For the purpose of determining characteristics of widely used commercial medical x-ray films, which are used for obtaining the Linac-grams for radiational treatment of cancers, we placed several commercial x-ray films at a fixed distance form the linear accelerator. After varying the exposed amount of radiation step by step, we could obtain a continually increasing density image for each film whose densities were determined by microdensitometer readings. The characteristic curves of the films were obtained by plotting the densities vs. the exposed radiation amounts, and their ${\gamma}$ values were determined. These values can be used to suggest a minimum necessary amount of exposed radiation to get a useful Linac-gram. The measured ${\gamma}$ values of the characteristic curves of the Kodak-DVP/RA-1 film were 1.73 when used 6MV x-ray, 1.70 when used 15MV of intensity. For the Konica-AX film, ${\gamma}$ values were 1.29 and 1.18 respectively. The result suggests that the effective conditions for high resolution of a L-gram be 6 MV of x-ray intensity and about 3 rad of exposed dose on a Kodak-DVP/RA-1 film.
Kim, Jeongho;Han, Manseok;Yoo, Sejong;Kim, Kijin;Cho, Jae-Hwan
Journal of Magnetics
/
제20권2호
/
pp.120-128
/
2015
Beam-quality of medical linac evaluations vary by diverse factors. Because conventional beam-quality evaluation methods yield fragmentary results, a new beam-evaluation method is suggested, and its feasibility is evaluated. The PDDs (percentage depth doses) of 6 MV (Mega-voltage) and 10 MV photon, R (Range) of a 6 MeV (Mega Electron-voltage) and 9 MeV electron were measured and compared with the conventional evaluation methods, and the improved methods $PDD^{10}{_5}$, $PDD^{20}{_{10}}$, $PDD^{30}{_{20}}$, $PDD^{20}{_5}$, $PDD^{30}{_{10}}$, and $R^{70}{_{50}}$, $R^{50}{_{30}}$, $R^{70}{_{30}}$ as the magnetic field of the bending magnet was changed to +2% to -2%, and the results were compared. The comparison showed that the improved methods exhibit a higher discrimination than the conventional methods in each energy regime. $PDD^{10}{_5}$, $PDD^{30}{_{20}}$, $PDD^{30}{_{10}}$ and $R^{70}{_{50}}$, $R^{50}{_{30}}$ should be applied. These methods exhibit a higher discrimination in each energy regime than conventional beam-quality evaluation methods; therefore, they should be used for beam-quality evaluation according to the magnetic field variation.
Park, Hyung Dal;Lee, Byeong-No;Song, Ki Baek;Cha, Sung Su;Kim, Yujong;Lee, Byung Cheol
한국진공학회:학술대회논문집
/
한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
/
pp.111.2-111.2
/
2013
고주파 전자가속기는 고출력 RF 시스템으로 구동된다. 이러한 고주파 전자가속기에서 고출력 RF 시스템은 종종 고출력 방전으로 인해 가속관에 손상을 입힐 수 있기 때문에 조심스럽게 RF conditioning을 진행 하여야 한다. 일반적으로 RF conditioning은 아주 긴 시간을 필요로 하고, RF 출력을 서서히 높여가며 진행할 필요성이 있다. 한국원자력연구원에서는 9 MeV와 6 MeV 에너지를 출력하기 위해서는 가속관으로 RF 입력을 약 5.5 MW까지 RF conditioning을 진행하여야 한다. 따라서, 본 연구에서는 Klystron 최대 출력이 약 5.5 MW로 한국원자력연구원에서 개발된 S-band (2,856 MHz) RF 전자가속관에 RF conditioning을 진행 하였다. 가속관의 진공을 약 1.0e-7을 유지하면서 반복률을 10 Hz부터 180 Hz로 증가시켰고, RF 입력 파워는 약 6 MW까지 RF conditioning을 진행 하였다. 그 결과 짧은 시간에 RF commissioning을 진행할 수 있었다.
교토대학 원자로실험소의 46-MeV 전자선형가속구를 이용하여 $^{99}Tc$의 중성자포획단면적을 중성자에너지 0.007 eV에서 47 keV에 걸쳐 중성자 비행시간법을 이용하여 측정을 하였다. 이 중성자포획 결과는 $^{10}B(n,\gamma)$반응의 중성자 반응 단면적에 상대적으로 얻어졌다. 얻어진 결과를 확인하기 위해서 교토대학 원자로실험소의 납감속장치를 이용한 결과를 확인하였다. TOF방법으로 얻어진 결과는 0.0253 eV에서의 결과(20.01 b)에 규격화되었다. 기존의 실험결과들과 평가결과들인 ENDF/B-VI, JENDL-3.2, and JEF-2.2은 본 연구에서 TOF와 납감속장치로 얻어진 결과들과 비교 및 검토하였다.
본 연구에서는 선형가속기(LINAC)로 3 Gy의 방사선이 1회 전신조사된 마우스의 소장과 간 조직을 통해서 방사선피폭 후 세포를 보호하기 위해 생성되는 caspase (caspase 3 & caspase 9)와 NO (nitric oxide) 그리고 사이토카인(cytokine) 중 IL-6과 TNF-${\alpha}$ 등에 대해 알아보았고, 그 결과는 다음과 같다. 첫째, caspase 3 & caspase 9는 소장과 간 조직 모두 정상대조군보다 방사선조사군에서 두드러진 증가를 보였다(P<0.001). 둘째, NO (nitric oxide)는 소장과 간 조직 모두 정상대조군보다 방사선조사군에서 두드러진 증가를 보였다(P<0.001). 셋째, Cytokine 중 하나인 IL-6과 TNF-${\alpha}$는 소장과 간 조직 모두 정상대조군보다 방사선조사군에서 두드러진 증가를 보였다(P<0.001).
Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
Journal of Radiation Protection and Research
/
제44권1호
/
pp.43-52
/
2019
Background: The mid-term performance of clinical linear accelerator (LINAC) during volumetric modulated arc therapy (VMAT) treatment period is not performed in clinical practice and usually replaced with one-time plan quality assurance (QA). In this research we aim to monitor daily reproducibility of VMAT delivery from tracking individual leaf movement error and dosimetric error to evaluate the mid-term quality of the machine used. Materials and Methods: First, multileaf collimator (MLC) information was imported into MATLAB program to determine which of the MLC leaves in the leaf bank had the maximum RMS position error (maxRMS). We estimated where the maximum positional errors (maxPE) of the chosen leaf occur along its path length and tracked its daily variations over the entire treatment period. Secondly, picture information of dosimetric error from portal dosimetry was imported into MATLAB where representative high gamma index region (HGR) was determined as HGR with length of > 1 cm and their centers were daily tracked. Results and Discussion: The maxPEs in the brain and tongue cases were distributed broader than in other cases, but all data were found located within ${\pm}0.5mm$. From first day to last day all of five cases show the similar visual pattern of HGRs and Centers of the longest HGRs remained within ${\pm}1mm$ of that in first day. These findings prove excellent mid-term performance of the LINAC used in VMAT treatments over a full course of treatment. Conclusion: Tracking the daily location changes of leaf movement and dosimetric error can be a good indicator of predicting the daily quality like stability and reproducibility of beam delivering in VMAT treatment.
An L-band linear accelerator system for e-beam sterilization is under design for bio-technology application. The klystron-modulator system as RF microwave source has an important role as major components to offer the system reliability for long time steady state operation. A PFN line type pulse generator with a peak power of 71.5-MW, $7{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present a system overview and initial design results of the high power pulse transformer.
본 연구에서는 토모테라피를 이용한 폐종양의 방사선수술 치료계획을 수립한 후 기존의 선형가속기를 사용하였을 경우와 비교, 분석하여 선량분포 측면에서 유효성 및 타당성을 살펴보았다. 종양의 움직임이 5 mm 이하인 10명의 환자 CT 영상을 대상으로 기존의 선형가속기를 이용한 세기조절방사선수술에서와 동일한 처방선량과 동일한 조건의 중요장기 선량제한치로 토모테라피 치료계획을 수립한 후 선량분포를 비교하였다. 토모테라피를 이용한 결과에서도 기존의 선형가속기를 이용한 세기조절방사선수술과 동일하게 중요장기의 선량제한치를 충족시키면서 GTV에 처방선량을 부여할 수있음을 확인하였다. 방사선조사로 인한 폐의 정상조직합병증확률과 종양 반대편 폐의 등가균일선량 측면에서는 토모테라피가 기존 선형가속기보다 상대적으로 더 우수한 결과를 보였으나, 종양 내 치료선량 분포의 균일도에서는 기존 선형 가속기가 더 양호한 결과를 보였다. 치료 빔 전달 시간측면에서는 토모테라피가 기존 선형가속기 경우보다 2배 이상의 시간이 소요되었다. 이와 같은 본 연구의 결과 분석을 통해 폐종양 부위의 움직임이 적은 경우, 환자의 상태와 선량분포의 적합성 등을 고려한 최적의 치료계획을 세운다면 토모테라피를 사용하는 방사선 수술이 유효성 및 타당성이 있음을 확인할 수 있었다.
방사선이 조사된 흰쥐의 간에서 아로니아의 방사선 방호효과가 나타나는가를 혈청검사를 통하여 알아보고자 하였다. 실험동물은 (체중 200~250g) 수컷 흰쥐 5마리씩, 1군으로 정상군, 5 Gy 방사선대조군은 2군, 5 Gy 방사선조사 아로니아 실험군은 3군으로 설정하였다. 정상군 1군(A)은 일반식을 투여하고 방사선 조사를 실시하지 않고, 대조군 2군(B)은 일반식을 투여하여 방사선 조사를 하였고, 실험군 3군(C)는 방사선조사 전 14일 동안 아로니아, 경구투여량(100 mg/kg/day)로 1일 2회씩 50 mg/kg/day로 증류수에 희석하여 각각 흰쥐에 14일 동안 쥐용 존데를 이용하여 경구투여 후 방사선조사를 실시하였다, 이 연구를 위해서 Linac (선형가속기) 6 MV X선 치료장치를 사용하여 5 Gy 방사선이 1회 전신조사 된 흰쥐의 혈액을 채취하여 간에 관련된 5가지 혈청검사를 실시하였으며, 통계분석은 분산분석(ANOVA test)를 실시하였다. 결론적으로 실험분석을 확인한 결과는 아로니아의 간에 대한 방사선방호 효과가 없는 것으로 나타났다. 그러나 통계적으로 ALB (P > 0.05)는 유의성이 없고, TP (P < 0.05)는 유의한 차이가 있다고 확인되었다. 향후에는 다양한 검사가 이루어져야 할 것으로 사료된다.
본 연구에서는 MCNPX 코드를 사용하여 6 MeV 전자선의 에너지분포를 계산하였다. 이를 위하여 선형가속기(ML6M; Mitsubishi, Japan)의 헤드를 모델화하였다. 전자선의 초기에너지 분포는 가우시안으로 가정하였으며, 이 때 평균에너지는 측정과 계산으로 구한 $R_{50}$과 공기중 선량프로 파일을 평가하여 결정하였다. 결정된 빔 변수를 적용하여 선형가속기 헤드속 주요 위치에서의 전자선 에너지분포를 계산하였다. 어플리케이터 출구에서의 광자에 대한 에너지분포를 이용하여 깊이선량률에서 오염광자의 영향을 분석하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.