• 제목/요약/키워드: liquid column

검색결과 1,372건 처리시간 0.026초

Reformate 분리공정에서의 열복합 증류탑 제어구조에 관한 연구 (Study on Control Efficiency of Thermally Coupled Distillation Column for Reformate Fractionation Process)

  • 이주영
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3774-3778
    • /
    • 2012
  • Reformate 분리 공정에 대한 열복합 증류탑의 가능한 제어 구조를 조사하고 그 제어 성능을 검토하기 위하여 동적 모사를 수행하였다. Aspen HYSYS를 사용하여 $3{\times}3$ 제어구조를 적용하여 여러 가지 제어구조로 동적 모사한 결과 Reformate 분리 공정 주탑의 상부, 중간, 하부 제품 조성은 각각 reflux flow rate, 주탑에서 전처리탑 상부로 흐르는 liquid draw rate, vapor boilup rate로 제어되는 구조가 가장 운전 안정성이 확보됨을 확인하였다.

UHPLC 시스템 종료 및 재가동 시 가이드 (UHPLC System Shutdown and Reactivation Advice)

  • Mark Fever;Gemma Lo
    • FOCUS: LIFE SCIENCE
    • /
    • 제1호
    • /
    • pp.8.1-8.3
    • /
    • 2024
  • Ultra-high performance liquid chromatography (UHPLC) systems are integral to modern analytical laboratories, necessitating careful maintenance and operation protocols to ensure optimal performance. This document provides comprehensive guidelines for the proper shutdown and reactivation of UHPLC systems to prevent damage and maintain operational efficiency. • Shutdown: Remove the column and replace it with a union to avoid blockages. Flush the system with a compatible solvent mix, clean mobile phase reservoirs to prevent microbial growth, flush the pump with storage solvent, and clean the autosampler, including the needle and injection port. • Reactivation: Inspect the system for wear or damage, gradually reintroduce mobile phases starting with a weak solvent, reinstall the column securely, and perform system checks on baseline stability, pressure consistency, and detector performance. By adhering to these guidelines, laboratories can ensure the longevity and reliability of their UHPLC systems, maintaining high analytical performance and minimizing downtime. These procedures help prevent common issues such as blockages, contamination, and component wear, thereby supporting efficient and accurate analytical operations.

  • PDF

Optimum LCVA for suppressing harmonic vibration of damped structures

  • Shum, K.M.;Xu, Y.L.;Leung, H.Y.
    • Smart Structures and Systems
    • /
    • 제20권4호
    • /
    • pp.461-472
    • /
    • 2017
  • Explicit design formulae of liquid column vibration absorber (LCVA) for suppressing harmonic vibration of structures with small inherent structural damping are developed in this study. The developed design formulae are also applicable to the design of a tuned mass damper (TMD) and a tuned liquid column damper (TLCD) for damped structures under harmonic force excitation. The optimum parameters of LCVA for suppressing harmonic vibration of undamped structures are first derived. Numerical searching of the optimum parameters of tuned vibration absorber system for suppressing harmonic vibration of damped structure is conducted. Explicit formulae for these optimum parameters are then obtained by a series of curve fitting techniques. The analytical result shows that the control performance of TLCD for reducing harmonic vibration of undamped structure is always better than that of non-uniform LCVA for same mass and length ratios. As for the effects of structural damping on the optimum parameters, it is found that the optimum tuning ratio decreases and the optimum damping ratio increases as the structural damping is increased. Furthermore, the optimum head loss coefficient is inversely proportional to the amplitude of excitation force and increases as the structural damping is increased. Numerical verification of the developed explicit design expressions is also conducted and the developed expressions are demonstrated to be reasonably accurate for design purposes.

기포탑 유동에서의 기포분율과 혼합정도의 상관관계 (Relationship between void fraction and mixing in bubble column flow)

  • ;이주범;박형민
    • 한국가시화정보학회지
    • /
    • 제15권1호
    • /
    • pp.41-46
    • /
    • 2017
  • Control of mixing and transport processes are the key areas that can be benefited by understanding the hydrodynamics in gas-liquid two-phase flows. In particular, the enhanced bubble-induced liquid-phase mixing is known to be a function of void fraction distribution, gas phase velocity and so on. To further our insight on the characteristics of the liquid-phase mixing induced by the bubbles, in the present study, we experimentally investigate the mixing performance of a rectangular bubble column while changing the void fraction from 0.006 to 0.075%. A shadowgraphy technique is used to measure the gas-phase properties such as void fraction and size/velocity of bubbles. On the other hand, we use dye visualization with low diffusive buoyant dye to directly measure the level of mixing. Finally, we confirm that the time taken for full mixing scales with the inverse of volume void fraction.

파력발전용 가변수주진동장치의 운동에 대한 실험적 연구 (2. 다수 부유체) (Experimental study on motions of VLCO for wave power generation (2. Multiple floating bodies))

  • 이승철;구자삼
    • 한국해양공학회지
    • /
    • 제27권6호
    • /
    • pp.27-31
    • /
    • 2013
  • The structure of a variable liquid column oscillator(VLCO) is analogous to that of the tuned liquid column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. The VLCO is a system for absorbing the high kinetic energy of the accelerated motions of multiple floating bodies using an air-spring effect produced the installation of inner air chambers. Thus, a VLCO can improve the energy efficiency of the activating object type of wave energy converters made by the Pelamis Company. In this research, an experiment was performed in two cases: with the top valves closed and open. The floating bodies were connected by hinges. The effect of the internal flow was estimated by comparing the results for the closed and open valves.

Free vibration analysis of steel liquid storage tank with functionally graded column based on modified continuum mechanics

  • Cavus, Yakup Harun;Kupeli, Togay;Yayli, Mustafa Ozgur
    • Coupled systems mechanics
    • /
    • 제11권4호
    • /
    • pp.335-355
    • /
    • 2022
  • It's important to note that the number of studies on the lateral vibration of steel liquid storage tanks has been quite modest in the past. The aim of this research has to look at the variables that affect vibration of storage tanks and to highlight the characteristics of a construction that hasn't received much attention in the literature. The storage tank has pre-sized in the study, and aluminum and steel have chosen as components. The specified material qualities and the factors utilized in the investigation has used to calculate vibration frequency values. The resulting calculations are backed up by tables and graphs, and it's an important to look into the parameters that affect the vibration frequencies that will occur on the designed storage tank vary. In the literature, water tanks are usually modelled as lumped masses. The horizontal stiffness of the column on which it is placed is assumed to be constant throughout. This is an approximation method of solving this problem. The column is handled in this study with a more realistic approach that fits the continuum mechanics in the analysis. The reservoir part is incorporated directly into the problem as the boundary condition.

역상 크로마토그래피에서 다당유도체로 공유결합된 키랄 컬럼을 이용한 거울상 이성질체의 광학분리 (Enantiomer separation using a covalently immobilized chiral column derived from polysaccharide derivative by reversed phase liquid chromatography)

  • 황호;김경옥;백채선;이원재
    • 분석과학
    • /
    • 제22권2호
    • /
    • pp.148-151
    • /
    • 2009
  • 역상 액체 크로마토그래피에서 다당유도체 선택자가 공유결합된 키랄 컬럼인 Chiralpak IB을 사용하여 N-FMOC $\alpha$-amino acid의 광학 이성질체의 분리를 수행하였다. 공유결합된 키랄 컬럼인 Chiralpak IB에서 여러 역상 이동상 조건들이 광학분할의 선택성과 분리인자, 머무름시간에 미치는 영향을 보여주었다. 또한 역상 액체 크로마토그래피에서 N-FMOC $\alpha$-amino acid의 광학 이성질체의 분리 결과를 순상 액체 크로마토그래피 결과와 비교하였는데 순상이동상을 사용한 것보다는 대체적으로 낮은 광학분할을 보여주었다.

Column-Switching System을 이용한 우유속의 D-아미노산의 미량정량 (Micro-Determination of D-Amino Acids in Milk by using Column Switching System)

  • 이선행;김경희;이영철;김상태
    • 대한화학회지
    • /
    • 제39권4호
    • /
    • pp.257-265
    • /
    • 1995
  • 시중에 시판되고 있는 우유를 전처리하여 이 우유에 포함된 유리 아미노산을 dansyl-chloride로 유도체화시켜 C-18 컬럼을 이용한 역상 LC법으로 분리한 다음 표준물 첨가법으로 정량했다. 미량의 D-아미노산의 분리에서는 LC의 Column-Switching System을 이용하였으며 비키랄 컬럼을 통과한 단실 D/L-아미노산에 $Cu(N-benzyl-L-proline)_2$를 이동상에 첨가한 키랄 분리를 수행하여 L-아미노산에서 D-아미노산을 분리 정량했다. 이 방법은 우유시료 중에 존재하는 16가지 아미노산의 정량이 가능하며 이중에 12가지의 D-아미노산이 column switching 방법을 통한 키랄 분리로 정량이 가능하다. 우유 100 mL에 총 유리 아미노선이 41.00 mg 포함되어 있음을 확인했으며, D-아미노산은 D-glutamic acid가 2.05%, D-alanine 2.93%만이 포함되어 있음을 확인했다.

  • PDF

High Performance Liquid Chromatographic Analysis of a New Proton Pump Inhibitor KR60436 and Its Active Metabolite O-Demethyl-KR60436 in Rat Plasma Samples Using Column-Switching

  • Lee, Hyun-Mee;Lee, Hee-Yong;Choi, Joong-Kwon;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • 제24권3호
    • /
    • pp.207-210
    • /
    • 2001
  • A fully automated high performance liquid chromatography with column-switching was developed for the simultaneous determination of KR60436, a new reversible proton pump inhibitor, and its active metabolite O-Demethyl-KR60436 from rat plasma samples. Plasma sample (50$\mu$l) was directly introduced onto a Capcell Pak MF Ph-1 column ($10{\times}4$ mm I.D.) where primary separation was occurred to remove proteins and concentrate target Substances Using acetonitrile-Potassium Phosphate (PH 7, 0.1 M) (2 : 8, v/v). The drug molecules eluted from MF Ph-1 column were focused in an intermediate column ($10{\times}2$ I.D.) by the valve switching step. The substances enriched in intermediate column were eluted and separated on a Vydac 218MR53 column ($250{\times}3.2$ I.D.) using acetonitrilepotassium phosphate (pH 7, 0.02 M) (47:53, v/v) at a flow rate of 0.5 ml/min when the valve status was switched back to A position. The method showed excellent sensitivity (detection limit of 2 ng/ml) with small volume of samples ($50{\mu}$l), good precision and accuracy, and speed (total analysis time 24 min) without any loss in chromatographic efficiency. The response was linear ($r^2{\geq}0.797$) over the concentration range of 5-500 ng/ml.

  • PDF

Identification of Nandrolone and its Metabolite 5α-Estran-3β, 17α-Diol in Horse Urine after Chemical Derivatization by Liquid Chromatography Tandem Mass Spectrometry

  • Dubey, Saurabh;Beotra, Alka
    • Mass Spectrometry Letters
    • /
    • 제8권4호
    • /
    • pp.90-97
    • /
    • 2017
  • Androgenic anabolic steroids (AASs) are synthetic derivatives of testosterone with a common structure containing cyclopentanoperhydrophenanthrene nucleus. Their use enhances the muscle building capacity and is beneficial during performance. The AASs are one of the most abused group of substances in horse doping. Liquid chromatography tandem mass spectrometry ($LC/MS^n$) has been successfully applied to the detection of anabolic steroids in biological samples. However, the saturated hydroxysteroids viz: nandrolone, $5{\alpha}-estrane-3{\beta}$, $17{\alpha}-diol$ exhibit lower detection responses in electrospray ionisation (ESI) because of their poor ionisation efficiency. To overcome this limitation pre-column chemical derivatization has been introduced to enhance their detection responses in $LC-ESI-MS^n$ analysis. The aim of present study was to develop a sensitive method for identification and confirmation of nandrolone and its metabolite in horse urine incorporating pre-column derivatization using picolinic acid. The method consists of extraction of targeted steroid conjugates by solid phase extraction (SPE). The eluted steroid conjugates were hydrolysed by methanolysis and free steroids were recovered with liquid-liquid extraction. The resulting steroids were derivatized to form picolinoyl esters and identification was done using LC-ESI-MS/MS in positive ionization mode. The picolinated steroid adduct enhanced the detection levels in comparison to underivatized steroids.