• Title/Summary/Keyword: liquid column

Search Result 1,369, Processing Time 0.029 seconds

Innovative modeling of tuned liquid column damper controlled structures

  • Di Matteo, Alberto;Di Paola, Mario;Pirrotta, Antonina
    • Smart Structures and Systems
    • /
    • v.18 no.1
    • /
    • pp.117-138
    • /
    • 2016
  • In this paper a different formulation for the response of structural systems controlled by Tuned Liquid Column Damper (TLCD) devices is developed, based on the mathematical tool of fractional calculus. Although the increasing use of these devices for structural vibration control, it has been demonstrated that existing model may lead to inaccurate prediction of liquid motion, thus reflecting in a possible imprecise description of the structural response. For this reason the recently proposed fractional formulation introduced to model liquid displacements in TLCD devices, is here extended to deal with TLCD controlled structures under base excitations. As demonstrated through an extensive experimental analysis, the proposed model can accurately capture structural responses both in time and in frequency domain. Further, the proposed fractional formulation is linear, hence making identification of the involved parameters extremely easier.

Passive control of seismically excited structures by the liquid column vibration absorber

  • Konar, Tanmoy;Ghosh, Aparna Dey
    • Structural Engineering and Mechanics
    • /
    • v.36 no.5
    • /
    • pp.561-573
    • /
    • 2010
  • The potential of the liquid column vibration absorber (LCVA) as a seismic vibration control device for structures has been explored in this paper. In this work, the structure has been modeled as a linear, viscously damped single-degree-of-freedom (SDOF) system. The governing differential equations of motion for the damper liquid and for the coupled structure-LCVA system have been derived from dynamic equilibrium. The nonlinear orifice damping in the LCVA has been linearized by a stochastic equivalent linearization technique. A transfer function formulation for the structure-LCVA system has been presented. The design parameters of the LCVA have been identified and by applying the transfer function formulation the optimum combination of these parameters has been determined to obtain the most efficient control performance of the LCVA in terms of the reduction in the root-mean-square (r.m.s.) displacement response of the structure. The study has been carried out for an example structure subjected to base input characterized by a white noise power spectral density function (PSDF). The sensitivity of the performance of the LCVA to the coefficient of head loss and to the tuning ratio have also been examined and compared with that of the liquid column damper (LCD). Finally, a simulation study has been carried out with a recorded accelerogram, to demonstrate the effectiveness of the LCVA.

Narrowbore high-performance liquid chromatographic method for the determination of cetirizine in plasma using column switching

  • Hyun, Myung-Ja;Ban, Eunmi;Woo, Jong-Soo;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.398.2-398.2
    • /
    • 2002
  • A column switching HPLC assay was developed to allow the separation and quantitation of cetirizine in human plasma by ultraviolet (UV) detection. Plasma samples were prepared by liquid-liquid extraction. After drying, the residue was reconstituted in 20 mM phosphate buffer (pH 2.8) containing 15% acetonitrile. The samples were initially injected onto a clean-up Capcell Pak MF C18 column. (50 mm $\times$ 4.6 mm I.D.), and the chromatographic region containing the peaks of interest was followed in an analytical C18 microcolumn (250 mm$\times$1.5 mm I. D.) via column switching device. (omitted)

  • PDF

Separation Characteristics of IgY (Immunoglobulin Yolk) in Various HPLC Columns (다양한 HPLC Column에서의 IgY(Immunoglobulin Yolk) 분리특성)

  • Song, Sung Moon;Kim, In Ho
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.659-665
    • /
    • 2012
  • IgY (Immunoglobulin Yolk) in egg yolk corresponds to IgG (Immunoglobulin G) in animal serum and plays an important role as immunological proteins in intestines. Carrageenan and Arabic gum were used as pretreatment agents to purify IgY from fresh egg yolk. DEAE (Diethylaminoethyl) Sepharose column in FPLC (Fast Protein Liquid chromatography) was an ion exchange tool to remove contaminants as well as to elute IgY from the column. GF HPLC (Gel Filtration High Performance Liquid Chromatography) enables to measure the molecular weights of IgY and to identify the purified IgY by comparing the molecular weight of standard IgY with the purified one. IgY is a heterogeneous group of different molecular weight and ionic properties, which was investigated with various IE HPLC (Ion Exchange High Performance Liquid Chromatography) columns such as AX, CX and SCX. Three peaks of IgY were separated in the AX column under the conditions of 0.5 M NaCl and pH=8. The SCX column also gave the three peaks of IgY at 0.5 M NaCl and pH=5.

Buffeting response control of a long span cable-stayed bridge during construction using semi-active tuned liquid column dampers

  • Shum, K.M.;Xu, Y.L.;Guo, W.H.
    • Wind and Structures
    • /
    • v.9 no.4
    • /
    • pp.271-296
    • /
    • 2006
  • The frequency of a traditional tuned liquid column damper (TLCD) depends solely on the length of liquid column, which imposes certain restrictions on its application to long span cable-stayed bridges during construction. The configuration of a cable-stayed bridge varies from different construction stages and so do its natural frequencies. It is thus difficult to apply TLCD with a fixed configuration to the bridge during construction or it is not economical to design a series of TLCD with different liquid lengths to suit for various construction stages. Semi-active tuned liquid column damper (SATLCD) with adaptive frequency tuning capacity is studied in this paper for buffeting response control of a long span cable-stayed bridge during construction. The frequency of SATLCD can be adjusted by active control of air pressures inside the air chamber at the two ends of the container. The performance of SATLCD for suppressing combined lateral and torsional vibration of a real long span cable-stayed bridge during construction stage is numerically investigated using a finite element-based approach. The finite element model of SATLCD is also developed and incorporated into the finite element model of the bridge for predicting buffeting response of the coupled SATLCD-bridge system in the time domain. The investigations show that with a fixed container configuration, the SATLCD with adaptive frequency tuning can effectively reduce buffeting response of the bridge during various construction stages.

Effects of Orifice Internal Flow on Transverse Injection into Subsonic Crossflows (아음속 유동장에 수직분사시 오리피스 내부유동 효과에 대한 연구)

  • 김정훈;안규복;윤영빈
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.1
    • /
    • pp.28-39
    • /
    • 2003
  • Effects of the orifice internal flow such as cavitation and hydraulic flip on transverse injection into subsonic crossflows have been studied. The liquid column breakup length and the liquid column trajectory were measured by changing the orifice diameter (d), the orifice length/orifice diameter (L/d), the injection pressure and the shapes (sharp and round) of orifice entrance, and were compared with previous results. It is found that cavitation bubbles, which occur inside the sharp-edged orifice, make the liquid jet very turbulent and especially in the orifices with L/d = 5 hydraulic flip appear as cavitation bubbles are emitted from the orifice. The breakup length is shorter as cavitation bubbles grows and hydraulic flip appears. However, the liquid column trajectories normalized by the effective diameter and the effective momentum ratio have a similar tendency irrespective of cavitation and hydraulic flip.

Separation of Burnup Monitors in Spent Nuclear Fuel Samples by Liquid Chromatography

  • Joe, Kih-Soo;Jeon, Young-Shin;Kim, Jung-Suck;Han, Sun-Ho;Kim, Jong-Gu;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.4
    • /
    • pp.569-574
    • /
    • 2005
  • A coupled column liquid chromatography system was applied for the separation of the burnup monitors in spent nuclear fuel sample solutions. A reversed phase column was studied for the adsorption behavior of uranyl ions using alpha-hydroxyisobutyric acid as an eluent and used for the separation of plutonium and uranium. A cation exchange column prepared by coating 1-eicosylsulfate onto the reversed phase column was used for the separation of the lanthanides. In addition, retention of Np was checked with the reversed phase column and cation exchange column, respectively, according to the oxidation states to observe the interference effect for the separation of burnup monitors. This chromatography system showed a great reduction in separation time compared to a conventional anion exchange method. A good agreement from the burnup data was obtained between for this method and a conventional anion exchange method to within 1% of a difference for the spent nuclear fuel samples of about 40 GWD/MTU.

Isolation of ginsenosides Rb1, Rb2, Rc Rd, Re, Rf and Rg1 from cinseng root by high performance liquid chromatography

  • Paik, Nam-Ho;Park, Man-Ki;Choi, Kang-Ju;Cho, Yung-Hyun
    • Archives of Pharmacal Research
    • /
    • v.5 no.1
    • /
    • pp.7-12
    • /
    • 1982
  • Ginsenosides Rb1, Rb2, Rc, Rd, Re, Rf and Rg1 were effectively isolated from ginseng root by preparative liquid chromatography (LC) on two PrepPAK-500/c18 cartridges in series and semipreparative LC on a .mu. Bondapak cabohydrate analysis column, a .mu.Bondapak C18 column or a .mu. Porasil column. The identities of the isolated ginsenosides were confirmed by analytical high-performance liquid chromatography (HPLC) and infrared spectrophotometry. By this method large scale isolation of pure ginsenosides was efficiently accomplished.

  • PDF

Experimental study of the surface-tension driven flow in a cylindrical liquid column (원통형 액적내의 표면장력 변화로 인한 흐름특성에 관한 실험적 연구)

  • 이진호;강희찬;이동진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.4
    • /
    • pp.629-636
    • /
    • 1987
  • An experiment is carried out to study the surface-tension driven flow characteristics in a cylindrical liquid column heated from above (which is the low gravity floating zone simulated on earth) with varing the aspect ratio and diameter of the liquid column. Hexadecane, octadecane, silicon oil(10cs), FC-40 and water are used as the test liquids. The free surface shape varies sinusoidally for Ma>M $a_{cr}$ and its frequency is found to be the same as that of temperature oscillation. It is verified that the surface temperature profile changes from linear to S-shaped profile for Ma>M $a_{cr}$ . The frequency of temperature oscillation decreases with increasing liquid volume, while its level increases. M $a_{cr}$ decreases with increasing aspect ratio, and also decreases with increasing Prandtl number in the range of 25