• 제목/요약/키워드: linear pump

검색결과 179건 처리시간 0.023초

라만 후방향산란을 이용한 레이저 펄스 증폭 가시화 (Visualization of Laser Pulse Amplification by Raman Backscattering)

  • 이해준;김진철;김창범;김광훈;김종욱;석희용
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.73-76
    • /
    • 2002
  • A one-dimensional fluid model has been established for Raman amplification of a short laser pulse in a plasma by a counter-propagating pump. The laser pulse is amplified with a large gain and also may be compressed by nonlinear three-wave Interactions. The spatiotemporal evolutions of the seed and the pump pulses were visualized for linear and nonlinear regimes, and the transition from regular to chaotic behavior of subsidiary pulses was investigated with variation of pump intensity.

  • PDF

Development of the Dynamic Simulation Program of a Multi-Inverter Heat Pump under Frosting Conditions

  • Park Byung-Duck;Lee Joo-Dong;Chung Baik-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권3호
    • /
    • pp.113-122
    • /
    • 2004
  • In case of heat exchangers operating under frosting condition, the thermal resistance and the air-side pressure loss increase with a growth of frost layer. In this paper, a transient characteristic prediction model of the heat transfer for a multi-inverter heat pump with frosting on its surface was presented by taking into account the change of the fin efficiency due to the growth of the frost layer. This dynamic simulation program was developed for a basic air conditioning system composed of an evaporator, a condenser, a compressor, a linear electronic expansion valve, and a bypass circuit. The theoretical model was derived from measured heat transfer and mass transfer coefficients. We also considered that the heat transfer performance was only affected by the decrease of wind flow area. The calculated results were compared with the experimental results for frosting conditions.

소유역에서 홍수조절용 펌프 및 유수지 규모의 결정에 관한 연구 (A Study on Determination of Capacity for Pump and Detention Pond in Small Basins for Flood Control)

  • 안태진;박종윤;류희정;김중훈
    • 한국수자원학회논문집
    • /
    • 제36권3호
    • /
    • pp.385-398
    • /
    • 2003
  • 내배수시설계획시 최대저류비에 의한 유수지 규모의 결정 방법은 이전 연구자에 의하여 제시된 바 있다. 본 연구에서는 동두천시 11개 소규모 내배수시설을 선정하여 분석한 결과, 배수면적이 작고 펌프기능이 강화된 내배수 시설에서는 강우지속기간별 우수지의 저류비의 차이는 미미하므로 최대저류비에 의한 조정지 규모의 결정은 무리가 있음을 알 수 있었다. 또한 최대저류비에 의하여 결정된 조정지 용량을 펌프에 의하여 배제되는 시간은 펌프의 허용시동간격보다 짧은 경우도 있어 펌프의 빈번한 작동을 초래한다. 그러므로 조정지는 펌프의 빈번한 작동에 의한 펌프 고장의 가능성을 피할 수 있는 규모로 결정되어야 한다. 다양한 펌프용량을 적용하여 분석한 결과, 소유역에서도 조정지의 기능이 강화된 내수배제시설에서는 최대저류비를 기준으로 한 조정지 용량의 결정은 펌프운영 측면에서 타당함을 알 수 있었다. 따라서 본 연구에서는 소규모 배수구역에서 조정지용량의 결정시 펌프의 계획배수량과 유수지의 용량에 따른 펌프의 시동빈도를 반영하여 기존의 최대저류비에 의한 방법을 개선한 방안을 제시하였다. 또한 유수지 규모와 펌프용량의 관계를 간단한 선형계획모형으로 분석한 결과, 종래의 유수지 홍수추적에 의한 유수지 용량 결정은 도시지역의 내배수시설 계획에만 타당함을 알 수 있었다.

용융아연 이송용 선형 전자기 펌프의 특성에 관한 연구 (A Study on the Characteristics of the Liner Electromagnetic Pump for Transferring Molten Zinc)

  • 김성원;홍성옥;김창업;심동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.142-144
    • /
    • 1999
  • This work deals with an application of linear induction motor. In the process of making steel, the molten zinc is required to flow by electromagnetic force. For this purpose, the characteristics of a single sided linear induction motor are analyzed at various conditions.

  • PDF

수분(水分)첨가된 옥수수(Corn-Cob-Mix)의 펌프 운송(運送) 시(時)의 유체성질(流體性質) 구명(究明) (Flow Properties of Water Additive Corn-Cob-Mix for Handling by Pump)

  • 오인환
    • Journal of Biosystems Engineering
    • /
    • 제14권1호
    • /
    • pp.33-40
    • /
    • 1989
  • The flow properties of water added com-cob-mix(CCM) were studied in order to provide basic information for designing its pumping system. For the study, a model system similar to actual situation was constructed. From the experiment, it can be concluded that the flow properties of the water added CCM has close relationship with its moisture content as follows; 1. The pressure drop caused by friction was very low when the moisture content of water added CCM was more than 70%. However, when the moisture content of the material is about 60%, the pressure drop increases up to 10 kPa/m at low pumping speed, and 20 kPa/m at high pumping speed, respectively. 2. The water added CCM having about 65% moisture content showed pseudo-plastic flow characteristics. 3. As the moisture content of the material decreases, the shear stress increases more rapidly than the shear rate does. Finally, below approximately 60% moisture, the shear stress becomes a linear relationship with the shear rate. 4. It was possible to pump the material having the moisture content down to 58% through a pipe having 80 mm diameter by a pump operating at 234 rpm. However, by either increasing the diameter of the pipe or decreasing the pumping speed, it can be possible to pump the material having lower moisture content than 55%.

  • PDF

저공해 중소형 디젤차량 히트펌프 제어 (Control of Heat Pump for Low Emission Diesel Engine)

  • 박병덕;이원석;원종필;권순익
    • 한국산업융합학회 논문집
    • /
    • 제5권4호
    • /
    • pp.379-384
    • /
    • 2002
  • As automotive diesel engines adopt the direct injection method for a lower level of the exhaust emission and a higher fuel efficiency, the maximum temperature of engine coolant decreases. Consequently, the total available heat source from the engine coolant decreases over 35%. However, the heating source of air-conditioning system in automobiles depends on the hot engine coolant completely, so that it is nearly impossible to control air conditioning in heating season. Therefore, the present study has been carried out to develop the air conditioning system for the high efficient heat pump type using the HFC-134a. Especially, the air conditioning system of heating has been developed at a beginning stage, when it has low heat source from small and medium sized diesel recreation vehicles. To develop a control logic system for air conditioning system which is a heat pump type with a heat recovery exchanger, its cycle characteristics has been investigated according to the opening of LEV at a bench system.

  • PDF

한국형 완전이식 인공심장의 개발 (Development of a Korean Type Totally Implantable TAH)

  • 민병구;최원우;안재목;박성근;박찬영;장준근;김종원;김희찬;김원곤;노준량
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.199-202
    • /
    • 1996
  • Artificial hearts are intended for use in patients with severe forms of heart disease for which no surgical repair is possible. The moving-actuator pump was developed to decrease the overall volume size of the electromechanical total artificial heart (TAH) by eliminating the occupied space of the fixed-actuator in the conventional pusher-plate type pump. In our pump, the actuator moves back and forth for alternative ejections of left and right ventricles. The problem of fitting the TAH to atrial remnants and arterial vessels could also be improved by circular or penduluous mot ion of the actuator instead of linear mot ion of the pusher-plate in the conventional pumps. We have evaluated two types of moving- actuator pump; one is a rolling cylinder type, and the other a pendulum type pump. In the rolling cylinder pump, frictional energy loss exists between the pump housing's guide bars and the actuator's end caps, while the bottom rack under the cylindrical actuator increases the height of the pump, the pump is therefor not implantable inside the small chest of human-sized animals with a body weight of less than 70kg. The new human type pump has a penduluous mot ion actuator to correct the above problems while maintaining the advantage of the moving- actuator's small total volume. The totally implantable TAH is composed of a blood pump, a control system and pheriperal equipments. The blood pump, which is constructed by a moving actuator, a right and left blood sac, and four artificial valves, is implanted in the thoracic. In 1988, the first implantation of the rolling cylinder TAH was performed into a female calf weighing 100kg, and the cal f recovered to the degree of voluntary standing and eat ing and survived to 100 hrs. We then survived two female sheep weighing about 63kg with the new human type TAH for three days.

  • PDF

시일 동특성에 미치는 원심응력의 영향에 관한 연구 (The Effects of Centrifugal Stress on Seal Dynamics)

  • 양보석
    • Tribology and Lubricants
    • /
    • 제5권1호
    • /
    • pp.64-68
    • /
    • 1989
  • The dynamic characteristics of the annular pressure seal employed in pump have been theoretically deduced with consideration of the effects of elastic deformation due to the centrifugal stress. The deformation of the shaft is governed by the linear theory of elasticity. The results derived herein considering the elastic deformation are compared with the previously published author's results in the stiffness and damping coefficients.

지하수 관개 시비의 지하수 내 질산성질소 저감 효과 평가 (Evaluation of the Effect of Pump and Fertilize on Nitrate Reduction in Groundwater)

  • 염여훈;김영;김문수;박선화;한경진
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제29권1호
    • /
    • pp.18-27
    • /
    • 2024
  • In this study, the pump and fertilize (PAF) was applied to reduce nitrogen infiltration into groundwater at three corn cultivation sites over a three-year period, and its effectiveness was evaluated. PAF involves pumping nitrate-contaminated groundwater and using it for irrigation, thereby replacing the need for chemical fertilizers. This method not only substitutes chemical fertilization, but also reduces nitrogen infiltration into groundwater through root zone consumption. To confirm PAF's effectiveness, an equal amount of nitrogen was applied in each cultivation plot, either through chemical fertilizer or irrigation with nitrate-contaminated groundwater. Regular monitoring of infiltrating pore water and groundwater was conducted in each cultivation plot. The linear regression slope for nitrate concentration in the pore water after repeated application of PAF ranged from -3.527 to -8.3485 mg-N/L/yr, confirming that PAF can reduce nitrate concentration in the pore water. With an increasing proportion of PAF, the infiltrating nitrate mass in pore water was reduced by 42% compared to plots fertilized with chemical fertilizer. Additionally, the linear regression slope of nitrate concentration in groundwater was calculated as -2.2999 and -9.2456 mg-N/L/yr. Therefore, continuous application of PAF in rural areas is expected to significantly contribute to reducing nitrate concentration in groundwater.

제어관점에서의 부하감지형 유압시스템의 특성 (Properties of the Load-Sensing Hydraulic System from a Viewpoint of Control)

  • 김성동
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.738-750
    • /
    • 1994
  • The load-sensing hydraulic system which was developed to improve energy efficiency of conventional hydraulic systems has its own properties. The instability of system responses, linearity of a servo valve, robustness for variation of external load, and dynamic interference between hydraulic motors are such properties which have much to do with control properties of the system. The load-sensing hydraulic system has instability tendancy because the load-sensing mechanism makes a positive feedback loop between the motor part and the pump part. A flow property of the servo valve can be said to be linear because the flow through the valve has nothing to do with a load pressure and the flow is strictly proportional to a valve opening which is adjusted by a valve command signal. The resultant control property can be said to be robust because the steady-state control performance is independent to the load actuated on the motor shaft. In the case when one pump simultaneously drives more than two hydraulic motors, the pump outlet pressure is determined by a hydraulic motor of the largest load pressure among all of the hydraulic motors, and, thus, the other motors are dominated by the largest load pressure. That is, the other motors can be said to be interfered by the motor of the largest load pressure.