• 제목/요약/키워드: liver scan

검색결과 219건 처리시간 0.027초

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • 제1권2호
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제17권2호
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.

  • PDF

A Case of Hepatopumonary Syndrome with Cyanosis (청색증으로 내원한 간폐증후군 1예)

  • Ryu, Dae-Sik;Jung, Bock-Hyun;Jung, Sang-Sik;Kim, Ho-Dong;Yoo, Chul-Hee;Kang, Kil-Hyeon;Kim, Nam-Hyeon;Jung, Seung-Mun;Park, Man-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권3호
    • /
    • pp.420-425
    • /
    • 1999
  • We report a case of hepatopulmonary syndrome defined as a triad of chronic liver disease, increased alveolar oxygen gradient on room air, and intrapulmonary arteriovenous shunting. Chest rediographs showed bilateral, basilar, medium sized reticulonodular opacities. High resolution CT scand showed multiple centrilobular nodules and branching structures in the subpleural lung that suggested dilatation of lung vessels with abnormally large number of visible terminal branches. $^{99m}Tc$-macroaggregated albumin(MAA) perfusion lung scan showed right to left shunt. Contrast echocardiography demonstrated intrapulmonary vascular shunt without intracardiac shunt.

  • PDF

Differential Absorption Analysis of Nonmagnetic Material in the Phantom using Dual CT

  • Kim, Ki-Youl;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.286-292
    • /
    • 2016
  • This study evaluates the change of computer tomography (CT) number in the case of the metal artifact reduction (MAR) algorithm, using the phantom. The images were obtained from dual CT using a gammex 467 tissue characterization phantom, which is similar to human tissues. The test method was performed by dividing pre and post MAR algorithm and measured CT values of nonmagnetic materials within the phantom. In addition, the changes of CT values for each material were compared and analyzed after measuring CT values up to 140 keV, using the spectral HU curve followed by CT scan. As a result, in the cases of N rod (trabecular bone) and E rod (trabecular bone), the CT numbers decreased as keV increasing but were constant above 90 keV. In the cases of I rod (dense bone) and K rod (dense bone), the CT numbers also decreased as keV increased but were uniform above 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of J rod (liver), D rod (liver), L rod (muscle), and F rod (muscle). For A rod (adipose), G rod (adipose), B rod (breast) and O rod (breast), the CT numbers increased as keV increased but were constant after 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of C rod (lung (exhale)), P rod (lung (exhale)), M rod (lung (inhale)) and H rod (lung (exhale)). Conclusively, because dual CT exhibits no changes in image quality and is able to analyze nonmagnetic materials by measuring the CT values of various materials, it will be used in the future as a useful tool for the diagnosis of lesions.

Celiac Artery Compression After a Spine Fracture, and Pericardium Rupture After Blunt Trauma: A Case Report from a Single Injury

  • Kim, Joongsuck;Cho, Hyun Min;Kim, Sung Hwan;Jung, Seong Hoon;Sohn, Jeong Eun;Lee, Kwangmin
    • Journal of Trauma and Injury
    • /
    • 제34권2호
    • /
    • pp.130-135
    • /
    • 2021
  • Celiac artery compression is a rare condition in which the celiac artery is compressed by the median arcuate ligament. Case reports of compression after trauma are hard to find. Blunt traumatic pericardium rupture is also a rare condition. We report a single patient who experienced both rare conditions from a single blunt injury. An 18-year-old woman was brought to the trauma center after a fatal motorcycle accident, in which she was a passenger. The driver was found dead. Her vital signs were stable, but she complained of mild abdominal pain, chest wall pain, and severe back pain. There were no definite neurologic deficits. Her initial computed tomography (CT) scan revealed multiple rib fractures, moderate lung contusions with hemothorax, moderate liver injury, and severe lumbar spine fracture and dislocation. She was brought to the angiography room to check for active bleeding in the liver, which was not apparent. However, the guide wire was not able to pass through the celiac trunk. A review of the initial CT revealed kinking of the celiac trunk, which was assumed to be due to altered anatomy of the median arcuate ligament caused by spine fractures. Immediate fixation of the vertebrae was performed. During recovery, her hemothorax remained loculated. Suspecting empyema, thoracotomy was performed at 3 weeks after admission, revealing organized hematoma without pus formation, as well as rupture of the pericardium, which was immediately sutured, and decortication was carried out. Five weeks after admission, she had recovered without complications and was discharged home.

Improvement of Low Bone Mineral Density Treated with Jeopgol-tang in a Middle-Aged Man: A Case Report (중년 남성에서 접골탕 투여 후 개선된 골밀도에 관한 증례 보고)

  • Won, Jiyoon;Choi, Youngjin;Lee, Byung-Cheol;Lee, Hyangsook
    • The Journal of Korean Medicine
    • /
    • 제42권2호
    • /
    • pp.90-97
    • /
    • 2021
  • Bone mineral density (BMD) is a major diagnostic marker for bone health. A 44-year-old male had BMD of 0.81 g/cm2 (Z-score: -3.1) in lumbar spine scan and 0.54 g/cm2 (Z-score: -2.7) for femoral neck from regular medical checkup in Apr 2020. He had no other specific medical conditions except hyperlipidemia and alcohol was a single risk factor for fracture according to Fracture Risk Assessment Tool. After he was diagnosed with liver-kidney deficiency and treated for 20 weeks with Jeopgol-tang originally patented for promoting fracture recovery, lumbar spine BMD increased by 13.6 % (0.92 g/cm2, Z-score: -2.1) and femoral neck BMD by 22.2% (0.66 g/cm2, Z-score: -1.8) compared with those of Mar 2020. Herbal medicine treatment for tonifying liver and kidney to improve BMD warrants further investigation.

The Correlation between Acholic Stool and the Result of $Tc^{99m}$ DISIDA Hepatobiliary Scintigraphy and Biochemical Test in Neonatal Cholestasis (신생아 담즙 정체증에서 무담즙변의 유무와 $Tc^{99m}$ DISIDA 간담도 주사 결과간의 상관성과 생화학적 검사의 차이에 관한 연구)

  • Joo, Eun-Young;Ahn, Yeon-Mo;Kim, Yong-Joo;Moon, Soo-Ji;Choi, Yun-Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제5권1호
    • /
    • pp.51-61
    • /
    • 2002
  • Purpose: The most common causes of neonatal cholestasis are neonatal hepatitis (NH) and extrahepatic biliary atresia (EHBA). Since neonatal cholestasis presents with variable expression of same pathologic process and has similar clinical, biochemical, and histologic features between EHBA and idiopathic neonatal hepatitis (NH), differential diagnosis is often difficult. We reviewed the differences of clinical characteristics and laboratory data to find out any correlation between the results of $Tc^{99m}$ DISIDA scan and presence of acholic stool. Methods: Between June 1993 and January 2001, total 29 infants younger than 4 month-old underwent $Tc^{99m}$ DISIDA scan. Their biochemical tests and clinical course were reviewed retrospectively. Results: Patients who had negative intestinal activity on $Tc^{99m}$ DISIDA scan showed acholic stool and revealed higher serum direct bilirubin and urine bilirubin level. 18.2% of patients with acholic stool showed intestinal activity on $Tc^{99m}$ DISIDA scan and 81.8% of them did not. All the patients without acholic stool showed positive intestinal activity on $Tc^{99m}$ DISIDA scan. The result of $Tc^{99m}$ DISIDA scan and the presence of acholic stool showed high negative correlation (r :-0.858). Patients with acholic stool and negative intestinal activity on $Tc^{99m}$ DISIDA scan showed higher serum total bilirubin level. Patients without acholic stool and positive intestinal activity on $Tc^{99m}$ DISIDA scan showed higher serum level of ALT. Conclusion: Patients with acholic stool and negative intestinal activity showed high correlation, but 18.2% of patients with acholic stool showed positive intestinal activity. So operative cholangiogram or transcutaneous liver biopsy should be performed for confirmation.

  • PDF

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • 제34권4호
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Role of Whole Body FDG-PET in the Diagnosis of Hidden Distant Metastasis before Liver Transplantation in Patients with Primary Liver Cancer (고식적 검사로 간외 전이를 진단하지 못한 원발성 간암 환자에서 간이식 전에 시행한 전신 FDG-PET의 역할)

  • Lee, Won-Woo;Ryu, Jin-Sook;Yang, You-Jung;Kim, Jae-Seung;Yeo, Jeong-Seok;Moon, Dae-Hyuk;Lee, Sung-Gyu
    • The Korean Journal of Nuclear Medicine
    • /
    • 제36권6호
    • /
    • pp.368-380
    • /
    • 2002
  • Purpose: Liver transplantation (LT), one of the therapeutic options of primary liver cancer has been suffering from recurrence caused by metastasis in 8-54% of patients. This study was performed to investigate whether FDG-PET is useful for detecting hidden metastasis in LT candidates. Materials and Methods: Twenty-six patients (male:female=23:3, mean age 55.7 years) underwent FDG-PET. Their previous conventional diagnostic studies (CDS) like abdomen US and CT, chest x-ray and CT, and bone scan were negative (n=22) or equivocal (n=4) for metastasis. Positive FDG-PET findings were confirmed by biopsy or clinical follow-up. Results: Among 4 patients with equivocal metastatic lesions on CDS, 3 had 6 hypermetabolic lesions on FDG-PET, which were confirmed as metastasis and subsequently LTs were cancelled. Of these, 5 lesions were initially negative on CDS. Remained 1 patient underwent LT with a negative FDG-PET result. Among 22 patients without metastasis on CDS, 5 had 7 hypermetabolic lesions on FDG-PET. One of these patients proved to have 2 metastatic lesions, and LT was cancelled. The other 4 patients had S hypermetabolic lesions on FDG-PET, which were confirmed as benign lesions, and 3 patients of them underwent LT. In summary, FDG-PET was useful in avoiding 4 unwarranted LT by detecting unsuspected metastatic lesions on CDS. A total of 17 patients underwent LT. In comparison with pathology, the sensitivity and specificity of FDG-PET for detecting viable primary liver cancer were 55.6% (5/9) and 87.5% (7/8), respectively. Conclusion: FDG-PET can detect additional hidden metastasis and contribute to reducing unwarranted LT in the patients with primary liver cancer.

The Clinical Usefulness of NP-59 Scintigraphy in Adrenal Cortical Diseases (NP-59 부신 신티그라피의 임상적 유용성에 관한 연구)

  • Kim, Duk-Kyu
    • The Korean Journal of Nuclear Medicine
    • /
    • 제31권1호
    • /
    • pp.108-115
    • /
    • 1997
  • $^{131}I-6{\beta}$-iodomethyl-19-norcholesterol(NP-59) has an advantage to assess adrenal dysfunction caused by adrenal cortical disorders. The aim of this study is to evaluate the clinical usefulness of NP-59 scintigraphy in each adrenal disease. Ten patients who did eleven NP-59 adrenal scintigraphies at Dong-A University Hospital from March 1990 to December 1996 were selected as the subject. Among the subject there were 5 cases of Cushing's syndrome, 2 cases of incidentaloma, 1 case of metastatic adrenal tumor, liver cirrhosis with hirsutism and hypertension respectively. Among 5 cases of Cushing's syndrome, there were 2 cases of Cushing's disease, 2 cases of adrenal adenoma and 1 case of adrenal carcinoma. There are no disagreement between clinical diagnosis and scan finding in Cushing's syndrome. In 2 incidentaloma cases, even though one is interpretated as a functioning tumor, both of 2 cases could avoid unnecessary biopsy according to scintigraphy result. One case of hirsutism, clinically adrenal originated, revealed the normal scintigraphic finding after dexamethasone suppression scan. It could suggest that the etiology of hirsutism was extra-adrenal origin. One case of hypertension took the study to exclude the possibility of primary aldosteronism. Normal suppression scan finding revealed that primary aldosteronism did not exist in this case. In conclusion, NP-59 scintigraphy was very useful in diagnosis and differential diagnosis of Cushing's syndrome and it could avoid unnecessary biopsy in the incidental adrenal tumor.

  • PDF