• Title/Summary/Keyword: line source

Search Result 1,654, Processing Time 0.026 seconds

Automatic Generation of the Control Line Using Polygon based Vertex Search for Field-based Morphing (다각형 기반 정점 탐색에 의한 필드 기반 모핑의 제어선 자동 생성)

  • 이형진;김형민;곽노윤
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.05a
    • /
    • pp.377-384
    • /
    • 2004
  • The field based morphing requires the user to set most of the control lines manually which requires much time and skill to get satisfactory results. This thesis proposes a method to acquire semi-automation of image morphing through first acquiring shape information from the source image and the target image, then after the user manually designates the least amount of a pair of feature points, these are used as standards for polygon based vertex search to set the appropriate control line to the source mage and target image, and then using the ratio of control line lengths and space. Using the proposed method, the user can reduce the time setting the control line and unskilled persons can get natural image morphing results while designating the least amount control line.

  • PDF

The Properties and Uniformity Change of Amorphous SiC:H Film Deposited using Remote PECVD System with Various Deposition Conditions (원거리 플라즈마 화학기상증착법을 사용하여 증착한 비정질 탄화규소 막의 증착조건에 따른 특성 및 증착 균일도 변화)

  • Cho, Sung-Hyuk;Choi, Yoo-Youl;Choi, Doo-Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.3
    • /
    • pp.262-267
    • /
    • 2010
  • a-SiC has been thought as an ideal candidate for conventional silicon at many applications. However, the uniformity problem of deposition has been a obstacle for conventional use of a-SiC:H films. a-SiC:H films were deposited on (100) silicon wafer by RPECVD system in various temperature. HMDS and $H_2$ gas were used as a precursor and a carrier gas, respectively. The flow rate of HMDS source and $C_2H_2$ dilution gas was fixed in order to study the carbon effect on the film stoichiometric and bonding properties. The plasma power varied from 200 to 400W. We used three types of source delivery line to control the uniformity and film properties of deposited film. We showed that the change of source delivery line has effect on the film uniformity of deposited film and this change of line did not affect on film properties. Also, the change of deposition conditions has effect on the film uniformity.

Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea (국내 지중열전도도 측정 방법의 한계 및 개선 방향)

  • Shim, Byoung Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF

A Study of Borehole Thermal Behavior with 1-Dimensional Model;Field Test Analysis included (1차원 모델에 의한 보어홀 열거동 해석 및 현지측정)

  • Kim, Dae-Ki;Woo, Joung-Son;Ro, Jeong-Geun;Lee, Se-Kyoun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.550-554
    • /
    • 2007
  • A one-dimensional heat transfer model coupled with parameter estimation is developed in this study to predict the effective thermal conductivities of soil formation and borehole resistances from in situ field test data. In this application a new method of using initial ignoring time(IIT) obtained from error estimation is tried and turned out to be successful in determining soil thermal conductivities. The validity of this model is accomplished through comparison of the predicted temperature profiles of the model with the data from laboratory scale experimental setting. Eleven test boreholes were constructed in Ochang, Chungcheong Buk Do, and thermal response test was carried out with each borehole. The results of the in situ tests were analyzed with our 1-D numerical model and compared with the results of line source method. The comparison shows that the thermal properties from line source method is a little lower (${\sim}95%$)than those from numerical method. The reason of such result seems to be the lower thermal conductivity of grout material, which is not counted in line source method.

  • PDF

A Comparative Study of Two Diagnostic Methods Based on the Switching Voltage Pattern for IGBT Open-Circuit Faults in Voltage-Source Inverters

  • Wang, Yuxi;Li, Zhan;Xu, Minghui;Ma, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1087-1096
    • /
    • 2016
  • This paper reports an investigation conducted on two diagnostic methods based on the switching voltage pattern of IGBT open-circuit faults in voltage-source inverters (VSIs). One method was based on the bridge arm pole voltage, and the other was based on bridge arm line voltage. With an additional simple circuit, these two diagnostic methods detected and effectively identified single and multiple open-circuit faults of inverter IGBTs. A comparison of the times for the diagnosis and anti-interference features between these two methods is presented. The diagnostic time of both methods was less than 280ns in the best case. The diagnostic time for the method based on the bridge arm pole voltage was less than that of the method based on the bridge arm line voltage and was 1/2 of the fundamental period in the worst case. An experimental study was carried out to show the effectiveness of and the differences between these two methods.

Source-Overlapped Gate Length Effects at Tunneling current of Tunnel Field-Effect Transistor (소스영역으로 오버랩된 게이트 길이 변화에 따른 터널 트랜지스터의 터널링 전류에 대한 연구)

  • Lee, Ju-Chan;Ahn, Tae-Jun;Sim, Un-Sung;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.611-613
    • /
    • 2016
  • The characteristics of tunnel field-effect transistor(TFET) structure with source-overlapped gate was investigated using a TCAD simulations. Tunneling is mostly divided into line-tunneling and point-tunneling, and line-tunneling is higher performance than point-tunneling in terms of subthreshold swing(SS) and on-current. In this paper, from the simulation results of source-overlapped gate length effects at silicon(Si), germanium(Ge), Si-Ge hetero TFET structure, the guideline of optimal structure with highest performance are proposed.

  • PDF

IGRINS NIR Spectroscopy of Diffuse Sources around MWC 1080

  • Kim, Il-Joong;Oh, Heeyoung;Jeong, Woong-Seob;Lee, Jae-Joon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.48.1-48.1
    • /
    • 2019
  • We found a diffuse Hα feature with a large size of ~2' around a Herbig star, MWC 1080. It shows a strong correlation with the elongated outflow cavity centered on the star. To investigate the diffuse Hα source and the molecular cavity in detail, we carried out the high-resolution NIR spectroscopy using IGRINS. We detected six hydrogen Brackett line series, seven H2 lines, and an [Fe II] forbidden line. With the obtained spatial, kinematic, and line ratio results, we discuss the characteristics of the central MWC 1080A, the NE outflow cavity, and the SE molecular cloud regions separately. Most of the bright Brγ sources around MWC 1080A were found to be reflection nebulae, but a point-like Brγ source close to another young star, MWC 1080E, was identified as a distinct source due to MWC 1080E itself. The narrow components of the H2 lines observed around MWC 1080A were found to trace PDRs located on the wall of the main outflow cavity. Based on the shock-excited H2 and [Fe II] lines detected just inside a bow-shock shape Hα feature, we suggest that it represents the actual shock at the head of the NE outflow from MWC 1080A. Also, we newly detected the shock-excited H2 and [Fe II] lines with highly blueshifted velocities in the SE molecular cloud region. They could be related to unrevealed outflows from other young stars existing around MWC 1080A.

  • PDF

A Study on DC Changing Algorithm of the Line-Interactive UPS with Dual Converter Structure (2중 컨버터 구조를 갖는 계통 연계형 UPS의 DC 충전 알고리듬에 관한 연구)

  • Lee, Woo-Cheol;Yoo, Dong-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.27-34
    • /
    • 2005
  • This paper presents a three phase Line-Interactive uninterruptible power supply(UPS) system with dual converter structure. The three phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator, which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low total harmonic distortion(THD). This paper presents in the series and parallel active compensator charging method depending on the amplitude of the source voltage. The conventional Line-Interactive UPS system is responsible for the DC charging and output voltage regulation at the same time, but UPS system with dual converter structure, a series active compensator can also charge the DC link. Therefore the charging algorithm using the series and parallel compensator needs to be researched. Therefore, by making the DC link voltage stable it can contribute the stability of series and parallel compensator. The simulation and experimental result are depicted in this paper to show the effect of the proposed algorithm.

Design of High-gain W-band MMIC Amplifier Using Source Feedback (소스 피드백을 이용한 고이득 W-band MMIC 증폭기설계)

  • Park, Sang-Min;Kim, Young-Min;Koh, Yu-Min;Seo, Kwang-Seok;Kwon, Young-Woo;Jeong, Jin-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.10
    • /
    • pp.74-79
    • /
    • 2010
  • In this paper, a high gain W-band amplifier is presented using 70 run mHEMT MMIC technology. The length of source feedback line of common-source FET is carefully determined to maximize the gain at a design frequency. Simulation shows that MAG can be increased by 0.8 dB by optimizing the length of this line. In addition, this feedback line changes the input impedance of the common-source FET in a way that the input match can be made easier. In this work, 4-stage amplifier is designed on CPW using the source feedback. The measurement shows the excellent gain performance higher than 22.0 dB across 70~103 GHz.

Voltage Control in a Novel Three-Phase Line Interactive UPS System with Parallel-Series Active Power Line Conditioning Capabilities using AC Line Reactor (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스뎀의 전압제어)

  • Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1072-1077
    • /
    • 2006
  • In this paper a novel 3-phase line interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) is proposed. And the strategy of voltage control in proposed UPS system is explained. The objective of voltage control in parallel(shunt) and series PWM VSC of proposed UPS system is to guarantee satisfactory characteristics in steady state and transient state.

  • PDF