• Title/Summary/Keyword: liquid storage tank

Search Result 210, Processing Time 0.025 seconds

Study on the Characteristics of Hydrogen Storage according to the Structure of Storage Tank using Metal Hydride (수소저장합금을 이용한 수소저장탱크의 구조에 따른 수소저장 특성 연구)

  • Sim, Kyu-Sung;Myung, Kwang-Sik;Kim, Jung-Duk;Kim, Jong-Won
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.1
    • /
    • pp.90-99
    • /
    • 2002
  • In order to utilize hydrogen energy in a large-scale in the future, development of effective hydrogen storage method is essentially required as well as that of efficient hydrogen production method. The hydrogen storage method using metal hydrides has been holding the spotlight as a safer and higher-density hydrogen storage method than conventional hydrogen storage methods such as liquid hydrogen or compressed hydrogen storage method. However when metals react with hydrogen to store hydrogen as metal hydrides, they undergo exothermic reactions, while metal hydrides evolve hydrogen by endothermic reaction. Therefore, hydrogen storage tank should have such structure that it can absorb or release reaction heat rapidly and efficiently. In this study, a review on the improvement of the heat release and absorption structure in the hydrogen storage tank was conducted, and as a result, a new type of hydrogen storage tank with the structure of vertical-type wall was designed and manufactured. Experimental results showed that this new type of tank could be used as an efficient hydrogen storage tank because its structure is simpler and manufacture is easier than cup-type hydrogen storage tank with the structure of packed horizontal cup.

Characteristics of Earthquake Responses of a Rectangular Liquid Storage Tanks Subjected to Bi-directional Horizontal Ground Motions (수평 양방향 지반운동이 작용하는 직사각형 액체저장탱크의 지진응답 특성)

  • Lee, Jin Ho;Lee, Se Hyeok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.1
    • /
    • pp.45-53
    • /
    • 2020
  • Analytical and experimental studies show that the dynamic behavior of liquid storage tanks is significantly influenced by the fluid-structure interaction (FSI). The effects of FSI must be rigorously considered for accurate earthquake analysis and seismic design of liquid storage tanks. In this study, a dynamic analysis of a rectangular liquid storage tank subjected to bi-directional earthquake ground motions is performed and its dynamic characteristics are examined, with the effects of FSI rigorously considered. Hydrodynamic pressure is evaluated using the finite-element approach with acoustic elements and applied to the structure. The responses of the rectangular tank subjected to bi-directional earthquake ground motions are thus obtained. It can be observed that the incident angle of bi-directional horizontal ground motions has significant effects on the dynamic responses of the considered system. Therefore, the characteristics of the system must be considered in its seismic design and performance evaluation.

Earthquake Response Analysis of Cylindrical Liquid-Storage Tanks Considering Nonlinear Fluid-Structure Soil Interactions (비선형 유체-구조물-지반 상호작용 고려한 원통형 액체저장탱크의 지진응답해석)

  • Jin Ho Lee;Jeong-Rae Cho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.2
    • /
    • pp.133-141
    • /
    • 2024
  • Considering fluid-structure-soil interactions, a finite-element model for a liquid-storage tank is presented and the nonlinear earthquake response analysis is formulated. The tank structure is modeled considering shell elements with geometric and material nonlinearities. The fluid is represented by acoustic elements and combined with the structure using interface elements. To consider the soil-structure interactions, the near- and far-field regions of soil are modeled with solid elements and perfectly matched discrete layers, respectively. This approach is applied to the seismic fragility analysis of a 200,000 kL liquid-storage tank. The fragility curve is observed to be influenced by the amplification and filtering of rock outcrop motions at the site when the soil-structure interactions are considered.

Earthquake Resistant Design Critieria for Cylindrical Liquid-Storage Steel tanks (원통형 액체저장 강탱크의 내진설계기준)

  • 국승규;이진호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.19-28
    • /
    • 1999
  • While the codifying works or the earthquake resistant design codes for buildings and bridges have been carried out progressively, such works for tank structures are still at the beginning steps. In case of the collapse of tank structures under seismic actions, substantially severe damages are expected due to the spillage of tank contents in addition to the direct economic losses of tanks and contents. Therefore not only the analysis and verification methods for the dynamic behavior of tank structures but also the measures of minimizing the damage propagation should be included in the codes for tank structures. In this paper the design concepts and principles, the analysis and verification methods as well as the measures against the damage propagation are set forth, which are mandatory for the preparation of the earthquake resistant design codes for cylindrical liquid-storage steel tanks.

  • PDF

A Study on Vibration Characteristics with Sloshing Mode Effect in Water Tank Structure (유체 슬로싱모드가 탱크의 진동에 미치는 영향에 대한 연구)

  • Bae, Sung-Yong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.6
    • /
    • pp.88-95
    • /
    • 2003
  • Liquid storage rectangular tank structures are used in many fields of airplane and marine engineering. Fatigue damages are sometimes observed in these tanks which seem to be caused by resonance. Therefore it is essentially important to estimate vibration characteristics of tank structures. Many Investigators studied the vibration of cylindrical and rectangular tank structures containing still fluid. In general, the eigenbehavior of interior liquid is characterized by the sloshing mode while that of the structure by the bulging mode. However, the structure deformation to the sloshing mode and the liquid free-surface fluctuation to the bulging mode have been neglected in the classical added-mass computation. in the present paper, we study the vibration characteristics with sloshing mode effect.

Case Study on Seepage Analysis and Countermeasure Against the Seepage Flow of In-ground LNG Storage Tank (LNG 지하저장탱크의 침투해석 및 용수 대책공법에 대한 사례분석)

  • 신은철;오영인;이상혁
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.65-72
    • /
    • 2001
  • Since Pyoungtaek thermal power plant began using natural gas in 1986, the annual using volume has rapidly increased and reached 12.7 million tons in 1999. When the natural gas is cooled to a temperature of approximately -162$^{\circ}$C at atmospheric pressure, it condenses to a liquid called liquefied natural gas(LNG). LNG has a special characters such as odorless, colorless, non-corrosive, and non-toxic. So, LNG storage tank, tanker ship, transfer pipelines are required the special storage and transportation systems and technology. The presently operating LNG terminals are Pyongtaek and Inchon terminals. A total of 19 above-ground LNG storage tanks(100 thousand ㎘ grade) are currently in operation with a sendout capacity of 4,360tons/hour. To meet the growing domestic demand of LNG supply, the Inchon receiving terminal is expanding(six in-ground tank) and constructing a third LNG terminal at Tongyong. In this paper, case study on seepage analysis and countermeasure against increasing the seepage volume of in-ground LNG storage tank excavation work is reported. The results of an additional seepage analysis are presented to verify the design seepage volume of assumption section and seepage volume after curtain-grouting in the slurry wall.

  • PDF

Technical Criterion of Safety Evaluation of Leakage Preventing Plates for Alleviating Space Shortage Between Chemical Storage Tank and Dike (화학물질 저장 탱크와 방류벽 사이의 공간 부족 개선을 위한 누출 방지판의 안정성 평가 기준)

  • Lee, Eunbyul;Kwak, Sollim;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.42-50
    • /
    • 2018
  • The Chemical Controls Act strictly regulates for the chemical companies to establish sufficient space between the liquid chemical tank and dike, but facilities already installed suffer from the space shortage between the tank and dike. Installing leakage preventing plates on the dike is considered as one of the economic solutions that can alleviate the space deficiency. However, there is no technical and reasonable criterion for the safety evaluation of the leakage preventing plate on the dike. In order to address this problem, we provide generalized and verified calculating equations that give maximum height and horizontal distance of leakage trajectories. Through the proposed equations, proper heights of the leakage preventing plates on the dike can be easily determined. In this study, new calculating methods are also developed to determine the impact force of the liquid to the leakage preventing plates. In addition, we performed the reactivity experiments between four corrosive liquid chemicals and two stainless steel materials that are candidate substances for the construction of the leakage preventing plate. The results of this study is expected to be applicable as a guideline in the design of safe dike and its leakage preventing plates.

Conceptual design of hybrid electric vertical take-off and landing (eVTOL) aircraft with a liquid hydrogen fuel tank

  • Kim, Jinwook;Kwon, Dohoon;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.2
    • /
    • pp.27-38
    • /
    • 2022
  • Urban air mobility (UAM) has recently attracted lots of attention as a solution to urban centralization and global warming. Electric vertical take-off and landing (eVTOL) is a concept that emerges as one of the promising and clean technologies for UAM. There are two difficult challenges for eVTOL aircraft to solve. One is how to improve the weight efficiency of aircraft, and the other is how to complete long-range missions for UAM's flight scenarios. To approach these challenges, we propose a consolidated concept design of battery-fuel cell hybrid tiltrotor aircraft with a liquid hydrogen (LH2) fuel tank. The efficiency of a battery-fuel cell hybrid powertrain system on the designed eVTOL aircraft is compared to that of a battery-only powertrain system. This paper shows how much payload can increase and the flight scenario can be improved by hybridizing the battery and fuel cell and presenting a detailed concept of a cryogenic storage tank for LH2.

A Study on the Design Optimization of Corner Pprotection for LNG Storage Tank (LNG저장탱크 코너프로텍션의 설계 최적화에 관한 연구)

  • Kim, Hyung-Sik;Hong, Seong-Ho;Seo, Heung-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.9
    • /
    • pp.1384-1390
    • /
    • 2004
  • The full containment Liquefied Natural Gas(LNG) storage tank is based on a double liquid container concept : two separate containers, one within the other, are capable of containing the LNG. The outer concrete tank provides comer protection(secondary containment) to withstand and safely contain any spill from the inner tank. The comer protection is installed on inside corner surface of outer concrete tank. Because of high and complex stresses, corner protection is designed by ASME section ⅧI Div. 2, Appendix 4 on behalf of API 620 which is main design code for LNG tank. Design guidelines to determine design factors such as liner thickness and knuckle radius are not well understood because Appendix 4 is the design method not based on equation but FEM. Recently, the volume of LNG tank shows a tendency to increase. So it is necessary to set up the design guidelines to cope with change of LNG tank capacity and height/diameter ratio. In this paper, optimum design of corner protection was performed and the design guidelines were suggested by the results of FEM for LNG tanks which have different capacities and height/diameter ratio.

Thermal analysis of a LH2 storage for vehicles (자동차용 액체수소 저장 용기의 열해석)

  • Oh, Byeong Soo;Jung, Jin Sam
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.10 no.3
    • /
    • pp.151-157
    • /
    • 1999
  • The development of hydrogen vehicles has been actively progressed in the developed countries such as U. S., Japan and Germany. The most important technology of using hydrogen fuel is to develope a compatible storage tank with respect to the fossil fuel tank. Among many storage methods, the liquid hydrogen is the most desirable state because of the lowest volume and weight. The metal hydride tank is too heavy and the compressed hydrogen tank is too bulky. Because of these reasons, it is the principal purpose to analyze the theoretical heat transfer for designing and manufacturing an actual $LH_2$ tank. The insulation methods of the room between inner and outer vessel are non-vacuum, vacuum, vacuum with MLI(Multi-Layer Insulation). According to the results of the numerically calculated heat leak through the walls of the $LH_2$ tank, the vacuum insulated tank has 20 times and the MLI tank has 5616 times less heat leak than the non-vacuum tank.

  • PDF