• Title/Summary/Keyword: living waste

Search Result 162, Processing Time 0.026 seconds

Bacterial Dynamics of Biofilm Development During Toluene Degradation by Burkholderia vietnamiensis G4 in a Gas Phase Membrane Bioreactor

  • Kumar, Amit;Dewulf, Jo;Wiele, Tom Van De;Langenhove, Herman Van
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.9
    • /
    • pp.1028-1033
    • /
    • 2009
  • In this study, the dynamics of living cells (LC) and dead cells (DC) in a laboratory-scale biofilm membrane bioreactor for waste gas treatment was examined. Toluene was used as a model pollutant. The bacterial cells were enumerated as fluoromicroscopic counts during a 140 operating day period using BacLight nucleic acid staining in combination with epifluorescence and confocal laser scanning microscopy (CSLM). Overall, five different phases could be distinguished during the biofilm development: (A) cell attachment, (B) pollutant limitation, (C) biofilm establishment and colonization, (D) colonized biofilm, and (E) biofilm erosion. The bioreactor was operated under different conditions by applying different pollutant concentrations. An optimum toluene removal of 89% was observed at a loading rate of 14.4 kg $m^{-3}d^{-1}$. A direct correlation between the biodegradation rate of the reactor and the dynamics of biofilm development could be demonstrated. This study shows the first description of biofilm development during gaseous toluene degradation in MBR.

Mutagenicity of River Water of Nakdong River Estuary in Korea (낙동강 하구수의 변이원성에 대한 연구)

  • ;;Ryuich Otsu
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.35-39
    • /
    • 2001
  • The mutagenicity of the river water of Nakdong river estuary was determined by Ames test using the blue rayon suspension method. Samples were collected from 10 sites in the estuary once in each season of 1998. The samples collected from the sites where industrial waste discharge on May were mutagenic, but the other samples were not mutagenic. The sample collected from the site 1 located near the industrial area (Hadan-dong) were highly mutagenic in the TA98 with (+S9) and without (-S9) mix as well as in the TA100 with (+S9) and without (-S9) S9 mix, suggesting that the river water of this site is polluted by direct and indirect mutagens of frame-shift type as well as direct and indirect mutagens of base-replacement type. The positive mutagenicity, although relatively low, was also detected in TA98 with (+S9) and without (-S9) S9 mix in the extract of the site 4 near the industrial area(Jangrim-dong), suggesting that the primary mutation type is frame-shift. The negative mutagenicity from July to December at the sites (1-4) near the industrial area seems to be affected by the low economic growth rate in 1998 in Korea. On the other hand, the negative mutagenicity in all extracts collected from the sites 5-10 near the residential area where living sewage discharge, suggests that the river water was not polluted by mutagens.

  • PDF

Measuring Nuclear Power Plant Negative Externalities through the Life Satisfaction Approach: The Case of Ulsan City

  • LEE, KYE WOO;YOO, SE JONG
    • KDI Journal of Economic Policy
    • /
    • v.40 no.1
    • /
    • pp.67-83
    • /
    • 2018
  • We have hypothesized that nuclear risk is significantly inversely related to the distance from residences to nuclear power plants and that the level of life satisfaction of residents therefore increases with the distance. We empirically explore the relationship between Ulsan citizens' life satisfaction levels and the distance between their residences and the Kori and Wolsong nuclear power plants (NPP) based on the life satisfaction approach (LSA). The dataset we used covers only Ulsan citizens from the biennial Ulsan Statistics on Citizen's Living Condition and Consciousness of 2014 and 2016. Controlling for micro-variables such as education, work satisfaction, gender, marital status, and expenditures, we found a statistically significant relationship between life satisfaction and the distance between the residences and the nuclear power plants. Nuclear negative externalities including (i) health and environmental impact, (ii) radioactive waste disposal, and (iii) the effect of severe accidents can be quantified in terms of LS units and monetary units. We were able to calculate the monetary value of NPP externalities at $277 per kilometer of distance for Kori and $280 per kilometer of distance for Wolsong at constant 2015 prices. These estimates are quite different from the traditional estimates made with the contingent valuation method, whereas they are similar to the findings of LSA studies abroad. Hence, the need to adopt the LSA in South Korea and policy implications are demonstrated.

The Demands for Housing Regeneration of the Permanent Rental Apartment Dwellers -With Special Reference to Man-soo 7 Complex in Incheon- (영구임대아파트 거주자 주거지 재생 수요조사 연구 - 인천 만수주공 7단지 거주자를 중심으로 -)

  • Kim, Mi-Hee;Park, Byong-Gyu;Noh, Se-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.137-142
    • /
    • 2009
  • The purpose of this study is to collect baseline data about the demands for housing regeneration of the permanent rental apartment dwellers. Self-administered questionaires and interviews were provided to 144 dwellers in Incheon Man-soo 7 complex from 2008 December 29th to 31st. The collected data was used to conduct comparative and descriptive statistical analysis: frequency, t-test, and $X^2$-test. The main findings are as follows : 1. House repairing and papering is most common used service by respondents. They also have much need for economic support. 2. Residents were satisfied with general environment of house. This survey showes that the highest satisfaction was about using food waste disposal sites. and the lowest satisfaction was about soundproof facilities on the other hand, among the questions. 3. Dwellers wanted to remodeling such as bathroom, restroom, a flower garden, space of landscape architecture. More than half dwellers preferred to leave among themselves living at permanent rental apartment as it is. 4. There is important difference in the demands of housing regeneration as the family trait. and variables of those were nuclear family or elderly/handicapped-family.

  • PDF

The Demands for Housing Regeneration of the Permanent Rental Apartment Dwellers - With Special Reference to Man-soo 7 Complex in Incheon - (영구임대아파트 거주자 주거지 정비 수요조사 연구 - 인천 만수주공 7단지 거주자를 중심으로 -)

  • Kim, Mi-Hee;Park, Byong-Gyu;Noh, Se-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.43-51
    • /
    • 2010
  • The purpose of this study is to collect baseline data about the demands for housing regeneration of the permanent rental apartment dwellers. Self-administered questionnaires and interviews were provided to 144 dwellers in Incheon Man-soo 7 complex from 2008 December 29th to 31 st. The collected data was used to conduct comparative and descriptive statistical analysis: frequency, t-test, and $\chi^2$-test. The main findings are as follows: 1. House repairing and papering is most common used service by respondents. They also have much need for economic support. 2. Residents were satisfied with general environment of house. This survey shows that the highest satisfaction was about using food waste disposal sites, and the lowest satisfaction was about soundproof facilities on the other hand, among the questions. 3. Dwellers wanted to remodeling such as bathroom, restroom, a flower garden, space of landscape architecture. More than half dwellers preferred to leave among themselves living at permanent rental apartment as it is. 4. There is important difference in the demands of housing regeneration as the family trait, and variables of those were nuclear family or elderly, handicapped-family.

A New Estimation Model of MSW Generation Based on Household Composition-types and Floor Area in Apartment House (공동주택의 세대 구성유형과 면적에 따른 MSW 발생량 추정모델 개발)

  • Kim, Hyo-Kyung;Hong, Won-Hwa;Kim, Young-Chan
    • Journal of the Korean housing association
    • /
    • v.23 no.5
    • /
    • pp.41-49
    • /
    • 2012
  • As improving our standard of living, demographic change or industrial development, MSW that is closely linked to human behavior has been occurred much change. Notably, we usually have incinerated the combustible waste. In the process, they also emit a large amount of greenhouse gas that has directly affected the global warming and environmental pollution. Therefore, we need to make control system to manage future production and reduce generation of MSW. Thus this study analyzed the generation of MSW according to household members and floor area in apartment housing occupies the highest share. Then, we used both a correlation analysis and a regression analysis to make new estimation model of MSW generation. Based on this study, the results were used to suggest a method to efficiently handle MSW in the case of planning urban environment. Also, build a database to set up the integrated management system of MSW in the future.

SBA-15 Supported Fe, Ni, Fe-Ni Bimetallic Catalysts for Wet Oxidation of Bisphenol-A

  • Mayani, Suranjana V.;Mayani, Vishal J.;Kim, Sang Wook
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3535-3541
    • /
    • 2014
  • Bisphenol A is considered as pollutant, because it is toxic and hazardous to living organisms even at very low concentrations. Biological oxidation used for removing this organic from waste water is not suitable and consequently application of catalytic wet oxidation has been considered as one of the best options for treating bisphenol A. We have developed Fe/SBA-15, Ni/SBA-15 and Fe-Ni/SBA-15 as heterogeneous catalysts using the advanced impregnation method for oxidation of bisphenol A in water. The catalysts were characterized with physico-chemical characterization methods such as, powder X-ray diffraction (PXRD), FT-IR measurements, N2 adsorption-desorption isotherm, thermo-gravimetric analysis (TGA), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and inductively coupled plasma optical emission spectroscopy (ICP-OES) analysis. This work illustrates activity of the catalysts for heterogeneous catalytic degradation reaction revealed with excellent conversion and recyclability. The degradation products identified were not persistent pollutants. GC-MS analysis identified the products: 2,4-hexadienedioic acid, 2,4-pentadienic acid and isopropanol or acetic acid. The leachability study indicated that the catalysts release very little metals to water. Therefore, the possibility of water contamination through metal leaching was almost negligible.

Electric Characteristics of the MFC according to different electrode structures and materials (미생물 연료전지의 전극 재료와 구조에 따른 전기적 특성)

  • Choi, Kyu-man
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.1
    • /
    • pp.36-39
    • /
    • 2014
  • MFC(microbial fuel cell) is the device to produce the electricity by using the microbes which are living in the waste water. In this paper, the electric characteristics of the MFC were investigated according to each different structure and electrode materials. The voltage being reversed phenomenon was observed in the MFC which uses the cupper plate as the cathode material. This result comes from the oxidation reaction of the cupper plate electrode in this MFC. And this MFC has lower output voltage than one that has a platinum plate electrode. The smaller gap distance of the cupper plate electrode of the MFC showed the higher output voltage. The larger electrode area of the cupper plate electrode showed that the reaching time of the output voltage to the maximum value was delayed.

The Core Urban Design Strategies of Tall Building - Low Carbon Community

  • Liu, Enfang;Fan, Wenli;Pan, Jianing;Li, Jianqiang
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • Tall building has some controversial aspects with low carbon city, but it is still a sensible choice for the metropolitan city. This paper aims to develop holistic urban design strategies to minimize impacts on the environment, increase energy efficiency and improve the quality of living in tall building communities by utilizing tall building characteristics. It puts forward the concept of integrated tall building-low carbon community design from the perspective of urban design, and summarizes five core strategies: Temporal state based on energy use, Complementary energy use state based on functions, Spatial state based on regional environment features, Transportation state based on low-carbon lifestyle and Waste utilization state based on tall building characteristics. It also applies the strategies to a practical project. The results show that the proposed urban design strategies are available approaches to mitigate the side effects of tall building on low carbon city.

A Study on Performance Assessment of Dry Floors Applied to Long-life Housing (장수명주택에 적용되는 건식바닥의 성능평가에 관한 연구)

  • Seo, Dong-Goo;Lee, Jong-Ho;Kim, Soo-Am;Shin, Yun-Ho;Hwang, Eun-Kyoung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.5
    • /
    • pp.133-143
    • /
    • 2019
  • Various problems regarding the wet floor method such as its complicated process and waste of thermal storage have been raised, but the usage of dry floor recommended for long-life housing has declined due to lack of confidence on the performance of dry floor. The purpose of this study is to secure the credibility of dry floor. Under this purpose, this study considered precedent studies and established directions to secure the performance of long-life housing infill, and thus, 9 performance items (Impact sound, Smoothness, thermal comfort, sensation hardness while walking, falling safety, impact resistance, local compression load, local strength and strain at heating) were drawn. In addition, the experiment was carried out for 5 performances except for legal performance, some dry floor performances and whole spatial performance. As a result, an appropriate result from all performances except was obtained. The performance of dry floor was verified for each item from these results and it is expected to use such results as basic data on dry floor in the future.