• 제목/요약/키워드: liquid scintillation spectrometer

검색결과 7건 처리시간 0.024초

Uranium Analysis in Aqueous Samples by Selective Extraction and Photon-Electron Rejecting Alpha Liquid Scintillation $(PERALS^\circledR)$ Spectrometry

  • Shin, Hyun-Sang;Lee, Myung-Ho;Park, Geun-Sik;Lee, Chang-Woo
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.445-454
    • /
    • 1999
  • This work describes the adaptation of extractive scintillation by URAE $X^{TM}$ with a photon-electron rejecting alpha liquid scintillation (PERAL $S^{)}$ spectrometer to the analysis of uranium in aqueous samples. The extraction efficiency of the system was evaluated under varing chemical conditions including pH, and sample-cocktail volume ratio. Isotopic information from the (PERAL $S^{)}$ spectrum of natural uranium was obtained using a curve fitting routine. Comparisons of the result with that obtained from alpha spectrometry method using ion implanted silicon detector showed good agreement.t.

  • PDF

방사선 계측기의 품질관리 및 최소검출방사능 측정 (Quality Control of Radiation Counting Systems and Measurement of Minimum Delectable Activity)

  • 송병철;한성심;김영복;지광용;손세철
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.419-424
    • /
    • 2004
  • 방사성 폐기물 중에 함유된 핵종 및 방사능을 측정하기 위해서는 여러 가지 방사선 계측기가 이용되고 있다. 본 연구에서는 각각의 핵종에 대하여 측정 가능한 검출기를 선정하고 원전 방사성폐기물 중 방사능을 측정 하기위한 시스템을 구성하였다. 그리고 그 계측 시스템의 바탕 값 및 계측효율을 주기적으로 측정하고 품질관리를 위한 관리도를 작성하여 계측기의 안전성을 확보하고 분석결과에 대한 신뢰도를 향상시키고자 하였다. Gamma spectrometer의 바탕 값 평균은 1.59 cps이었으며 표준 시료에 대한 평균값은 45,248 dps로 거의 대부분의 측정값이 $2{\sigma}$ 이내에서 크게 벗어나지 않음을 나타냈다. Low background ${\alpha}/{\beta}$ counting 시스템의 알파 바탕 값 평균은 0.31 cpm이고 알파선 계측효율은 34.38% 이었으며, 베타 바탕 값은 1.3 cpm이고 베타선 계측효율 46.5% 이었다. 또한 액체섬광계수기는 3H 영역에서 바탕 값이 2.52 cpm, 계측효율 58.5% 이었으며, 14C 영역에서의 바탕 값은 3.31 cpm 이었고 계측효율은 95.6% 이었다. 본 연구에서는 바탕 값 및 계측효율로부터 최소검출방사능을 설정함으로써 시료의 측정 가능한 범위를 구하였다. 측정결과, gamma spectrometer의 최소검출방사능은 3.2 Bq/$m\ell$이었으며, ${\alpha}/{\beta}$counting 시스템의 경우는 알파 및 베타 영역에서 각각 20.5 Bq/$m\ell$, 23.0 Bq/$m\ell$이고 liquid scintillation counter의 경우는 3.8 Bq/$m\ell$로 나타났다.

  • PDF

감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구 (Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter)

  • 주병규;김문수;김현구;김동수;조성진;양재하;박선화;김형섭;권오상;김태승
    • 분석과학
    • /
    • 제28권3호
    • /
    • pp.228-235
    • /
    • 2015
  • 본 연구는 지하수 중 라듐(226Ra) 분석을 위해 고상추출디스크(solid phase extraction disk)를 이용한 감마선분광분석법(이하 고상추출디스크법)을 제안하고 액체섬광계수기를 이용한 액체섬광계수(liquid scintillation counter, LSC)법 및 마리넬리비커(Marinelli beaker)를 이용한 감마선분광분석기(gamma ray spectrometer)법(이하 마리넬리비커법)과의 회수율 비교를 통해 적용성을 검토하였다. 226Ra을 회수한 고상추출디스크는 딸핵종의 방출을 방지하기 위해 폴리에틸렌 필름으로 밀봉 후 감마선분광분석기로 분석하였다. 24일 경과 후, 226Ra과 딸핵종인 214Bi과 214Pb이 방사평형 된 것으로 확인되었다. 라듐 표준물질을 이용하여 고상추출디스크법으로 분석한 딸핵종 214Bi와 214Pb의 회수율은 각각 80% (295.21 Kev)와 104% (351.92 Kev)로 액체섬광계수법보다 높게 나타났다. 바탕시료(blank) 측정시 감마선분광분석기 챔버내 질소를 주입했을 경우는 주입하지 않았을 경우보다 간섭치가 약 10% 이하로 낮아지는 것을 확인하였으며, 5 L 시료를 8만초 동안 측정한 검출한계는 0.17~0.40 pCi/L로 분석되어 미국 EPA 기준치인 1pCi/L를 만족하였다. 고상추출디스크법과 액체섬광계수법을 이용한 7개 지하수 시료 분석 결과, 두 방법의 상관계수(correlation coefficient)는 0.987로 나타나 추가적인 분석을 통해 통계적 유의성을 확보한다면 고상추출디스크법의 적용가능성이 높을 것으로 판단된다. 결과적으로, 고상추출디스크법을 이용한 지하수 중 226Ra 농도 분석은 전처리 과정이 비교적 단순하여 분석시간이 절약되고 높은 회수율과 낮은 검출한계치 등의 장점을 가지고 있는 것으로 분석되었다. 또한 고상추출디스크법은 액체섬광계수법과 마리넬리비커법에 비해 많은 양의 시료를 전처리하기 쉽기 때문에 저준위 시료 분석에 유용할 것으로 판단된다.

Spectra Responsibility of Quantum Dot Doped Organic Liquid Scintillation Dosimeter for Radiation Therapy

  • Kim, Sung-woo;Cho, Byungchul;Cho, Sangeun;Im, Hyunsik;Hwang, Ui-jung;Lim, Young Kyoung;Cha, SeungNam;Jeong, Chiyoung;Song, Si Yeol;Lee, Sang-wook;Kwak, Jungwon
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.226-231
    • /
    • 2017
  • The aim is to investigate the spectra responsibilities of QD (Quantum Dot) for the innovation of new dosimetry application for therapeutic Megavoltage X-ray range. The unique electrical and optical properties of QD are expected to make it a good sensing material for dosimeter. This study shows the spectra responsibility of toluene based ZnCd QD and PPO (2.5-diphenyloxazol) mixed liquid scintillator. The QDs of 4 sizes corresponding to an emission wavelength (ZnCdSe/ZnS:$440{\pm}5nm$, ZnCdSeS:470, 500, $570{\pm}5nm$) were utilized. A liquid scintillator for control sample was made of toluene, PPO. The Composition of QD loaded scintillators are about 99 wt% Toluene as solvent, 1 wt% of PPO as primary scintillator and 0.05, 0.1, 0.2 and 0.4 wt% of QDs as solute. For the spectra responsibility of QD scintillation, they were irradiated for 30 second with 6 MV beam from a LINAC ($Infinity^{TM}$, Elekta). With the guidance of 1.0 mm core diameter optical fiber, scintillation spectrums were measured by a compact CCD spectrometer which could measure 200~1,000 nm wavelength range (CCS200, Thorlabs). We measured the spectra responsibilities of QD loaded organic liquid scintillators in two scintillation mechanisms. First was the direct transfer and second was using wave shifter. The emission peaks from the direct transfer were measured to be much smaller luminescent intensity than based on the wavelength shift from the PPO to QDs. The emission peak was shifted from PPO emission wavelength 380 nm to each emission wavelength of loaded QD. In both mechanisms, 500 nm QD loaded samples were observed to radiate in the highest luminescence intensity. We observed the spectra responsibility of QD doped toluene based liquid scintillator in order to innovate QD dosimetry applicator. The liquid scintillator loading 0.2 wt% of 500 nm emission wavelength QD has most superior responsibility at 6 MV photon beam. In this study we observed the spectra responsibilities for therapeutic X-ray range. It would be the first step of innovating new radiation dosimetric methods for radiation treatment.

액체섬광계수기를 이용한 환경시료중 $^{241}Pu$분석 (Determination of $^{241}Pu$ in Environmental Samples Using Liquid Scintillation Counting System)

  • 이명호;홍광희;최용호;김상복;최근식;이창우
    • Journal of Radiation Protection and Research
    • /
    • 제21권2호
    • /
    • pp.91-98
    • /
    • 1996
  • 알파방출핵종 존재하에 베타방출핵종인 $^{241}Pu$ 최적 분석조건을 검토하였다. 펄스파고 분석기법을 이용하여 PSA 준위를 설정하였다. $^{241}Pu$ 표준선원을 이용하여 figure of merit가 최대가 되도록 $^{241}Pu$ counting channel를 조정하였고 계측효율이 최대가 되도록 형광체 부피를 설정하였다. 최적화된 $^{241}Pu$ 분석법을 토양과 이끼등의 환경시료에 적용하여 $^{241}Pu$ 방사능농도를 측정하였고. $^{241}Pu/^{239,\;240}Pu$ 방사능 비율로부터 우리나라의 일부 토양 및 이끼에 침적된 Pu의 근원을 규명하였다.

  • PDF

$^{90}Sr,\;^{241}Am,\;^{239,240}Pu$$^{238}Pu$ 동위원소들을 분리하기위한 축차분리법에 대한 고찰 (Investigation of sequential separation method for $^{90}Sr,\;^{241}Am,\;^{239,240}Pu$ and $^{238}Pu$ isotopes)

  • 이명호;송병철;박영재;지광용;김원호
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 춘계 학술대회
    • /
    • pp.248-254
    • /
    • 2005
  • 본 연구에서는 음이온 교환수지와 Sr-Spec 수지를 사용하여 $^{90}Sr,\;^{241}Am$ 및 Pu 동위원소들에 대하여 축차적으로 분리하는 정량법을 제시하였다. Pu 동위원소는 음이온 교환수지를 이용하여 분리하였다. 아메리슘 및 스트론튬은 옥살산 공침법을 사용하여 토양 메트릭스 성분으로부터 분리하였다. 아메리슘은 철공침법을 사용하여 스트론튬으로부터 분리한후 음이온 교환수지를 사용하여 란탄나이드 성분으로부터 순수분리하였다. 스트론튬은 Sr-Spec 수지를 사용하여 순수분리하였다. Pu 및 Am 동위원소는 알파스펙트로메타로 정량하였고 Sr-90은 액체섬광계수기를 사용하여 베타선을 측정하였다. 본 연구에서 고찰된 $^{90}Sr,\;^{241}Am$ 및 Pu 동위원소 분석법을 IAEA 기준시료에 적용하여 분석법의 타당성을 검증하였다.

  • PDF

방사능 분석기술을 이용한 90Sr, 239,240Pu, 238Pu, 241Am 축차분리 (Sequential separation of 90Sr, 241Am, 239,240Pu and 238Pu by radioanalytical techniques)

  • 이명호;박경균;김종윤;박영재;김원호
    • 분석과학
    • /
    • 제18권6호
    • /
    • pp.469-474
    • /
    • 2005
  • 본 연구에서는 음이온 교환수지와 Sr-Spec 수지를 사용하여 토양중 $^{90}Sr$, $^{241}Am$ 및 Pu 동위원소들에 대하여 축차적으로 분리하는 정량법을 제시하였다. 플루토늄은 음이온 교환수지를 이용하여 분리하였고, 아메리슘 및 스트론튬은 옥살산 공침법 및 Sr-Spec 수지를 사용하여 순수 분리하였다. Pu 및 Am 동위원소는 알파 스펙트로메트리법으로 정량하였고, Sr-90은 액체섬광계수기를 사용하여 정량하였다. 본 연구에서 고찰된 $^{90}Sr$, $^{241}Am$ 및 Pu 동위원소 분석법을 IAEA 기준시료에 적용하여 분석법의 타당성을 검증하였다.