• 제목/요약/키워드: linac accelerator

검색결과 137건 처리시간 0.028초

상용 의학용 X-ray 필름의 특성곡선 (The Characteristic Curves of Commercial Medical X-ray Films)

  • 허훈;정연태;이재성
    • 한국인쇄학회지
    • /
    • 제19권2호
    • /
    • pp.12-21
    • /
    • 2001
  • For the purpose of determining characteristics of widely used commercial medical x-ray films, which are used for obtaining the Linac-grams for radiational treatment of cancers, we placed several commercial x-ray films at a fixed distance form the linear accelerator. After varying the exposed amount of radiation step by step, we could obtain a continually increasing density image for each film whose densities were determined by microdensitometer readings. The characteristic curves of the films were obtained by plotting the densities vs. the exposed radiation amounts, and their ${\gamma}$ values were determined. These values can be used to suggest a minimum necessary amount of exposed radiation to get a useful Linac-gram. The measured ${\gamma}$ values of the characteristic curves of the Kodak-DVP/RA-1 film were 1.73 when used 6MV x-ray, 1.70 when used 15MV of intensity. For the Konica-AX film, ${\gamma}$ values were 1.29 and 1.18 respectively. The result suggests that the effective conditions for high resolution of a L-gram be 6 MV of x-ray intensity and about 3 rad of exposed dose on a Kodak-DVP/RA-1 film.

  • PDF

Improvement of Beam-Quality Evaluation Method for Medical Linear Accelerator Using Magnetic Field

  • Kim, Jeongho;Han, Manseok;Yoo, Sejong;Kim, Kijin;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제20권2호
    • /
    • pp.120-128
    • /
    • 2015
  • Beam-quality of medical linac evaluations vary by diverse factors. Because conventional beam-quality evaluation methods yield fragmentary results, a new beam-evaluation method is suggested, and its feasibility is evaluated. The PDDs (percentage depth doses) of 6 MV (Mega-voltage) and 10 MV photon, R (Range) of a 6 MeV (Mega Electron-voltage) and 9 MeV electron were measured and compared with the conventional evaluation methods, and the improved methods $PDD^{10}{_5}$, $PDD^{20}{_{10}}$, $PDD^{30}{_{20}}$, $PDD^{20}{_5}$, $PDD^{30}{_{10}}$, and $R^{70}{_{50}}$, $R^{50}{_{30}}$, $R^{70}{_{30}}$ as the magnetic field of the bending magnet was changed to +2% to -2%, and the results were compared. The comparison showed that the improved methods exhibit a higher discrimination than the conventional methods in each energy regime. $PDD^{10}{_5}$, $PDD^{30}{_{20}}$, $PDD^{30}{_{10}}$ and $R^{70}{_{50}}$, $R^{50}{_{30}}$ should be applied. These methods exhibit a higher discrimination in each energy regime than conventional beam-quality evaluation methods; therefore, they should be used for beam-quality evaluation according to the magnetic field variation.

High Power RF Commissioning for S-band Electron LINAC

  • Park, Hyung Dal;Lee, Byeong-No;Song, Ki Baek;Cha, Sung Su;Kim, Yujong;Lee, Byung Cheol
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.111.2-111.2
    • /
    • 2013
  • 고주파 전자가속기는 고출력 RF 시스템으로 구동된다. 이러한 고주파 전자가속기에서 고출력 RF 시스템은 종종 고출력 방전으로 인해 가속관에 손상을 입힐 수 있기 때문에 조심스럽게 RF conditioning을 진행 하여야 한다. 일반적으로 RF conditioning은 아주 긴 시간을 필요로 하고, RF 출력을 서서히 높여가며 진행할 필요성이 있다. 한국원자력연구원에서는 9 MeV와 6 MeV 에너지를 출력하기 위해서는 가속관으로 RF 입력을 약 5.5 MW까지 RF conditioning을 진행하여야 한다. 따라서, 본 연구에서는 Klystron 최대 출력이 약 5.5 MW로 한국원자력연구원에서 개발된 S-band (2,856 MHz) RF 전자가속관에 RF conditioning을 진행 하였다. 가속관의 진공을 약 1.0e-7을 유지하면서 반복률을 10 Hz부터 180 Hz로 증가시켰고, RF 입력 파워는 약 6 MW까지 RF conditioning을 진행 하였다. 그 결과 짧은 시간에 RF commissioning을 진행할 수 있었다.

  • PDF

-중성자 TOF법에 의한 $^{99}Tc$의 에너지의존 중성자 포획단면적측정- (Measurement of the Energy-Dependent Neutron Capture Cross Section of $^{99}Tc$ by Using the Neutron TOF Method)

  • 윤정란;이상복;이준행;이삼열
    • 한국콘텐츠학회논문지
    • /
    • 제5권5호
    • /
    • pp.133-139
    • /
    • 2005
  • 교토대학 원자로실험소의 46-MeV 전자선형가속구를 이용하여 $^{99}Tc$의 중성자포획단면적을 중성자에너지 0.007 eV에서 47 keV에 걸쳐 중성자 비행시간법을 이용하여 측정을 하였다. 이 중성자포획 결과는 $^{10}B(n,\gamma)$반응의 중성자 반응 단면적에 상대적으로 얻어졌다. 얻어진 결과를 확인하기 위해서 교토대학 원자로실험소의 납감속장치를 이용한 결과를 확인하였다. TOF방법으로 얻어진 결과는 0.0253 eV에서의 결과(20.01 b)에 규격화되었다. 기존의 실험결과들과 평가결과들인 ENDF/B-VI, JENDL-3.2, and JEF-2.2은 본 연구에서 TOF와 납감속장치로 얻어진 결과들과 비교 및 검토하였다.

  • PDF

선형가속기를 이용한 방사선조사에서 생쥐조직의 생화학적 변화 (Biochemical Changes in the Tissue of Mice Irradiated with LINAC)

  • 최성관
    • 한국콘텐츠학회논문지
    • /
    • 제16권3호
    • /
    • pp.661-666
    • /
    • 2016
  • 본 연구에서는 선형가속기(LINAC)로 3 Gy의 방사선이 1회 전신조사된 마우스의 소장과 간 조직을 통해서 방사선피폭 후 세포를 보호하기 위해 생성되는 caspase (caspase 3 & caspase 9)와 NO (nitric oxide) 그리고 사이토카인(cytokine) 중 IL-6과 TNF-${\alpha}$ 등에 대해 알아보았고, 그 결과는 다음과 같다. 첫째, caspase 3 & caspase 9는 소장과 간 조직 모두 정상대조군보다 방사선조사군에서 두드러진 증가를 보였다(P<0.001). 둘째, NO (nitric oxide)는 소장과 간 조직 모두 정상대조군보다 방사선조사군에서 두드러진 증가를 보였다(P<0.001). 셋째, Cytokine 중 하나인 IL-6과 TNF-${\alpha}$는 소장과 간 조직 모두 정상대조군보다 방사선조사군에서 두드러진 증가를 보였다(P<0.001).

Mid-Term Performance of Clinical LINAC in Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • 제44권1호
    • /
    • pp.43-52
    • /
    • 2019
  • Background: The mid-term performance of clinical linear accelerator (LINAC) during volumetric modulated arc therapy (VMAT) treatment period is not performed in clinical practice and usually replaced with one-time plan quality assurance (QA). In this research we aim to monitor daily reproducibility of VMAT delivery from tracking individual leaf movement error and dosimetric error to evaluate the mid-term quality of the machine used. Materials and Methods: First, multileaf collimator (MLC) information was imported into MATLAB program to determine which of the MLC leaves in the leaf bank had the maximum RMS position error (maxRMS). We estimated where the maximum positional errors (maxPE) of the chosen leaf occur along its path length and tracked its daily variations over the entire treatment period. Secondly, picture information of dosimetric error from portal dosimetry was imported into MATLAB where representative high gamma index region (HGR) was determined as HGR with length of > 1 cm and their centers were daily tracked. Results and Discussion: The maxPEs in the brain and tongue cases were distributed broader than in other cases, but all data were found located within ${\pm}0.5mm$. From first day to last day all of five cases show the similar visual pattern of HGRs and Centers of the longest HGRs remained within ${\pm}1mm$ of that in first day. These findings prove excellent mid-term performance of the LINAC used in VMAT treatments over a full course of treatment. Conclusion: Tracking the daily location changes of leaf movement and dosimetric error can be a good indicator of predicting the daily quality like stability and reproducibility of beam delivering in VMAT treatment.

산업용 선형가속기 시스템 적용을 위한 30-MW 클라이스트론용 고 평균전력 펄스 트랜스포머의 설계 (Design of High Average Power Pulse Transformer for 30-MW Klystron of L-Band Linac Application)

  • 장성덕;손윤규;권세진;오종석;;;문성익;김상호;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1550-1551
    • /
    • 2006
  • An L-band linear accelerator system for e-beam sterilization is under design for bio-technology application. The klystron-modulator system as RF microwave source has an important role as major components to offer the system reliability for long time steady state operation. A PFN line type pulse generator with a peak power of 71.5-MW, $7{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present a system overview and initial design results of the high power pulse transformer.

  • PDF

토모테라피를 이용한 폐종양 방사선수술 계획 시 선량 분석 (Analysis on the Calculated Dose in the Lung Radiation Surgery Planning Using TomoTherpay)

  • 송주영;정재욱;윤미선;안성자;정웅기;나병식;남택근
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.178-183
    • /
    • 2011
  • 본 연구에서는 토모테라피를 이용한 폐종양의 방사선수술 치료계획을 수립한 후 기존의 선형가속기를 사용하였을 경우와 비교, 분석하여 선량분포 측면에서 유효성 및 타당성을 살펴보았다. 종양의 움직임이 5 mm 이하인 10명의 환자 CT 영상을 대상으로 기존의 선형가속기를 이용한 세기조절방사선수술에서와 동일한 처방선량과 동일한 조건의 중요장기 선량제한치로 토모테라피 치료계획을 수립한 후 선량분포를 비교하였다. 토모테라피를 이용한 결과에서도 기존의 선형가속기를 이용한 세기조절방사선수술과 동일하게 중요장기의 선량제한치를 충족시키면서 GTV에 처방선량을 부여할 수있음을 확인하였다. 방사선조사로 인한 폐의 정상조직합병증확률과 종양 반대편 폐의 등가균일선량 측면에서는 토모테라피가 기존 선형가속기보다 상대적으로 더 우수한 결과를 보였으나, 종양 내 치료선량 분포의 균일도에서는 기존 선형 가속기가 더 양호한 결과를 보였다. 치료 빔 전달 시간측면에서는 토모테라피가 기존 선형가속기 경우보다 2배 이상의 시간이 소요되었다. 이와 같은 본 연구의 결과 분석을 통해 폐종양 부위의 움직임이 적은 경우, 환자의 상태와 선량분포의 적합성 등을 고려한 최적의 치료계획을 세운다면 토모테라피를 사용하는 방사선 수술이 유효성 및 타당성이 있음을 확인할 수 있었다.

선형가속기 6 MV X선에 조사된 흰쥐의 간에서 아로니아의 방사선 방호효과 (The Radioprotection Effect of Aronia on Livers of Laboratory Rats Radiated to 6 MV X-ray of Linear Accelerator)

  • 이준행
    • 한국방사선학회논문지
    • /
    • 제14권2호
    • /
    • pp.97-104
    • /
    • 2020
  • 방사선이 조사된 흰쥐의 간에서 아로니아의 방사선 방호효과가 나타나는가를 혈청검사를 통하여 알아보고자 하였다. 실험동물은 (체중 200~250g) 수컷 흰쥐 5마리씩, 1군으로 정상군, 5 Gy 방사선대조군은 2군, 5 Gy 방사선조사 아로니아 실험군은 3군으로 설정하였다. 정상군 1군(A)은 일반식을 투여하고 방사선 조사를 실시하지 않고, 대조군 2군(B)은 일반식을 투여하여 방사선 조사를 하였고, 실험군 3군(C)는 방사선조사 전 14일 동안 아로니아, 경구투여량(100 mg/kg/day)로 1일 2회씩 50 mg/kg/day로 증류수에 희석하여 각각 흰쥐에 14일 동안 쥐용 존데를 이용하여 경구투여 후 방사선조사를 실시하였다, 이 연구를 위해서 Linac (선형가속기) 6 MV X선 치료장치를 사용하여 5 Gy 방사선이 1회 전신조사 된 흰쥐의 혈액을 채취하여 간에 관련된 5가지 혈청검사를 실시하였으며, 통계분석은 분산분석(ANOVA test)를 실시하였다. 결론적으로 실험분석을 확인한 결과는 아로니아의 간에 대한 방사선방호 효과가 없는 것으로 나타났다. 그러나 통계적으로 ALB (P > 0.05)는 유의성이 없고, TP (P < 0.05)는 유의한 차이가 있다고 확인되었다. 향후에는 다양한 검사가 이루어져야 할 것으로 사료된다.

MCNPX를 이용한 선형가속기의 6 MeV 전자선에 대한 에너지분포 계산 (Calculation of Energy Spectra for 6 MeV Electron Beam of LINAC Using MCNPX)

  • 이정옥;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.224-231
    • /
    • 2006
  • 본 연구에서는 MCNPX 코드를 사용하여 6 MeV 전자선의 에너지분포를 계산하였다. 이를 위하여 선형가속기(ML6M; Mitsubishi, Japan)의 헤드를 모델화하였다. 전자선의 초기에너지 분포는 가우시안으로 가정하였으며, 이 때 평균에너지는 측정과 계산으로 구한 $R_{50}$과 공기중 선량프로 파일을 평가하여 결정하였다. 결정된 빔 변수를 적용하여 선형가속기 헤드속 주요 위치에서의 전자선 에너지분포를 계산하였다. 어플리케이터 출구에서의 광자에 대한 에너지분포를 이용하여 깊이선량률에서 오염광자의 영향을 분석하였다.