• Title/Summary/Keyword: liquid food

Search Result 2,110, Processing Time 0.033 seconds

Processing Conditions for Seasoned-Dried Pacific Saury Treated with Liquid Smoke

  • Cha, Yong-Jun;Park, Sung-Young;Jeong, Eun-Jeong;Jung, Yeon-Jung;Kim, So-Jung
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.10a
    • /
    • pp.143-144
    • /
    • 2001
  • Among dark fleshed fishes, especially, Pacific saury has not well been used for processing because of its properties of weak tissue and high lipid content. If a simple and modified technique such as liquid smoking method for Pacific saury processing is applied successfully, it could give a lot of advantages on the field of fishery processing. In the aspects of effective utilization of dark fleshed fishes, therefore, we have attempted to process seasoned-dried Pacific saury with commercial liquid smoke. (omitted)

  • PDF

Changes in Taste Compounds of Seasoned-Dried Pacific Saury Treated with Liquid Smoke During Storage

  • Park, Sung-Young;Cho, Woo-Jin;Kim, Hun;Kim, So-Jung;Cha, Yong-Jun
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.10a
    • /
    • pp.139-140
    • /
    • 2001
  • Among dark fleshed fishes, especially, Pacific saury has not well been used for processing because of its properties of we tissue and high lipid contents. As an aspect of utilization of dark fleshed fishes effectively, therefore, application of simple and modified technique such as liquid smoking method to Pacific saury could be beneficial to fishery processing field. The objective of this study is to examine taste compounds of seasoned-dried Pacific saury treated with liquid smoke during storage (omitted)

  • PDF

Changes of Physico-Chemical Properties in Liquid-type Yogurt with Lactobacillus casei 00692 duirng Fermentation

  • Jeon, B.J.;Wang, M.K.;Kwak, H.S.
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2004.05a
    • /
    • pp.345-348
    • /
    • 2004
  • This study was carried out to find the physico-chemical attributes for liquid-type yogurt with Lactobacillus casei 911LC during 72 hr fermentation at $37^{\circ}C$. The pH decreased up to 32 hr and plauteaued thereafter. The growth of lactic acid bacteria sharply increased with $2.0{\times}\;10^6\;cfu/mL$ up to 40 hr of fermentation and slowly increased thereafter. The free amino acids produced during the fermentation reached the maximum value at 40 hr and gradually decreased thereafter. The present data showed that the range of optimum fermentation time for liquid-type yogurt using Lactobacillus casei 00692 was from 40 to 44 hr.

  • PDF

Quality Characteristics of Wheat Nuruks by Storage Conditions of Liquid Starters Using Rhizopus oryzae N174 (Rhizopus oryzae N174를 이용한 액체종국 저장조건에 따른 밀누룩의 품질특성)

  • Choi, Jeong-Sil;Jung, Seok-Tae;Choi, Ji-Ho;Choi, Han-Seok;Baek, Seong-Yeol;Yeo, Soo-Hwan
    • Microbiology and Biotechnology Letters
    • /
    • v.40 no.4
    • /
    • pp.319-324
    • /
    • 2012
  • Production of liquid starters using wheat bran as a medium for Rhizopus oryzae N174 and the changes in their characteristics noted during storage were investigated in this study. The optimal culture conditions of the liquid starters were determined to be 5~15% (w/v) wheat bran and 48~72 hrs of incubation. The effects of liquid starters with different storage periods and temperatures (-18, 4, 10 and $25^{\circ}C$) on the quality of wheat nuruk were evaluated. According to the results of the pH, acidity, reducing sugar and enzyme activities, it was found that liquid starter using wheat bran preserved for one day, at any temperature, is the best method of storage for seed cultures for R. oryzae N174.

Comparison of Anaerobic Digestion Efficiency with Different Temperature of Food Wastes (음식물류폐기물의 성상별 온도변화에 따른 혐기성소화 효율 비교 연구)

  • Hwang, Kwanghyun;Kim, Dongik
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.4
    • /
    • pp.332-339
    • /
    • 2019
  • A comparative study on the anaerobic digestion efficiency according to the temperature change was conducted considering the characteristics of domestic food wastes with high water content of about 80 % or more. The substrate was tested for anaerobic digestion efficiency in two substrates, a liquid component separated naturally from food waste and food waste itself. In the anaerobic digestion experiments, the digestion efficiency was the highest at $55^{\circ}C$ (thermophilic temperature). However, the digestion efficiency at $45^{\circ}C$(middle high temperature) was lower than that at $35^{\circ}C$(mesophilic temperature). The comparison of general food wastes anaerobic digestion requiring 30 days of hydraulic retention time to the liquid component indicated a stable digestion efficiency even after 15 days of hydraulic retention time.In the experiments conducted on food waste, the digestion efficiency at $55^{\circ}C$ was higher than that at $35^{\circ}C$. When the food waste, especially the liquid component originating from food waste, is treated by anaerobic digestion method, the mesophilic temperature and thermophilic temperature conditions are more favorable in the digestion efficiency than the middle high temperature ($45^{\circ}C$). However, when applying thermophilic or mesophilic temperature anaerobic digestion process operation in the field, the amount of energy input should be considered.

The Use of the Online Two-dimensional Liquid Chromatography Coupled with a Universal Detector for the Screening of Non-volatile Potential Migrants in Food Packaging Materials (식품포장재내 비휘발성 잠재 이행물질들의 스크리닝을 위한 이차원크로마토 그래피와 범용검출기의 이용)

  • Yoon, Chan-Suk;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.16 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • For screening test of the non-volatile compounds which migrate from food packaging materials into foodstuffs, the traditional high performance liquid chromatography (HPLC) systems suffer from the lack of universal detector with high sensitivity and universality and high efficiency HPLC separation column which provides complete separation of complex mixtures into all individual substances. In this work, the use possibility of online two-dimensional liquid chromatography (2D-LC) system coupled with a charged aerosol detector (CAD), a universal detector, was reviewed. 2D-LC system permits to improve peak capacity and resolving power for complex mixtures. Charged aerosol detector (CAD) offers a new feasibility for detection of any non-volatile compounds with high sensitivity and constant response factor in a calibration range. The combination of size exclusion chromatography (SEC) and normal phase HPLC (NP-HPLC) is most frequently used for the separation of the natural and synthetic polymers which are mainly used as raw materials for the manufacture of food packaging materials. However, there is no commercial software available for data acquisition and handling and therefore the quantification in 2D-LC analysis is still rare.

  • PDF

Liquid Chromatographic Determination of Etofenprox Residues in Foods with Mass-Spectrometric Confirmation

  • Lee, Young-Deuk;Kwon, Chan-Hyeok;Kwon, Ki-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.4
    • /
    • pp.432-439
    • /
    • 2011
  • BACKGROUND: An official analytical method was developed to determine etofenprox residues in agricultural commodities using high-performance liquid chromatography (HPLC). METHODS AND RESULTS: The etofenprox residue was extracted with acetone from representative samples of five raw products which comprised rice grain, apple, mandarin, cabbage, and soybean. The extract was then serially purified by liquid-liquid partition and Florisil column chromatography. For rice and soybean samples, acetonitrile/n-hexane partition was additionally coupled to remove nonpolar lipids. Reversed phase HPLC using an octadecylsilyl column was successfully applied to separate etofenprox from co-extractives. Intact etofenprox was sensitively detected by ultraviolet absorption at 225 nm. Recovery experiment at the quantitation limit validated that the proposed method could apparently determine the etofenprox residue at 0.02 mg/kg. Mean recoveries from five crop samples fortified at three levels in triplicate were in the range of 93.6~106.4%. Relative standard deviations of the analytical method were all less than 10%, irrespective of crop types. A selected-ion monitoring LC/mass spectrometry with positive atmospheric-pressure chemical ionization was also provided to confirm the suspected residue. CONCLUSION(s): The proposed method is simple, rapid and sensitive enough to be employed in routine inspection or monitoring of agricultural products for the etofenprox residue.

Storage Stability of Seasoned-Dried Pacific Saury (Imported Product) Treated with Liquid Smoke

  • Cha, Yong-Jun;Park, Sung-Young;Cho, Woo-Jin;Lee, Young-Mi;Kim, Hyounjin;Kim, Jin-Soo
    • Preventive Nutrition and Food Science
    • /
    • v.6 no.4
    • /
    • pp.235-239
    • /
    • 2001
  • In order to enhance suitable processing methods of imported Pacific saury, Cololabis saira, storage stability of seasoned-dried Pacific saury (imported product) treated with liquid smoke (T2 product) was compared with a control (C, seasoning only) and T1 (treatment of 0.05% BHT instead of liquid smoke). The histamine contents of 3 seasoned-dried products were within a stable range (9.08 ~ 12.08 mg/100 g) during storage. The water activities of all products were in the 0.698 ~ 0.755 range. The viable cell count of T2 was lower than those of C and T1 during storage. The change in color values of C, T1 and T2 were not significant with increasing storage period. The results of the sensory evaluation during storage showed that the shelf-life of T2 was extended to 60 days, while those of C and T1 were limited to up to 45 days.

  • PDF

Real-Time Measurement of the Liquid Amount in Cryo-Electron Microscopy Grids Using Laser Diffraction of Regular 2-D Holes of the Grids

  • Ahn, Jinsook;Lee, Dukwon;Jo, Inseong;Jeong, Hyeongseop;Hyun, Jae-Kyung;Woo, Jae-Sung;Choi, Sang-Ho;Ha, Nam-Chul
    • Molecules and Cells
    • /
    • v.43 no.3
    • /
    • pp.298-303
    • /
    • 2020
  • Cryo-electron microscopy (cryo-EM) is now the first choice to determine the high-resolution structures of huge protein complexes. Grids with two-dimensional arrays of holes covered with a carbon film are typically used in cryo-EM. Although semi-automatic plungers are available, notable trial-and-error is still required to obtain a suitable grid specimen. Herein, we introduce a new method to obtain thin ice specimens using real-time measurement of the liquid amounts in cryo-EM grids. The grids for cryo-EM strongly diffracted laser light, and the diffraction intensity of each spot was measurable in real-time. The measured diffraction patterns represented the states of the liquid in the holes due to the curvature of the liquid around them. Using the diffraction patterns, the optimal time point for freezing the grids for cryo-EM was obtained in real-time. This development will help researchers rapidly determine high-resolution protein structures using the limited resource of cryo-EM instrument access.