 이종기;최병곤;박정도;류헌수;문영현
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1081-1087
    • /
    • 1999
  • Load Flow calulation methods can usually be divided into Gauss-Seidel method, Newton-Raphson method and decoupled method. Load flow calculation is a basic on-line or off-line process for power system planning. operation, control and state analysis. These days Newton-Raphson method is mainly used since it shows remarkable convergence characteristics. It, however, needs considerable calculation time in construction and calculation of inverse Jacobian matrix. In addition to that, Newton-Raphson method tends to fail to converge when system loading is heavy and system has a large R/X ratio. In this paper, matrix equation is used to make algebraic expression and then to slove load flow equation and to modify above defects. And it preserve P-Q bus part of Jacobian matrix to shorten computing time. Application of mentioned algorithm to 14 bus, 39 bus, 118 bus systems led to identical results and the same numbers of iteration obtained by Newton-Raphson method. The effect of computing time reduction showed about 28% , 30% , at each case of 39 bus, 118 bus system.

  • PDF

Estimation of Pollutant Load Delivery Ratio for Flow Duration Using L-Q Equation from the Oenam-cheon watershed in Juam Lake (유량-부하량관계식을 이용한 주암호 외남천 유역의 유황별 유달율 산정)

  • Choi, Dong-Ho;Jung, Jae-Woon;Lee, Kyoung-Sook;Choi, Yu-Jin;Yoon, Kwang-Sik;Cho, So-Hyun;Park, Ha-Na;Lim, Byung-Jin;Chang, Nam-Ik
    • Journal of Environmental Science International
    • /
    • v.21 no.1
    • /
    • pp.31-39
    • /
    • 2012
  • The objective of this study is to provide pollutant loads delivery ratio for flow duration in Oenam-cheon watershed, which is upstream watershed of Juam Lake. To calculate the delivery ratio by flow duration, rating curves and discharge-loads curves using measured data were established, then Flow Duration Curve(FDC) and pollutant loads delivery ratio curves were constructed. The results show that the delivery ratios for $BOD_5$ for abundant flow($Q_{95}$), ordinary flow($Q_{185}$), low flow($Q_{275}$), and drought flow($Q_{355}$) were 23.9, 12.7, 7.1, and 2.9%, respectively. The delivery ratios of same flow regime for T-N were 58.4, 31.2, 17.2 and 7.1%, respectively. While, the delivery ratios T-P were 17.3, 7.5, 3.4, and 1.1% respectively. In general, delivery ratio of high flow condition showed higher value due to the influence of nonpoint source pollution. Based on the study results, generalized equations were developed for delivery ratio and discharge per unit area, which could be used for ungaged watershed with similar pollution sources.

Load Transfer Mechanism of Drilled Shafts in Weathered Rock (풍화된 암반에 근입된 현장타설말뚝의 하중전이 기구)

  • Kwon, Oh-Sung;Cho, Sung-Min;Jung, Sung-Jun;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.57-64
    • /
    • 2005
  • Since the allowable bearing capacities of piles in weathered/fractured rock are mainly governed by settlement, the load-displacement behavior of the rock socketed pile should be well known. To predict pile head settlement at the design stage, the exact understanding of the load-transfer mechanisms is essential. Therefore, in this research, the load-transfer mechanisms of drilled shaft socketed into weathered rock was investigated. For that, 5 cast-in-place concrete piles with diameters of 1,000 mm were socketed into weathered gneiss. The static axial load tests and the load-transfer measurements were performed to examine the axial resistant behavior of the piles. A comprehensive field/laboratory testing program on weathered rock at the field test sites was also performed to describe the in situ rock mass conditions quantitatively. And then, the effect of rock mass condition on the load transfer mechanism was investigated. The side shear resistance of the pile in moderately weathered rock reached to yielding point at a few millimeter displacements, and after that, the rate of resistance increment dramatically decreased. However, that in the highly /completely weathered rock did not show the obvious yielding point, and gradually increased showing the hyperbolic pattern until with the relatively high displacement (>10 mm). The end bearing-displacement curves showed linear increase at least until with the base displacement of approximately 10 mm, regardless rock mass conditions.

  • PDF

Compact Cascaded Quadruplet Bandpass Filter Using Modified Coaxial Cavity Resonator with Q-Factor Improvement (품질계수가 향상된 변형된 동축 공동 공진기를 이용한 다단 Quadruplet 대역통과 여파기)

  • Jang, Geon-Ho;Wang, Xu-Guang;Lee, Bo-Ram;Park, Nam-Shin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.11
    • /
    • pp.966-977
    • /
    • 2015
  • This paper presents a novel modified coaxial cavity resonator and its application to bandpass filters with compact size and improved quality factor(Q-factor). The proposed resonator is made up of ${\Gamma}-shape$ or curved four inner conductive posts within a single cavity, which provides quadruplet to realize bandpass filter. No metallic walls inside the cavity are required, and thus the utilization efficiency of the cavity space is improved. As a result, the unloaded Q can be approximately 15 % higher in comparison to the conventional coaxial resonator, or more than 35 % volume saving can be achieved while maintaining the similar Q-factor value with the conventional designs. In addition, due to the multiple cross-coupling occurring within the cavity, including the source-to-load coupling, four flexible transmission zeros can be created to realize different filtering functions. Simulations as well as experimental results of four- and eight-pole filters are presented to validate this attractive design concept. Good agreement between measured and computed results is obtained.

The Optimal Condenser Position & Capacity for Power Factor Compensation in Distribution System (배전계통의 역률보상 콘덴서의 최적 위치 및 용량 산정)

  • Jang, Jeong-Tae;Jeon Young-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1190-1197
    • /
    • 1999
  • The management of power factor(PF) in the distribution line is treated according to the measurement a month about the feeder unit at the substation. In Korea, we have not researched into power factor in distribution system due to it's less weight. The reactive power in advanced countries is controlled automatically by the compensative condenser switch on/off under the monitoring. This paper first presents the optimal condenser position and proper capacity by lagrangue factor ${\lambda}_{Q}$ which is the line loss index about reactive power unit. Therefore, the largest ${\lambda}_{Q}$ node is the condenser injection point and we find out the best condenser capacity when the line loss is saturated by the moderation of condenser volume. By this method, we suggest 0.6% uprising PF by injection of 15 kVA condenser. Additionally, PF is analysed into 5 areas; large city, middle city, small city, farm village, fishing village by the use of Power Platform which is classified the same concept of the low load management in KEPCO. Two feeders of each area are selected by the worst results of PF in specified areas.

  • PDF

Traffic Offloading in Two-Tier Multi-Mode Small Cell Networks over Unlicensed Bands: A Hierarchical Learning Framework

  • Sun, Youming;Shao, Hongxiang;Liu, Xin;Zhang, Jian;Qiu, Junfei;Xu, Yuhua
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.11
    • /
    • pp.4291-4310
    • /
    • 2015
  • This paper investigates the traffic offloading over unlicensed bands for two-tier multi-mode small cell networks. We formulate this problem as a Stackelberg game and apply a hierarchical learning framework to jointly maximize the utilities of both macro base station (MBS) and small base stations (SBSs). During the learning process, the MBS behaves as a leader and the SBSs are followers. A pricing mechanism is adopt by MBS and the price information is broadcasted to all SBSs by MBS firstly, then each SBS competes with other SBSs and takes its best response strategies to appropriately allocate the traffic load in licensed and unlicensed band in the sequel, taking the traffic flow payment charged by MBS into consideration. Then, we present a hierarchical Q-learning algorithm (HQL) to discover the Stackelberg equilibrium. Additionally, if some extra information can be obtained via feedback, we propose an improved hierarchical Q-learning algorithm (IHQL) to speed up the SBSs' learning process. Last but not the least, the convergence performance of the proposed two algorithms is analyzed. Numerical experiments are presented to validate the proposed schemes and show the effectiveness.

Adoptive Feedback Linearization Control of Three-Phase AC/DC Voltage-Source Converter (적응 궤환 선형화를 이용한 3상 AC/DC 전압원 컨버터 제어)

  • Park, Young-Hwan;Park, Jang-Hyun;Kang, Moon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.62-68
    • /
    • 2006
  • In this paper, an adaptive input-output linearization and zero dynamics control of three phase AC/DC converter are proposed. For achieving output do voltage regulation with unity power factor, the q-axis current of the rotating d-q frame is regulated to zero and the output do voltage is controlled to track a given reference voltage $V_r$. The proposed scheme is robust to the parametric uncertainty md load current of the converter due to the adaptation process. The simulation results are presented to illustrate the performance and feasibility of the proposed control scheme.

PI and Fuzzy Logic Controller Based 3-Phase 4-Wire Shunt Active Filters for the Mitigation of Current Harmonics with the Id-Iq Control Strategy

  • Mikkili, Suresh;Panda, Anup Kumar
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.914-921
    • /
    • 2011
  • Commencing with incandescent light bulbs, every load today creates harmonics. Unfortunately, these loads vary with respect to their amount of harmonic content and their response to problems caused by harmonics. The prevalent difficulties with harmonics are voltage and current waveform distortions. In addition, Electronic equipment like computers, battery chargers, electronic ballasts, variable frequency drives, and switching mode power supplies generate perilous amounts of harmonics. Issues related to harmonics are of a greater concern to engineers and building designers because they do more than just distort voltage waveforms, they can overheat the building wiring, cause nuisance tripping, overheat transformer units, and cause random end-user equipment failures. Thus power quality is becoming more and more serious with each passing day. As a result, active power filters (APFs) have gained a lot of attention due to their excellent harmonic compensation. However, the performance of the active filters seems to have contradictions with different control techniques. The main objective of this paper is to analyze shunt active filters with fuzzy and pi controllers. To carry out this analysis, active and reactive current methods ($i_d-i_q$) are considered. Extensive simulations were carried out. The simulations were performed under balance, unbalanced and non sinusoidal conditions. The results validate the dynamic behavior of fuzzy logic controllers over PI controllers.

Biosorption of Methylene Blue from Aqueous Solution using Dried Rhodotorula glutinis Biomass

  • Dae Haeng Cho;Jaesung Lee;Eui Yong Kim
    • Korean Chemical Engineering Research
    • /
    • v.61 no.2
    • /
    • pp.273-277
    • /
    • 2023
  • The biosorption of methylene blue (MB) from aqueous solution was investigated using dried Rhodotorula glutinis as the biosorbent. The effects of pH, initial dye concentration, biosorbent dosage, and kinetic studies were determined to obtain valuable information for biosorption. Results indicated that most of the adsorbed MB bound within 30 minutes of contact and the MB adsorption capacity increased from 21.1 to 101.8 mg/g with the initial MB concentration increased from 50 to 300 mg/L. Additionally, the MB adsorption capacity gradually increased from pH 4.0 to 9.0, reaching its peak at an initial pH of 9.0. As the biomass load was increased from 0.25 to 4.0 g/L, the MB removal efficiency increased from 14.1 to 84.5%. The Langmuir model provided the best fit throughout the concentration range, and the maximum adsorption capacity (qmax) and Langmuir constant (b) were determined to be 135.14 mg/g and 0.026 l/mg, respectively. Furthermore, the biosorbent process of R. glutinis was found to follow pseudo-second-order kinetics and the calculated qeq,cal value showed good agreement with the experimental qeq value. Overall, the biosorption of MB by R. glutinis can be characterized as a monolayer, single site type phenomenon, and the rate-limiting step was determined to be the chemical reaction between the adsorbent and the adsorbate.