• Title/Summary/Keyword: linearity test

Search Result 405, Processing Time 0.023 seconds

Analytical Method Development for Determination of Coenzyme Q10 by LC-MS/MS in Related Health Functional Foods (건강기능식품에서 LC-MS/MS를 이용한 코엔자임Q10 분석법 연구)

  • Lee, Jin Hee;Oh, Mihyune
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.519-525
    • /
    • 2019
  • The Ministry of Food and Drug Safety (MFDS) is amending its test methods for health functional foods (dietary food supplements) to establish regulatory standards and specifications in Korea. In this regard, we are continuing our research on analytical method development for the items listed in the Korean Health Functional Food Codex. In this study, we have developed a sensitive and selective test method that could simultaneously separate and determine coenzyme Q10 based on liquid chromatographic-tandem mass spectrometry (LC-MS/MS). Calibration curves showed linearity with a correlation coefficient (R2) of > 0.999 and the limits of detection (LODs) and limits of quantitation (LOQs) were in the range of 26.0 ㎍/L and 78.9 ㎍/L, respectively. The recovery results ranged between 98.6-107.0% at 3 different concentration levels with relative standard deviations (RSDs) less than 5%. The proposed analytical method was characterized with high resolution of the coenzyme Q10 and the assay was fully validated as well.

Similitude Law on Material Non-linearity for Seismic Performance Evaluation of RC Columns (RC기둥의 내진성능평가를 위한 재료비선형 상사법칙)

  • Lee, Do-Keun;Cho, Jae-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.409-417
    • /
    • 2010
  • This paper discusses a series of experiments including material improvement in order to ensure quality of grouting for the post-tensioned structure. In prestressed concrete, grouting refers to the construction procedure of filling empty space of duct enclosing with strands using cementitious material, To date, adequate quality control of the grouting has not been established in Korea because the relationship between the grouting and durability of post-tensioned structure is not well-recognized. The Korean standard does not consider the important material characteristic, wick effect, which is caused by strands in the ducts and current standard testing method unlikely quantify reasonable material segregation. As a result, the grout material, which meets the current material standards, may exhibit excessive bleeding water or shrinkage during construction. In this study, international codes and standards related to grouting were surveyed. The ratio of constituents and novel admixtures were suggested to meet equivalently with these standards. Performance of this enhanced grout was compared to common domestic grout using the international standard testing method. A series of mock-up specimens considering geometry of PC beam was constructed and grout flow pattern was observed as the grout was injected. It was observed that the grouting performance was highly influenced by material properties and filling characteristic can be varied depending on geometry of ducts.

Bioequivalence Study on Two Talniflumate Preparations Commercially Available in Korean (탈리플루메이트 제제에 대한 생물학적동등성 평가)

  • Sohn, Uy-Dong;Jeong, Ji-Hoon;Kim, Kyung-Tae;Cho, Young-Rae;Min, Young-Sil;Song, Hyun-Ju;Je, Hyun-Dong;Yim, Sung-Hyuk;Shin, Yong-Kyoo;Cho, Seong-Wan
    • Korean Journal of Clinical Pharmacy
    • /
    • v.16 no.2
    • /
    • pp.101-106
    • /
    • 2006
  • The aim of the present study was to evaluate the bioequivalence of two talniflumate preparations. We used Somalgen tablet (Kun Wha Pharmaceutical Co., Korea.) as a reference drug for bioequivalence of Crimain tablet (Samjini Pharmaceutical Ind. Co., Korea), and performed this whole study according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty four healthy male volunteers, $22.8{\pm}2.2$ years in age and $64.6{\pm}5.3\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one tablet containing 370 mg of talniflumate was orally administered, blood was taken at predetermined time intervals and the concentrations of talniflumate in plasma were determined using HPLC method with UV-detector. The analysis system was validated in specificity, accuracy, precision and linearity. These items of the analysis condition in this study conform to the guideline of KFDA. The pharmacokinetic parameters such as $AUC_t\;and\;C_{max}$ were calculated using the analysis condition we established and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$ and Cmax. $Mean{\pm}SD$ of reference drug and test drug in $AUC_t\;and\;C_{max}$ value were $1.27{\pm}0.58\;({\mu}g/ml{\cdot}hr)\;and\;0.27{\pm}0.13\;({\mu}g/ml)$ and $1.14{\pm}0.46\;({\mu}g/ml{\cdot}hr)\;and\;0.26{\pm}0.10\;({\mu}g/ml)$ respectively. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log (1.25) for $AUC_t\;and\;C_{max}$, respectively. These results indicate that Samjin talniflumate tablet is bioequivalent to reference drug, Somalgen tablet.

  • PDF

Evaluation of Thermal Degradation of CFRP Flexural Strength at Elevated Temperature (온도 상승에 따른 탄소 복합재의 굽힘 강도 저하 평가)

  • Hwang Tae-Kyung;Park Jae-Beom;Lee Sang-Yun;Kim Hyung-Geun;Park Byung-Yeol;Doh Young-Dae
    • Composites Research
    • /
    • v.18 no.2
    • /
    • pp.20-29
    • /
    • 2005
  • To evaluate the flexural deformation and strength of composite motor case above the glass transition temperature$(T_g),\;170^{\circ}C$, of resin material, a finite element analysis(FEA) model in which material non-linearity and progressive failure mode were considered was proposed. The laminated flexural specimens which have the same lay-up and thickness as the composite motor case were tested by 4-point bending test to verify the validity of FEA model. Also. mechanical properties in high temperature were evaluated to obtain the input values for FEA. Because the material properties related to resin material were highly deteriorated in the temperature range beyond $T_g$, the flexural stiffness and strength of laminated flexural specimen in $200^{\circ}C$ were degraded by also $70\%\;and\;80\%$ in comparison with normal temperature results. Above $T_g$, the failure mode was changed from progressive failure mode initiated by matrix cracking at $90^{\circ}$ ply in bottom side and terminated by delamination at the center line of specimen to fiber compressive breakage mode at top side. From stress analysis, the progressive failure mechanism was well verified and the predicted bending stiffness and strength showed a good agreement with the test results.

Application of RUG-m for Long-Term Care Elderly Patients (RUG-III를 이용한 노인환자군분류의 타당성검증)

  • Yi, Jee-Jeon;Yu, Seung-Hum;Ohrr, Hee-Chul;Nam, Chung-Mo;Park, Eun-Chul;Lee, Yoon-Whan
    • Korea Journal of Hospital Management
    • /
    • v.6 no.3
    • /
    • pp.148-166
    • /
    • 2001
  • The purpose of this study is to classify elderly patient in long-term care facilities using RUG(Resource Utilization Group)-III. It is designed by measuring patient medical characteristics and medical staff time. Elderly patients are classified into 7 categories by clinical(medical and behavioral) hierarchical typology of patients. Through the tertiary split, all 44 groups are formulated. This classification is explained by each patient resource(staff time) utilization level which is called CMI(Case-Mix Index). Major findings are as follows; 1. The objects in this study were classified into 35 groups out of 44 groups. The most frequent category is clinical complex category(CCC; 38.9%). And extensive service category(ESC; 18.8%), reduced physical function category(RPC; 13.1%), special rehabilitation category(SRC; 12.8%), and impaired cognitive category(ICC; 0.00%) are followed. 2. The mean of total CMI was $1.02{\pm}0.36$, ranging from 0.68 to 1.44(1 vs 2.12). The mean of CMI of SRC is only 1.17 which should be the highest. The means of ESC and see are equally 1.20. The means of CMI of CCI, ICC, BPC, and RPC were 0.90, 0.75, 0.83 and 0.96, respectively. 3. The validity of this classification was tested. Trend-test using Regression Analysis was done in the secondary split level. SCC, CCC, ICC, and RPC which covered 68.4% of this research objects showed linear trend of CMI in interim classification. This results were statistically significant. 4. In clinical hierarchy, the trend were showed linearity. But the multiple comparison of categories using Scheffe-test showed that SRC, ESC and see had same level of CMI means and CCC and ICC, too. This results were statistically significant. Classifying elderly patients with RUG-III, the results showed partly linear trend in clinical hierarchy and in interim classification in conclusion. But, in clinical hierarchy, it was failed to show the consistent order of CMI. It can be explained by two reasons. One is that this research subjects were overlapped in each clinical hierarchy group. And the other is that the some of the characteristics for clinical hierarchy is not appropriate for them. For the further study, it needs to have proper sample size and to modify RUG-III to K-RUG to consider our.. medical environment.

  • PDF

I/Q channel 12-Bit 120MHz CMOS D/A Converter for WLAN (무선랜용 I/Q 채널 12bit 120MHz CMOS D/A 변환기 설계)

  • Ha, Sung-Min;Nam, Tae-Kyu;Seo, Sung-Uk;Shin, Sun-Hwa;Joo, Chan-Yang;Yoon, Kwang-S.
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.83-89
    • /
    • 2006
  • This paper describes the design of I/Q channel 12bit Digital-to-Analog Converter(DAC) which shows the conversion rate of 120MHz and the power supply of 3.3V with 0.35um CMOS n-well 1-poly 4-metal process for advanced wireless transceiver. The proposed DAC utilizes 4-bit thermometer decoder with 3 stages for minimum glitch energy and linearity error. Also, using a optimized 4bit thermometer decoder for the decrement of the chip area. Integral nonlinearity(INL) of ${\pm}1.6LSB$ and differential nonlinearity(DNL) of ${\pm}1.3LSB$ have been measured. In single tone test, the ENOB of the proposed 12bit DAC is 10.5bit and SFDR of 73dB(@ Fs=120MHz, Fin=1MHz) is measured, respectively. Dual-tone test SFDR is 61 dB (@ Fs=100MHz, Fin=1.5MHz, 2MHz). Glitch energy of 31 pV.s is measured. The converter consumes a total of 105mW from 3.3-V power supply.

Multiresidue Analysis Method for Determination of Unregistered Organophosphorus Pesticides in Korea for Imported Agri-Food (국내 미등록 유기인계 농약의 수입 농식품에 대한 다성분 잔류분석법)

  • Jeon, Young-Hwan;Hwang, Jeong-In;Ahn, Ji-Woon;Kim, Hyo-Young;Do, Jung-Ah;Oh, Jae-Ho;Hwang, In-Gyun;Im, Moo-Hyeog;Lee, Joong-Keun;Lee, Young-Deuk;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.3
    • /
    • pp.277-285
    • /
    • 2012
  • BACKGROUND: For safety evaluation of imported agri-food in Korea, the multiresidue analysis method was establised for unregistered organophosphorus pesticides, aspon, chlorthion, chlorthiophos, crotoxyphos, demeton-O, demeton-S, demeton-S-methyl, dioxathion, heptenophos, iodofenphos, leptophos, methyl-trithion, propetamphos and sulfotep. METHODS AND RESULTS: The used method for multiresidue analysis in brown rice and orange used as representative samples of imported agri-food was the official method of Korean Food and Drug Administration. The results of validation test of 13 organophosphorus pesticides except crotoxyphos for multiresidue analysis method are compared to the criteria such as specificity, linearity, accuracy, precision and limit of quantification. CONCLUSION: The used method for multiresidue analysis of unregistered 13 organophosphorus pesticides except crotoxyphos in Korea can surely be used as an official method for routine analysis of imported agri-food.

The Study on the Analysis Method of Tetrodotoxin in Puffer Fish (복어 중 테트로도톡신 분석법에 관한 연구)

  • Kang, Young-Woon;Lee, Yoon-Suk;Park, Sung-Kug;Seo, Jung-Heok;Kim, Mee-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.1
    • /
    • pp.37-41
    • /
    • 2012
  • The current standard for testing tetrodotoxin (TTX) in foodstuffs is the mouse bioassay (MBA) in Korea as in many other countries. However, this test suffers from potential ethical concerns over the use of live animals. In addition, the mouse bioassay does not test for a specific toxin thus a sample resulting in mouse incapacitation would need further confirmatory testing to determine the exact source toxin (e.g., TTX, STX, brevotoxin, etc.). Furthermore, though the time of death is proportional to toxicity in this assay, the dynamic range for this proportional relationship is small thus many samples must be diluted and new mice be injected to yield a result that falls within the quantitative dynamic range. Therefore, in recent years, there have been many efforts in this field to develop alternative assays. High performance liquid chromatography (HPLC) coupled with mass spectrometry (MS) has been emerged as one of the most promising options. A LC-MS-MS method involves solid-phase extraction (SPE) and followed by analysis using an electrospray in the positive ionization mode and multiple reactions monitoring (MRM). To adopt LC-MS-MS method as alternative standard for testing TTX, we performed a validation study for the quantification of TTX in puffer fish. This LC-MS-MS method showed good sensitivity as limits of detection (LOD) of $0.03{\sim}0.08{\mu}g/g$ and limits of quantification (LOQ) of $0.10{\sim}0.25{\mu}g/g$. The linearity ($r^2$) of tetrodotoxin were 0.9986~0.9997, the recovery were 80.9~103.0% and the relative standard deviations (RSD) were 4.3~13.0%. The correlation coefficient between the mouse bioassay and LC/MS/MS method was higher than 0.95.

Quality Control System for Analytical Chemistry Laboratory of Pesticide Products (농약 이화학시험 분석기관 정도관리체계)

  • Chang, Hee-Ra;Lee, Joon-Yeob;Lee, Young-Ju;Kang, Hye-Rim;Kim, Chan-Sub;Kim, Kyun
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.529-544
    • /
    • 2011
  • Many international organizations, such as the International Organization for Standardization (ISO) and Collaborative International Pesticide Analytical Council (CIPAC), have published a guide to quality control requirements, proficiency testing and method validation for pesticide formulation. In general, proficiency testing is to determine the performance of individual laboratories from the comparison of test results and to monitor a laboratory's performance abilities. One of quality assurance (QA) scheme would be include the validation of analytical method that implies a performance characteristics, specificity, selectivity, linearity and so on. According to many international organizations, the quantification methods of active substance in formulated pesticide products are required to be reproducible, accurate and precise. This study was conducted to compare the international guidelines for the quality control, proficiency testing and method validation of analytical laboratories and to propose a general guidance for the establishment of quality control system in the analytical chemistry laboratories of pesticide formulation in domestic.

Design and Implement of 50MHz 10 bits DAC based on double step Thermometer Code (50MHz 2단 온도계 디코더 방식을 사용한 10 bit DAC 설계)

  • Jung, Jun-Hee;Kim, Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.6
    • /
    • pp.18-24
    • /
    • 2012
  • This paper reports the test results of a 50MHz/s 10 bits DAC developed with $0.18{\mu}m$ CMOS process for the wireless sensor network application. The 10bits DAC, not likely a typical segmented type, has been designed as a current driving type with double step thermometer decoding architecture in which 10bits are divided into 6bits of MSB and 4bits of LSB. MSB 6bits are converted into 3 bits row thermal codes and 3 bits column thermal codes to control high current cells, and LSB 4 bits are also converted into thermal codes to control the lower current cells. The high and the lower current cells use the same cell size while a bias circuit has been designed to make the amount of lower unit current become 1/16 of high unit current. All thermal codes are synchronized with output latches to prevent glitches on the output signals. The test results show that the DAC consumes 4.3mA DC current with 3.3V DC supply for 2.2Vpp output at 50MHz clock. The linearity characteristics of DAC are the maximum SFDR of 62.02dB, maximum DNL of 0.37 LSB, and maximum INL of 0.67 LSB.