• Title/Summary/Keyword: line center

Search Result 4,313, Processing Time 0.034 seconds

Development of a High-speed Line Center using Linear Motor Feed System and High-speed Spindle System (리니어 모터 이송계와 고속 주축을 적용한 초고속 라인 센터 개발)

  • 문홍만;백영종;조현택;최대봉
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.107-112
    • /
    • 2003
  • The recent machine tools are requested so high-quality processing and productivity increasing. Therefore, it is so necessary to develop technology for high-speed and high-precision. This thesis touches on the development of high speed and intellectual line center. At first, the line center is necessary that strong structure, compact structure and light weight design for high-speed processing and transfer. So, it is necessary that examination of new materials and structures for light-weight and control devices for precision processing. So, it is going to make mention of the process of 1st model production for the above-mentioned based on test model production and evaluation.

  • PDF

Prediction of unresponsiveness to second intravenous immunoglobulin treatment in patients with Kawasaki disease refractory to initial treatment

  • Seo, Euri;Yu, Jeong Jin;Jun, Hyun Ok;Shin, Eun Jung;Baek, Jae Suk;Kim, Young-Hwue;Ko, Jae-Kon
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.10
    • /
    • pp.408-413
    • /
    • 2016
  • Purpose: This study investigated predictors of unresponsiveness to second-line intravenous immunoglobulin (IVIG) treatment for Kawasaki disease (KD). Methods: This was a single-center analysis of the medical records of 588 patients with KD who had been admitted to Asan Medical Center between 2006 and 2014. Related clinical and laboratory data were analyzed by univariate and multivariate logistic regression analyses. Results: Eighty (13.6%) of the 588 patients with KD were unresponsive to the initial IVIG treatment and received a second dose. For these 80 patients, univariate analysis of the laboratory results obtained before administering the second-line IVIG treatment showed that white blood cell count, neutrophil percent, hemoglobin level, platelet count, serum protein level, albumin level, potassium level, and C-reactive protein level were significant predictors. The addition of methyl prednisolone to the second-line regimen was not associated with treatment response (odds ratio [OR], 0.871; 95% confidence interval [CI], 0.216-3.512; P=0.846). Multivariate analysis revealed serum protein level to be the only predictor of unresponsiveness to the second-line treatment (OR, 0.160; 95% CI, 0.028-0.911; P=0.039). Receiver operating characteristic curve analysis to determine predictors of unresponsiveness to the second dose of IVIG showed a sensitivity of 100% and specificity of 72% at a serum protein cutoff level of <7.15 g/dL. Conclusion: The serum protein level of the patient prior to the second dose of IVIG is a significant predictor of unresponsiveness. The addition of methyl prednisolone to the second-line regimen produces no treatment benefit.

Estimation of Voltage Drop in Low Voltage Distribution Line (배전계통 저압배전선 전압강하 추정방법)

  • Kim, T.E.;Kim, C.S.;Kim, J.E.;Son, J.M.;Park, J.K.;No, D.S.;Kim, K.H.;Cho, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.118-120
    • /
    • 2002
  • Voltage drop of low voltage distribution line is closely related with proper voltage regulation. It depends on the voltage drop of pole transformer, low voltage distribution line, and low voltage customer entrance line. Using above voltage drop factors, we proposes an estimation method of voltage drop in low voltage distribution line. Proposed method has been applied to a 22.9kV practical distribution system.

  • PDF

Exciting High Frequency Oscillations in a Coaxial Transmission Line with a Magnetized Ferrite

  • Ahn, J.-W.;Karelin, S.Y.;Kwon, H.-O.;Magda, I.I.;Sinitsin, V.G.
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.460-465
    • /
    • 2015
  • The paper presents methodologies and results concerning one- and two-dimensional numerical modeling of radio frequency oscillations in a coaxial transmission line fed with a short pulse of electric current. The line is partially filled with a ferrite material, magnetized longitudinally close to saturation. The 2D model has permitted analyzing, for the first time in the art, the spatial structure and dynamics of the wave field within the radially non-uniform cross-section planes of the non-linear and dispersive guiding structure. This opens ways for optimizing size parameters of the line and the extent to which it is filled with the ferromagnetic material, thus increasing the line's electric strength and intensity of the r.f. oscillations.

EXPERIMENTAL STUDY OF THE CENTER OF RESISTANCE OF A MAXILLARY CANINE USING LASER SPECKLE INTERFEROMETRY AND HOLOGRAPHIC INTERFEROMETRY (상악 견치의 저항 중심에 관한 Laser speckle interferometry와 holographic interferometry볼 이용한 실험적 연구)

  • Lee, Soo Ryong
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.289-308
    • /
    • 1988
  • The center of resistance is a important determining factor of tooth movement pattern. Laser speckle interferometry, recently developed for noninvasive measurement of small displacements (microns), was used to detect the center of resistance of a maxillary canine which has normal tooth axis and distal curved root in dry human skull. Laser holographic interferometry was used to verify the results of laser speckle interferometry The following result were obtained; 1. In measurement of the degree of rotation, center of resistance was localized when the traction line passed 4.4/18.0 level from alveola crest to root apex. 2. In measurement of the degree of tipping, center of resistance was localized when the traction line passed 4.6/18.0 level from alveola crest to root apex. 3. In holographic determination, the center of resistance was observed when the traction line passed between 3mm to 6mm level from alveola crest to root apex, therefore the results using laser speckle interferometry was coincided with holographic results.

  • PDF

A Data-line Sharing Method for Lower Cost and Lower Power in TFT-LCDs

  • Park, Haeng-Won;Moon, Seung-Hwan;Kang, Nam-Soo;Lee, Sung-Yung;Park, Jin-Hyuk;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.531-534
    • /
    • 2005
  • This paper presents a new data line sharing technique for TFT-LCD panels. This technique reduces the number of data driver IC's to half by having two adjacent pixels share the same data line. This in turn doubles the number of gate lines, which are integrated directly on the glass substrate of amorphous silicon for further cost reduction and more compactness. The proposed technique with new pixel array structure was applied to 15.4 inch WXGA TFT-LCD panels and has proven that the number of driver IC's were halved with nearly 41% circuit cost reduction and 5.3% reduction in power consumption without degrading the image quality.

  • PDF

A Study on the Patterns of Men's Drawers Panties (남성 드로즈(drawers) 팬티의 패턴 분석)

  • Lee, Jung-Jin;Lee, Jung-Soon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.18 no.1
    • /
    • pp.169-181
    • /
    • 2016
  • This study analyzed the characteristics and patterns of men's drawers panties to get basic data for their design. For this, drawers panties in 7 different brands (4: domestic brands, 3: imported brands) in terms of a front-center shape were collected, and the shape of men's drawers panties, characteristics of the materials, dimensions & type of patterns by the part and front-center patterns were analyzed. The study results found the followings: First, in terms of the shape of men's drawers panties, the front-center part were designed to rest the penis and scrotum in a natural and comfortable manner without a pee slit. They were seamless on the sides except for one product with side seams. Second, the drawer panties were made of elastic polyurethane materials. Specifically, domestic brand items used warm, elastic and durable nylon, polyester and rayon and polyurethanes while imported brands were mostly made of absorbent and sanitary polyurethanes. Third, regarding a size of drawer panties by part, imported brands were large in waist circumference. In terms of waist breadth at the front center, there was difference depending on an oval type. In addition, the front length at the front center differed by product, revealing difference in three-dimensional effect at the front center. The side length also differed greatly by product, which means that there might be a great difference in wear comfort. Fourth, in terms of the patterns of men's drawers panties, there was difference in side seams, center back seam and front-center patterns. Among a total of 7 products, only one product had side seams, and center back seams were found in two products only. Fifth, in terms of front-center patterns, the drawer panties can be divided into three types, creating three-dimensional effect not to give any pressure on the crotch: i) the cutting line only at the bottom of the front center part where the penis is rested, ii) puff created at the front center by adding a transverse line to the center line, iii) cutting transverse line to separate the penis from the testicles.

  • PDF

UV-Nanoimprint Lithography Using Fluorine Doped Diamond-Like Carbon Stamp (불화 함유 다이아몬드 상 탄소 스탬프를 사용하는 UV 나노 임프린트 리소그래피)

  • Jeong, Jun-Ho;Ozhan, Altun Ali;Rha, Jong-Joo;Choi, Dae-Geun;Kim, Ki-Don;Choi, Jun-Hyuk;Lee, Eung-Sug
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.109-112
    • /
    • 2006
  • A fluorine-doped diamond-like carbon (F-DLC) stamp which has high contact angle, high UV-transmittance and sufficient hardness, was fabricated using the following direct etching method: F-DLC is deposited on a quartz substrate using DC and RF magnetron sputtering, PMMA is spin coated and patterned using e-beam lithography and finally, $O_2$ plasma etching is performed to transfer the line patterns having 100 nm line width, 100 nm line space and 70 nm line depth on F-DLC. The optimum fluorine concentration was determined after performing several pre-experiments. The stamp was applied successfully to UV-NIL without being coated with an anti-adhesion layer.

  • PDF

Sapphire Based 94 GHz Coplanar Waveguide-to-Rectangular Waveguide Transition Using a Unilateral Fin-line taper (평면형 Fin-line 테이퍼를 이용한 사파이어 기반의 94 GHz CPW-구형 도파관 변환기)

  • Moon, Sung-Woon;Lee, Mun-Kyo;Oh, Jung-Hun;Ko, Dong-Sik;Hwang, In-Seok;Rhee, Jin-Koo;Kim, Sam-Dong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.10
    • /
    • pp.65-70
    • /
    • 2008
  • We design and fabricate the 94 GHz Coplanar waveguide(CPW)-to-rectangular waveguide transition that is transmits signal smoothly between the CPW, which is a popular transmission line of the planar circuits, and rectangular waveguide for the 94 GHz transceiver system. The proposed transition composed of the unilateral fin-line taper and open type CPW-to-slot-line transition is based on the hard and inflexible sapphire for the flip-chip bonding of the planar MMICs using conventional MMIC technology. We optimize a single section transition to achieve low loss by using an EM field solver of Ansoft's HFSS and fabricate the back- to-back transition that is measured by Anritsu ME7808A Vector Network Analyzer in a frequency range of $85{\sim}105$ GHz. From the measurement and do-embedding CPW with 3 mm length, an insertion and return loss of a single-section transition are 1.7 dB and more an 25 than at 94 GHz, respectively.