• Title/Summary/Keyword: line camera

Search Result 820, Processing Time 0.028 seconds

Fabrication of waveguide using UV Ar-ion laser direct writing (Laser Direct Writing 방법을 이용한 광도파로 제작)

  • Kang H. S.;Suh J.;Lee J. H.;Kim J. O.
    • Laser Solutions
    • /
    • v.8 no.1
    • /
    • pp.9-18
    • /
    • 2005
  • The laser direct writing method using a UV Argon-ion laser is studied for fabrication of waveguide. The laser direct writing system is constructed with a vision camera, a xy-stage, a motion controller and the delivery components of a laser beam. The UV Argon-ion laser has wavelength range of $333.6\~363.8$ nm. A photo-active UV curable polymer for a planar light-wave circuit(PLC) of single mode is used. This polymer is irradiated by Argon-ion laser and developed by a solvent after a post-baking. The optimum laser direct writing condition is obtained experimentally by changing various process parameters such as laser power, writing speed and focal length. The propagation and coupling loss of a optical waveguide was measured as 1dB/cm and 0.6dB/cm, respectively. Also, the minimum width of waveguide of $100{\mu}m$(ZPLW-207) is obtained. Finally, the waveguides of line, bend and branch type are successfully fabricated.

  • PDF

Vortex-induced vibration characteristics of a low-mass-ratio flexible cylinder

  • Quen, Lee Kee;Abu, Aminudin;Kato, Naomi;Muhamad, Pauziah;Siang, Kang Hooi;Hee, Lim Meng;Rahman, Mohd Asamudin A
    • Structural Engineering and Mechanics
    • /
    • v.75 no.5
    • /
    • pp.621-631
    • /
    • 2020
  • A laboratory experiment is conducted is to investigate the behaviour of a low-mass-ratio and high aspect ratio flexible cylinder under vortex-induced vibration (VIV). A flexible cylinder with aspect ratio of 100 and mass ratio of 1.17 is towed horizontally to generate uniform flow profile. The range of Reynolds number is from 1380 to 13800. Vibration amplitude, in-line and cross-flow frequency response, amplitude trajectory, mean tension variation and hydrodynamic force coefficients are analyzed based on the measurement from strain gauges, load cell and CCD camera. Experimental results indicate that broad-banded lock-in region is found for the cylinder with a small Strouhal number. The frequency switches in the present study indicates the change of the VIV phenomenon. The hydrodynamic force responses provide more understanding on the VIV of a low mass ratio cylinder.

A People Counting Technique for Video Surveillance and Monitoring(VSAM) Systems (비디오에 의한 감시 및 관측(VSAM) 시스템을 위한 사람의 계수기법)

  • Do, Yong-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.28-38
    • /
    • 2002
  • People are important targets for video surveillance and monitoring(VSAM) but difficult to be analyzed. In this paper, a technique to count people in image sequences is dealt as a prerequisite procedure for automatic tracking and behaviour analysis. A group of people is divided at local minima of the line connecting the highest pixels on the binary image of the people extracted from the image taken by a stationary video camera. As the properties of the divided regions vary according to the relative positions of the people in a group, different states are assigned for the completely occluded, partially occluded, completed separated individual, and wrongly divided regions. By analyzing the transition of the states of divided regions, the number of people on the site monitored is estimated. The technique is checked in real experimental situations.

The measurement and evaluation of local scour at a bridge pier using the profiling scour monitoring system (프로파일링 세굴 모니터링 시스템을 이용한 교각 국부세굴 계측 및 평가)

  • Shin, Jong-Hyun;Park, Hyun-Il;Shin, Seung-Hyun;Park, Kyung-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.38-47
    • /
    • 2009
  • Scour means the erosion of bed material by flow change when a bridge is constructed in a stream. Scour is one of the critical factors of a bridge failure. There are several methods for the monitoring of scour near bridge foundations; Sounding rods, Magnetic sliding collar System, Sonar system, underwater camera system and so on. In general, Sonar system is preferred due to its convenience and good accuracy. In this study, the new scour monitoring system was developed using profiling sonar sensor. The new system can measure a line profile of a seabed and has small size due to the effectively designed data logger. The performance of the new scour monitoring system was evaluated at a bridge pier in tidal environment. The measured local scour depths were discussed with the result of the empirical formulas; CSU, Froehlich, Laursen and Neill.

  • PDF

A Study of Ubiquitous Hair Changing (Ubiquitous Hair Changing에 관한 연구)

  • Park Dae Woo;Kang Nan Soon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.1 s.33
    • /
    • pp.157-166
    • /
    • 2005
  • The Hair part of Cosmetology is development with Ubiquitous age. In this paper, 1 would design and implement for Ubiquitous Hair Changing on Ubiquitous network. Hair artist have customer's features in use digital camera for operating hair beauty. They are agree with hair design and style in monitor on internet at customer's choose in digital contents of cut, permanent, up-style, dye, long hair from web server. After operation on customer's hair from image of mobile terminal, hair artists take a photograph of customer's face and update it on internet. Customer's features was saved in her's mobile terminal. I would contribute to development of Beauty Information Society that the design of Ubiquitous Hair Changing System and the implement of digital hair contents that on-line internet system Sl mobile terminal were applied by Ubiquitous Network.

  • PDF

Effect of Process Parameters on Condenser Discharge Weldability of Thin Gauge Steel (박판 강재의 컨덴서 용접성에 미치는 용접변수의 영향)

  • 김기철;이목영;임태진
    • Journal of Welding and Joining
    • /
    • v.15 no.6
    • /
    • pp.49-56
    • /
    • 1997
  • Effect of process parameters on the quality of condenser discharge weld for coated sheet steels was discussed. The welding specimens were coated with pure Zn of 20/20 g/m2 in the production line. Direct measurements of welding parameters such as the discharge current, the pressures and the voltage drop across the electrodes were carried out with welding process monitoring system. High speed camera was also utilized to analyze the weld formation process. Test results indicated that the relation between weld strength and applied energy was stabilized at the acceptable welding heat input range. It was thought that the acceptable welding heat input should be redefined based on the monitored data because the calculated value of the welding heat input could hardly be utilized if the discharge condition was changed. Mechanical test results and high speed photographs showed that expulsion deteriorated the weld quality and the strength at the same time especially when the size of the spatter was large enough to carry the molten metal, which should form the nugget, out of the welding spot. Results also demonstrated that the discharge current should be applied at the appropriate time during the process because sufficient nugget was not produced if the time was deviated from the optimum range.

  • PDF

Speckle Reduction in Near-field Image of Multimode Fiber with a Piezoelectric Transducer

  • Ha, Woo-Sung;Lee, Se-Jin;Oh, Kyung-Hwan;Jung, Yong-Min;Kim, Jun-Ki
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.126-130
    • /
    • 2008
  • We propose and experimentally demonstrate an effective method to reduce near-field speckle noise at the output of a 50 ${\mu}m$ graded index multimode fiber using a short cylindrical piezoelectric transducer(PZT) vibrating in the radial direction. The fiber was coiled as tightly as possible around the mandrel of the PZT and a periodic stretching effect was caused by the radial oscillations of the actuator. The output of the optical fiber using the He-Ne laser source was intensively observed by a CCD camera. By counting all the pixels corresponding to relative intensity graded into 256 levels in the selected area and by calculating standard deviation and mean value of the intensity, we could measure the speckle contrast and vibration effect quantitatively with reduction ratio of pixels and line profile of the illuminated region. It was clearly observed that the characteristics of the speckle pattern in the vibration-on state were significantly improved over that of the vibration-off state due to time-averaged smoothing.

FPGA based System for Pinhole Detection in Cold Rolled Steel (FPGA 기반의 냉연강판 핀홀 검출 시스템)

  • Ha, Sung-Kil;Lee, Jung Eun;Moon, Woo Sung;Baek, Kwang Ryul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.8
    • /
    • pp.742-747
    • /
    • 2015
  • The quality of steel plate products is determined by the number of defects and the process problems are estimated by shapes of defects. Therefore pinholes defects of cold rolled steel have to be controlled. In order to improve productivity and quality of products, within each production process, the product is inspected by an adequate inspection system individually in the lines of steelworks. Among a number of inspection systems, we focus on the pinholes detection system. In this paper, we propose an embedded system using FPGA which can detect pinholes defects. The proposed system is smaller and more flexible than a traditional system based on expensive frame grabbers and PC. In order to detect consecutive defects, FPGAs acquire two dimensional image and process the image in real time by using correlation of lines. The proposed pinholes detection algorithm decreases arithmetic operations of image processing and also we designed the hardware to shorten the data path between logics due to decreasing propagation delay. The experimental results show that the proposed embedded system detects the reliable number of pinholes in real time.

Ortho-to-Para Ratio Studies of Shocked $H_2$ Gas Observed from Two Supernova Remnants IC 443 and HB 21

  • Shinn, Jong-Ho;Lee, Ho-Gyu;Moon, Dae-Sik
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.48.2-48.2
    • /
    • 2013
  • We present the near-infrared spectra (2.5-5.0 um) of shocked $H_2$ gas, observed with the Infrared Camera onboard the satellite AKARI. Two supernova remnants, IC 443 and HB 21, were observed. IC 443 shows a hint of non-equilibrium ortho-to-para ratio (OPR): 2.4 (-0.2, +0.3). HB 21 also shows an indication of a potential non-equilibrium OPR: 1.8-2.0. These non-equilibrium OPRs are first reported for shocked $H_2$ gas at E(v,J) > 7000 K, as far as we are aware. We concluded that the non-equilibrium OPR probably originates from dissociative J-shocks, considering several factors such as the shock combination requirement, the line ratios, and the possibility that $H_2$ gas can form on grains with a non-equilibrium OPR. The difference in the collision energy of H atoms on grain surfaces would give rise to the observed difference between the OPRs of IC 443 and HB 21, if dissociative J-shocks are responsible for the $H_2$ emission. Our study suggests that shocked-then-cooled $H_2$ gas may play as a heat reservoir with the non-equilibrium OPR.

  • PDF

Development of Underwater Motion Measurement System for Model Test of Ocean System (해양시스템 모형실험을 위한 수중운동계측시스템 개발 연구)

  • CHOI JONG-SU;HONG SUP
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.166-172
    • /
    • 2004
  • An underwater motion measurement system was constructed for applications to the model basin. A commercial motion capture system, FALCON of Motion Analysis Corp., which corrects automatically the distortion caused by refraction of the light passing through water and air, was adopted for underwater motion measurement. The modifications of FALCON system were performed: waterproofing camera housings, markers, connectors, and a new blue ring lighter. the accuracy of the motion measurement was obtained within the calibration error of 0.87mm in average and 0.89mm in standard deviation for the distance of 500mm between two markers on the calibration device. the volume of $2100mm(length)\times2100mm(breadth)\times2300mm(Height)$ was covered with 4 cameras of the underwater motion measurement system. For the performance verification, motion measurement test of a vertical mooring chain model excited at the top end was carried out. The 3D motions of mooring model were measured with variable amplitude and period of the forced excitation. Higher order motions of the mooring model were observed as the excitation period decreases. the performance of the system was verified by successfully measuring 3D motion of mooring model.

  • PDF