• Title/Summary/Keyword: line position measurement

Search Result 182, Processing Time 0.028 seconds

In Vitro Assessment of MRI Safety at 1.5 T and 3.0 T for Bone-Anchored Hearing Aid Implant (Bone-Anchored Hearing Aid Implant에 대한 1.5 T와 3.0 T에서 MRI 안전성의 생체외 평가)

  • Yeon, Kyoo-Jin;Kim, Hyun-Soo;Lee, Seung-keun;Lee, Tae-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • The aim of this study was to evaluate Magnetic Resonance Imaging safety by measuring the translational attraction, torque and susceptibility artifact for Bone-Anchored Hearing Aid (BAHA) implant at 1.5 T and 3.0 T MRI by standard criteria. In vitro assessment tools were made of acrylic-resin by American Society for Testing and Materials (ASTM) F2052-06 and F2119-07 standard. Translational attraction of BAHA implant was measured by the maximum deflection angle at 96 cm position, where the magnetically induced deflection was the greatest. The torque was assessed by the qualitative criteria of evaluating the alignment and rotation pattern, when the BAHA implant was positioned on a line with $45^{\circ}$ intervals inside the circular container in the center of the bore. The susceptibility artifact images were obtained using the hanged test tool, which was filled with $CuSO_4$ solution. And then the artifact size was measured using Susceptibility A rtifact Measurement (SA M) software. In results, the translational attraction was 0 mm at both 1.5 T and 3.0 T and the torque was 0(no torque) at 1.5 T, and +1(mild torque) at 3.0 T. The size of susceptibility artifacts was between 13.20 mm and 38.91 mm. Therefore, The BAHA implant was safe for the patient in clinical MR environment.

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

STANDARDS FOR KOREAN ADULT FACIAL RELATIONSHIPS BY VARIOUS ROENTGENO - CEPHALOMETRIC ANALYSIS (두부(頭部)X선(線) 규격(規格) 측모사진계측(側貌寫眞計測)에 의한 한국인(韓國人) 성년남녀(成年男女)의 표준치(標準値)에 관(關)한 연구(硏究))

  • Lee, Chong Taik
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.459-474
    • /
    • 1988
  • A study was made of a method of rational assessment on the roentgeno-cephalogram in orthodontic practice. Fifty eight measurements were analyzed on the roentgeno-cephalograms of 50 male and 50 female Korean adults with the acceptable profile and the normal occlusion. The means and standard deviations of measurements were studied in male and female groups by various analytic methods, and the sex difference was examined statistically. The obtained data were compared with those of the Japanese and American standards by useing a Japanese adults standard polygon chart reported by lizuka and Ishikawa. Amongs of 58 measurements, 14 have been selected as statistically significant and clinically useful, and used to make a Korean adult standard polygon chart. The results obtained were as follows: 1. Standards for cphalometric analysis in Korean adults were obtained, and the polygon chart and cephalometric profilogram were also made by using the standards in order to apply to a clinical diagnosis. 2. The sex difference was recognized in linear measurements, but not in angular measurments. 3. In comparison with the American standards from Downs and Graber, the Korean showed significant differences in angle of convexity, mandibular plane angle, Y-axis angle, interincisal angle and lower incisor to mandibular plane angle. Thus, the Korean showed a more retruded chin position, convex facial type, than white people. 4. In comparison with the Japanese standards from Iizuka and Ishikawa, the Korean showed a significant similarity with the Japanese, especially in females. 5. Upper incisor to Huxely line angle, established as a new measurement, proved to be paralell to X-Y axis angle.

  • PDF

Usefulness of Rotation for Toric Soft Lenses Using Objective Refraction (타각적 굴절검사를 이용한 토릭 소프트 렌즈 회전 평가의 유용성)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.265-272
    • /
    • 2011
  • Purpose: The clinical usefulness of rotation evaluation using objective refraction in toric soft lenses fitting was investigated. Methods: Toric soft lenses were fitted for 32 subjects (64 eyes; mean age of 24.69 ${\pm}$ 1.65 years) with astigmatism and both eyes of each subject were fitted with toric soft lenses. Objective refraction-based lenses rotation was evaluated from refraction and over-refraction data by indirect calculating technique. These calculated data were compared with the measured data from slit lamp with direct measuring technique. Results: Orientation of toric soft lenses around zero position (within ${\pm}$ 5$^{\circ}$ vertical line) was investigated. The orientations to the direction of nose of measured and calculated values were 69.78% and 63.64%, respectively, which showed similar values between two techniques. Agreement frequency between measured and calculated values in the magnitude of lenses rotation 54.69% and 82.82% for 10$^{\circ}$ and 20$^{\circ}$ of vertical line, respectively. The 95% limits of agreement between calculation and measurement were from -10.08$^{\circ}$ to 12.65$^{\circ}$, and mean difference was 1.29$^{\circ}$ within ${\pm}$ 10$^{\circ}$. The result showed there was no significant difference (p = 0.1984) and high correlation (r = 0.56, p = 0.0004) between two techniques. But the 95% limits of agreement was widen in ${\pm}$ 20$^{\circ}$ of vertical line. The magnitude of lens rotation between two methods was 9.66 ${\pm}$ 6.16$^{\circ}$, 16.17 ${\pm}$ 12.38$^{\circ}$ and 10.58 ${\pm}$ 12.02$^{\circ}$ for normal, loose and tight fitted conditions. Conclusions: From the results with smaller difference between two techniques, it was found that higher availability of subjective over-refraction data can be used as a supplementary tool for subjective refraction. An application using objective refraction with direct measuring could be provide high success in prescription on toric soft lenses.

A Study on the Application of Drone Based Aeromagnetic Survey System to Iron Mine Site (드론 기반 항공자력탐사 시스템을 이용한 철광산 탐사 적용성 연구)

  • Min, Dongmin;Oh, Seokhoon
    • Journal of the Korean earth science society
    • /
    • v.38 no.4
    • /
    • pp.251-262
    • /
    • 2017
  • The system of magnetic exploration with a drone flight was constructed and applied to the iron mine site. The magnetic probe system installed on the drone used a sensor as Bartington's fluxgate type magnetometer, Mag639 and the A/D converter to collect magnetic intensity values on the tablet PC. The drone flight control module is a highly expandable Pixhawk with allowing 15 minutes of flight by loading 3kg. Experiments on the magnetic field interference range were performed to remove the erroneous effect from the drone with applying RTK GPS to obtain the magnetic intensity value at the accurate position. The accurate location information enabled to obtain the gradient measurement of magnetic field by measuring twice at different altitudes. Also, by using the terrain information, we could eliminate the terrain effect by setting the flight path to fly along the terrain. These results are in line with the field experiments using the nuclear proton magnetometer G-858 of Geometrics Co., Ltd, which adds to the reliability of the drone based aeromagnetic survey system we constructed.

Morphometric analysis of maxillary alveolar regions for immediate implantation

  • Park, Man-Soo;Park, Young-Bum;Choi, Hyunmin;Moon, Hong-Seok;Chung, Moon-Kyu;Cha, In-Ho;Kim, Hee-Jin;Han, Dong-Hoo
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.494-501
    • /
    • 2013
  • PURPOSE. The purpose of this study was to provide an actual guideline in determining the shape, diameter, and position of the implant in immediate implantation by the measurement of the thickness of facial and palatal plate, the thickness of cortical bone on the facial and palatal plate, the diameter of the root, and the distance between the roots in the cadavers. MATERIALS AND METHODS. The horizontal sections of 20 maxillae were measured and analyzed to obtain the average values. Resin blocks were produced and cut serially at 1 mm intervals from the cervical line to the root apex. Images of each section were obtained and the following measurements were performed: The thickness of the facial and palatal residual bone at each root surface, the thickness of the facial and palatal cortical bone at the interdental region, the diameter of all roots of each section on the faciopalatal and mesiodistal diameter, and the interroot distance. Three specimens with measurements close to the average values were chosen and 3-dimensional images were reconstructed. RESULTS. The thickness of the facial and palatal cortical bone at the interdental region in the maxilla, the buccal cortical bone was thicker in the posterior region compared to the anterior region. The interroot distance of the alveolar bone thickness between the roots increased from anterior to posterior region and from coronal to apical in the maxilla. CONCLUSION. In this study, the limited results of the morphometric analysis of the alveolar ridge using the sections of maxilla in the cadavers may offer the useful information when planning and selecting optimal implant for immediate implantation in the maxilla.

Difference of Lumbar Lordosis in Patients with Low Back Pain and Controls (일부 요통환자와 대조군의 요추 전만도 차이)

  • Kim Byung-Gon;Yi Seung-Ju;Kang Jeom-Cuk;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.185-190
    • /
    • 2000
  • Objectives: The purpose of this study was to compare the difference of Lumbar Lordosis Angle(LLA) between patients with Low Back Pain(LBP) and control groups. Methods: Questionnaires were completed by 40 adult LBP patients seeking physical therapy services and by 40 controls at the Department of Physical Therapy. Saejong Neurosurgical Clinic in Taegu city from October 1999 to March 2000. LLA was measured on lateral x-ray films in a standing position. The angle between a line parallel to the top of the first Lumbar(L1) and the top of the fifth Lumbar(L5) was defined LLA. Results: LLA of $29.88^{\circ}$ for LBP patients was a statistically significant decrease from that of $35.31^{\circ}$ for controls in the difference of lumbar lordosis(p<0.01). There were statistically significant differences between senders in patient groups. Females$(32.32^{\circ})$ had significantly greater angles than males$(27.32^{\circ})$(p<0.05), while $36.63^{\curc}$ for female was also greater than $34.12^{\circ}$ for male in the controls. No significant difference was found between age. In patient groups, $27.95^{\circ}$ for below age 40 was a smaller than $32.32^{\circ}$ for above, however, $35.82^{\circ}$ for below age 40 was a little greater than $34.27^{\circ}$ for above in controls. Patients in a sitting posture had greater LLA$(31.35^{\circ}$ than those standing$(28.93^{\circ})$, however values for controls were similar to each other. Conclusion: Results from this study indicate that distinct differences exist among patients and controls and gender, whereas little difference exists in age and working posture.

  • PDF

The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System (microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구)

  • Cho, Young-K.;Park, Sung-Y.;Choi, Jin-H.;Kim, Hung-J.;Kim, Woo-C.;Loh, John-J.K.;Kim, Joo-Y.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • There are three different types of gynecological applicator sets available in microSelectron-high dose-rate(HDR) System by Nucletron; standard applicator set(SAS), standard shielded applicator set(SSAS), and Fletcher-Williamson applicator set(FWAS). Shielding effect of a SAS without shielding material was compared with that of a SSAS with shielding material made of stainless steel(density ${\varrho}=8,000kg/m^3$) at the top and bottom of each ovoid, and of a FWAS with shielding material made of tungsten alloy(density ${\varrho}=14,000kg/m^3$ at the top and bottom of each ovoid. The shielding effects to the rectum and bladder of these two shielded applicator sets were to be measured at reference points with an ion chamber and specially designed supporting system for applicator ovoids inside of the computerized 3-dimensional water phantom. To determine the middle point of two ovoids the measurement was performed with the reference tip of ion chamber placed at the same level and at the middle point from the two ovoids, while scanning the dose with the ion chamber on each side of ovoids. The doses to the reference points of rectum were measured at 20(Rl), 25(R2), 30(R3), 40(R4), 50(R5), and 60(R6) mm located posteriorly on the vertical line drawn from M5(the middle dwell position of ovoid), and the doses to the bladder were measured at 20(Bl), 30(B2), 40(B3), 50(B4), and 60(B5) mm located anteriorly on the vertical line drawn from M5. The same technique was employed to measure the doses on each reference point of both SSAS and FWAS. The differences of measured rectal doses at 25 mm(R2) and 30 mm(R3) between SAS and SSAS were 8.0 % and 6.0 %: 25.0% and 23.0 % between SAS and FWAS. The differences of measured bladder doses at 20 mm(Bl) and 30 mm(B2) between SAS and SSAS were 8.0 % and 3.0 %: 23.0 % and 17.0 % between SAS and FWAS. The maximum shielding effects to the rectum and bladder of SSAS were 8.0 % and 8.0 %, whereas those of FWAS were 26.0 % and 23.0 %, respectively. These results led to the conclusion that FWAS has much better shielding effect than SSAS does, and when SSAS and FWAS were used for gynecological intracavitary brachytherapy in microSelectron-HDR system, the dose to the rectum and bladder was significantly reduced to optimize the treatment outcome and to lower the complication rates in the rectum and bladder.

  • PDF

Morphological Variations in Relation to Geographical Distribution of Pond Smelt, Hypomesus olidus Pallas (한국산 빙어의 지리적 형태변이에 대하여)

  • Ryu Bong Suk;LEE Kyung Ro
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.3
    • /
    • pp.179-188
    • /
    • 1981
  • The authors made an investigation concerning the geographical distribution and some major differentiations in morphological characteristics associated with the each habitat, of the pond smelt, Hypomesus olidus, which was introduced into Korea more than 50 years ago. Major characteristics utilized for the comparison study were upper jaw (maxillary), number of fin rays, scale structure, vertebral count, number of pyloric caeca, number of gill rakers, and the relative measurements of these and other internal characters. 1. The main areas of natural distribution are Paro Lake, Soyang Lake, Han River, Euirim Lake, and Ogjeong Lake (or Unam Lake) and the tributaries of these waters. 2. Morphological variations varied when the mean values of measurements from each area were compared with the standard measurement value by mosaic comparison, and in some instances a significant variation was found. 3. The most significant variations were found in the number of fin rays of pectoral and anal fins; the lengths from the tip of snout to the origin of pectoral fin, from snout to ventral fin, and from snout to anal fin, relative to standard body length; eye depth relative to head length; upper jaw: the number of pyloric caeca and the scale structure. Variations, on the other hand, by each habitat were not clear in the numbers of ventral and dorsal fin rays, gill rakers, vertebrae and lateral line scale : and the depth of caudal peduncle and distance from the tip of snout to the origin of dorsal fin relative to standard body length. 4. The scales of pond smelt showed some differences in the shape of scales, the shape and position of the focus and the number of ridges according to the scale positions on the body. No radii were present. The relations between longitudinal and transverse diameters of the scale suggest that the pond smelts of Soyang Lake and Un-am Lake are closely related, and those of Han River and Euirim Lake are also closely related. 5. The geographical variations in morphology of the pond smelt seem to have resulted from the variations in turbidity, water temperature, salinity (rather conductivity) and currents. 6. From the results obtained, it may be concluded that such factors as supramaxillary, relation between scale length and its breadth, number of caudal vertebrae and eye depth relative to head length may be used as the key characters for the classification of geographical varieties of Pond smelt.

  • PDF

Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories (동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석)

  • Kang, Min-Young;Lee, Bo-Ram;Kim, You-Hyun;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • The aim of the study is to analyze the dose delivery error depending on the depth variation according to target positions and arc trajectories by comparing the simulated treatment planning with the actual dose delivery in conformal arc therapy. We simulated the conformal arc treatment planning with the three target positions (center, 2.5 cm, and 5 cm in the phantom). For the experiments, IMRT body phantom (I’mRT Phantom, Wellhofer Dosimetry, Germany) was used for treatment planning with CT (Computed Tomography, Light speed 16, GE, USA). The simulated treatment plans were established by three different target positions using treatment planning system (Eclipse, ver. 6.5, VMS, Palo Alto, USA). The radiochromic film (Gafchromic EBT2, ISP, Wayne, USA) and dose analysis software (OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany) were used for the measurement of the planned arc delivery using 6 MV photon beam from linear accelerator (CL21EX, VMS, Palo Alto, USA). Gamma index (DD: 3%, DTA: 2 mm) histogram and dose profile were evaluated for a quantitative analysis. The dose distributions surrounded by targets were also compared with each plans and measurements by conformity index (CI), and homogeneity index (HI). The area covered by 100% isodose line was compared to the whole target area. The results for the 5 cm-shifted target plan show that 23.8%, 35.6%, and 37% for multiple conformal arc therapy (MCAT), single conformal arc therapy (SCAT), and multiple static beam therapy, respectively. In the 2.5 cm-shifted target plan, it was shown that 61%, 21.5%, and 14.2%, while in case of center-located target, 70.5%, 14.1%, and 36.3% for MCAT, SCAT, and multiple static beam therapy, respectively. The values were resulted by most superior in the MCAT, except the case of the 5 cm-shifted target. In the analysis of gamma index histogram, it was resulted of 37.1, 27.3, 29.2 in the SCAT, while 9.2, 8.4, 10.3 in the MCAT, for the target positions of center, shifted 2.5 cm and 5 cm, respectively. The fail proportions of the SCAT were 2.8 to 4 times as compared to those of the MCAT. In conclusion, dose delivery error could be occurred depending on the target positions and arc trajectories. Hence, if the target were located in the biased position, the accurate dose delivery could be performed through the optimization of depth according to arc trajectory.