• Title/Summary/Keyword: liquid sample

Search Result 1,009, Processing Time 0.025 seconds

Determination of cyromazine residues in agricultural commodities using HPLC-UVD/MS (HPLC-UVD/MS를 이용한 농산물 중 Cyromazine의 잔류분석법)

  • Song, Lee-Seul;Kim, Young-Hak;Lee, Su-Jin;Hwang, Young-Sun;Kwon, Chan-Hyeok;Do, Jung-Ah;Oh, Jae-Ho;Im, Moo-Hyeog;Chang, Woo-Suk;Lee, Young-Deuk;Choung, Myoung-Gun
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.202-208
    • /
    • 2012
  • A high-performance liquid chromatographic (HPLC) method was developed to determine residues of cyromazine, a triazine insecticide, in agricultural commodities. Cyromazine was extracted with 90% aqueous methanol from representative crops which comprised brown rice, oyster mushroom, oriental melon, watermelon, and Chinese cabbage. Following to evaporation of methanol in the extract, the aqueous concentrate was acidified to form the protonated cyromazine. Dichloromethane partition was then applied to remove nonpolar co-extractives in the aqueous phase. Strong cation-exchange chromatography using Dowex 50W-X4 resin was employed for final purification of the extract. Cyromazine was successfully separated on a Zorbax SB-Aq $C_{18}$ column showing high retention for polar compounds. Cyromazine was sensitively quantitated by ultraviolet absorption at 214 nm. Limit of quantitation (LOQ) of the method was 0.04 mg/kg irrespective of sample types. Each crops were fortified at 3 different concentrations of cyromazine for recovery test. Mean recoveries from samples fortified at LOQ~2.0 mg/kg in triplicate ranged 80.2~103.3% in five agricultural commodities. Relative standard deviations in recoveries were all less than 6%. A selected-ion monitoring LC/MS method with electrospray ionization in positive-ion mode was also provided to confirm the suspected residue. The proposed method was reproducible and sensitive enough to routinely determine and inspect the residue of cyromazine in agricultural commodities.

Development of Rapid Analytical Method of Forbidden Medicines in Dietary Supplements Using LC-ESI-Tandem MS (LC-ESI-tandem MS를 이용한 기능성표방식품 중 부정유해물질 신속검사체계 개발)

  • Kim, Hee-Yun;Jang, Young-Mi;Joo, Hyun-Jin;Jung, Young-Hyun;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Lee, Hwa-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.372-379
    • /
    • 2007
  • A high-performance liquid chromatography-electrospray ionization (HPLC-ESI) tandem MS was developed for the rapid and simultaneous determination of forbidden medicines in dietary supplements. Thirteen medicinal components such as PDE-5 inhibitors and their analogues, and the newly identified dimethylsildenafil and xanthoanthrafil, were included in this study. After tentative standardization of molecular ions in both polarities using thirteen references on the mass spectrometer, with ESI-continuous infusion via the syringe pump method, the relative intensity of the ions present in the resulting spectra was quantitatively compared. From the results, the ion mode was selected depending on each reference's characteristics. A HPLC method coupled with the ESI mode was developed considering the matrix effect and interference depending on the type of sample. The validation test of the developed method was followed by carrying out precision, accuracy, recovery, sensitivity and linearity, etc. The method showed sufficiently high sensitivity, reproducibility, and specificity, and produced 4 times faster results when compared with the existing HPLC/UV method for the determination of forbidden compounds in dietary supplements.

Monitoring of Benzoic Acid, Sorbic Acid, and Propionic Acid in Spices (향신료에서 유래되는 안식향산, 소브산, 프로피온산의 함유량 조사)

  • Yun, Sang Soon;Lee, Sang Jin;Lim, Do Yeon;Lim, Ho Soo;Lee, Gunyoung;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.381-388
    • /
    • 2017
  • In this study, we investigated the levels of natural preservatives of benzoic acid, sorbic acid, and propionic acid in spices. The quantitative analysis was performed using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) for benzoic acid and sorbic acid and gas chromatography-mass spectrometry (GC-MS) for propionic acid. The sample was extracted with ethanol using sonication, then centrifuged and evaporated to dryness and redissolved to 1 mL with ethanol to use for the instrumental analysis. The analytical method was validated based on linearity, recovery, limit of detection (LOD), and limit of quantification (LOQ). This method was suitable to determine low amounts of naturally occurring preservatives (benzoic acid, sorbic acid, and propionic acid) in various spices. Benzoic acid, sorbic acid, and propionic acid were found in 165 samples, 88 samples, and 398 samples, respectively from the total of 493 samples. The concentration of benzoic acid, sorbic acid, and propionic acid were ranged at ND-391.99 mg/L, ND-57.70 mg/L, and ND-188.21 mg/L in spices, respectively. The highest mean levels of benzoic acid, sorbic acid, and propionic acid were found in cinnamon (167.15 mg/L), basil leaves (22.79 mg/L), and white pepper (51.48 mg/L), respectively. The results in this study provide ranges of concentration regarding naturally occurring benzoic acid, sorbic acid, and propionic acid in spices. Moreover, the results may use to the case of consumer complaint or trade friction due to the inspection services of standard criteria for the preservatives of spices.

Changes of Frozen-Thawed Semen Characteristics in Miniature Pig and Duroc (Miniature Pig와 Duroc 종간의 동결-융해 후 정액 성상 비교)

  • Lee, Y.S.;Choi, W.C.;Lee, S.H.;Cheong, H.T.;Lee, S.Y.;Yang, B.K.;Park, C.K.
    • Journal of Embryo Transfer
    • /
    • v.21 no.3
    • /
    • pp.263-271
    • /
    • 2006
  • The purpose of this study was undertaken to compare ability of frozen-thawed sperm characteristics between two strains (miniature pig and Duroc). The semen was collected by gloved-hand method into a pre-warmed ($37^{\circ}C$) thermos bottle. The semen was diluted with same volume extender and added to LEY solution for freezing. The diluted semen was placed in 0.5 ml straws, and freezing was initiated by exposing the straws to liquid nitrogen ($LN_2$) vapours for 10 min before placing them into $LN_2$ for cryopreservation. The frozen-semen straw were thawed at 20, 37 and $50^{\circ}C$ for 1 min, 45 sec and 10 sec within water-bath. The semen sample were evaluated at 0, 3, 6, 9, and 12 h after incubation at $37^{\circ}C$ for analysis of sperm ability. Abnormality of spermatozoa in miniature pig was significantly (p<0.05) higher than that in Duroc at 0, 9 and 12 h of post-thawing incubation after frozen-thawing. The percentage of F-patterned spermatozoa in miniature pig was significantly (p<0.05) lower, while the percentage of AR (acrosome reacted spermatozoa) pattern was higher in the miniature than in the Duroc. On the other hand, there was no significant difference in the viability of spermatozoa thawed at different temperature ($20^{\circ}C\;and\;37^{\circ}C$) between two species, but the viability in miniature pig was higher (p<0.05) than in Duroc when sperm was thawed at $50^{\circ}C$. In conclusion, this study suggest that suitable freezing method for miniature pig semen is required for increasing post-thawing viability and fertilization capacity.

Development of an Official Analytical Method for Determination of Imazapyr in Agricultural Commodities using HPLC-UVD (HPLC-UVD를 이용한 농산물 중 Imazapyr의 공정분석법 확립)

  • Jang, Jin;Kim, Heejung;Ko, Ah-Young;Lee, Eun-Hyang;Joo, Yoon Ji;Kim, Jinhong;Chang, Moon-Ik;Rhee, Gyu-Seek
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.1
    • /
    • pp.5-13
    • /
    • 2015
  • A chromatographic method for the determination of imazapyr, a non-selective herbicide, in agricultural commodities was developed to use safety control of pesticide residue on crops, and was fully validated as an official method for residue analysis. Agricultural commodities, mandarin (fruit), hulled rice (cereal grains), pepper (vegetables), potato (potatoes) and soybean (beans) were extracted with methanol and partitioned with dichloromethane to remove the interference obtained from sample extracts, adjusting pH to 2.5 by 4N hydrochloric acid. Finally, they were analyzed by high performance liquid chromatography coupled to UV detector (HPLC-UVD). The developed method had the linearity in the range of test concentrations with coefficients of determination ($r^2$) more than 0.99. Recovery studies were carried out at three concentration levels (LOQ, 10LOQ, and 50LOQ) performing five replicates at each level. Recoveries were ranged between 72.1 to 108.0%, with relative standard deviations less than 10%. A consistent recovery was determined according to the CODEX guidelines (CAC/GL40, 2003). Finally, LC/MS with selected ion monitoring was also applied to confirm the suspected residues of imazapyr in agricultural samples. This developed method for determination of imazapyr residues in agricultural commodities. can be used as an official method.

Simultaneous Determination of Penicillin Antibiotics in Meat using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS를 이용한 육류 중 페니실린계 항생제 8종의 동시분석 및 적용성 검증)

  • Kim, Myeong-Ae;Yoon, Su-Jin;Kim, MeeKyung;Cho, Yoon-Jae;Choi, Sun-Ju;Chang, Moon-Ik;Lee, Sang-Mok;Kim, Hee-Jeong;Jeong, Jiyoon;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.131-140
    • /
    • 2014
  • The objective of this study was to develop a simultaneous method of 8 penicillin antibiotics including amoxicillin, ampicillin, cloxacillin, dicloxacillin, nafcillin, oxacillin, penicillin G and penicillin V in meat using LC-MS/MS. The procedure involves solid phase extraction with HLB cartridge and subsequent analysis by LC-MS/MS. To optimize MS analytical condition of 8 compounds, each parameter was established by multiple reaction monitoring in positive ion mode. The chromatographic separation was achieved on a $C_{18}$ column with a mobile phase of 0.05% formic acid and 0.05% formic acid in acetonitrile at a flow rate of 0.2 mL/min for 20 min with a gradient elution. The developed method was validated for specificity, linearity, accuracy and precision in beef, pork and chicken. The recoveries were 71.0~106%, and relative standard deviations (RSD) were 4.0~11.2%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.003~0.008 mg/kg and 0.01~0.03 mg/kg, respectively, that are below maximum residue limit (MRL) of the penicillins. This study also performed survey of residual penicillin antibiotics for 193 samples of beef, pork and chicken collected from 9 cities in Korea. Penicillins were not found in all the samples except a sample of pork which contained cloxacillin (concentration of 0.08 mg/kg) below the MRL (0.3 mg/kg).

A Study on the Analysis of Five Artificial Sweetners in Beverages by HPLC/MS/MS (HPLC/MS/MS를 이용한 음료류 중 인공감미료 동시분석에 관한 연구)

  • Lee, Seong-Bong;Yong, Kum-Chan;Hwang, Sun-Il;Kim, Young-Su;Jung, You-Jung;Seo, Mi-Young;Lee, Chang-Hee;Sung, Jin-Hee;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.327-333
    • /
    • 2014
  • A method for analysis of five artificial sweetners (sodium saccharin, aspartame, acesulfame-K, sucralose, cyclamate) in beverage samples was developed using high-performance liquid chromatography/triple quadrupole mass spectrometry (HPLC/MS/MS). The method uses a single-step dilution for sample preperation. Seperation was achieved on a $C_{18}$ column ($2.1{\times}150mm$, $3.5{\mu}m$) with A- 2% methanol (1 mM ammonium acetate), B-95% methanol (1 mM ammonium acetate) as mobile phase with gradient mode. The quantitation of target compounds was performed by external calibration in selected reaction monitorning (SRM) mode. The coefficient of determination of calibration curve for sodium saccharin, aspartame, acesulfame-K, sucralose and cyclamate were 0.9957, 0.9991, 0.9943, 0.9982 and 0.9948, respectively. The limits of detection (LODs) and limits of quantitation (LOQs) were in the range of 0.001~0.022 mg/L and 0.004~0.073 mg/L, repectively. Recoveries for beverage samples were in the range of 92.76~113.50% with RSD < 10.91%. The method has applied to the determination of the five sweetners in 102 beverage samples. Three artificial sweetners-aspartame, acesulfame-K, sucralose were detected from 42 samples. Sodium saccharin and cyclamate were not detected in all samples.

Contents and Estimated Intakes of Trans Fatty Acids in Korean Diet (한국인의 식품 중 트란스 지방산의 함량과 섭취량 추정)

  • Kim, Jong-Hee;Jang, Kyung-Won;Shin, Hyo-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.1002-1008
    • /
    • 2000
  • The purpose of this study was to provide the fundamental information for establishing the database needed to estimate total intakes of trans fatty acids in Korea. The amounts of trans fatty acids contained in 164 samples including 25 samples of margarines, 21 samples of shortenings, 19 samples of vegetable salad and cooking oils, 53 samples of confectionery products, 18 samples of bakery products, 19 samples of dairy products, and 9 samples of animal fats and meats were analyzed by capillary gas liquid chromatography. The average amounts of trans fatty acids in those foods were calculated and expressed as gram per one serving. Then, the average daily intakes of trans fatty acids per capita were estimated using the analyzed amounts of trans fatty acids and the amount of yearly production for those foods. The amounts of trans fatty acids per 100 g of lipids were $2.11{\sim}33.83%$ (14.66% on average) in margarines, $1.47{\sim}44.48%$ (14.21% on average) in shortenings, $0.18{\sim}3.82$ (1.54% on average) in vegetable salad and cooking oils, $0{\sim}45.81%$ (10.92% on average) in confectionery products, $0{\sim}18.32%$ (7.87% on average) in bakery products, $0.90{\sim}4.54%$ (2.27% on average) in dairy products, and $0.61{\sim}6.07%$ (2.24% on average) in animal fats and meats. Major isomers of trans fatty acid in the sample foods were $C_{18:1}$ and $C_{18:2}$. As a result, the korean average daily intake of trans fatty acids in korea was estimated to be 2.3 g per capita. The amounts of trans fatty acids consumed from each selected food were as follows: 0.35 g from margarines, 0.57 g from shortenings, 0.11 g from vegetable salad and cooking oils, 0.65 g from confectionery products, 0.07 g from bakery products, 0.14 g from dairy products and 0.21 g from animal fats and meats.

  • PDF

Study on the Effectiveness of some Decontamination Agents against Skin Contamination of $^{137}Cs$ and $^{60}Co$ (제염제의 $^{137}Cs$$^{60}Co$에 의한 피부오염의 제염효과에 관한 연구)

  • Chon, Je-Keun;Ji, Pyung-Kook;Kwak, Sang-Soo;Kim, Byung-Tae;Park, Chong-Mook
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.7-15
    • /
    • 1998
  • In order to evaluate the effectiveness of some decontamination agents against skin contamination of $^{60}Co$ and $^{137}Cs$, the experiments were carried out in this study. In the experiments, pig skin was used instead of human skin , $^{60}CoC1_2$ and $^{137}CsCl$ were used the liquid sources of skin contamination. To examine the effectiveness of decontamination agents, skin decontamination was tried using soup, EDTA, KAERICON which was developed for decontamination of radionulides on the surface of building structure, and new decontamination agents such as IOCON, TRICON, and CHARCON, which were developed in this study. The absorption of radionuclides through the skin was evaluated by the gamma-tay detection on the surface of sample skin after radionuclides were penetrated into the skin during 16 hour soiling time. The results of this absorption experiment indicated that 11.5% and 3.2% of initial amounts of $^{137}Cs$ and $^{60}Co$, respectively, were panerated into the skin. In the experiment to remove the residual radioactivity fixed on the skin, KAERICON showed the decontamination rates up to 52.1%(decontamination factor of 2.1) and IOCON showed the equivalent decontamination rate (decontamination factor 1.9) for $^{137}Cs$. However, IOCON and CHARCON showed the poor decontamination rates of less than 20%(decontamination factor of 1.2) for $^{60}Co$, and KAERICON showed the poor decontamination rate (decontamination factor 1.1) for $^{60}Co$. For TRICON, the decontamination factors were 1.6 to 1.8 for $^{137}Cs$, and 1.0 to 1.2 for $^{60}Co$, respectively.

  • PDF

Method Development for Determination of Chlorogenic Acid and Arbutin Contents in Fruits by UHPLC-MS/MS (UHPLC-MS/MS를 이용한 과일류 중 클로로젠산 및 알부틴 동시분석법 개발)

  • Choi, Young-Ju;Jeon, Jong-Sup;Kim, Woon-Ho;Jung, You-Jung;Ryu, Ji-Eun;Choi, Jong-Chul;Chae, Kyung-Suk;Lee, Jin-Hee;Do, Young-Sook;Park, Young-Bae;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.5
    • /
    • pp.413-420
    • /
    • 2019
  • In this study, a sample preparation method and a simultaneous determination method by ultra-high performance liquid chromatography coupled with tandem mass spectrometry for 9 isomers of chlorogenic acid and arbutin in fruits were developed. The samples were extracted using 90% methanol (pH 3.0), with the solutions being shaken and then sonicated for 10 min each. After centrifugation at 4,000 rpm for 10 min, the extraction was concentrated under a vacuum at $40^{\circ}C$ using a vacuum evaporator. The residue was dissolved in 5 mL of 5% methanol and filtered through a $0.45{\mu}m$ membrane before UHPLC-MS/MS analysis. The separations were performed on a C18 column with gradient elution of water (containing 0.1% formic acid) and methanol (containing 0.1% formic acid). The specificity, linearity, limit of detection, limit of quantification, accuracy, and precision of the proposed methods were also evaluated.