• Title/Summary/Keyword: line impedance

Search Result 938, Processing Time 0.039 seconds

A.C. Impedance Properties on $RuO_2$-Based Thick Film Resistors. ($RuO_2$계 후막저항체의 교류 임피던스특성)

  • Koo, Bon-Keup;Kim, Ho-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.215-220
    • /
    • 1990
  • A.C. impedance properties of $RuO_2$ based thick film resistors which having different resistivity value (DuPont 1721 : $100{\Omega}$/ sq., 1741 : $10K{\Omega}$/sq.) were investigated using by impedance analyzer. In case of lower resistivity 1721 system, the complex impedance was composed nearly R component for all speciman sintered at above $600^{\circ}C$, and the frequency dependancy on impedance was not affected very much up to 5MHz and again gradually increase with increasing the frequency. In case of higher resistivity 1741 resistor system, impedance properties were very depandant on sintering temperature. When sintering temperature was $600^{\circ}C$, the complex impedance plot shows a vertical line, which correspond to lone capacitance equivalant circuit, and the impedance linearly decreased with increasing frequency. In case of speciman sintered at $700-900^{\circ}C$, the complex impedance plot shows semi-circular are correspond to a lumped RC combination, and the impedance shows constant value to 5MHz, again decreased with increasing frequency. But the complex impedance behavior of speciman sintered at $1000^{\circ}C$ was shows the equivalent circuit correspont to parallel combined LCR component, and the impedance was not varied with frequency.

  • PDF

A Study on Correction of the Protective Relay Equipped in the Dedicated Line Used for Connecting Distributed Generators to Power Network (분산전원 계통 연계 전용선로에 설치된 보호 계전기의 정정에 관한 연구)

  • Jeong, Jong-Chan;Jang, Sung-Il;Choi, Don-Man;Kim, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.141-144
    • /
    • 2002
  • This paper describes the correction of the protective relay equipped in the dedicated line used for connecting distributed generators (DG) to power grid. The fault current measured in a relaying point might be changed according to the fault conditions. Generally, the fault current of the line to line fault or the line to ground fault at the dedicated line is much higher than the protective set value due to the large fault level. However. when the high impedance fault is occurred in the dedicated line, we may not detect it because its fault level can be lower than the generating capacity of DG. And, the protective relay with conventional set value may generate a trip signal for insertion of DG due to the large transient characteristics of generators. Through the various simulations such as the fault in the dedicated line and the insertion of DG, we show that it would be necessary to modify the protective relay set value for detecting the high impedance fault occurred in the dedicated line and for preventing the mis-operation of protective relay caused by the insertion of DG.

  • PDF

Voltage-Controlled Artificial Transmission Line Employing Periodically Loaded Diodes for Application to On-Chip Matching Components on MMIC (MMIC용 온칩 정합 소자에의 응용을 위한 주기적 배열 다이오드 구조를 이용한 전압 제어형 전송 선로)

  • Yun, Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.1
    • /
    • pp.7-14
    • /
    • 2008
  • In this paper, we propose VATL(Voltage-controlled Artificial Transmission Line) employing periodically loaded diodes for application to on-chip matching components on MMIC. Compared with conventional microstrip line, the VATL showed a much shorter wave length due to periodic capacitance of diodes, and the characteristic impedance of the VATL was easily controlled bγ changing supplied voltage. Concretely, the characteristic impedance of the VATL was changed from $80{\sim}20{\Omega}$ in a range of $0{\sim}1.05V$ and the VATL showed a wavelength of 1.5mm at 20GHz, while conventional microstrip line showed a wavelength of 5.3mm at the same frequency. Using the VATL, a ${\lambda}/4$ impedance transformer was fabricated on GaAs MMIC for application to on-chip matching components on MMIC. Using the ${\lambda}/4$ impedance transformer made it possible to perform impedance matching between RF components with various characteristic impedance of $30{\sim}100{\Omega}$ by adjusting applied Voltage.

Design of a Transmission Line using Defected Ground Structure and Artificial Dielectric Substrate (결함접지구조와 가유전체 기판구조를 결합한 전송선로의 설계)

  • Kwon, Kyunghoon;Lim, Jongsik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3474-3481
    • /
    • 2013
  • In this work, a new high frequency transmission line structure combined with defected ground structure (DGS) and artificial dielectric substrate (ADS) structure is proposed. DGS patterns give add the additional inductance to transmission lines and results in the increased characteristic impedance for a given line width. To the contrary, ADS presents increased capacitance and reduced line impedance. So both play a role in reducing the length of transmission lines commonly, but in preserving the line impedance complementarily. This means that the length of transmission lines can be reduced furtherly by DGS and ADS without a critical change of line width compared to the cases when one of DGS and ADS is used only. As examples, $35{\sim}100{\Omega}$ transmission lines having DGS and ADS are designed, fabricated, measured, and compared to the simulation results. A good agreement between the simulated and measured line impedances is presented. In addition, the physical lengths of the proposed transmission lines are only 55.4~76.9% of those of the normal microstrip lines for the same electrical lengths.

Analysis of Symmetric Coupled Line with Crossbar Embedded Structure for Improved Attenuation Characteristics on the Various Lossy Media (다양한 매질내의 손실특성 개선을 위한 크로스바 구조의 대칭 결합선로에 대한 해석)

  • Kim, Yoon-Suk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.8
    • /
    • pp.61-67
    • /
    • 2010
  • A characterization procedure for analyzing symmetric coupled MIS(Metal-Insulator-Semiconductor) transmission line is used the same procedure as a general single layer symmetric coupled line with perfect dielectric substrate from the extraction of the characteristic impedance and propagation constant for even- and odd-mode. In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite-Difference Time-Domain (FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Symmetric coupled MIS transmission line parameters for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency-dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.

A Study on the Improved Protective Relaying Algorithm Applied in the Linked System Interconnecting Wind Farm with the Utilities (풍력발전단지 연계 전용선로 보호계전방식의 향상에 대한 연구)

  • 장성일;김광호;권혁완;김대영;권혁진
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.675-683
    • /
    • 2003
  • This paper describes the correction strategy of an overcurrent relay applied in the linked line for interconnecting wind farm with utility power networks in order to improve the capability of a fault detection. The fault current measured in a relaying point might vary according to the fault conditions. Generally, the current of the line to line fault or the line to ground fault in the linked line is much higher than the set value of protective relay due to the large fault level. However, when the high impedance fault occurs in the linked line, we can't detect it by conventional set value because its fault level may be lower than the generating capacity of wind farm. And, the protective relay with conventional set value may generate a trip signal for the insertion of wind turbine generators due to the large transient characteristics. In order to solve above problems and improve protective relaying algorithms applied in the linked line, we propose a new correction strategy of the protective relay in the linked line. The presented method can detect the high impedance fault which can't be detected by conventional relay set value and may prevent the mis-operation of protective relay caused by the insertion of wind farm.

Contigency Ranking Technique Using Line Capacity Calculation Method (선로용량 산정법을 이용한 상정사고 선택)

  • Park, Kyu-Hong;Jung, Jai-Kil;Hyun, Seung-Bum;Lee, In-Yong;Jung, In-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.285-288
    • /
    • 2000
  • This paper presents a technique for contingency ranting using line capacity calculation method and outage distribution factors(LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranting, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. ( $Z_r$/ $Z_s$=1) The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

A study on the improvement of Drive circuit in the Power Line Communication (전력선 통신환경에서의 구동회로 개선에 관한 연구)

  • Lim, Seung-Ha
    • 전자공학회논문지 IE
    • /
    • v.44 no.4
    • /
    • pp.30-34
    • /
    • 2007
  • The Channel environment is poor in the power line communication because power line proposed power supply use a communication medium. In this paper, we designed gate drive circuit used coupler reducing the signal diminution for the good communication. We analyzed receiving and transmitting operation of the coupler and designed the drive circuit with the suitable impedance. As a result, we improved the environment of impedance variation due to the inter reaction of many electron products. So, to improve BER(45%) enabled us to communicate smoothly in power line communication.

Contigency Ranking Technique Using New Line Capacity (새로운 선로용량을 고려한 전력계통의 상정사고 선택)

  • Park, Kyu-Hong;Cho, Yang-Haeng
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.95-98
    • /
    • 2000
  • This paper presents a technique for contingency ranking using line capacity calculation method and outage distribution factors (LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranking, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

Estimation and Measurement of the Traction return current on the electrified Gyeongbu line.

  • Kim, Y.K.;Yang, D.C.;Han, M.S.;Ryu, C.K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.99.5-99
    • /
    • 2001
  • This study presents a simulation of the traction return current based on $2{\times}25kV$ power supply system in order to determine the impedance bond intensity of impulse type track circuit on the electrified Gyeongbu line. The results of the simulation enables us to measure the precise intensity of catenary current that returns to the substation through KTX (Korean Train Express) operated by $2{\times}25kV$ power supply system with common earth network. The combination of $2{\times}25kV$ and common earth network established on the electrified Gyeongbu line for the first time in Korea. We show that the relationships among the traction return current, earth current, and catenary current, and catenary current can be applied to this line in order to determine the optimal impedance bond intensity ...

  • PDF