• 제목/요약/키워드: linear resolution

검색결과 750건 처리시간 0.036초

Reconstruction of High-Resolution Facial Image Based on A Recursive Error Back-Projection

  • Park, Joeng-Seon;Lee, Seong-Whan
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2004년도 봄 학술발표논문집 Vol.31 No.1 (B)
    • /
    • pp.715-717
    • /
    • 2004
  • This paper proposes a new reconstruction method of high-resolution facial image from a low-resolution facial image based on a recursive error back-projection of top-down machine learning. A face is represented by a linear combination of prototypes of shape and texture. With the shape and texture information about the pixels in a given low-resolution facial image, we can estimate optimal coefficients for a linear combination of prototypes of shape and those of texture by solving least square minimization. Then high-resolution facial image can be obtained by using the optimal coefficients for linear combination of the high-resolution prototypes, In addition to, a recursive error back-projection is applied to improve the accuracy of synthesized high-resolution facial image. The encouraging results of the proposed method show that our method can be used to improve the performance of the face recognition by applying our method to reconstruct high-resolution facial images from low-resolution one captured at a distance.

  • PDF

THE MINIMAL FREE RESOLUTION OF THE UNION OF TWO LINEAR STAR-CONFIGURATIONS IN ℙ2

  • Shin, Yong-Su
    • 대한수학회논문집
    • /
    • 제31권4호
    • /
    • pp.683-693
    • /
    • 2016
  • In [1], the authors proved that the finite union of linear star-configurations in $\mathbb{P}^2$ has a generic Hilbert function. In this paper, we find the minimal graded free resolution of the union of two linear star-configurations in $\mathbb{P}^2$ of type $s{\times}t$ with $\(^t_2\){\leq}s$ and $3{\leq}t$.

Nanometric Positioning Over a One-Millimeter Stroke Using a Flexure Guide and Electromagnetic Linear Motor

  • Fukada, Shigeo;Nishimura, Kentaro
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.49-53
    • /
    • 2007
  • In this study, we investigated experimentally the potential of a planer positioning mechanism with three degrees of freedom using a flexure guide and an electromagnetic linear motor. The goal was to produce a multi-axis positioning system with nanometric resolution over a 1-mm stroke. An $X-Y-\theta$ stage was designed based on previous results from a single-axis prototype and was constructed with a flexure guide mechanism and voice coil motor type linear actuators. We examined the necessity of a driving method and control system to ensure high resolution for multi-axis positioning. Experiments were conducted to evaluate the performance, and the results confirmed the mechanism's potential; fine point-to-point (PTP) positioning was achieved over a 1-mm stroke, with a resolution of 2 nm for translation in X-Y and 0.01 asec for yaw in $\theta$.

High Resolution Linear Graphs : Graphical Aids for Designing Off-Line Process Control)

  • Lee, Sang-Heon
    • 한국국방경영분석학회지
    • /
    • 제27권1호
    • /
    • pp.73-88
    • /
    • 2001
  • Designing high quality products and processes at a low cost is central technological and economic challenge to the engineer. The combination of engineering concepts and statistical implementations offered by Taguchi\`s off-line design technique has proven t be invaluable. By examining some deficiencies in designs from the Taguchi\`s highly fractional, orthogonal main effect plan based on orthogonal arrays, alternative method is proposed. The maximum resolution or the minimum aberration criterion is commonly used for selecting 2$^{n-m}$ fractional designs. We present new high resolution (low aberration) linear graphs to simplify the complexity of selecting designs with desirable statistical properties. The new linear graphs approach shows a substantial improvement over Taguchi\`s linear graphs and other related graphical methods for planning experiment. The new set of linear graphs will allow the experimenter to maintain the simple approach suggested by Taguchi while obtaining the best statistical properties of the resulting design such as minimum aberration as a by-product without dependency on complicated computational algorithm or additional statistical training.g.

  • PDF

A Study on 3D Road Extraction From Three Linear Scanner

  • Yun, SHI;SHIBASAKI, Ryosuke
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.301-303
    • /
    • 2003
  • The extraction of 3D road network from high-resolution aerial images is still one of the current challenges in digital photogrammetry and computer vision. For many years, there are many researcher groups working for this task, but unt il now, there are no papers for doing this with TLS (Three linear scanner), which has been developed for the past several years, and has very high-resolution (about 3 cm in ground resolution). In this paper, we present a methodology of road extraction from high-resolution digital imagery taken over urban areas using this modern photogrammetry’s scanner (TLS). The key features of the approach are: (1) Because of high resolution of TLS image, our extraction method is especially designed for constructing 3D road map for next -generation digital navigation map; (2) for extracting road, we use the global context of the intensity variations associated with different features of road (i.e. zebra line and center line), prior to any local edge. So extraction can become comparatively easy, because we can use different special edge detector according different features. The results achieved with our approach show that it is possible and economic to extract 3D road data from Three Linear Scanner to construct next -generation digital navigation road map.

  • PDF

GENERATION OF FOREST FRACTION MAP WITH MODIS IMAGES USING ENDMEMBER EXTRACTED FROM HIGH RESOLUTION IMAGE

  • Kim, Tae-Geun;Lee, Kyu-Sung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.468-470
    • /
    • 2007
  • This paper is to present an approach for generating coarse resolution (MODIS data) fraction images of forested region in Korea peninsula using forest type area fraction derived from high resolution data (ASTER data) in regional forest area. A 15-m spatial resolution multi-spectral ASTER image was acquired under clear sky conditions on September 22, 2003 over the forested area near Seoul, Korea and was used to select each end-member that represent a pure reflectance of component of forest such as different forest, bare soil and water. The area fraction of selected each end-member and a 500-m spatial resolution MODIS reflectance product covering study area was applied to a linear mixture inversion model for calculating the fraction image of forest component across the South Korea. We found that the area fraction values of each end-member observed from high resolution image data could be used to separate forest cover in low resolution image data.

  • PDF

고분해능을 갖는 간섭계형 리니어 스케일 제작 및 성능 평가 (Implementation and performance estimation of interferometer-type linear scale with high-resolution)

  • 김수진;은재정;최평석;권오영
    • 융합신호처리학회논문지
    • /
    • 제2권3호
    • /
    • pp.86-92
    • /
    • 2001
  • 미소 단위로 이동하는 물체의 이동 거리를 측정하기 위한 정밀 측정기기, 반도체 제조 장치, 공작기계 등의 위치 제어는 매우 중요한 요건이며, 이러한 장치들의 이동거리 측정에 대한 정확도는 전체 시스템의 성능을 좌우하게 된다. 따라서 정밀기기에서 이동 거리를 고정밀도로 측정할 수 있는 센싱 디바이스가 요구되며, 여기에는 레이저 간섭계의 분해능에 준하는 분해능을 갖고, 경제성 및 디지털 인터페이스에 대한 장점을 갖는 광학식 엔코더가 사용될 수 있다. 본 논문에서는 이동 거리를 측정하기 위해 회절 원리를 기초로한 고분해능 및 디지털 인터페이스가 용이한 간섭계형 리니어 스케일을 실험적으로 구성하였다. 그리고 이 리니어 스케일에서 발생된 간섭 신호는 제작된 광 검출기와 신호처리 회로를 통해 디지털화하였다. 그 결과 실험적으로 구성된 간섭계형 리니어 스케일은 스케일의 이동에 대하여 어떠한 분주 회로도 추가하지 않고, 단지 쉬운 광학적 구성으로 0.5$\mu\textrm{m}$의 분해능을 얻었다.

  • PDF

Ultrahigh-Resolution Spectral Domain Optical Coherence Tomography Based on a Linear-Wavenumber Spectrometer

  • Lee, Sang-Won;Kang, Heesung;Park, Joo Hyun;Lee, Tae Geol;Lee, Eun Seong;Lee, Jae Yong
    • Journal of the Optical Society of Korea
    • /
    • 제19권1호
    • /
    • pp.55-62
    • /
    • 2015
  • In this study we demonstrate ultrahigh-resolution spectral domain optical coherence tomography (UHR SD-OCT) with a linear-wavenumber (k) spectrometer, to accelerate signal processing and to display two-dimensional (2-D) images in real time. First, we performed a numerical simulation to find the optimal parameters for the linear-k spectrometer to achieve ultrahigh axial resolution, such as the number of grooves in a grating, the material for a dispersive prism, and the rotational angle between the grating and the dispersive prism. We found that a grating with 1200 grooves and an F2 equilateral prism at a rotational angle of $26.07^{\circ}$, in combination with a lens of focal length 85.1 mm, are suitable for UHR SD-OCT with the imaging depth range (limited by spectrometer resolution) set at 2.0 mm. As guided by the simulation results, we constructed the linear-k spectrometer needed to implement a UHR SD-OCT. The actual imaging depth range was measured to be approximately 2.1 mm, and axial resolution of $3.8{\mu}m$ in air was achieved, corresponding to $2.8{\mu}m$ in tissue (n = 1.35). The sensitivity was -91 dB with -10 dB roll-off at 1.5 mm depth. We demonstrated a 128.2 fps acquisition rate for OCT images with 800 lines/frame, by taking advantage of NVIDIA's compute unified device architecture (CUDA) technology, which allowed for real-time signal processing compatible with the speed of the spectrometer's data acquisition.

단일이미지에서의 초해상도 영상 생성을 위한 패치 정보 기반의 선형 보간 연구 (Patch Information based Linear Interpolation for Generating Super-Resolution Images in a Single Image)

  • 한현호;이종용;정계동;이상훈
    • 한국융합학회논문지
    • /
    • 제9권6호
    • /
    • pp.45-52
    • /
    • 2018
  • 본 논문은 단일 이미지에서 초해상도 영상 생성을 위해 저해상도 이미지에서 생성한 패치정보를 기반으로 선형보간하는 방법을 제안하였다. 기존의 초해상도 생성 방법인 전역 공간의 회귀 모델을 사용하면 특정 영역에 대해 참조할 정보가 부족하여 일반적으로 품질이 떨어지는 결과가 나타난다. 이러한 결과를 보완하기 위해 제안하는 방법은 초해상도 이미지 생성 과정에서 영상을 패치 단위로 지역을 분할하여 의미있는 정보를 수집하고, 수집된 정보를 기반으로 초해상도 이미지 생성을 위해 확장시킨 이미지 매트릭스 영역의 구성정보를 분석하여 선형 보간 과정을 거치고 패치정보를 대응시켜 탐색한 최적의 패치 정보를 기준으로 선형 보간하는 방법을 제안하였다. 실험을 위해 원본 이미지를 복원된 영상과 PSNR, SSIM으로 비교 평가하였다.