• Title/Summary/Keyword: liquid analyzer

Search Result 212, Processing Time 0.027 seconds

Studies on the Deodorization in the Nightsoil Treatment Plant with liquid Phase Catalytic Oxidation Method by Utilization of Fe-EDTA (Fe-EDTA계 액상촉매 산화법에 의한 분뇨처리장 악취제거에 관한 연구)

  • 이인화
    • Journal of Environmental Science International
    • /
    • v.1 no.2
    • /
    • pp.105.1-113
    • /
    • 1992
  • The present study was performed to develop the removal system of the offensive gases, including hydrogen sulfide of acid gas, ammonia or amice of base gas, from the nightsoil treatment plant. In order to remove the offensive gases, the Fe-EDTA system liquid phase catalytic oxidation method with the bubble lift column reactor was employed. From the results obtained, it was confirmed that the offensive gases can be deodorized simultaneously and also hydrogen sulfide of acid gas, ammonia of base gas completely removed at pH 6.45. In addition, as input gases feed rate the efficiency of acid gas did not change but the efficiency of base gases decreased to approximately 90 % at pH 6, 0. From the result of particle size analyzer, it was found that the particle sizes including sulfur and other impurites grew up to $21{\mu}m$ over 72hour reaction time.

  • PDF

Sintering Behavior of 2xxx Series Al alloys with Variation of Sintering Temperature (2xxx Al 합금계 혼합분말의 소결온도에 따른 소결거동)

  • 민경호;김대건;장시영;임태환;김영도
    • Journal of Powder Materials
    • /
    • v.10 no.1
    • /
    • pp.40-45
    • /
    • 2003
  • Sintering behavior of 2xxx series Al alloy was investigated to obtain full densification and sound microstructure. The commercial 2xxx series Al alloy powder. AMB2712, was used as a starting powder. The mixing powder was characterized by using particle size analyzer, SEM and XRD. The optimum compacting pressure was 200 MPa, which was the starting point of the "homogeneous deformation" stage. The powder compacts were sintered at $550~630^{\circ}C$ after burn-off process at $400^{\circ}C$. Swelling phenomenon caused by transient liquid phase sintering was observed below $590^{\circ}C$ of sintering temperature. At $610^{\circ}C$, sintering density was increased by effect of remained liquid phase. Further densification was not observed above $610^{\circ}C$. Therefore, it was determined that the optimum sintering temperature of AMB2712 powder was $610^{\circ}C$.}C$.

The Characteristics of Frequency Spectrum of Radiated Electromagnetic Waves with AC Discharge Progress in Liquid Nitrogen (액체 질소중 교류방전 진전에 따른 방사전자파의 주파수 스펙트럼 특성)

  • 박광서;윤대희;이상훈;이현동;김충년;최병주;김기채;이광식
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.3
    • /
    • pp.123-129
    • /
    • 2003
  • In this paper, a relationship between AC discharge progress and the radiated electromagnetic waves was investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The frequency spectrum of the radiated electromagnetic waves were measured at the atmospheric pressure in liquid nitrogen($LN_2$) during partial discharges progressed by AC high voltage in nonuniform electric field. Front the results of this study, a new method was introduced for measurement and analysis of the radiated electromagnetic waves with discharge progress in $LN_2$ Besides. according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress could be possible. It is considered that these results obtained from this investigation may be used as fundamental data for diagnosis and prediction of electric insulations about superconducting and cryogenic power equipments.

Study of variables influencing on the metal transfer in GMAW (GMAW의 금속이행에 영향을 주는 변수연구를 위한 계측 시스템과 조건해석)

  • 이세헌
    • Journal of Welding and Joining
    • /
    • v.11 no.1
    • /
    • pp.73-79
    • /
    • 1993
  • The phenomenon of metal transfer has been investigated for different transfer modes using a digital high speed motion analyzer and an arc shadow-graphing system based on a laser source and related optical system. It was observed that the pinch instability phenomenon did not occur for the globular transfer mode, since the liquid globule was then spherical rateher than a cylindrical liquid bar. On increasing the ratio of carbon dioxide to argon, the transition current from globular to spray transfer generally increased, but it is interesting that the transition was observed to occur at the lowest current in a 5% CO$_{2}$-95% argon gas mixture. For pure carbon dioxide and helium shielding gases, the drop frequency increased slowly with increasing current. At high currents or an argon based shielding gas, the length of liquid bar decreased as the carbon dioxide content increased. The acceleration of a droplet within the arc was determined using the gas drag force theory and was found to be greater than the experimental results.

  • PDF

Estimation of heat release rate of liquid fuels by Oxygen consumption technique (산소 소모법에 의한 액체 연료의 열발생율 평가)

  • 한용식;김명배;최준석
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.31-37
    • /
    • 1998
  • The heat release rate of liquid fuels is estimated by oxygen consumption technique. This method is based on the generalization that the heat release rate of combustion per unit of oxygen consumed are approximately the same for most fuels commonly encountered in fires. The oxygen concentration is measured by analyzer of paramagnetic type. The concentrations of CO2 and CO gas are measured by analyzed of Infra-Rad type. Time delays of analyzers are ignored. Results acqired from measuring techniques of exhaust gas concentrations are compared with each other.

  • PDF

Characterization of Ionic Liquid Contained Polymer Gel Electrolyte (이온성 액체를 함유한 고분자 겔 전해질의 특성연구)

  • Ryu, Sang-Woog;Song, Eui-Hwan
    • Polymer(Korea)
    • /
    • v.32 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • Acrylate polymer gel electrolytes containing N-methoxymethyl-N-methylpyrrolidium bis (trifluoro - methansulfonyl) imide (MPSI) as an ionic liquid were synthesized by solution polymerization in the presence of carbonate solvent. ionic conductivity and mechanical properties of the polymer gel electrolytes were investigated by impedance analyzer and universal testing machine as a function of the amount of polymer, and ionic liquid and type of crosslinker. The maximum ionic conductivity of polymer gel electrolytes was 0.8 mS/cm at $25^{\circ}C$ with 15 wt% of polymer, 30 wt% of ionic liquid and 5 wt% of crosslinker. The mechanical analysis showed that the tensile strength of polymer gel electrolytes increased with additional polymer contents and had the maximum value of 0.5 MPa with a reasonable ionic conductivity.

Factors influencing the penetration kinetics of PVAm solution in z-direction of paper (PVAm 용액 종이 두께 방향 침투 kinetics에 영향하는 인자들)

  • Cho, Byoung-Uk;Won, Jong-Myoung;Moon, Eun-Sik;Choi, Do-Chim
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2011.04a
    • /
    • pp.31-35
    • /
    • 2011
  • Factors influencing penetration kinetics of PVAm solution into paper were investigated with ultrasonic Penetration Evenness Analyzer (PEA). Paper structure was varied by changing basis weight, freeness of pulp, calendering, number of plies and filler addition and hydrophobicity of paper was varied by adding AKD. Important factors affecting liquid penetration are found to be pore structure and hydrophobicity of paper. Pore structure of paper can be designed by controlling refining degree and filler addition. Hydrophobicity of paper can be controlled by internal sizing.

  • PDF

Spectrum Analyzer를 통한 미세 방전 플라즈마 밀도측정

  • Jo, Tae-Hun;Yun, Myeong-Su;Park, In-Gyu;Yu, Ha-Jin;Choe, Eun-Ha;Jo, Gwang-Seop;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.136-136
    • /
    • 2010
  • 일반적인 플라즈마의 밀도측정에는 랑뮤어(Langmuir)탐침법이 보편적으로 사용되고 있다. 그러나 LCD(Liquid Crystal Display)나 PDP(Plasma Display Panel) 등 미세 방전 플라즈마는 이러한 방법으로는 측정이 너무 어려워서 잘 사용되지 않고 있다. 그래서 이러한 경우 간접측정 방법이 사용되고 있다. 본 연구에서는 알려진 간접 측정방법과는 다른 방식인 spectrum analyzer를 사용하여 측정해 보았다. LCD에서 사용되는 BLU(Back Light Unit)lamp와 PDP panel을 각각 측정하여 기존의 간접측정 방법의 결과와 비교해 보았다.

  • PDF

Disintegration Process of the Rotating Fuel Injector (회전연료 분사시스템의 분열과정)

  • Jang, Seong-Ho;Lee, Dong-Hun;You, Gyung-Won;Choi, Seong-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.171-174
    • /
    • 2008
  • This paper presents disintegration process of the small rotational fuel injector. In order to understand disintegration precess, we measured droplet diameter, velocity and spray distribution by the PDPA(Phasse Doppler Particle Analyzer) system. Also spray was visualized by using Nd-Yag flash photography. From the test results, the liquid column emerging from the injection orifice is mainly controlled by the rotational speeds. Furthermore, droplet diameter(SMD) and spray distribution were strongly influenced by the diameter of the injection orifice.

  • PDF

Optimal Design of Liquid Crystal Display Devices Using Electro-optic Characteristics of Liquid Crystal Cell: I. Monochromatic Case (액정셀의 전기광학적 편광투과특성을 이용한 액정표시소자의 최적설계: I. 단색광의 경우)

  • 노봉규;김규석;김진승
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.411-417
    • /
    • 1994
  • The electro-optic polarization transmission characteristics of a liquid crystal (LC) cell is represented by a rotational transformation on the Poincare sphere, and its characteristic parameters, the angle and the axis of the rotation, are experimentally determined with respect to the voltage applied to the LC cell. From the experimental data obtained, we determine driving voltage for the LC cell to give the rotation angle near $180^{\circ}$ of the rotation for the change of the state of the LC cell from non-select to select state, which is a necessary condition for the realization of maximally bright images. The directions of the transmission axes of the polarizer and the analyzer which form a liquid crystal display panel together with the LC cell, are determined from the general characteristics of the rotaional transformation of the LC cell. cell.

  • PDF