• Title/Summary/Keyword: liquid recovery

Search Result 782, Processing Time 0.027 seconds

Comparison of Marker Components and Biological Activities of Socheongryong-tang by Different Extract Methods (소청룡탕 제조방법에 따른 성분 및 생리활성 비교)

  • Baek, Ka Yeon;Kim, Se Jin;Kim, Jong Beom;Lee, Jeong Hyeon;Moon, Sung Ok;Lee, Hwa Dong
    • Korean Journal of Pharmacognosy
    • /
    • v.49 no.4
    • /
    • pp.349-361
    • /
    • 2018
  • Socheongryong-tang (SCRT) was one of the major traditional herbal medicines wildly used in the treatment of respiratory disease. SCRT is being commercially produced in the form of mix extracts powder and soft dry extract by different extract methods in the Korean Herbal Pharmacopeia (KHP). In this study, the contents of marker components and biological activities of the SCRT mix extract powder were compared with those of the SCRT decoction. To analyze the marker components of SCRT, nine marker from eight herbal preparations were chosen. And the method using high performance liquid chromatography (HPLC) with diode-array detector method was established for the simultaneous analysis. Method validation was accomplished by linearity, precision test, and recovery test. The contents of nine marker components in this extract was ascertained by ratio. The biological activities were examined the effect of SCRT on anti-oxidation and pro-inflammation mediated by LPS-stimulation. We confirmed that both of SCRT mix extrct powder and decoction have the similar contents on total polyphenol and flavonoid and inhibited the secretion of nitric oxide (NO), $IL-1{\beta}$, IL-6, tumor necrosis factor $(TNF)-{\alpha}$ and the expression of iNOS, COX-2, $IL-1{\beta}$, IL-6, $TNF-{\alpha}$. These results suggest that SCRT mix extract powder and decoction have a significant correlation.

Cryopreservation of Citrus limon (L.) Burm. F Shoot Tips Using a Droplet-vitrification Method

  • Yi, Jung-Yoon;Balaraju, Kotnala;Baek, Hyung-Jin;Yoon, Mun-Seop;Kim, Haeng-Hoon;Lee, Young-Yi
    • Korean Journal of Plant Resources
    • /
    • v.31 no.6
    • /
    • pp.684-694
    • /
    • 2018
  • This study describes the successful establishment of a cryopreservation protocol for Citrus limon cultivars: 'Frost Eureka limon' and 'Cook Eureka limon', using a droplet-vitrification method. The shoot tips that were excised from in vitro grown seedlings of the two cultivars were preserved in liquid nitrogen (LN) and successfully regenerated into whole plants. Excised shoot tips were pre-cultured for 1 or 2 days in 0.3 M and 0.5 M sucrose solutions at $25^{\circ}C$ and incubated in a loading solution (LS) composed of 17.5% glycerol + 17.5% sucrose in Murashige and Skoog (MS) medium for 40 min at $25^{\circ}C$. Prior to direct immersion in LN for 1 h, the shoot tips were dehydrated with plant vitrification solution 2 (PVS2) at $0^{\circ}C$ or PVS3 at $25^{\circ}C$. The frozen shoot tips were re-warmed and unloaded with 1.2 M sucrose in $\text\tiny{^1/_2}$ MS for 30 min at $25^{\circ}C$. Shoot tips were post-cultured overnight on survival medium and then micrografted onto 'trifoliate orange' (Poncirus trifoliate (L.) Raf. seedling rootstocks for recovery and to produce whole plants. The highest regrowth rates were 53.5% and 50.3% for cryopreserved shoot tips of 'Frost Eureka limon' and 'Cook Eureka limon', respectively, when pre-cultured in 0.3 M and 0.5 M sucrose concentrations in a sequencing manner, with LS and treated with PVS2 for 60 min at $0^{\circ}C$. We also investigated whether the ammonium ion concentration on post-culture medium affected the viability of the cryopreserved Citrus shoot tips. The viability of cooled samples, following culturing on woody plant media (WPM) containing $\text\tiny{^1/_4}$ ammonium nitrate overnight before micrografting, was the highest (70.3%) in 'Frost Eureka limon'. The study described here is a cost-effective and safe method to conserve Citrus fruit cultivars, for the improvement and large-scale multiplication of fruit plants and for breeding disease resistance.

Commercial pasteurization of foods using high voltage pulsed electric fields treatment (고전압 펄스 전기장을 이용한 식품의 상업적 살균)

  • Shin, Jung-Kue
    • Food Science and Industry
    • /
    • v.53 no.3
    • /
    • pp.284-294
    • /
    • 2020
  • High voltage pulsed electric field technology has been attracting attention in the the food industry as an eco-friendly nonthermal process technology using electrical energy. The lack of understanding of the equipment and the burden of equipment cost have not significantly increased the commercial application, but the potential as a technology to replace the heat process has been continuously increased. Sterilization of foods using the PEF process has been applied to liquid foods with low viscosity such as fruit and vegetable juices, but recently, high viscosity smoothies, high concentrate protein drink, mixed juice, and alcoholic beverages. Studies on sterilization of solid foods such as powders, raw meats are also being conducted. Also, the application of extraction and recovery of useful ingredients, activation of active compounds, pretreatment of drying, improvement of meat quality, changes of properties of starch has been studies.

Optimization of the Pt Nanoparticle Size and Calcination Temperature for Enhanced Sensing Performance of Pt-Decorated In2O3 Nanorods

  • Choi, Seung-Bok;Lee, Jae Kyung;Lee, Woo Seok;Ko, Tae Gyung;Lee, Chongmu
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1444-1451
    • /
    • 2018
  • The surface-to-volume ratio of one-dimensional (1D) semiconductor metal-oxide sensors is an important factor for achieving good gas sensing properties because it offers a wide response area. To exploit this effect, in this study, we determined the optimal calcination temperature to maximize the specific surface area and thereby the sensitivity of the sensor. The $In_2O_3$ nanorods were synthesized by using vapor-liquid-solid growth of $In_2O_3$ powders and were decorated with the Pt nanoparticles by using a sol-gel method. Subsequently, the Pt nanoparticle-decorated $In_2O_3$ nanorods were calcined at different temperatures to determine the optimal calcination temperature. The $NO_2$ gas sensing properties of five different samples (pristine uncalcined $In_2O_3$ nanorods, Pt-decorated uncalcined $In_2O_3$ nanorods, and Pt-decorated $In_2O_3$ nanorods calcined at 400, 600, and $800^{\circ}C$) were determined and compared. The Pt-decorated $In_2O_3$ nanorods calcined at $600^{\circ}C$ showed the highest surface-to-volume ratio and the strongest response to $NO_2$ gas. Moreover, these nanorods showed the shortest response/recovery times toward $NO_2$. These enhanced sensing properties are attributed to a combination of increased surface-to-volume ratio (achieved through the optimal calcination) and increased electrical/chemical sensitization (provided by the noble-metal decoration).

Determination of cyromazine in commercial insecticides using HPLC-DAD

  • Kim, Young-Wook;Han, Bok Hee;Kang, Young Eun;Rhee, Chae Hong;Seo, Sang-Ji;Kim, Soohee;Jeong, Wooseog;Her, Moon
    • Korean Journal of Veterinary Service
    • /
    • v.43 no.4
    • /
    • pp.261-265
    • /
    • 2020
  • Each commercial cyromazine insecticide has different HPLC conditions. The aim of this study was to establish a standardized chromatographic method for the determination of cyromazine in commercial insecticides. The separation was achieved on two C18 columns - Waters® Bondapak C (4×300 nm i.d., 10 ㎛) and X bridge (4.6×250 nm i.d., 5 ㎛) using a mobile phase composed of water/methanol/ethanolamine (76:24:0.1, v/v), with UV detection at wavelengths 230 nm and 254 nm. A total of six commercial cyromazine insecticides were analyzed. In this study, the optimal high-performance liquid chromatography conditions for the analysis of cyromazine were as follows: a mobile phase of water/methanol/ethanolamine (76:24:0.1, v/v) at a flow rate of 1.0 mL/min and a detection wavelength of 230 nm using a X bridge C18 column (4.6×250 nm i.d., 5 ㎛) at a column temperature of 25℃. The calibration curve was linear in the concentration range of 5~50 ㎍/mL, with a correlation coefficient of 0.99995. The cyromazine detection limit was 0.2 ㎍/mL, and the limit of quantification was 0.59 ㎍/mL. The percentage recovery ranged from 99.8% to 101.0% for cyromazine, and the relative standard deviation was not over 2.0%. The cyromazine concentration ranged from 92.7% to 109.4% and was within the acceptable range (90~120%) for the percent of the labeled amount. This method was found to be suitable for determining cyromazine in commercial insecticides.

Analysis of the current status and implications of nitrogen recovery from livestock manure (가축분뇨로부터 질소 회수 연구 현황 및 시사점 분석)

  • Im, Seongwon;Kim, Sangmi;Kim, Jimin;Kim, Dong-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.1
    • /
    • pp.37-46
    • /
    • 2021
  • Nitrogen and phosphorus in livestock manure are environmental pollutants, but also could be valuable industrial resources. In the present study, we (1) introduced various nitrogen removal technologies such as stripping, thermal method, membrane, and electrodialysis, (2) reviewed relevant studies reported in 2011-2020, in particular, full-scale experiences, and (3) assessed each technologies based on the above survey results. In addition, we provided the information on the appropriate range of the pH, temperature, gas and liquid ratio, and so on in ammonia stripping process, and expected mass balance when it is connected to biogasification process. We hope the content herein can be helpful for making policy and operating full-scale plant in Korea.

Content Comparative Analysis and Classification for Piniellia ternate, P. pedatisecta and Typhonium flagelliforme by HPLC-PDA analysis (HPLC-PDA를 이용한 반하, 호장남성, 수반하의 분류 및 함량분석)

  • Jo, Ji Eun;Lee, A Yeong;Kim, Hyo Seon;Moon, Byeong Cheol;Choi, Goya;Ji, Yunui;Kim, Ho Kyoung
    • The Korea Journal of Herbology
    • /
    • v.28 no.5
    • /
    • pp.95-101
    • /
    • 2013
  • Objectives : A quantitative method using high performance liquid chromatography with a photodiode array detector(HPLC-PDA) was established for the quantitative analysis of the four main compound and pattern analysis to classification Piiellia ternate, P. pedatisecta and Typhonium flagelliforme. Methods : The analytical procedure for the determination of P. ternata, together with the known main compounds uracil, uridine, guanosine and adenosine was established. Optimum HPLC-PDA separation of these P. ternata was possible on Luna C18(2) column material, using water and acetonitrile as mobile phase. The method was validated according to regulatory guidelines. In addition, this assay method were analyzed for the content of four main compound in P. ternata, P. pedatisecta and T. flagelliforme and by data obtained from the HPLC-PDA analysis was performed principal component analysis(PCA). Results : Validation results indicated that the HPLC method is well suited for the determination of the roots of P. ternata with a good linearity ($r^2$ > 0.999), precision and recovery rates. Analysis of HPLC-PDA, the average content of uracil, uridine, guanosine and adenosine was significantly higher in P. ternate>P. pedatisecta> T. flagelliforme order. The application of PCA to main compound data by HPLC-PDA permitted the effective discrimination among the three species. Conclusions : Analysis of both HPLC-PDA and PCA confirmed the fact that four main compound and pattern profiles of P. ternata, P. pedatisecta and T. flagelliforme were different from each other.

Simultaneous Determination of 80 Unapproved Compounds using HPLC and LC-MS/MS in Dietary Supplements

  • Kwon, Jeongeun;Shin, Dasom;Kang, Hui-Seung;Suh, Junghyuck;Lee, Gunyoung;Lee, Eunju
    • Mass Spectrometry Letters
    • /
    • v.13 no.3
    • /
    • pp.58-83
    • /
    • 2022
  • We developed analytical methods using high performance chromatography (HPLC) and liquid chromatography tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 80 unapproved compounds in dietary supplements. The target compounds for analysis were unapproved ingredients (e.g., pharmaceuticals) that have potential adverse effects on consumers owing to accidental misuse, overuse, and interaction with other medication in dietary supplement. Two analytical methods were tested to identify the optimal validation results according to AOAC guideline. As a result, limit of quantification (LOQ) was 0.14-0.5 ㎍ mL-1; linearity (r2) was ≥ 0.99; accuracy (expressed as recovery) was 78.9-114%; precision (relative standard deviation) was ≤ 4.28% in the HPLC method. In the LC-MS/MS method, LOQ was 0.01-2 ng mL-1, linearity (r2) was ≥0.98, accuracy was 71.7-119%; precision was ≤ 12.5%. The developed methods were applied to 51 dietary supplements collected from 2019 to 2021 through MFDS alert system. Based on our previous monitoring study, major compounds were icariin, sibutramine, yohimbine, sildenafil, tadalafil, sennosides (A, B), cascarosides (A, B, C, D), and phenolphthalein. In this study, we re-analyzed samples of detected compounds, and evaluated the statistical difference using Bland-Altman analysis to compare two analytical approaches between HPLC and LC-MS/MS. These results showed a good agreement between two methods that can be used to monitor the unapproved ingredients in dietary supplements. The developed two methods are complementarily suitable for monitoring the adulteration of 80 unapproved compounds in dietary supplements.

Simultaneous Analysis of Prohibited Antibiotics (Fluoroquinolones) in Seawater and Effluents Released by Aquaculture Using LC-MS/MS (LC-MS/MS를 이용한 해수 및 수산용수 중 플루오로퀴놀론계 항생제 동시 분석법 정립)

  • Mikyoung Lee;In-Seok Lee;Minkyu Choi;Sunggyu Lee;Won-Chan Lee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.4
    • /
    • pp.428-437
    • /
    • 2023
  • A simultaneous analytical method was developed and validated for the analysis of prohibited fluoroquinolone (FQ) antibiotics including norfloxacin, ofloxacin, and pefloxacin, released by aquaculture in seawater and effluents. The samples were filtered, and extracts were obtained using a solid phase extraction cartridge with methanol (MeOH). The extracts were concentrated, and analyzed using ultra-performance liquid chromatography-tandem mass spectrometry. Two different columns and four different mobile phases were compared to achieve optimal separation and sensitivity for target compounds. Typical validation parameters including linearity, recovery of surrogate standard, instrument detection limit (IDL), limit of quantification (LOQ), and method detection limit (MDL) were evaluated. The linearity of calibration curves was over 0.999. Recoveries of surrogate ranged from 87.6% to 113%. The LOQ of target compounds was approximately 3-8 times lower than those reported in previous studies. The IDL and MDL were 0.06-0.57 and 0.06-0.37 ng/L, respectively. Seven effluent samples collected from an aquaculture located in Jeju were analyzed; however, not all target compounds were detected in the samples, suggesting that the banned antibiotics were not used. Overall, this established method was able to simultaneously analyze the three FQ antibiotics, and may be useful for monitoring prohibited antibiotics in the fishery industry.

Manufacture Technology of Monoammonium phosphate from LCD Waste Acid (LCD 제조공정의 혼합폐산으로부터 일인산암모늄 제조 기술)

  • Lee, Ha-Young;Lee, Sang-Gil;Park, Sung-Kook;Kim, Ju-Han;Kim, Ju-Yup;Kim, Jun-Young
    • Clean Technology
    • /
    • v.15 no.4
    • /
    • pp.253-257
    • /
    • 2009
  • The waste solution discharged form the LCD(Liquid Crystal Display) manufacturing process contains phosphoric acid, nitric acid, acetic acid and metal ions such Al and other impurities. In this study, vacuum evaporation and diffusion dialysis was developed to commercialize an efficient system for recovering the high-purity phosphoric acid and manufacturing monoammonium phosphate. By vacuum evaporation, almost 99% of nitric and acetic acid was removed. Also, by diffusion dialysis, about 97.5% of Al was removed. Monoammonium phosphate was manufactured from purified phosphoric acid and ammonium hydroxide. In order to get the optimum manufacturing condition, the molar ratio of ammonium hydroxide and phosphoric acid, pH and temperature was controlled. Using this optimum condition, we obtained the recovery rate of monoammonium phosphate of about 90%.