• Title/Summary/Keyword: line test

Search Result 4,453, Processing Time 0.036 seconds

Test Method of Communication Reliability based on HPGP between PEV and EVSE (전기차와 충전기 간 HPGP 기반 통신 신뢰성 테스트 방안)

  • Choi, Byeong-Gon;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • Smart Grid is a next-generation intelligent grid to optimize energy efficiency by integrating information and communication technologies to the existing power grid as a two-way exchange of information. HPGP communication standard for smart grid implementation has been developed for the emerging smart energy, home automation, electric vehicle communications applications. HPGP communication standard has the advantage of reducing cost and power consumption. Also, it can be interoperated with the previous HPAV communication standard. For the introduction of a new communication standard, the analysis of the reliability and interoperability verification is required. In this paper, we present sniffer test method as reliability test method about power line communication between PEV(Plug-in Electric Vehicle) and EVSE(Electric Vehicle Supply Equipment). Power line communication between PEV and EVSE is one of the most important Smart Gird applications. Also, we analyzed sniffer test results about power line communication based on HPGP between PEV and EVSE by using QCA7000 device, AVitar and Tool kit.

A Study of Generator Excitation System for first Power Supply to gird line (가스터빈 시송전 발전기 여자시스템에 관한 연구)

  • Ryu, Ho-Seon;Lim, Ick-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1193-1194
    • /
    • 2011
  • We performed commissioning of redundant digital excitation system for gas turbine generator. One of its issues is first power supply test to gird line when it was compared with the other commissioning. If blackout will be happened, a few of start power plants must supply power to grid line. And then generator must increase voltage and real power slowly for line charge. The trial product was installed and successfully operated at a 100MW power plant after commissioning.

  • PDF

Inhibitory Effect of Artemisia princeps Pampan.. Extract on Growth of Cancer Cell Lines (쑥(Artemisia princeps Pampan) 추출 성분의 암세포증식 억제효과)

  • 황윤경
    • Journal of Nutrition and Health
    • /
    • v.31 no.4
    • /
    • pp.799-808
    • /
    • 1998
  • To investigate the antitumor activity of mugwort (Artemisia princeps Pampan), petroleum ether extract of mugwork was partially purified by a silica gel chromatography. Among several fractions, the fraction which was obtained under the elution with acetone, showed potent cytotoxicity against mouse leukemia cell line(Ll210), human colon cancer cell line (HCT-48) and human hepatoma cell line (Hep G2) , but was less effective with normal cell line(mouse embryo cell). Acetone fraction appeared to be glycolipid by Benedict test and the major fatty acids of the lipid were C16 ; 0 , C 18: 3by GC/MS analysis.

  • PDF

On-Line Insulation Diagnosis Techniques for Stator Winding of Rotating Machines (회전기 고정자 권선에서의 운전 중 절연열화 진단기법)

  • 윤대희;황돈하;신병철;김용주;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.89-93
    • /
    • 2000
  • Recently many research activities on the diagnosis of stator winding insulation of large rotating machines have been reported. Capacitive couplers are widely used as sensors for on-line partial discharge (PD) measurement of high voltage rotating machines. This paper presents laboratory test to compare Stator Slot Coupler (SSC), Resistance Temperature Detector (RTD), 80 [pF] coupler and 500 [pF] coupler for on-line PD measurement of rotating machines. And a novel on-line monitoring system for an insulation diagnosis is proposed.

  • PDF

Predicting formula development of audible noise on a 765kV AC transmission line(I) (765kV 교류 송전선로의 가청소음계산 예측식개발(I))

  • 이동일;구자윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.612-615
    • /
    • 1996
  • Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500kV and above. Therefore this paper describes audible noise characteristics of 6 X 480mm conductor bundle in KEPRI 765kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765kV transmission Line was developed using this results.

  • PDF

Vibration Test Result and Consideration for AUTS(Advanced Urban Transit System (차세대전동차 진동시험 결과 및 고찰)

  • Hong, Jai-Sung;Kim, Gil-Dong;Lee, Chang-Mu;Won, Jong-Un;Lee, An-Ho;Sung, Chang-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2276-2279
    • /
    • 2011
  • The AUTS(Advanced Urban Transit System) are developed by government R&D business. This units are under main line performance test in Daebul test line. Both AC and DC could apply to the AUTS for pantagraph voltage. So main transformer and some high voltage filters are added to the under-frame. As a result the total weight of each car(Mc1-Tp1-M-T-Tp2-Mc2) is different. And axle load is different each other. The main characteristics of AUTS(Advanced Urban Transit System) are as follows. One inverter control one motor, DDM(Dircet Drive Motor), no driving gear, plug no end door, self-steering bogie etc. These matters could be appeared to strange vibration. So vibration test is important. The vibration test performed to Mc1 and Tp1. The results were checked to the up-down direction and left-right direction for acceleration.

  • PDF

Analysis and Test of CBTC Wireless Communication System in KyungSan test Line (II) (경산시험선 CBTC 시스템용 무선통신시스템 시험(2))

  • Ryu, Sang-Hwan;Cho, Bong-Kwan;Lee, An-Ho;Hwang, Hyeon-Chyeol;Yang, Doh-Chul
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2735-2744
    • /
    • 2011
  • Korean-Automated Guideway Transit (K-AGT) was successfully developed through Light Rail System Development Project. Since then, the domestic development rate of on-board signalling system of light rail has been improved up to 90% by Practical Utilization Project of Light Rail. After utilization project, furthermore, POSCO ICT has developed the wayside signalling system of CBTC, including wireless communication equipment. KRRI carried out the performance test of the wireless communication, interfacing and using the other CBTC equipments of KyungSan Test Line so as to see whether it conforms IEEE 802.11x, international communication standard in view of operational concept of CBTC. In this paper, we presents analysis results of roaming test while train runs.

  • PDF

A Study on the Structural Strength of the Rolling Stock Seat Frame (철도차량 시트프레임의 강도 평가 연구)

  • 구정서;조현직
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.130-138
    • /
    • 2004
  • In this paper, the structural strength of a rolling stock seat were numerically evaluated under several design load conditions based on the UIC requirements. The rot]ins stock seat was designed for the high speed train of a Chinese conventional line. To maximize its weight reduction and structural strength, an aluminium alloy, ALDC8-T5, was applied to the base frame, side frames and armrests. The designed seat frame satisfied the strength requirements on inertia loads and fatigue test conditions. However, it couldn't satisfy the requirements on the static test conditions of UIC 566 OR. Therefore, some design modifications were suggested and numerically evaluated whether the static test requirements could be satisfied or not.

Analysis of Insulation Characteristics for Stator Winding after Insulation Reinforcement (수력발전기 고정자권선의 절연보강 후 절연특성 분석)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Choi, Hyung-Cheol;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.71-73
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish Painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

A Study On Full Load Test of IGBT Type Propulsion System for Electric Railway in SMG 6 Line (전동차용 IGBT형 추진제어장치의 6호선 본선 만차 시험에 관한 연구)

  • 박건태;정만규;고영철;방이석;서광덕
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.666-673
    • /
    • 2000
  • This paper describes the full load test results of IGBT VVVF inverter for the railway propulsion system. The 1,650kVA IGBT VVVF inverter has been developed. Therefore, the field test is performed in SMG 6 Line to confirm its the reliability and performance. The train consists of 4M4T(4 Motor car 4 Trailer Car) and the electrical equipment for field test are as follows VVVF inverter 4 sets, 16 traction motors and 2 SIVs. The propulsion system is composed with IC4M(1-Controller 4-Motors). The results of propulsion system which have the excellent acceleration/deceleration and the jerk characteristics as well as starting ability on slope are taken through the field test.

  • PDF