References
- Han C, Liu A, Schultheiss, et al: Dosimetric comparison of helical tomotherapy treatment plans and step-and-shoot intensity- modulated radiosurgery treatment plans in intracranial stereotactic radiosurgery. Int J Radiat Oncol Biol Phys 65:608- 616 (2006) https://doi.org/10.1016/j.ijrobp.2006.01.045
- Sheehan JP, Shaffrey CI, Schlesinger D, et al: Radiosurgery in the treatment of spinal metastases: tumor control, survival, and quality of life after helical tomotherapy. Neurosurgery 65:1052-1061 (2009) https://doi.org/10.1227/01.NEU.0000359315.20268.73
- Vanderspek L, Bauman G, Wang JZ, et al: Dosimetric comparison of intensity-modulated radiosurgery and helical tomotherapy for the treatment of multiple intracranial metastases. Technol Cancer Res Treat 8:361-367 (2009) https://doi.org/10.1177/153303460900800506
- Lee TF, Chao PJ, Wang CY, et al: Dosimetric comparison of helical tomotherapy and dynamic conformal arc therapy in stereotactic radiosurgery for vestibular schwannomas. Med Dosim 36:62-70 (2011) https://doi.org/10.1016/j.meddos.2009.11.005
- Soisson ET, Hoban PW, Kammeyer T, et al: A technique for stereotactic radiosurgery treatment planning with helical tomotherapy. Med Dosim 36:46-56 (2011) https://doi.org/10.1016/j.meddos.2009.11.003
- Soisson ET, Tome WA, Richards GM, et al: Comparison of linac based fractionated stereotactic radiotherapy and tomotherapy treatment plans for skull-base tumors. Radiother Oncol 78: 313-321 (2006) https://doi.org/10.1016/j.radonc.2006.01.005
- Soisson ET, Mehta MP, Tome WA: A comparison of helical tomotherapy to circular collimator-based linear-accelerator radiosurgery for the treatment of brain metastasis. Am J Clin Oncol 34:388-394 (2011) https://doi.org/10.1097/COC.0b013e3181e9c0ee
- Kumar T, Rakowski J, Zhao B, et al: Helical TomoTherapy versus stereotactic Gamma Knife radiosurgery in the treatment of single and multiple brain tumors: a dosimetric comparison. J Appl Clin Med Phys 11:3245 (2010)
- Marks LB, Hanken RK, Martel MK: Quantitative analyses of normal tissue effects in the clinic. Int J Radiat Oncol Biol Phys 76:S20-S107 (2010) https://doi.org/10.1016/j.ijrobp.2009.02.091
- 김진성, 윤명근, 박성용 등: 방사선치료 관련 연구를 위한 선량 체적 히스토그램 분석 프로그램 개발. 대한방사선종양학회지 27:240-248 (2009)
- Jones LC, Hoban PW: Treatment plan comparison using equivalent uniform biologically effective dose (EUBED). Phys Med Biol 45:159-170 (2000) https://doi.org/10.1088/0031-9155/45/1/311
- Niemierko A: Reporting and analyzing dose distributions; a concept of equivalent uniform dose. Med Phys 24:103-110 (1997) https://doi.org/10.1118/1.598063
- Luxton G, Keall PJ, King CR: A new formula for normal tissue complication probability (NTCP) as a function of equivalent uniform dose (EUD). Phys Med Biol 53:23-36 (2008) https://doi.org/10.1088/0031-9155/53/1/002
- Kutcher GJ, Burman C, Brewster L, et al: Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations. Int J Radiat Oncol Biol Phys 21:137-146 (1991)
- Lyman JT: Normal tissue complication probabilities: variable dose per fraction. Int J Radiat Oncol Biol Phys 22:247-250 (1992) https://doi.org/10.1016/0360-3016(92)90040-O
- Semeneko VA, Li XA: Lyman-kutcher-Buman NTCP model parameters for radiation pneumonitis and xerostomia based on combined analysis of published clinical data. Phys Med Biol 53:737-755 (2008) https://doi.org/10.1088/0031-9155/53/3/014
- Wu Q, Mohan R, Morris M, et al: Simultaneous integrated boost intensity modulated radiotherapy for locally advanced head-and neck squamous cell carcinomas. I: dosimetric results. Int J Radiat Oncol Biol Phys 56:573-585 (2003) https://doi.org/10.1016/S0360-3016(02)04617-5
- Zhang T, Lu W, Olivera GH, et al: Breathing-synchronized delivery: a potential four-dimensional tomotherapy treatment technique. Int J Radiat Oncol Biol Phys 68:1572-1578 (2007) https://doi.org/10.1016/j.ijrobp.2007.02.054
- Lu W: Real-time motion-adaptive-delivery (MAD) using binary MLC: II. Rotational beam (tomotherapy) delivery. Phys Med Biol 53:6513-6531 (2008) https://doi.org/10.1088/0031-9155/53/22/015
- Lu W, Chen M, Ruchala KJ, et al: Real-time motionadaptive- optimization (MAO) in TomoTherapy. Phys Med Biol 54:4374-4398 (2009)