• Title/Summary/Keyword: line-width

Search Result 1,550, Processing Time 0.033 seconds

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

Dose distribution at junctional area for head and neck radiotherapy (두경부 방사선치료시 접합 조사면의 선량분포)

  • 김정기;김기환;오영기;김진기;정동혁;신교철;양광모;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.161-169
    • /
    • 2001
  • For the head and neck radiotherapy, the technique of half beam using independent collimator is very useful to avoid overlapping of fields particularly when the lateral neck fields are placed adjacent to anterior supraclavicular field. Also abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom and the dose distribution at beam center of 2 half beams further examined according to depths(0 cm, 1.5 cm, 3 cm, 5 cm) for single anterior half beam and anterior/posterior half beam. The dose distribution to the junction line between photon and electron fields was also measured. For the single anterior half beam, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 88%, 93% and 95% of open beam, respectively. In the anterior/posterior half beams, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 92%, 93% and 95% of open beam, respectively At the junction line between photon and electron fields, hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to 6% of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was 4.5-30% of reference dose in the electron field. With above results, we concluded that when using electron beam or independent jaw for head and neck radiotherapy, the hot and cold dose area should be considered as critical point.

  • PDF

Dose distribution at junctional area abutting X-ray and electron fields (X-선과 전자선의 인접조사에서 접합 조사면에서의 선량분포)

  • Yang, Kwang-Mo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.91-99
    • /
    • 2004
  • Purpose : For the head and neck radiotherapy, abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Materials and methods : Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom according to depths(0 cm, 1.5 cm, 3 cm, 5 cm). 6 MV X-ray and 9 MeV electron(1Gy) were exposes to 8cm depth and surface(SSD 100cm) of phantom. The dose distribution to the junction line between photon($10cm{\times}10cm$ field with block) and electron($15cm{\times}15cm$ field with block) fields was also measured according to depths(0 cm, 0.5 1.5 cm, 3 cm, 5 cm). Results : At the junction line between photon and electron fields, the hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to $6\%$ of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was $4.5-30\%$ of reference dose in the electron field. Conclusion : When we make use of abutting photon field with electron field for the treatment of head and neck cancer we should consider the hot and cold dose area in the junction of photon and electron field according to location of tumor.

  • PDF

Converting Lands that are damaged by Graveyards into Tree Burial Sites in order to Restore Green Areas (산지묘지의 훼손지 복원을 위한 수목장지로의 전환)

  • Woo, Jae-Wook;Byun, Woo-Hyuk;Kim, Hak-Beom;Park, Won-Kyoung;Kim, Min-Su;Norsyuhada, Norsyuhada
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.3
    • /
    • pp.69-80
    • /
    • 2012
  • The purpose of this paper was to study the issues related to converting the graveyards within forests into spaces intended for tree burials by means of planting, given the situation that the graveyards have encroached on land and damaged the environment. For the reason, a field survey was performed to determine the width, length, and distance to the nearest tree of 205 graveyards in the capital area. Through this, it was determined that the domestic lands damaged by graveyards amounted to $862km^2$, including the areas that were deforested to manage the graves. This only confirms that land encroachment by graveyards is a serious issue. The methods for making tree burial sites were examined from the perspective of how to meet public demands given the graveyard's spatial distinctiveness. As a result, this study suggested different methods to establish tree burial sites according to the degree of transformation and the term of its formation. This study also classified the graveyards into three types, and identified the planting methods that harmonized the safe growth of trees and the scenic beauty of memorial places based on the standard. This is in order to plant trees that are shade-tolerant and suitable to the forest line, along with which other tree line was and also, to plant aesthetic trees around the empty space. Through applying the developed methods, this study established and monitored two exemplary sites in Yongin and Boryeng. Aesthetic trees were planted in Yongin site which was located in an open area, aod the shade-tolerant trees were planted in Boryeong, which was located in a forest area. As a result, the image of a garden appeared at Yongin site and the image of a tree colony harmonized with the near forest emerged at Boryeong site. Therefore, it is confirmed that the method of planting according to the distribution status of neighboring trees was effective. As a result of monitoring, mulching wood chips were suitable for sites that were small or easy to approach. This is because the weeds were controlled in Yongin site by mulching. Furthermore, by monitoring the growth of 11 species of vegetation, this study confirmed that low and cover-type vegetations were suitable for tree burial sites. In Boryeong site, the wild cherry trees, which were planted as adult trees, all died, and the tilling of snake's beard, which were planted as cover vegetation, was slow. Therefore, this study found that seedlings were more suitable to plant in forest graveyards than adult trees, which were large and difficult to approach, and it was effective to use the remaining lawn and form a low vegetation after the crown of trees had expanded to such places.

Nanoscale Pattern Formation of Li2CO3 for Lithium-Ion Battery Anode Material by Pattern Transfer Printing (패턴전사 프린팅을 활용한 리튬이온 배터리 양극 기초소재 Li2CO3의 나노스케일 패턴화 방법)

  • Kang, Young Lim;Park, Tae Wan;Park, Eun-Soo;Lee, Junghoon;Wang, Jei-Pil;Park, Woon Ik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.83-89
    • /
    • 2020
  • For the past few decades, as part of efforts to protect the environment where fossil fuels, which have been a key energy resource for mankind, are becoming increasingly depleted and pollution due to industrial development, ecofriendly secondary batteries, hydrogen generating energy devices, energy storage systems, and many other new energy technologies are being developed. Among them, the lithium-ion battery (LIB) is considered to be a next-generation energy device suitable for application as a large-capacity battery and capable of industrial application due to its high energy density and long lifespan. However, considering the growing battery market such as eco-friendly electric vehicles and drones, it is expected that a large amount of battery waste will spill out from some point due to the end of life. In order to prepare for this situation, development of a process for recovering lithium and various valuable metals from waste batteries is required, and at the same time, a plan to recycle them is socially required. In this study, we introduce a nanoscale pattern transfer printing (NTP) process of Li2CO3, a representative anode material for lithium ion batteries, one of the strategic materials for recycling waste batteries. First, Li2CO3 powder was formed by pressing in a vacuum, and a 3-inch sputter target for very pure Li2CO3 thin film deposition was successfully produced through high-temperature sintering. The target was mounted on a sputtering device, and a well-ordered Li2CO3 line pattern with a width of 250 nm was successfully obtained on the Si substrate using the NTP process. In addition, based on the nTP method, the periodic Li2CO3 line patterns were formed on the surfaces of metal, glass, flexible polymer substrates, and even curved goggles. These results are expected to be applied to the thin films of various functional materials used in battery devices in the future, and is also expected to be particularly helpful in improving the performance of lithium-ion battery devices on various substrates.

A STUDY ON THE MANDIBULAR MOVEMENT CHANGES AFTER ORTHOGNATHIC SURGERY IN SKELETAL CLASS III PATIENTS (악교정 수술 후 골격성 III급 부정교합 환자의 하악운동 변화에 관한 연구)

  • Nahm, Dong-Seok;Suhr, Cheong-Hoon;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.273-282
    • /
    • 1997
  • The purpose of this study was to evaluate changes in mandibular movement patterns after orthognathic surgery in skeletal Class III patients. The sample consisted of 20 Class III malocclusion patients(9 males, 11 females). Just before and after(2-7months) surgery, maximum opening & closing movement, mandibular border movement on sagittal, frontal and horizontal planes were recorded using Sirognathograph & BioPak EGN. On each record, 21 items were measured and statistically analyzed. The results were as follows 1. Angle of protrusive movement on sagittal plane showed greatest change after surgery. Also, as the incisal guidance was established by surgery, straight path of protrusive movement became curved line. 2. Maximum opening distance and maximum antero-posterior distance on maximum opening & closing movement, maximum opening distance on sagittal plane, angle of left lateral excursion on frontal plane were statistically significant after snrgery(p<0.01). 3. Maximum width of lateral excursion on frontal plane, distane of right lateral excursion and angle of maximum left lateral excursion on horizontal plane were statistiraily significant after surgery(p<0.05). 4. Maximum opening distance and maximum antero-posterior distance on maximum opening & closing movement showed significant differences according to post-surgical time(p<0.05). More recovery of range of movement occured in 5-7month group than in 2-3month group. 5. As the occlusal interferences were removed by orthognathic surgery, irregular opening & closing path became smooth curve.

  • PDF

Characteristic Study of Small-sized and Planer Resonator for Mobile Device in Magnetic Wireless Power Transfer (소형 모바일 기기용 공진형 무선전력전송 시스템의 공진기 평면화 및 소형화에 따른 특성 연구)

  • Lee, Hoon-Hee;Jung, Chang-Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.16-21
    • /
    • 2017
  • In this paper, a Small-sized and planer resonator design of Magnetic Resonance - Wireless Power Transfer(MR-WPT) were proposed for practical applications of mobile devices, such as a laptop, a smart-phone and a tablet pc. The proposed MR-WPT system were based on four coil MR-WPT and designed as a transmitter part (Tx) and a receiver part (Rx) both are the same shape with the same loop and resonator. There are four different spiral coil type of resonators with variable of line length, width, gap and turns in $50mm{\times}50mm$ size. The both of top and bottom side of substrate(acrylic; ${\varepsilon}_r=2.56$, tan ${\delta}=0.008$) ere used to generate high inductance and capacitance in limited small volume. Loops were designed on the same plane of resonator to reduce their volume, and there are three different size. The proposed MR-WPT system were fabricated with two acrylic substrate plane of Tx and Rx each, the Rx and Tx loops and resonators were fabricated of copper sheets. There are 12 combinations of 3 loops and 4 resonators, each combination were measured to calculate transfer efficiency and resonance frequency in transfer distance from 1cm to 5cm. The measured results, the highest transfer efficiency was about 70%, and average transfer efficiency was 40%, on the resonance frequency was about 6.78 MHz, which is standard band by A4WP. We proposed small-sized and planer resonator of MR-WPT and showed possibility of mobile applications for small devices.

A Study on the Women's Bodysuit Sleeve Block Construction Using Stretch fabrics (Stretch 소재를 사용한 여성용 Bodysuit Sleeve 원형 설계에 관한 연구)

  • Park Gin-Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1535-1545
    • /
    • 2005
  • The study aimed firstly, to develop the women's bodysuit sleeve block construction method adopting the appropriate pattern reduction rates according to the fabric stretch property. Secondly, the details applied to the bodysuit sleeve block drafting (Dr the educational and industrial usage were proposed. For these, several distinguishing bodysuit sleeve pattern making methods(i.e. Joseph-Armstrong: T1, Shoben & Ward: T2, Esmod: T3 and Mixed Joseph-Armstrong: T4) were analyzed and divided into two categories that adopt 1) the equally (i.e., T1) and 2) the differently(i.e., T2, T3 & T4) distributed front and back armhole length measurements. Women's sleeve samples were made for the research using the same stretch fabric($50\%\;and\; 70\%$ in wale and course each) to the previous research. A group comprising 5 relevant experts evaluated the fit and comfort features of the samples. Experiments analyzed the appearance of sleeve samples focused on total 13 evaluation parts(including the front/side/back fit tolerance, sleeve centre line, sleeve length, appropriateness of the sleeve appearance balanced with the bodysuit and etc.): and performed the comfort test evaluating three kinds(vertical-front/vertical-side/ horizontal) of arm movements. The most appropriate bodysuit sleeve to fulfil the original aims of the study was suggested. The findings and suggestions throughout the study were: 1) the measurements and required reduction rates for the bodysuit sleeve block developed: outer sleeve length (with 1.0 RR), crown height(with 0.7 RR), front and back armhole lengths measured on the bodysuit blocks ($0\%$ ease amount), elbow width(0.9/0.95 RR), wrist girth measurements(from $12\%\;to\;18\%$ tolerances can be given to): and 2) the differently distributed front and back armhole length measurements resulted in the better fit and comfort through the research.

SSR Marker Related to Major Characteristics Affected Kernel Quality in Waxy Corn Inbred Lines (찰옥수수 자식계통의 주요 품질특성과 관련된 SSR마커)

  • Jung, Tae-Wook;Moon, Hyeon-Gui;Son, Beom-Young;Kim, Sun-Lim;Kim, Soon-Kwon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.spc1
    • /
    • pp.185-192
    • /
    • 2006
  • This experiment was conducted to assess genetic diversity of waxy corn inbred lines and to identify SSR markers related to major characteristics affected kernel quality for improving waxy corn $F_1$ hybrid with good quality. Diversity of 64 waxy com inbred lines was evaluated using 30 microsatellite markers. The 30 microsatellite markers representing 30 loci in the maize genome detected polymorphisms among the 64 inbred lines and revealed 225 alleles with a mean of 7.5 alleles per primer. The polymorphism Information content (PIC) value ranged from 0.14 to 0.87, with an average of 0.69. Based on Nei's genetic distances, the 64 inbred lines were classified into 9 groups by the cluster analysis. The group I included 26 inbred lines (41%), other groups included 3 to 9 inbred lines. One-way analysis of variance was conducted to identify significant relationship between individual markers and major characteristics that affect kernel quality. The analysis showed that umc1019 was related to amylopectin and crude protein content, me 1020 to amylopectin content and peak viscosity, and bnlg1537 to 100-kernel weight, kernel length, and kernel width.