• Title/Summary/Keyword: line comparison

Search Result 1,739, Processing Time 0.034 seconds

Structural Design for Performance Improvement of Line Center (라인센터의 성능향상을 위한 구조설계)

  • Cheong, Seon-Hwan;Choi, Seong-Dae;Kweon, Hyun-Kyu;Choi, Un-Don;Shon, Jae-Yool
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.2 no.3
    • /
    • pp.76-83
    • /
    • 2003
  • Recently, the field of the engineering has been studied about optimum design continuously. Verified data by comparison with simulation and dynamic characteristic analysis enables the design of a machine tool to be modified easily and effectively concerning to the mode shape of the vibration. Especially, BC-500 Line Center has got some problems causing vibration which mainly come from Column and ATC part. So it is necessary to solve those problems by the two kinds of method such as changing structural design and reinforcing with ribs. In this paper, column and ATC part of BC-500 Line center are modified by an optimum design by the analysing method of FEM to avoid vibration. As a result, a more stable machine tool was designed by this simulation as optimum condition.

  • PDF

A Simulation Study for Comparison and Evaluation of Alternative Plans for the Productivity Improvement (생산성 향상을 위한 대안들의 비교 평가 시뮬레이션 사례연구)

  • 김원경
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.1
    • /
    • pp.51-62
    • /
    • 2001
  • For the productivity improvement, it is necessary to analyze problem of the system and evaluate alternative plans. But, it if hard to experiment and evaluate alternative plans in real existing system. Therefore, it is necessary to synthetically analyze and evaluate alternative plans using simulation and statistical analysis method. In this case study, as a simulation language, Promodel is used to compare and evaluate four alternatives which are considered to improve the productivity of an object system. The object system is constituted of a pretreatment line and a painting line. The purpose of this study is to analyze whether the decrease of the down time in pretreatment line can be effective to the productivity improve comparing with exiting system and other alternatives. The other purpose is to choose an alternative that has the best productivity improvement. The results of the simulation show that the possibility of improvement in productivity by decreasing the down time of pretreatment line. Two-Stage Bonferroni Procedure is used to choose the best alternative.

  • PDF

Micro patterning of conductor line by laser induced forward transfer(LIFT) (LIFT 방법에 의한 전도성 미세 패터닝 공정 연구)

  • 이제훈;한유희
    • Laser Solutions
    • /
    • v.2 no.3
    • /
    • pp.52-61
    • /
    • 1999
  • The laser induced forward transfer(LIFT) technique employs a pulsed laser to transfer parts of a thin metal film from an optically transparent target onto an arbitrary substrate in close proximity to the metal film on the target. In this work, a two-step method, the combination of LIFT process, in which a Au film deposited on the $Al_2$O$_3$ substrate by Nd:YAG laser and subsequent Au electroless metal plating on the by LIFT process generated Au seed, was presented. The influence of laser parameters, wavelength, laser power, film thickness and overlap ratio of pulse tracks, on the shapes of deposit and conductor line after electroless plating is experimentally studied. As a results, the threshold power densities for ablation, deposition and metallization were determined and comparison of threshold value between the wave length 1064nm and the second harmonic generated 532nm. In odor to determine a possible application in the electronic industry, a smallest conduct spot size, line width and isolated line space were generated.

  • PDF

The development of FE-based on-line model for the precise prediction of work roll thermal profile in hot strip rolling (열간 압연 시 워크 롤의 열 변형 정밀 예측을 위한 유한요소법 기반의 온라인 모델 개발)

  • Choi J. W.;Huang H. D.;Lee J. H.;Hwang S. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.08a
    • /
    • pp.329-335
    • /
    • 2004
  • An, FE-based, on-line model is presented for the rapid and precise prediction of roll thermal profile in hot strip rolling. The validity of the model is demonstrated through comparison with FE-based off-line model which was verified by measurements. Also demonstrated is its capability of reflecting the effect of diverse process variables.

  • PDF

Verification of Underground Distribution Line Modeling with Field Test (실증시험을 통한 지중배전선로 모델링 기법 검증 연구)

  • Yun, Chang-Sub;Lee, Jae-Bong;Kim, Byong-Suk;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2091-2097
    • /
    • 2007
  • This paper described the verification of modeling technique of underground distribution from comparison between field test and simulation. It needs more exact transient phenomenon analysis model to establish lightning protection of underground distribution line. Although, there were a lot of transient phenomenon researches, nobody could has verified the confidence of modeling from field tests in interior until now. So, simulation model verified field test is needed to analyse transient phenomenon of underground distribution system. The examination must be accomplished in many different condition before suggesting these verified analysis model. In this paper, the conditions were examined and the various data results on the different line composition was compared with the EMTP simulation, when the lightning impulse test was accomplished at underground distribution line. Also the value between field test and simulation was very closed and the method of modeling has demonstrated confidence, when the method is used to analyse domestic transient phenomenon of underground distribution.

Modeling and simulation on an IR absorbing structure with the cascaded transmission line model (전송선 이론에 의한 적외선 흡수 구조체의 흡수율 모의시험)

  • Park, Seung-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1725-1729
    • /
    • 2013
  • In this paper, the modeling and simulation of infrared absorption in an infrared absorbing structure with the cascaded transmission line model were carried out. Each layer in the infrared absorbing structure can be modeled as a characteristic impedance of the cascaded transmission line model. The simulation results show that the cavity thickness to get a maximum absorption should be less than a quarter wavelength, which is somewhat different from prevalent thickness. It can be assured that the sheet resistance of an absorbing layer to get a maximum absorption is $377{\Omega}/{\square}$, that the thickness of the absorbing layer dose not affect the spectral characteristics of absorption. It is also shown that the thickness of the active layer is not critical to the IR absorption. It can also be assured that the validation of this modeling is proved in comparison with the previous results from similar absorbing structures.

3-Dimensional Numerical Analysis for Thermal Stratification in Surgeline in Nuclear Power Plant (원전 밀림관 열성층의 3 차원 수치해석)

  • Kim, Young-Jong;Kim, Maan-Won;Ko, Eun-Mi
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.729-734
    • /
    • 2008
  • A thermal stratification may occur in the horizontal parts of the surge line during operating transients of the pressurizer, which produces relatively high fatigue usage factor. Heat-up transient is the most severe case among the transient conditions. In this study, to study the relationship between the magnitude of thermal stratification and the length of vertical part of the surge line, some parametric fluid-structure interaction (FSI) analyses with different length variables of the vertical part of the surge line were performed for plant heat-up transient condition by using 3-dimensional numerical analysis. The conservativeness of the traditional finite element model for thermal stratification analysis based on the conservative assumption in the surge line was also discussed by comparison of the results of 3-dimensional transient FSI analysis of this study. Stresses calculated with 3-dimensional transient model were considerably reduced comparing with the traditional analysis.

  • PDF

Microstrip Bandpass Filter Using Stepped-Impedance Coupled-Line Hairpin Resonators with Enhanced Stopband Performance

  • Lee, Hye-Min;Ha, Jung-Hyun;Wang, Xu-Guang;Cho, Young-Ho;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • In this paper, we propose a microstrip bandpass filter using stepped-impedance coupled-line hairpin resonators. The stepped-impedance coupled-line hairpin resonator has extended harmonic suppression in comparison with a conventional hairpin resonator due to transmission zero and the movement of harmonic frequencies resulting from the stepped-impedance characteristic. A high-pass type impedance/admittance inverter is employed in order to improve the lower frequency skirt characteristics of the passband. A 4-pole bandpass filter is designed and fabricated at 1.8 GHz. The measured results show the excellent attenuation performance at the stopband which is greater than 30 dB up to 10 GHz.

A Modeling and Simulation Implementation on the Power Line Disturbances by Loss of Contact for the High-Speed Railway Vehicle (고속전철 주행시 이선에 따른 전원외란 현상 모델링 및 시뮬레이션 구현)

  • Kim, Jae-Moon;Kim, Yang-Soo;Chang, Chin-Young;Gimm, Yoon-Myoung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1137-1142
    • /
    • 2008
  • In this paper, an effect on power conversion unit in high-speed railway vehicle by loss of contact between a catenary system and pantograph suppling electrical power to high-speed railway vehicle are investigated. One of the most important needs accompanied by increasing the speed of high-speed railway vehicle is reduced that arc phenomenon by loss of contact brings out EMI. in case of high-speed railway vehicle using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occur. To analysis the effect on loss of contact, it is necessary electrical modeling system between the contact line and the pantograph according to the loss of contact. Therefore analytical model of a contact line and a pantograph is constructed to simulate the behaviour of loss of contact. The reliability of the modeling system is verified by simulation implementation on kinds of loss of contact.

  • PDF

Measurement and Analysis of Line Impedance in Underground Cables (지중케이블 선로 임피던스 실측 및 분석)

  • Ha, C.W.;Kim, J.N.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.205-207
    • /
    • 2003
  • The line impedance is important data that is applied in all analysis fields of electric power system like power flow, fault current, stability and relay calculation etc. Usually, impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and earth resistance. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Therefore, the line impedance were measured for this study in an actual power system of underground cables, and were analyzed by a generalized circuit analysis program EMTP for comparison with the measured value. These analysis result is considered to become foundation of impedance calculation for underground cable.

  • PDF