• Title/Summary/Keyword: line voltage difference

Search Result 102, Processing Time 0.026 seconds

Sensorless Drive of the BLDC Motor using a Line Voltage Difference (선간 전압을 이용한 BLDC 모터의 센서리스 구동)

  • Kim, Tae-Yeon;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.6
    • /
    • pp.508-512
    • /
    • 2013
  • In recent years, sensorless drive schemes have been proposed widely and most of them are based on the ZCP (Zero Crossing Point) detection of the BEMF (Back Electro-Motive Force). These schemes have two main problems. One is that ZCP may not be detected at low speed and thus a forced drive is required. The other problem is that there is $30^{\circ}$ phase difference between ZCP and the motor commutation instant and to ensure proper operation, this gap should be accounted for. To solve these problems a circuit is devised for detecting ZCP of the BEMF difference through the line voltage difference. Experimental results show that the output of this circuit is identical to that of the Hall sensor signal, and velocity control of a BLDC motor is possible without the sensor.

Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line (22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

Transmission Line Based Plucked String Model (전송선로 기반 탄현 모델)

  • Lee, Jingeol;French, Mark
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.361-368
    • /
    • 2013
  • As one way to describe the behavior of a vibrating string, analogies to a transmission line have been made based on the fact that they have oppositely travelling waves on each of them. In such analogies, a rigid end to the string has been represented as an open circuit, and the displacement of the string as the current on the transmission line. However it turns out that the rigid end corresponds to a short circuit, the displacement to the voltage by the theory of the transmission line, and it is confirmed by experiments with circuit simulations. Based on these discoveries, a transmission line based plucked string model comprising a transmission line, two piecewise linear current sources, and switches is proposed. The proposed model is validated by showing that the voltage at the arbitrarily chosen location, and the voltage calculated over an infinitesimal portion at the end of the transmission line are consistent with the displacement at the corresponding location and the force on the rigid end of the string from the well known difference form of a wave equation governing the behavior of the string with its fundamental frequency tuned to that for the proposed model, respectively. Moreover, the applicability of the proposed model to modeling string and wind instruments is presented.

The Inductive Interference of Communication Line Near by Transmission Line (송전선로 주변 통신선의 유도장해 원인 분석)

  • Kang, Y.W.;Kwak, J.S.;Kweon, D.J.;Shim, E.B.;Bae, J.H.;Kim, J.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.400-402
    • /
    • 2003
  • The inductive interference can be happened on some of the communication line that is located near by paralleled transmission line. The causes of inductive interference are magnetic coupling, capacitive coupling and residual voltage at neutral point of transmission line. In this paper, after grounding the one side of communication line, we have measured the voltage to ground at the other side of it. And we also have measured the voltage to ground at the end of it without grounding. As a result, we proved that the cause of inductive interference is the difference of ground voltages.

  • PDF

Fault Phase Selection Algorithm using Unit Vector of Sequence Voltages for Transmission Line Protection (대칭분 전압 단위 벡터를 이용한 송전선로 보호용 고장상 선택 알고리즘)

  • Lee, Myeong-Su;Lee, Jae-Gyu;Kim, Su-Nam;Yu, Seok-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.9
    • /
    • pp.460-466
    • /
    • 2002
  • A reliable fault phase selection algorithm plays a very important role in transmission line protection, Particularly in Extra High Voltage (EHV) networks. The conventional fault phase selection algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and select the fault phase in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can select the accurately fault phase using the sum of unit vectors which are calculated by positive-sequence voltage and negative-sequence voltage.

Design of off-line UPS with AVR (AVR 기능 부가 off-line UPS 설계)

  • Lee, Seung-Hee;Park, Tae-Jun;Lee, Jin-Hee;Lee, Wang-Ha;Lee, Chi-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.605-607
    • /
    • 2001
  • In this paper, an off-tine UPS with CVT(constant voltage transformer) is designed and the experimental result and problems of the designed UPS is given and discussed. This off-line UPS consists of triple-port CVT and PWM inverter which acts as charger and inverter. It can be evaluated in low price because haying simple structure. It offers high performance because CVT restricts the short current automatically about two or three times of rated current, has nearly unit power factor and constant output voltage to varying input voltage. The weak points of this UPS are that the output voltage waveform is not perfect sinusoidal and has phase difference to input voltage. The experimental result and problems of the designed UPS is given.

  • PDF

Comparative Analysis of Voltage Unbalance Factor on the use of Linear and Non-linear loads in Three-phase Four-wire Low Voltage Distribution Line (3상 4선식 저압 배전선로에서 선형 및 비선형 부하의 사용시 전압 불평형률 비교 분석)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.587-592
    • /
    • 2017
  • In the three-phase four-wire low-voltage power distribution equipment, single-phase and three-phase load have been used mainly mixed. Also linear and nonlinear loads have been used together in the same conditions. In a three-phase four-wire distribution line, the current distribution of three-phase linear load is almost constant in each phase during driving or stopping, but the single-phase load is different from each other for each phase in accordance with the operation and stop. So that the voltage unbalance is caused by the current difference of each phase. In the three-phase four-wire distribution system, non-linear load is used with linear load. The presence of single-phase nonlinear loads can produce an increase in harmonic currents in three-phase and neutral line. It can also cause voltage unbalance. In the present study, we analyzed for the voltage unbalance fluctuations by the operation pattern of the single and three-phase linear and non-linear load in three-phase four-wire low voltage distribution system.

Substation Bus Voltage Angle Calculation Method Using Voltage Angle Difference Measured at the Tie Switch in the Distribution Line (배전선로 상시연계점 측정 전압 위상차를 이용한 변전소 모선 위상각 추정 방법)

  • Son, Ju-Hwan;Lim, Seong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • Distribution networks are operated in radial fashion during the normal state. Loop configuration is also required temporally in case of live load transfer among the adjacent feeders. Voltage angles of each substation buses are very important data in order to calculate power flow of the loop structured distribution feeders. This paper proposes substation bus voltage angle calculation method using voltage angle difference measured at the normally open tie switches. Simulation case studies using Matlab simulink have been performed to establish feasibility of proposed method.

The Basic Insulation Design of 60 kV Bushing for Netural Line of 154 kV Class HTS Transformer (154 kV급 고온초전도 변압기의 중성선용 60 kV 부싱의 기초 절연설계)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.3
    • /
    • pp.32-35
    • /
    • 2008
  • A common problem in many fields of cryogenic power engineering is applying high voltage to cold parts of superconducting apparatus. In many cases, a bushing provides electrical insulation for the conductor which makes the transition from ambient temperature to the cold environment. The 60 kV class cryogenic high voltage bushing for neutral line of the 154 kV / 100MVA high temperature superconducting (HTS) transformer was described. The bushing is energized with the line-to-ground voltage between the coaxial center and outer surrounding conductors; in the axial direction, there was a temperature difference from ambient to about 77 K. For the insulation design of cryogenic bushing, electrical insulation characteristics of the GFRP were discussed in this paper.

Study on the High Voltage Pulse Profile Characteristics of a Turbulently Heated Theta Pinch (난류가열 쎄타핀치의 고전압 펄스 발생에 관한 연구)

  • 강형보;정운관;육종철
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.11
    • /
    • pp.456-463
    • /
    • 1984
  • The fast-rising high-voltage pulse generation circuit system of a theta pinch is both theoretically and experimentally investigated. The idealized model of this circuit system is a hybrid circuit system composed of three parts: a lumped circuit part being consisted of a capacitor bank and a spark switch connected in series, another lumped circuit part being consisted of the Blumlein transmission line, whose end load is the pinch coil. the voltage difference between two ends of the pinch coil is formulated by analyzing this hybrid circuit system by means of the law of the signal propagation in the transmission line and Kirchhoff's laws. The expedient numerical method for computer calculation is developed to generate the pulse profile of the voltage difference across the pinch coil. The period of the experimentally measured main pulse is a fourth of the theoretical one neglecting the resistance of the pinch coil. We attribute this discrepancy to the modelling in the theoretical calculation that hte resistance and inductance of the spark switch and capacitor bank are assumed to be constant through discharge. Therefore, we can see that the rise time of the imploding magnetic-field pulse is mainly dependent on the spark switch and capacitor bank.

  • PDF